Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

MIDAS/Civil: 1. Design Condition

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

MIDAS/Civil RC Column Checking Result

Company Project Title


Author ACER File Name D:\...\PILAR ALT2.mcb

1. Design Condition
Design Code ACI318-02
Unit System kN, m
Member Number 2602 (PM), 2712 (Shear)
Material Data fc' = 30000, fy = 400000, fys = 400000 KPa

1
Column Height 1m
Section Property BP D1m (2) (No : 11)
Rebar Pattern Pos 1 Pos 2 Pos 3
Layer 1 20-D25 -- --
Total Rebar Area Ast = 0.010134 m² (Rhost = 0.0129) 0.1005

2. Applied Loads
Load Combination 15 AT (I) Point
Pu = -1128.6 kN, Mcy = 131.914, Mcz = 31.0582, Mc = 135.521 kN-m

3. Axial Forces and Moments Capacity Check


Concentric Max. Axial Load phiPn-max = 12387.9 kN
Axial Load Ratio Pu/phiPn = -1128.6 / -2865.7 = 0.394 < 1.000 ....... O.K
Moment Ratio Mcy/phiMny = 131.914 / 333.763 = 0.395 < 1.000 ....... O.K
Mcz/phiMnz = 31.0582 / 77.9959 = 0.398 < 1.000 ....... O.K
Mc/phiMn = 135.521 / 342.755 = 0.395 < 1.000 ....... O.K

4. P-M Interaction Diagram


P(kN)
24465

Theta=13.15Deg. phiPn(kN) phiMn(kN-m)


21574
N.A=13.25Deg.
15484.84 0.00
18683
12211.49 1131.05
15791
10092.03 1561.76
12900
12388 8304.56 1778.61
10009 6873.09 1875.83

7117
5738.58 1916.37
5163.72 2010.58
4226
4611.12 2072.89
1334
0 3950.89 2120.46
-1557 M(kN-m) 3009.64 2143.46
(-1129,136)

(-2866,343)
-4448 1089.01 1689.83
1017

1356

1695

2034

2373

2712

3051

3390
339

678

0 -1450.03 885.77
-3648.24 0.00

5. Shear Force Capacity Check


Applied Shear Strength Vu = 23.2836 kN (Load Combination 15)
Shear Strength by Conc phiVc = 328.021 kN
Shear Strength by Rebar phiVs = 304.080 kN (2.0-D13 @200)
Shear Ratio Vu/phiVn = 23.2836 / 632.101 = 0.037 < 1.000 ....... O.K

Modeling, Integrated Design & Analysis Software Print Date/Time : 04/26/2021 16:20
http://www.MidasUser.com
MIDAS/Civil V 8.1.0