Inspection Report: IR No.: QETO/IR/SUD/114

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 2

INSPECTION REPORT IR No.

: QETO/IR/SUD/114 Page 01 of 02
VENDOR Associate Manufacturing Industries Corporation DATE 08.07.2020
P.O. NO. 4531038450 Dated 09.11.2019 JOB NO.
Hook (capacity 10t), PO Item no.10: 4nos. DRG NO. 11002.50.32.302
ITEMS
Nut, PO item no 30: 4nos. 11001.ST.NUT.005
QAP NO. Hook_CP3_190058_001 DATASHEET NO.
CLIENT JINDAL STEEL & POWER LIMITED, RAIPUR CLIENT PO NO.
A. INSPECTION ACTIVITIES: INPROCESS / STAGE INSPECTION FINAL INSPECTION
1. Welder Qualification (WPS/PQR/WPQ)- Witness 10. Fit-up / Alignment Check 19. Performance Test 28. Painting Check (DFT)
2. Welder Qualification (WPS/PQR/WPQ)- Review 11. Dimensional Check 20. Noise Level 29. Packing
3. Raw Material Identification 12. Trial Assembly Check 21. Vibration Level 30. Loading / Dispatch
4. Lab Witness of Samples 13. Trial Run Test / Functional Check 22. Strip Test Other Activities (If Any):
5. Non Destructive Test- (NDT)- UT 14. Load Test 23. Visual / Appearance Check 31.
6. Non Destructive Test- (NDT)- RT Review 15. Hardness Test (Other than Lab Witness) 24. Surface Finish Check (Ra) 32.
7. Non Destructive Test- (NDT)- LPT 16. Temperature Rise 25. PMI Test 33.
8. Non Destructive Test- (NDT)- MPT 17. Speed of Rotation 26. Pressure Test (Hydrotest / Pneumatic) 34.
9. Weld Edge Preparation/Bevelling 18. Shaft Run Out / Deflection. 27. Surface Preparation / Blasting 35.
ACTIVITIES PERFORMED (Write down the respective activity numbers from above listed “Inspection Activities”:

B: OBSERVATIONS & DETAILS OF INSPECTION ACTIVITIES CARRIED (Including REMARKS if any):

1. Load testing witnessed for above mentioned set of hook with nut with 20t load. No permanent deformation observed.
2. All the items found acceptable visually after the load testing. Fitting of nut with the hook found smooth after load testing.
3. Test report (Field report) is attached herewith.

4. Identification mark stamped on each item as


5. Dimension checking and NDT after load testing are pending as the facilities were not available at the site.

Name & Sign: Name & Sign: Name & Sign:


For QETO- QUALITY SERVICES For CLIENT / CUSTOMER For VENDOR / SUPPLIER
M/s QETO Quality Services, IR Format No.: DOC-IR-01, R.01
INSPECTION REPORT Page 02 of 02

Continuation Sheet for IR No.: QETO/IR/SUD/114 IR Date: 08.07.2020


B: PHOTOGRAPHS:

C: CONCLUSION:
Result of load testing is acceptable for all above mentioned items.

Name & Sign: Name & Sign: Name & Sign:


For QETO- QUALITY SERVICES For CLIENT / CUSTOMER For VENDOR / SUPPLIER

M/s QETO Quality Services, IR Format No.: DOC-IR-01, R.01