04 Samss 003
04 Samss 003
04 Samss 003
1 Scope........................................................... 2
2 Conflicts and Deviations............................... 2
3 References................................................... 2
4 Design.......................................................... 3
5 Materials....................................................... 3
6 Marking......................................................... 4
1 Scope
This specification, along with the purchase order, defines the minimum additional
requirements for steel valves in services with minimum design temperatures in the
range of -18ºC to -45ºC. All requirements as stated in the specifications attached to the
purchase order remain fully applicable except as modified herein.
2.1 Any conflicts between this specification and other applicable Saudi Aramco
Materials System Specifications (SAMSSs), Engineering Standards (SAESs),
Standard Drawings (SASDs), or industry standards, codes, and forms shall be
resolved in writing by the Company or Buyer Representative through the
Manager, Consulting Services Department of Saudi Aramco, Dhahran.
2.2 Direct all requests to deviate from this specification in writing to the Company or
Buyer Representative, who shall follow internal company procedure SAEP-302
and forward such requests to the Manager, Consulting Services Department of
Saudi Aramco, Dhahran.
3 References
The selection of material and equipment, and the design, construction, maintenance, and
repair of equipment and facilities covered by this specification shall comply with the
latest edition of the references listed below, unless otherwise noted.
Page 2 of 4
Document Responsibility: Valves 04-SAMSS-003
Issue Date: 31 May 2005 Additional Requirements
Next Planned Update: 1 June 2010 for Low Temperature Valves
In case of conflict between this specification and the referenced documents, this
specification shall take precedence.
4 Design
4.1 The vendor shall ensure that all valves that permit pressure to be trapped in the
body cavity in any closure position are provided with means to prevent
excessive pressure build-up due to thermal expansion of liquids.
4.2 Valves that are classified as "Double Block & Bleed", shall either (a) be of a
self-relieving design, or (b) be provided with an external relief system that will
relieve pressure to the upstream or downstream side. Option (b) shall be
approved by the Chairman of the Valves Standards Committee.
4.3 Valves that are not classified as "Double Block & Bleed" e.g., flexible wedge,
double disc, soft-seated wedge and split wedge gate valves, floating seat ball
valves, and other similar valves, shall either (a) be of a self-relieving design, or
(b) have a 3–5 mm hole drilled in the upstream side of the closure element to
relieve cavity pressure; such valves shall have the flow direction clearly marked
on the body.
Page 3 of 4
Document Responsibility: Valves 04-SAMSS-003
Issue Date: 31 May 2005 Additional Requirements
Next Planned Update: 1 June 2010 for Low Temperature Valves
5 Materials
5.1 All nonmetallic seats, seals and packing shall be suitable for continuous
exposure to design service conditions. The selected materials shall retain
adequate resilience after prolonged and cyclic loading.
5.2 For valve designs with stuffing box, the stem packing shall be a combination
packing consisting of two (2) braided graphite filament 99% carbon end rings
(JC-1625G or equal) and graphite intermediate rings (JC-237 or equal).
5.3 All bolting shall be ASTM A320, Grade L7. The corresponding nuts shall be
ASTM A194, Grade 4.
5.5 All appurtenances such as plug, nipple , relief, drain, and vent valve shall be
AISI Type 316L stainless steel.
6 Marking
6.1 In addition to the normal marking requirements, the valves shall have a 25 mm
wide orange stripe on both sides, parallel with the longitudinal axis of the valve.
Flanged valves shall also have the flange rim painted orange.
6.3 In addition to other requirements in the purchase order, the valve shall be
permanently marked with the minimum design temperature.
Revision Summary
31 May 2005 Major revision.
Page 4 of 4