8. Super function. Compatible with FX3G/FX2U/FX3S series PLC, operation speed more fast. Max Current 500mA
2. I/O Points: 16 : 8DI/8DO 24: 12DI/12DO 32 : 16DI/16DO 34 : 18DI/16DO ON Respond Time High-speed output: 10μs, and others 0.5ms
48 : 24DI/24DO 64 : 32DI/32DO 68 : 32DI/36DO 80 : 40DI/40DO
3. Module: M: Main Module High-speed Output Frequency 8 channels: Y0-Y3 is 100KHz, Y4-Y is 10KHz.
4. DO type: R: relay T: transistor RT: relay and transistor mixed High-speed counting and pulse can't over 480KHz.
5. AI: 0~16 channles are optional COM connected with negative terminal NPN
Vol
6. AO: 0~8 channels are optional
7. AI type: EK Thermocouple(can be customized T, S, J type) Analog Input Index
PT: PT100 NTC:Thermal resistance (10K/50K/100K)
A0:0-20mA A4: 4-20mA V:0-10V V5:0-5V Input Signal PT100/PT1000/thermocouple/NTC/0-10V/0-5V/0-20mA/4-20mA/ customizations.
8. AO type: V:0-10V V5:0-5V A0:0-20mA
9. C1 stands for singe phase high-speed counting, C2 for AB phase counting, C3 for ABZ counting. Normally Respond Time One scanning cycle
single-phase 6 60KHz or AB (Z) phase 2 60KHz+ 1 10KHz.
10. P stands for high-speed pulse; normally 8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz.High-speed AI Quantity 0-16 channels
counting + high-speed pulse total output can not exceed 480KHz.
Accuracy 12bits
11. COM port: 2 RS485 port are default, 34M / 64M / 80M can be customized 1 485 port and 1 232 port, CAN
is optional; 16M / 24M / 32M / 48M can be customized as 1 485, 1 232 or 1 485, 1 CAN 1 232, 1 CAN.
Analog Output Index
Diagram 3 Hardware Interface Drawing
◆ Basic specification Diagram1: basic parameters Output Signal 0-5V/0-10V/0-20mA/4-20mA
Switching Analog High-speed High-speed TXD 485+ A
CX3G series Value Points COM Port Size AO Quantity 0-8 channels
counting pulse
standard RXD 485- B
PLC Max Max Single AB ABZ Dimension Cutout size Accurary 12bits 3G PLC PIN definition
DI DO AI AO 485/232/CAN phase phase phase Output (MM) (MM) ① ②
Pin NO . Signal Description GND
③ ④ ⑤
Normally 8 channels Y0-Y3 100KHz,
CX3G-16M 8 8 0 0 Interface
Normally single phase 6 60KHz or
1 485、1 232 COM port and 1 232 port, CAN is optional; 16M/24M/32M/48M can be customized PLC programming Diagram 5 com port optional
CX3G-30M 16 14 2 2
Or 1 485、1 CAN as 1 485, 1 232 or 1 485, 1 CAN or 1 232, 1 CAN.
CX3G-32M 16 16 2 0 Or 1 232、1 CAN Terminals wiring standard: 22-14AWG wire. This series terminals are all pluggable terminals.
Environment
CX3G-48M 24 24 8 4 COM port definition:
Y4-Y7 10KHz;
1K
104p ◆ 0~10V or 0~20mA(1~16 channels)AD0~AD15 address is R23620~R23635
X0 0V
AD15 + (Analog input 16) ※ The temperature type is one digit after the decimal point. That is register value is 182=actual value
3.9K 18.2 degrees.
GND - (0~20mA/0~10V Analog output common) ※ Analog input sampling
D8073 is the smoothing filter coefficient for all analog inputs. Setting range: 0~999
DA0 + (Analog output 1)
Number of filter cycles = (R23600~R23615)* The scan time of the PLC. The default value is 0. If R23600=1
1K
Analog input is AD0~AD15
+ one PLC scan cycle is sampled once and the value in the first analog input is changed once.,
3.9K
X1 AO DA1 (Analog output2) Analog output is DA0~DA7
The bigger the value of R23600~R23615 is set, the more stable the result is.
