Reference conditions
1. Power-related data
3. Consumption
6. Heat dissipation
53 Coolant temperature R 66 °C
(at engine outlet to cooling equipment)
8 Coolant temperature before intercooler A - °C
(with max. 40% antifreeze)
14 Coolant temperature before intercooler, limit 1 L 78 °C
15 Coolant temperature before intercooler, limit 2 L 80 °C
54 Coolant temperature differential after/before L 6 K
intercooler, min.
55 Coolant temperature differential after/before L 14 K
intercooler, max.
13 Coolant antifreeze content, max. L 50 %
76 Temperature differential between intake air and A 30 K
charge-air coolant before intercooler
75 Temperature differential between intake air and L 32 K
charge-air coolant before intercooler, max.
20 Cooling equipment: coolant flow rate A 39 m³/h
21 Intercooler: coolant flow rate R 39 m³/h
24 Coolant pump: inlet pressure, min. L 0.5 bar
25 Coolant pump: inlet pressure, max. L 2.5 bar
31 Pressure loss in off-engine cooling system, max. L 0.7 bar
without thermostat
43 Cooling equipment: height above engine, max. L 15 m
36 Breather valve (expansion tank) R 1.0 bar
opening pressure (excess pressure)
37 Breather valve (expansion tank) R -0.1 bar
opening pressure (depression)
38 Pressure in cooling system, max. L 5.0 bar
42 Cooling equipment: operating pressure A 2.5 bar
Edition 6/2/2021 Technical Sales Document
Page 12/27
- Product Data -
18. Capacities
22. Acoustics