STRAP BEAM CALCULATION OF Bimala Regmi
STRAP BEAM CALCULATION OF Bimala Regmi
STRAP BEAM CALCULATION OF Bimala Regmi
porject….
Data: Status of designe:
Exterior column load [KN].unfactored = 193 0
Interior column load [KN].unfactored = 282 CHECK SHEAR EXT. FOOTING
Load factor = 1.5
Distance between column center lines[m] = 3.70
Depth of foundation Df [m] = 1.82927
Allowable bearing capacity of soil [KN/sq.m] = 150
Width of ext. col. In strap beam direction [m] = 0.3
Width of ext. col. In direct perpendicular strap beam [m] = 0.3
Width of int. col. In strap beam direction [m] = 0.3
Width of int. col. In direct perpendicular strap beam [m] = 0.3
Breadth of strap beam [m] = 0.3
Eccentricity of exterior load from footing [m] = 0.9
R.C designation : Fcu [N/sq.mm] = 20
reinf. Strength : Fy [N/sq.mm] = 415
density of soil [KN/cu.m] 20
Calculation:
reaction of ext.footing R1 254.60 [KN]
geo. reaction of ext.footing R1T 336.72 [KN]
Req. ext. footing 2.24 [sq.m] Dim. sq 1.49827
Use dimensions for ext.footing L= 1.4 [m] Area prov.d 2.94 131%
B= 2.1 [m] in strap direction
Use dimensions for int.footing L= 1.9 [m] Area prov.d 3.42 176%
B= 1.8 [m] in strap direction
check dim 1
Page 1 of 13
Designe of strap beam:
Breadth of strap beam [m] 0.3
depth of strap beam from shear d 436.86 [mm]
Use depth d 500 [mm] 1
total depth H 550 [mm]
fcu = 20 N/smm fy = 415 N/smm
Ult. column load 381.89 [KN] Safe bearing capacity 150 [KN/sq.m]
Self weight 51.45 [KN] Overburden height 1.33 m A prvd.
Overburden 136.78 [KN] Area of footing reqd. 2.62 m2 1
Total load 570.12 [KN] Area of footing provided 2.94 m2 L reqd.
Net upward pressure ult. 193.92 [KN/sq.m] Footing thickness 500 [mm] 1.25
Short span Long span B/W
Width B= 2.10 m Length L= 1.40 m 0.67
Column width 300.00 mm Column breadth 300 mm
Max. cantilever proj. 1.80 m Max. cantilever proj. 0.55 m As min
Max. B.M. /m width 314.15 kNm Max. B.M. /m width 29 kNm 577
Page 2 of 13
Designe of interior footing:
Net presure under int. footing 107.03 [KN/sq.m] 1
Ult. column load 330.107143 [KN] Safe bearing capacity 150 [KN/sq.m]
Self weight 60 [KN] Overburden height 1.33 m A prvd.
Overburden 159 [KN] Area of footing reqd. 2.52 m2 1
Total load 549 [KN] Area of footing provided 3.42 m2 L reqd.
Net upward pressure ult. 161 [KN/sq.m] Footing thickness 500 [mm] 1.40
Short span Long span B/W
Width B= 1.80 m Length L= 1.90 m 1.06
Column width 300 mm Column breadth 300 mm
Max. cantilever proj. 0.75 m Max. cantilever proj. 0.80 m As min
Max. B.M. /m width 45 kNm Max. B.M. /m width 51 kNm 577
Page 3 of 13
FOR FOOTING : STRAP FOOTING CONNECTION EF1 and F1 Status of designe:
Exterior column load [KN].unfactored = 193 1
Interior column load [KN].unfactored = 282 .
Load factor = 1.5
Distance between column center lines[m] = 3.70
Depth of foundation Df [m] = 1.83
Allowable bearing capacity of soil [KN/sq.m] = 150
Width of ext. col. In strap beam direction [m] = 0.3
Width of ext. col. In direct perpendicular strap beam [m] = 0.3
Width of int. col. In strap beam direction [m] = 0.3
Width of int. col. In direct perpendicular strap beam [m] = 0.3
Breadth of strap beam [m] = 0.3
R.C designation : Fcu [N/sq.mm] = 20
reinf. Strength : Fy [N/sq.mm] = 415
density of soil [KN/cu.m] 20
Calculation:
reaction of ext.footing R1 254.60 [KN]
geo. reaction of ext.footing R1T 336.72 [KN]
Req. ext. footing 2.24 [sq.m] Dim. sq 1.498272
Use dimensions for ext.footing L= 1.83 [m] Area prov.d 2.94 131%
B= 1.7 [m] in strap direction
Use dimensions for int.footing L= 1.9 [m] Area prov.d 3.42 176%
B= 1.8 [m] in strap direction
check dim 1
Ult. column load 381.89 [KN] Safe bearing capacity 150 [KN/sq.m]
Self weight 97.76 [KN] Overburden height 0.88 m A prvd.