The negative terminals are respectively connected
to the GND of the analog input/output terminals. D8073 is the smoothing filter coefficient for all analog inputs. The setting range is 0~999
Diagram 6 Input wiring diagram
◆ Analog output register(DA means analog output, precision is 12 bit); supports TO instructions or
Figure 7 shows the equivalent circuit diagram of the relay output module. The output terminals are several DA7 + (Analog output8) register direct assignment operation
Adopts TO K0 K0 D500 K8 instructions, there are 8 channels of analog 0~10V or 0~20mA; register direct
groups. Each group is electrically isolated. Different groups of output contacts are connected to different power Diagram 11 PLC analog wiring
PLC analog wiring assignment operation D8050~D8057.
circuits.
Two-wire system: the positive pole of the power supply is connected to the positive pole of the Serial Number Register address Setting range Output type
transmitter; the negative pole of the transmitter is connected to the AD side;4-20MA/0-20MA transmitter
Sink output type wiring method; Three-wire system: the positive pole of the power supply is connected to the positive DA0 D8030 0-4000
Load
Y007 Load pole of the transmitter, the negative pole of the power supply and the negative pole of the signal output
Y007 DA1 D8031 0-4000
are the same terminal, and the transmitter signal output is connected to the AD terminal;
DA2 When D8058.0~D8058.7=0
Load Four-wire system: the positive and negative poles of the power supply are respectively connected to the D8032 0-4000
Load positive and negative poles of the power supply of the transmitter, and the positive and negative poles Type is 0~20mA;
Y004 Y004 DA3 D8033 0-4000
COM1 of the transmitter signal output are respectively connected to the AD and GND terminals;
COM1 DA4 D8034 0-4000
Fuse DC24V fuse The analog line of temperature is connected to the AD terminal and the GND terminal respectively. If it When D8058.0~D8058.7=1
DC24V
is a three-wire Pt100, it needs to be connected in two lines. The GND common terminal of the analog DA5 D8035 0-4000 Type is 4~20mA。
Load Load input and output can be shared.
Y003 DA6 D8036 0-4000
Y003 PLC anti-interference processing
1. Strong and weak currents should be separated and wired, and not common ground; DA7 D8037 0-4000
Load Load
Y000 Y000
when there is strong electric interference, magnetic rings should be added on the power supply side;
The CX3G PLC's device power-off maintenance is permanently maintained, that is, all the devices in the holding area are not lost
and properly and effectively grounded according to the type of the chassis. after the module is powered off.
COM0 COM0
~
fuse AC0~220V fuse
2. When the analog quantity is disturbed, 104 ceramic capacitors can be added for filtering, and a correct The real-time clock uses a rechargeable battery to ensure that the clock is the current time. All power-off hold functions must e
DC24V and effective grounding can be performed. nsure DC 24V.The voltage after the source is loaded is 23V or more, and the PLC power-on time is longer than 2 minutes,
otherwise the power-off function will be abnormal.
