Quadra Audio/video Entrance Panel Art. 4893M: Technical Manual
Quadra Audio/video Entrance Panel Art. 4893M: Technical Manual
Quadra Audio/video Entrance Panel Art. 4893M: Technical Manual
TECHNICAL
MANUAL
Table of contents
Warning............................................................................................. 2
Description........................................................................................ 3
Technical features............................................................................ 4
Installation......................................................................................... 5
Changing nameplates...............................................................................6
Settings............................................................................................. 7
Programming.................................................................................... 8
Call address programming for 2/4 users and additional external unit.8
Operation with additional external units.................................................9
Operation with switching device 1404 (default).....................................9
Operation with switching device 1405....................................................9
Programming a generic call address....................................................10
Disabling the COM-RTE contact...........................................................11
Connections.................................................................................... 12
Door open indication use variant..........................................................12
Variant for using a safety door lock and additional power supply.....12
Using the RC network for door lock filter on relay contacts..............12
2
Description
Wall-mounted external unit for Quadra series door entry monitor. Die-cast aluminium front panel, wide-angle colour video
camera and single LED for lighting at night. Mechanical buttons with the option of setting 1 to 4 call buttons via DIP-switch.
Indicator LED for call sent, lock-release activated, audio activated and system busy. Loudspeaker volume adjustment and
audio balancing. Bus line power supply.
1.
2.
3.
8.
4.
1 9.
10.
11.
12.
13.
14.
5. 1
15.
2
6.
1
2
3
4
7.
16.
3
Technical features
MAIN FEATURES
Type Monoblock entrance panel
Type of finish Die-cast aluminium
Audio/video system Yes
Wall-mounted Yes
Camera Colors
Lens size (mm) 2,1
Diagonal viewing angle (°) 100
Minimum colour illumination (lux) 1
Power supply Bus
Maximum current absorption (mA) 250
Clamps LL RTE COM DO SE- SE+C NC NO
Buttons to call Yes
Total buttons 4
Microphone volume control Yes
Loudspeaker volume control Yes
Operating temperature (°C) -25 ÷ +55
IP protection rating IP54
Vandal Resistant rating (IK code) IK08
HARDWARE SPECIFICATIONS
Visual signalling Yes
Acoustic signalling Yes
GENERAL DATA
Product height (mm) 195
Product width (mm) 95
Product depth (mm) 28
COMPATIBILITY
Kit audio/video system Yes
ELECTRICAL SPECIFICATIONS
Door release (dry contact bridge) Yes
4
Installation
The camera must not be installed in front of light sources, or in places where the filmed subject is against
the light. In dim environments, we recommend additional lighting is provided.
OPEN
1
1 2 3
M
TCEO
R
163 cm
130 cm
2 L
L
4
4 5
Loudspeaker 1
1 O
J
1 NH
D
2 EO 3
Microphone
1
2
3
4
Settings 6
You can download the free software (art. 1235A) to print the entrance panel name cards, using the adhesive
pre-cut sheets available in our catalogue (art. 1217A).
5
• Before securing the screw, make sure that you do not need to program the external unit and make sure
that the metal front panel does not rub against other metal parts, with consequent risk of damage to its
insulating coating.
• While the system is running, take care not to accidentally call users when replacing the nameplate labels.
3
1
CLACK!
1
OE
ND
JOH 1
CLACK!
seepage DO
E
risk! 3 JO
HN
2
OE
JOHN D
1 4
2 CLOSE
7 8
To ensure that the product remains water-tight, make sure that the fixing procedure is carried out correctly.
Changing nameplates
SS
PRE JOH
ND
OE
1 ITH
. SM
MR
1 OE
ND
JOH
ITH
. SM
MR
6
Settings
Set the DIP-switches of S1 corresponding to the function that you want to programme as shown in the table below.
DIP-SWITCH FUNCTION
The lock-release relay and the second relay are controlled by 2 separate buttons (e.g. lock-
release button and actuator button)
DIP 1
The lock-release relay and the second relay are controlled by a single button (e.g. lock-release
button)
*
DIP 2
DIP 3
DIP 4
DIP 5
DIP 6
DIP 7
DIP 8
* default
7
Programming
Call address programming for 2/4 users and additional external unit
On the DIP-switch, set the code corresponding to the function you want to program as shown in the table.
Single external unit Quadra, or additional external unit connected with digital
8 4
switching device art. 1404 (default condition)
3 4
Reset the configuration of the DIP-switches
8
Operation with additional external units
• External unit with switching device art. 1404: default programming to be used with single external unit or with multiple
external units connected with switching device art. 1404.
• Secondary external unit: function to be used in systems with switching device art. 1405 and 2 external units.
• Main external unit: function to be used in systems with switching device art. 1405 and 2 external units.
With the switching device 1404 it is possible to install 2 or more external unit.
In the configuration of art. 1404, the MIN and MAX DIP-switches define respectively the lowest and highest user codes which
can be connected to the riser. For information on setting the desired values, refer to the addressing table.
Separate switching devices for different risers must manage code ranges which are not overlapping.
The self-ignition command will activate the camera of the external unit. Further self-ignition commands will toggle between 2
(max) external units, activating them alternately.
For the diagrams, please refer to the Audio/Video kit system section in the system manual
With the switching device 1405 it is possible to install only 1 main external unit and 1 secondary external unit.
In “Main external unit” mode, lock-release (or actuator) commands are only executed if the external unit is in call or self-
ignition mode. The "door-open" function is always deactivated.
In “Secondary external unit” mode, lock release (or actuator) commands are executed if the system is in standby mode or if
the external unit is active.
If the system is in standby mode the first self-ignition command will activate the camera of the secondary external unit.
Further commands will toggle between 2 (max) external units, activating alternately the main external unit and the secondary
external unit.
For the diagrams, please refer to the Audio/Video kit system section in the system manual
9
Programming a generic call address
1
Set the user code using the DIP-switches in accordance with the addressing table
4
Reset the configuration of the DIP-switches.
10
Disabling the COM-RTE contact
1
Set the DIP-switches to position 206 (ON 2,3,4,7,8) in accordance with the addressing table
4
Reset the configuration of the DIP-switches.
11
Connections
1209
SE SE NC NO C R C D
L L
-+
T O
E M O
4893M
Variant for using a safety door lock and additional power supply
12/24V
AC/DC
SE SE NC NO C R C D
L L
-+
T O
Local door-opener button E M O
4893M
Using the RC network for door lock filter on relay contacts
w w w.comelitgroup.com
Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy