Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Design of Combined Footing (Cf1)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

DESIGN OF COMBINED FOOTING (CF1)

Design Of Combined Footing Node


1 LENGTH AND WIDTH OF THE FOOTING
BEARING CAPACITY OF THE SOIL (qu) = 150 KN/m^2
CG OF LOADS FROM PROPERTY LINE (X) = 1.584 m
LENGTH OF THE FOOTING = 2.667 m
ASSUMING WEIGHT OF FOOTING AND EARTH ABOVE IT AS 5% OF TOTAL WEIGHT,
TOTAL LOAD ON EARTH = 367.9601 KN
HENCE WIDTH OF FOOTING = 0.92 m

ADOPT THE WIDTH OF THE FOOTING = 2.03 m

2 LONGITUDINAL BENDING MOMENT AND SHEAR


FACTORED LOAD ON COLUMN A = 392.15 KN
FACTORED LOAD ON COLUMN B = 159.79 KN
NET UPWARD SOIL PRESSURE = 68.06 KN/m^2
NET UPWARD SOIL PRESSURE PER UNIT LENGTH = 137.97 KN/m
MAX SHEAR FORCE AT CENTER LINE OF COLUMN A (V1)= -157.70 KN
MAX SHEAR FORCE AT CENTER LINE OF COLUMN A (V2)= 234.45 KN
MAX SHEAR FORCE AT CENTER LINE OF COLUMN B (V1)= 0.00 KN
MAX SHEAR FORCE AT CENTER LINE OF COLUMN B (V2)= -159.79 KN
POINT OF ZERO SHEAR FORCE FROM CENTER OF COLUMN A (x)= 0.91 m
MAXIMUM BENDING MOMENT FROM LEFT SIDE = -65.69364917 KN-m
MAXIMUM BENDING MOMENT FROM RIGHT SIDE = -72.38476736 KN-m
HENCE MAXIMUM BENDING MOMENT = 72.38476736 KN-m
DEPTH OF THE FOOTING REQUIRED (d) = 113.7419715 mm

ADOPT THE OVERALL DEPTH OF THE FOOTING = 400 mm


EFFECTIVE DEPTH OF THE FOOTING = 350 mm

3 MAIN NEGATIVE LONGITUDINAL REINFORCEMENT @ TOP


AREA OF STEEL REQUIRED (Ast) = 483.9227238 mm^2
ADOPT THE REBAR SIZE 12 mm
ADOPT THE SPACING OF REBARS = 150 mm
NO. OF REBARS REQUIRED = 14 NOS
AREA OF STEEL PROVIDED (Ast) = 1583.362697 mm^2
CHECK FOR PROVIDED STEEL OK
DEVELOPMENT LENGTH FOR THE ADOPTED BARS = 672 mm

4 MAIN POSITIVE LONGITUDINAL REINFORCEMENT @ BOTTOM


BENDING MOMENT AT FACE OF COLUMN A = 68.02150143 KN-m
BENDING MOMENT AT FACE OF COLUMN B = 1.552137655 KN-m
MAXIMUM BENDING MOMENT = 68.02150143 KN-m
AREA OF STEEL REQUIRED (Ast) = 454.2695809 mm^2
ADOPT THE REBAR SIZE 12 mm
ADOPT THE SPACING OF REBARS = 150 mm
NO. OF REBARS REQUIRED = 14 NOS
AREA OF STEEL PROVIDED (Ast) = 1583.362697 mm^2
MINIMUM AREA OF STEEL REQUIRED (Ast min) = 973.056 mm^2
CHECK FOR PROVIDED STEEL OK
DEVELOPMENT LENGTH FOR THE ADOPTED BARS = 672 mm

5 ONE WAY SHEAR CHECK


PERCENTAGE OF TENSILE STEEL PROVIDED (p)= 0.22 %
FOR COLUMN A
SHEAR FORCE (Vu) = 165.46 KN
NOMINAL SHEAR STRESS (τv) = 0.233 N/mm^2
SHEAR STRENGTH OF CONCRETE (τc) = 0.34 N/mm^2
CHECK FOR ONE WAY SHEAR SAFE
FOR COLUMN B
SHEAR FORCE (Vu) = 90.81 KN
NOMINAL SHEAR STRESS (τv) = 0.128 N/mm^2
SHEAR STRENGTH OF CONCRETE (τc) = 0.34 N/mm^2
CHECK FOR ONE WAY SHEAR SAFE

6 TWO WAY SHEAR CHECK


FOR COLUMN A
SHORT SIDE / LONG SIDE (βc) = 1
ks = 1
τc = 1.12 N/mm^2
τc' = 1.12 N/mm^2
SHEAR FORCE (Vu) = 363.39 KN
NOMINAL SHEAR STRESS (τv) = 0.399 N/mm^2
CHECK FOR TWO WAY SHEAR SAFE
FOR COLUMN B
SHORT SIDE / LONG SIDE (βc) = 1
ks = 1
τc = 1.12 N/mm^2
τc' = 1.12 N/mm^2
SHEAR FORCE (Vu) = 131.04 KN
NOMINAL SHEAR STRESS (τv) = 0.144 N/mm^2
CHECK FOR TWO WAY SHEAR SAFE
7 TRANSVERSE REINFORCEMENT
Effective Depth,d= 338 mm
Factored Upwared Pressure under column A = 193 kN/m
BM at the face of column A= 72.13496982 kNm
Width of strip from Left face Under Column A= 1631 mm
Area of tension steel, At 502.3011501 mm^2
ADOPT THE REBAR SIZE 12 mm
ADOPT THE SPACING OF REBARS = 150 mm
NO. OF REBARS REQUIRED = 11 NOS
AREA OF STEEL PROVIDED (Ast) = 1244.070691 mm^2

Factored Upwared Pressure under column A = 79 kN/m


BM at the face of column A= 29.39415939 kNm
Width of strip from Left face Under Column A= 976 mm
Area of tension steel, At 203.1469032 mm^2
ADOPT THE REBAR SIZE 12 mm
ADOPT THE SPACING OF REBARS = 150 mm
NO. OF REBARS REQUIRED = 7 NOS
AREA OF STEEL PROVIDED (Ast) = 791.6813487 mm^2

8 TEMPERATURE REINFORCEMENT PROVISION


MINIMUM AREA OF STEEL REQUIRED (Ast min) = 973.056 mm^2
ADOPT THE REBAR SIZE 12 mm
ADOPT THE SPACING OF REBARS = 150 mm
NO. OF REBARS REQUIRED = 14 NOS
CHECK FOR PROVIDED STEEL 1583.362697 mm^2
CHECK FOR PROVIDED STEEL OK