MIDAS/Civil: 1. Design Condition

This document summarizes the results of structural checks on a reinforced concrete column. It provides details on the design conditions, applied loads, axial and moment capacity checks, and an interaction diagram. The column passed the axial load ratio, moment ratio, and shear force capacity checks.

Uploaded by

topan full2
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
131 views

MIDAS/Civil: 1. Design Condition

This document summarizes the results of structural checks on a reinforced concrete column. It provides details on the design conditions, applied loads, axial and moment capacity checks, and an interaction diagram. The column passed the axial load ratio, moment ratio, and shear force capacity checks.

Uploaded by

topan full2
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MIDAS/Civil RC Column Checking Result

Company Project Title


Author ACER File Name D:\...\PILAR ALT2.mcb

1. Design Condition
Design Code ACI318-02
Unit System kN, m
Member Number 2602 (PM), 2712 (Shear)
Material Data fc' = 30000, fy = 400000, fys = 400000 KPa

1
Column Height 1m
Section Property BP D1m (2) (No : 11)
Rebar Pattern Pos 1 Pos 2 Pos 3
Layer 1 20-D25 -- --
Total Rebar Area Ast = 0.010134 m² (Rhost = 0.0129) 0.1005

2. Applied Loads
Load Combination 15 AT (I) Point
Pu = -1128.6 kN, Mcy = 131.914, Mcz = 31.0582, Mc = 135.521 kN-m

3. Axial Forces and Moments Capacity Check


Concentric Max. Axial Load phiPn-max = 12387.9 kN
Axial Load Ratio Pu/phiPn = -1128.6 / -2865.7 = 0.394 < 1.000 ....... O.K
Moment Ratio Mcy/phiMny = 131.914 / 333.763 = 0.395 < 1.000 ....... O.K
Mcz/phiMnz = 31.0582 / 77.9959 = 0.398 < 1.000 ....... O.K
Mc/phiMn = 135.521 / 342.755 = 0.395 < 1.000 ....... O.K

4. P-M Interaction Diagram


P(kN)
24465

Theta=13.15Deg. phiPn(kN) phiMn(kN-m)


21574
N.A=13.25Deg.
15484.84 0.00
18683
12211.49 1131.05
15791
10092.03 1561.76
12900
12388 8304.56 1778.61
10009 6873.09 1875.83

7117
5738.58 1916.37
5163.72 2010.58
4226
4611.12 2072.89
1334
0 3950.89 2120.46
-1557 M(kN-m) 3009.64 2143.46
(-1129,136)

(-2866,343)
-4448 1089.01 1689.83
1017

1356

1695

2034

2373

2712

3051

3390
339

678

0 -1450.03 885.77
-3648.24 0.00

5. Shear Force Capacity Check


Applied Shear Strength Vu = 23.2836 kN (Load Combination 15)
Shear Strength by Conc phiVc = 328.021 kN
Shear Strength by Rebar phiVs = 304.080 kN (2.0-D13 @200)
Shear Ratio Vu/phiVn = 23.2836 / 632.101 = 0.037 < 1.000 ....... O.K

Modeling, Integrated Design & Analysis Software Print Date/Time : 04/26/2021 16:20
http://www.MidasUser.com
MIDAS/Civil V 8.1.0