Overburden 90.48 [KN] Area of footing reqd. 2.62 m2 1
Total load 570.12 [KN] Area of footing provid 2.94 m2 L reqd.
Net upward pressure ul 193.92 [KN/sq.m] Footing thickness 950 [mm] 1.25
Short span Long span B/W
Width B= 2.10 m Length L= 1.40 m 0.67
Column width 300.00 mm Column breadth 300 mm
Max. cantilever proj. 1.80 m Max. cantilever proj. 0.55 m As min
Max. B.M. /m width 314.15 kNm Max. B.M. /m width 29 kNm 1162
K = M/bd2fcu 0.020 N/mm2 K = M/bd2fcu 0.002 N/mm2 No. of bars
Z 837.90 mm Z 849 mm 12
As required /m width 1038.43 [mm] As required /m width 96 [sq.mm] 13
Diameter of bars 12 [mm] Diameter of bars 12 [mm]
Spacing of bars 125 [mm] Number of bars/side 160 [mm] As prvd. 1
As provided/m width 1077 [sq.mm] As provided/m width 754 [sq.mm] 104%
788%
Punch shear 0.00 [KN] Dist. to critical section 900 [mm]
Punch shear stress 0.00 [N/sq.mm] Shear force 175 [KN]
Allow.shear stress 0.28 [N/sq.mm] Shear stress 0.20 [N/sq.mm] 1
Ult. column load 330.1071 [KN] Safe bearing capacity 150 [KN/sq.m]
Self weight 114 [KN] Overburden height 0.88 m A prvd.
Overburden 105 [KN] Area of footing reqd. 2.52 m2 1
Total load 549 [KN] Area of footing provid 3.42 m2 L reqd.
Net upward pressure ul 161 [KN/sq.m] Footing thickness 950 [mm] 1.40
Short span Long span B/W
Width B= 1.80 m Length L= 1.90 m 1.06
Column width 300 mm Column breadth 300 mm
Max. cantilever proj. 0.75 m Max. cantilever proj. 0.80 m As min
Max. B.M. /m width 45 kNm Max. B.M. /m width 51 kNm 1162
3 5
2 S.F.D
X
Column type with 1.5 without 1.50 C/C DIST 15.6456 4.77
Exterior 615 410
interior 817.5 545
Use dimensions for ext.footing
L 1.4 4.59
B 2.1 6.89
Use dimensions for int.footing 0.55
L 1.9 6.23
B 1.8 5.91
STRAP BEAM
B 0.3 0.3 0.98424 11.81
D 550 0.55 1.80444 21.65
Use dimensions for ext.footing L= 2.1 [m] Area prov.d 2.42 127%
B= 1.15 [m] in strap direction
Page 10 of 13
Designe of strap beam:
Breadth of strap beam [m] 0.3
depth of strap beam from shear d 418.00 [mm]
Use depth d 450 [mm] 1
total depth H 500 [mm]
fcu = 20 N/smm fy = 500 N/smm
Ult. column load 342.61 [KN] Safe bearing capacity 150 [KN/sq.m]
Self weight 38.04 [KN] Overburden height 1.05 m A prvd.
Overburden 88.75 [KN] Area of footing reqd. 2.16 m2 1
Total load 469.39 [KN] Area of footing provided 2.42 m2 L reqd.
Net upward pressure ult. 194.37 [KN/sq.m] Footing thickness 450 [mm] 1.88
Short span Long span B/W
Width B= 1.15 m Length L= 2.10 m 1.83
Column width 350.00 mm Column breadth 300 mm
Max. cantilever proj. 0.80 m Max. cantilever proj. 0.90 m As min
Max. B.M. /m width 62.20 kNm Max. B.M. /m width 79 kNm 512
Page 11 of 13
Designe of interior footing:
Net presure under int. footing 109.40 [KN/sq.m] 1
Ult. column load 446.393258 [KN] Safe bearing capacity 150 [KN/sq.m]
Self weight 63 [KN] Overburden height 1.05 m A prvd.
Overburden 147 [KN] Area of footing reqd. 3.02 m2 1
Total load 656 [KN] Area of footing provided 4.00 m2 L reqd.
Net upward pressure ult. 164 [KN/sq.m] Footing thickness 450 [mm] 1.51
Short span Long span B/W
Width B= 2.00 m Length L= 2.00 m 1.00
Column width 300 mm Column breadth 300 mm
Max. cantilever proj. 0.85 m Max. cantilever proj. 0.85 m As min
Max. B.M. /m width 59 kNm Max. B.M. /m width 59 kNm 512
Page 12 of 13
Column type with 1.5 without 1.50
Exterior 308 205.3333
interior 481 320.6667