Diagram 7 Relay output equivalent circuit Diagram 8 Transistor output equivalent circuit Programming Reference
Programming software: compatible with Mitsubishi programming software GX8.86 and WORKS2
The equivalent circuit of the PLC output part of the transistor output type is shown in Figure 8. Also known
◆ Devices Distribution and Statement of Power-down Save Detailed materials please refer to <Coolmay PLC programming user manual >
CX3G-16M CX3G-80M
<CX3G PLC user manual> <FX3GX PLC user manual>
from the figure, the output terminals are several groups, each group is electrically isolated, and different
Digital input X00~X07 X00~X11 10 point X00~X13 X0~X17 X00~X17 X00~X21 X00~X27 X00~X37 X00~X47
groups of output contacts can be connected to different power circuits; the transistor output stage can X 8 point 16 point 24 point 32 point 40 point
X00~X13 12 point 12 point 16 point 18 point
only be used for DC 24V load circuits. Output wiring is NPN, COM common cathode. Digital output Y00~Y07 Y00~Y13 12 point Y00~Y13 Y0~Y15 Y00~Y17 Y00~Y17 Y00~Y27 Y00~Y37 Y00~Y47
For the inductive load connected to the AC circuit, the external circuit should consider the RC Y 8 point Y00~Y11 10 point 12 point 14 point 16 point 16 point 24 point 32 point 40 point
transient voltage absorption circuit; corresponding to theinductive load of the DC loop, consider TIPS
CX3G PLC User Manual
Auxiliary Relay M [M0~M383]384p oint [M1536-M7679]6144point general [M384~M1535] 1152point Holding [M8000~M8511] 512point Specially —— Before using this product, please read the relevant manual
adding a freewheeling diode, as shown in diagram 9. Carefully use the product under the environmental conditions
State S [S0-S9] 10point Initial state/ [S10~S999] 990point holding/ [S1000~S4095] 3096point general
Stepping or servo motor wiring as shown in Figure 10, 5V drive must be connected to a 2KΩ resistor specified in the manual.
Timer T [T0~T199] 200point 100ms general/ [ T200~T245] 46point 10ms general/ [T246~T249] 4point 1ms grand total keep state/ [T250~T255] 6point 100ms grand total keep state/ [T256~T319] 64point 1ms general
on DC24V 1.In canse of damaging the product, please confirm power supply range first (the regular power
16bit 32bit High-speed counting supply only limitied to 24V DC, we suggest you to use the power supply which output voltage
PLC relay output Counter C [C235~C245 single phase single counting ] [C246~C250 single phase dual counting] is 18W or higher than 18W), and wiring correctly, then electrify it.
[C0~C15] 16point General [C16~C199] 184point Holding [C200~C219] 20point General [C220~C234] 15point Holding [C251~C255 dual phase dual counting keep state]
Y1 COM0
2.Before installting the product, please tighten the screw and clamp guide to avoid falling.
Data Register D,V,Z [D0~D127] 128point general [D128~D7999] 7872point Holding [D8000~D8511] 512point special [R0-R23999] 24000point holding [V0~V7] [Z0~Z7] 16point Indexing 3. Please do not wiring or plug cable when the power is on, otherwise it may cause electric shock
Inductive load
Nested Pointer [N0~N7] 8point [P0~P127] 256point [P0~P1280] 1281point(26232and higher version) JUMP、CALL Branch or circuit damagement. Disconnect the power switch immediately when the product smells or
K 16bit -32,768~32,767 32bit -2,147,483,648~2,147,483,647
sounds abnormal. Do not drop metal shavings and wire tips into the control vent holes during
DC24Vtransistor
Constant screwing hole and wiring, which may cause product malfunctions and faults.
H 16 bits 0-FFFFH 32 bits 0-FFFFFFFFH 4. Please do not tie the power cord and communication cable together or let them too close, you
Freewheeling diode 1N404
should keep them for more than 10cm distance. The strong and weak electricity should be
PLC transistor output
-
◆ Analog intput register(AD means analog input, precision is 12 bit); supports FROM instructions or register
direct assignment operation
separated and properly grounded. If the interference is serious the communication and high
Direction(Dir)
frequency signal input and output cables should be the shielded cables to improve anti-jamming
Y10 COM2
Y7 + E.g:FROM K0 K0 D400 K16 reads 16 channel analog input 0-10V. Register directly according to the type of performance. The grounding terminal FG on this unit must be properly grounded, which can
- analog input, refer to the following address improve the anti-interference ability.
