tec 301 HCS (UAE) Formerly "Conrep.

301 HCS" TECHNICAL AND


REPAIR MORTARS

Non shrink very high strength grout

PRODUCT
tec 301 HCS is a blend of portland cement, special
admixtures and proprietary aggregates designed to provide
high flexural and compressive strength performance from
plastic to fluid consistencies. tec 301 HCS is non-metallic,
non-shrink, non-gas forming and contains no chlorides or
aluminum powders. It is specialy used when repair of high
strength concrete is required.

SCOPE OF USE
• Assembly of pre-cast parts made of reinforced or
pre-stressed concrete
• Bridge bearing applications
• Concrete jacketing for slabs, columns, beams and footings
• Reblocking / restumping / void filling applications
• Closing or filling around pipes in water tanks / swimming
pools PACKAGING
• Pumpablity properties Leb Syria Jordan UAE Qatar Kuwait KSA Oman
• Anchoring of steel bars - - - 25 kg - - - 25 kg
• Jointing - - - 50 kg - - - 50 kg
• Fixing industrial equipment and heavy machinery, mounting
plates
• Vertical shoring
• Void filling operations
• Excellent shock & vibration resistance CHARACTERISTICS
Appearance Grey powder
ADVANTAGES Grain size 0 to 3 mm
• Non-shrinking Free from chlorides and
• High strength metallic particles
• Easy to apply Fresh density 2340 kg/m³
• Resistant to sea water and sulfates (BS 1881:83)
• Liquid or plastic consistency Lengthchange 0.062 % @ 28 days
(ASTM C157-03)
Pull off stress > 1.5 N/mm² @ 28 days
(BS 1881 Part 207)

*COMPRESSIVE STRENGTH
AGE 1 day 7 days 28 days
COMPRESSIVE STRENGTH (N/mm²) 32 57 72
STANDARD BS-EN 196-1 BS-EN 196-1 BS EN 196-1

*FLEXURAL STRENGTH & TENSILE STRENGTH at 28 days


AGE 28 days
FLEXURAL STRENGTH (N/mm²) – BS EN 196 -1 7
TENSILE STRENGTH (N/mm²) – BS 6319:PART 7: 1985 3.8

*Results obtained at fluid consistency: 12% water or 6 lit. per 50 kg bag.


The mechanical carateristics will be higher if the tec 301 HCS is mixed at plastic consistency: 9.5% water or 4.75 lit. per 50 kg bag. In this case,
the compressive strength can exceed 80 MPa at 28 days.

1/2 Technical data sheet . Edition: 09.19-A www.middleeast.weber


tec 301 HCS (UAE) TECHNICAL AND
REPAIR MORTARS

APPLICABLE STANDARDS STORAGE


BS EN 196 Part 1 12 months after manufacturing date in original and non-open
BS 1881 Part 207 packaging , under cover, in dry condition, away from humidity,
ASTM C 157-03 protected from extreme temperatures and direct sunlight.
BS 6319 – Part 7- 1985
BS 1881: 83 PRECAUTIONS
ASTM C 1107 Substrate must be sound and resistant. It should be saturated
with water a few hours prior to installation. Remove all water
INSTRUCTIONS FOR USE used in wetting support prior to installation of tec 301
PRODUCT PREPARATION HCS.
Grout or mortar is obtained by mixing tec 301 HCS with Do not mix with other hydraulic binders.
clean water. The amount of water used depends on the
workability required. SAFETY PRECAUTIONS
Add the powder to the water and mix for 3 minutes. To The product contains cement powders which, when mixed
ensure a homogeneous and uniform mix, an electric mixer with water, release alkalis that could be harmful to the skin. It
must be used. is preferable that the application be done in a ventilated
area, and to wear protective gear for hands, eyes and
Mixing respiratory system and to avoid breathing of the dust.
tec WATER (1) VOLUME IN Splashes on the skin should be washed away by cleaning
301 HCS PLACE with soap and water. In case of contact with eyes, wash
MORTAR 50 Kg 4.5-5 lit. 26 lit thoroughly with clean water. If swallowed, do not induce
GROUT 50 Kg 5.5-6 lit. 28 lit. vomiting, in both cases seek medical attention. The product
(1): Half quantity of water is required for 25 Kg package is non-flammable.
PRODUCT APPLICATION
For grouting /jacketing/repair
DISCLAIMER
While the company guarantees its products against defective
tec 301 HCS can be used for thickness up to 10 cm.
materials, the use and application of these products are
Existent surface needs to be roughened and cleaned. Ensure
made without guarantee since the conditions of their application
damping the surface with water before the application.
are beyond its control. It is recommended to verify with the
Thickness above 10 cm can be practiced up to 30 cm in case
company that the product is suitable for the intended use,
of epoxy anchoring dowels (rebars) installation in the
and that this Data Sheet version is the latest one. The company
existent structure by (pouring) the Pure epoxy (anc 405
may modify it without prior notice. Technical characteristics
BFX) into drilled holes in the existent structure, then steel
are listed for guidance only. For more information, please
mesh to be connected to Dowels (rebars). Ideal Application
contact the company’s office in your location.
temperature is between +5 ºC and 35 ºC

For Shoring/Soil Nailing Applications NOTE


tec 301 HCS can be used for grouting the inclined holes The information included on this Technical Data Sheet is the
in shoring applications. Hole diameter must not exceed 20 sole property of SODAMCO Holding. The unauthorized disclosure,
cm, depth of hole will be determined by structure engineer. use, dissemination or copying (either whole or partial) of this
tec 301 HCS is high fluid and non-shrink properties data sheet or any information it contains, is prohibited and
ensure excellent anchoring/friction with soil/rocks. If the subject to legal pursuit.
application temperature is higher than 35 ºC, make sure to
PG:24
use cool water to keep the mixed grout temperature below
*Available only in UAE
30 ºC.

CURING
Protect the work against rapid drying from wind, sun and
excessive heat by using a curing compound like ad
cure WH or ad cure Y 40 or by covering with properly
secured plastic sheeting.

2/2 Technical data sheet . Edition: 09.19-A www.middleeast.weber