Installation Manual Radius 1000: Kongsberg Maritime Part No.: (Radius 1000) 603088
Installation Manual Radius 1000: Kongsberg Maritime Part No.: (Radius 1000) 603088
Installation Manual Radius 1000: Kongsberg Maritime Part No.: (Radius 1000) 603088
Installation Manual
RADius 1000
Kongsberg Maritime Part no.:
(RADius 1000) 603088
This manual describes the installation of the RADius 1000,
manufactured by Kongsberg Seatex AS and supplied by
Kongsberg Maritime AS.
179644/F 1
RADius 1000
Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A/0 15.05.04 FOS
B/1 29.10.04 TSW
C/2 06.12.04 TSW
D/3 07.02.05 TSW
E/4 08.09.05 CBM 06.10.05 TSW 06.10.05 TH
F/5 11.11.06 PLB 13.11.06 TH 13.11.06 TH
G
H
The original signatures are recorded on the company’s logistic data system.
Document history
2 179644/F
Installation Manual
Table of contents
1 INTRODUCTION....................................................................................................4
2 SPECIFICATIONS..................................................................................................5
2.1 Physical dimensions............................................................................................5
2.2 Power ..................................................................................................................5
2.3 Environmental specification ...............................................................................6
2.4 Cables..................................................................................................................6
3 INSTALLATION .....................................................................................................7
3.1 General information ............................................................................................7
3.2 Logistics..............................................................................................................8
3.3 Location of the system parts ...............................................................................9
3.3.1 The Interrogator Unit...................................................................................9
3.3.2 Controller Unit...........................................................................................10
3.4 Installation procedures ......................................................................................11
3.4.1 Mechanical installation..............................................................................11
3.4.2 Electrical installation .................................................................................12
4 INSTALLATION DRAWINGS............................................................................16
5 APPENDIX .............................................................................................................25
5.1 Bulgin connector assembly ...............................................................................25
179644/F 3
RADius 1000
1 INTRODUCTION
This manual contains the information necessary to install the
RADius 1000 on a vessel. For more detailed product
information, please refer to the RADius 1000 User's Manual.
RADius represents a new way of utilising technology in short
range and direction monitoring, and is mainly used in operations
where increased safety is crucial, like when controlling or
assisting automatic dynamic positioning (DP) of a vessel.
The RADius system is designed to operate close by structures
and other vessels and uses identifiable transponders to minimize
the risk of tracking false radar echoes. The system is capable of
detecting and measuring the distance to transponders within the
range of up to 1000 metres.
For information about installation of the RADius Transponder
please refer to the RADius 500/600 Transponder Installation
Manual, KM doc no 179645.
Caution Unless stated otherwise, all mounting equipment such as bolts,
screws, nuts, washers, etc., referred to within this document
are to be supplied by yard/customer.
4 179644/F
Installation Manual
2 SPECIFICATIONS
2.2 Power
179644/F 5
RADius 1000
Processing Unit
Enclosure material: ...............................................................Aluminium
Enclosure protection: ..................................................................... IP-30
Operating temperature range: ........................... -15 to +55ºC/5 to 131 F
Operating humidity:...................................................20 to 80% relative
Storage temperature range: ..............................-20 to +60ºC/-4 to 140 F
Storage humidity:.............................................................Less than 55%
6 179644/F
Installation Manual
3 INSTALLATION
179644/F 7
RADius 1000
3.2 Logistics
Inspect equipment for possible physical damage before
installation. Make sure that no damage is made to the cover of
the RADius 1000 Interrogator unit.
Safety
General safety guidelines must be followed when working in
mast and on deck.
Personnel qualifications
Trained electrical workers only.
Ship location
None.
8 179644/F
Installation Manual
10 179644/F
Installation Manual
The connectors on the Processing Unit for the serial lines are of
DB-9 male type. Pin layout:
RS-232 RS-422
Pin. no. Signal Pin no. Signal
1 N/C 1 N/C
2 RXD 2 RX+
3 TXD 3 TX+
4 N/C 4 N/C
5 REF 5 REF
6 N/C 6 N/C
7 RTS 7 TX-
8 CTS 8 RX-
9 N/C 9 N/C
12 179644/F
Installation Manual
The data cable from the Interrogator Unit to the terminal rail on
the Power/Connection Shelf has the following cable wiring:
The power cable from the Interrogator Unit to the terminal rail
on the Power/Connection Shelf has the following cable wiring:
179644/F 13
RADius 1000
14 179644/F
Installation Manual
179644/F 15
RADius 1000
4 INSTALLATION DRAWINGS
This chapter contains the outline drawings showing the mechanical
dimensions of the Processing Unit and the Interrogator Unit.
16 179644/F
Installation Manual
179644/F 17
RADius 1000
18 179644/F
Installation Manual
VGA
PPS
MOUSE
KEYB
Input : 100-240VAC/47-63Hz/100VA
AUX - Serial Fuse : 2A
Class1 : Must be connected to
grounded outlet only
Compass safe distance:
NET Steering Magnetic Compass : 1.1 m
Standard Compass : 1.9 m
179644/F 19
RADius 1000
Figure 7 Power and Data/LAN terminal rails for the Interrogator cables
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
TX+ TX- RX+ RX- Shield TX+ TX- RX+ RX- Shield TX+ TX- RX+ RX- Shield TX+ TX- RX+ RX- Shield
20 179644/F
Installation Manual
1
6
5 2
4 3
Power Data
Figure 11 Location of the data and power connectors on the Interrogator rear panel
1
6
5 2
7
4 3
Figure 12 Internal view of power connector used on the Interrogator Unit cable
179644/F 21
22
RADius 1000
85
10 Typ.
85
412
180
210
562 214
179644/F
Projection: Issued : 04.03.16 Date: 05.01.31 Rev. no: Scale : Not to scale
3
114 Xref file : Approved : Usage: Design by :
Drawing no: 3840-MA-011 Checked :
External KL
179644/F
R AD ius 1000
KONGSBERG
SEATEX
23
Installation Manual
24
A
RADius 1000
57,1
132,5 (3U)
482
465
3,5
443
3,5
33,6 430
179644/F
Projection: Issued : Date: Rev. no: 4 Scale : 1:5
99.05.03 04.11.25
Xref file : Approved : Usage: Design by :
Drawing no: 31438-MA-010 Checked :
Assey KL
Installation Manual
5 APPENDIX
Connector
main body
Retaining Sealing
ring cap clip
Screw
Gland
terminals
cage
Cable
Gland
Gland nut
Locking
ring
179644/F 25
RADius 1000
When inserting the screw terminal part into the connector main
body, be sure to rotate the part until it is locked before installing
the retaining ring. The flat part of the screw terminal must match
the corresponding flat part inside the connector main body. A
good way to ensure a correct installation is to rotate the screw
terminal body inside the connector main body until it locks and
can not be rotated more.
Caution If the screw terminal body is not correctly mounted in the
connector main body, the assembled connector will not be
waterproof.
26 179644/F