Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Flat Bar Capacity Check

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Flat Bar Checking

Section type 50mm x 6mm thk.


Steel grade ; S275
Nominal thickness ;tnom 6 mm
Nominal width ; 50 mm
2
Nominal yield strength ;fy 275.00 N/mm
2
Nominal ultimate tensile strength ; fu 410.00 N/mm
2
Modulus Elasticity ;E 210.00 kN/mm
Unit weight ;M 2.36 kg/m
2
Section Area ;A 300 mm
3 4
Section Modulus = bd /12 ;Iy 62500 mm
2 3
= bd /6 ;Zy 2500 mm

From Sframe Analysis


Design bending moment My,Ed ; 0.25 kNm
Design shear force Vy,Ed ; 1.00 kN

Design Shear Resistance


2
Shear Area = 0.9A ; Av 270 mm
Vc,Rd = Vpl,Rd Plastic shear resistance = 0.6Av  fy ; Vc,y,Rd 44.55 kN
= Vy,Ed / Vc,y,Rd ; 0.02 < 1.0
Pass - Design shear resistance exceeds design shear force

= 0.6V c,Rd ; 26.73 kN


Shear is minimum

Design Moment Capacity = Zy  fy ; 0.69 kNm


Pass - Design bending resistance exceeds design bending moment