Inductive load Y6 The following address applies to software version 26210 5.The digital input is an externally powered DC24V leakage type (passive NPN) with the input
+ Pulse(Pul)
DC24V power supply Y5 ◆ address
K type thermocouple(1~4 channel)AD0~AD3 address is R23680~R23683, the 5th is ambient temperature,
is R23684, (6~16 channel)AD4~AD15 address is R23685~R23695.
signal isolated from the power supply. When using, connect S/S to 24V positive external power
supply.
-
6. The COM of the binary input / output (transistor) is common to the cathode.
Freewheeling diode 1N404 Y4
+
Direction(Dir) ◆ PT100(1~16 channel)AD0~AD15 address is R23640~R23655. 7.Do not disassemble the product or modify the wiring optionally . Otherwise it may cause fault,
PLC relay output
COM1
- ◆ NTC10K(1~16 channel)AD0~AD15 address is R23660~R23675. malfunction, loss, or fire.
Y4 COM1
+
Pulse(Pul) ◆ 0~10V/0-5V or 0~20mA(1~16 channel)AD0~AD15 address is D8030~D8045. 8.Please make sure to turn off the all power when you install or dismantle the product, otherwise
◆ 4~20mA(1~16 channel)AD0~AD15 address is R23620~R23635. it may cause malfuction or fault.
Inductive load The following address applies to software version 26220
-
C R
~
AC220V power supply
Y3 +
Direction(Dir) ◆ temperature,
K type thermocouples(1~4 channel)AD0~AD3 address is R23680~R23683,the 5th way is ambient
address is R23684, (6~16 channel)AD4~AD15 address is R23685~R23695.
R=200Ω C=0.22uF,250VAC
-
◆ channel
K type thermocouple negative temperature(1~4channel)AD0~AD3address is R23720~R23723, the 5th
Shenzhen Coolmay Technology Co., Ltd
Catalog
Y2
+
Pulse(Pul) is ambient temperature, address is R2372, (6~16 channel)AD4~AD15 address is R23725~R23735.
Warm Tips…...……………………………………………01
PLC relay output Y1 ◆ ambient
T type thermocouple(1~4 channel )AD0~AD3 address is R23700~R23703,the fifth channel is
temperature,address is R23704, (6~16 channel)AD4~AD15 address is R23705~R23715.
Tel.: 0755-86950416
Product Features …………………………...…………02
86960332
Product informati………………………...……………03
Y5 COM1 Y0
-
+
Direction(Dir) ◆ channel
T type thermocouple negative temperature(1~4 channel)AD0~AD3 address is R23740~R23743, the fifth
is Ambient temperature ,address is R23744, (6~16channel)AD4~AD15 address is R23745~R23755'
26051858 Electrical parameter… ………………....……………04
COM0
26400661 Mechanical design reference…..….…………….05
Inductive load -
Pulse(Pul)
◆ PT100(1~16 channel)AD0~AD15 address is R23640~R23655. Fax: 0755-26400661-808 Electrical Design Reference……………………….06
~
AC220V power supply
PLC Internal
equivalent circuit
R +
◆ NTC10K(1~16 channels)AD0~AD15 address is R23660~R23675. QQ: 800053919 Equivalent Circuit………………………………………07
Varistor 10D471k (undercurrent)
DC24V(5V drive requires 2kΩ resistor) ◆ 0~10V/0-5V or 0~20mA(1~16 channels)AD0~AD15 address is D8030~D8045. Email: 800053919@b.qq.com Analog wiring………………………….………………..08
Diagram 9 Inductive load absorption circuit schematic Diagram 10 Pulse output wiring diagram
◆ 4~20mA(1~16channels)AD0~AD15 address is R23620~R23635. Website: www.coolmay.net Anti-jamming treatmet……………………………..09
※ 0~10V/0-5V or 0~20mA in D8030~D8045, the analog register occupies D8039, so the constant scan time Programming Reference…………...………………10
function is not supported defaultly.
※ Note: All internal circuits in the illustrations are for reference only. Version: 2018/11 Information Reference………………………………11