Aerodrome Beacon
Aerodrome Beacon
Aerodrome Beacon
BEACON 1
BEACON LIGHT
Operating and Maintenance Manual BEACON
Table of Contents
1. General
2. Technical Information
3. Function
5. Maintenance
6. Material List
7. Drawing
2
Operating and Maintenance Manual BEACON
Safety Instructions
Safety precautions:
Operating and maintenance personnel should refer to ICAO Airport Services Manual
Part 9, “Airport Maintenance Practices” and to FAA Advisory Circular AC 150/5340-26
“Maintenance of Airport Visual Aid Facilities” for instruction on safety precautions.
Airport personnel must always observe safety regulations. Our equipment has been
designed and manufactured to allow safe and secure operation, however, the following
rules must be strictly observed.
Resuscitation
Operating and maintenance personnel should get acquainted with the resuscitation
techniques described in the First Aid Instruction Manual issued by the Red Cross
Organization or similar.
3
Operating and Maintenance Manual BEACON
Warranty
YOUYANG Airport Lighting Equipment Inc warrants the products against any
defect in design, material or workmanship, for a period of 3 years from the date
of delivery to the original purchaser. Within the frame of this warranty
YOUYANG accept to replace the defective item free of charge, ex works.
Operational failure or breakage resulting from lamp burnt out, improper
maintenance or installation, damage due to runway maintenance equipment,
snow ploughs or aircraft arresting gear hooks are not considered as result of
proper use and is beyond the scope of the warranty. The warranty does not
cover glassware, prisms, lens, filters and lamps.
The above constitutes the limit of YOUYANG’s liabilities in connection with the
equipment covered by this manual.
4
Operating and Maintenance Manual BEACON
1. General
Beacon Light is designed primarily for day and night operation as identification and
location of civil airports, seaplane airports and heliports.
The color of light depends on the aviation regulation and the local condition as follows ;
- White / Green : BEACON 1
- White / Green/Yellow : BEACON 2
2. Technical information
YOUYANG Beacon is consist of the upper parts (rotation parts) with rotation axis, lamps,
reflector, color lens and the lower parts with motor, gear, slip ring, breaker.
2.1.2 Reflector
- The reflector is made with aluminum.
2.1.5 Angle (900/1200/1800) and number (2/3/4) of Light fixture depends on regulation. The
vertical angle can be adjusted within 10O.
5
Operating and Maintenance Manual BEACON
2.1.5 Heater
Temperature regulator function is preventing influence from temperature on each part in
lower part.
2.1.6 Remote control and monitoring of short circuit of lamp are possible.
6
Operating and Maintenance Manual BEACON
3. Function
7
Operating and Maintenance Manual BEACON
4.1 Installation
4.1.1 General
Anchor bolt or supporter in advance is installed in a construction site according to the
drawing.
4.2.2 The breaker for motor, heater and lamps is turned off. And Main breaker is turned on.
4.2.3 The operation switch is turned on in a control tower. If not, the terminal (CC1, CC) for
remote control has a short circuit.
4.2.4 The breaker for lamps is turned on. And then, lamps are turned on. They flash white
and blue with the angle of 180° each other
4.2.5 The breaker for motor is turned on. At that time, it should be operated a long way off
because the rotation part has a rotation.
8
Operating and Maintenance Manual BEACON
4.2.6 The breaker for heater is turned and temperature regulator is set to fixing
temperature. The standard for temperature has a 15°C, but is subject to that area.
5. Maintenance
9
Operating and Maintenance Manual BEACON
6. Material List
BEAON 1 (4 LAMPS-WHITE/GREEN)
2
3
BEAON 2 (3 LAMPS-WHITE/GREEN/YELLOW)
2 3
4
6
10
Operating and Maintenance Manual BEACON
NO PART NAME
1 Obstruction light
2 Light fixture
3 Color filter
4 Mounting bracket
5 Lower body
6 Heat exit valve
7 Power Relay
8 Current Relay
9 & 18 Temperature regulator
10 Fuse
11 MCCB (Main)
12 Magnet Contact
13 Terminal block (for input power)
14 Terminal block(For remote control & monitoring)
15 Slip ring/ Brush block
16 Motor
17 Condenser (for Motor)
19 Heater
11
Operating and Maintenance Manual BEACON
7. Drawing
7.1 Outline
12
Operating and Maintenance Manual BEACON
13