Notes:: Hold
Notes:: Hold
Notes:: Hold
1SD0P11
6"x3" TEMPERATURE CONTROL VALVE TO ENSURE MINIMUM FLOW
SURFACE AREA : 9456.0 ft^2
Down
AND KEEP B90-E-0119 HOT WHEN NOT IN USE.
OP : 880.0 PSIG 1"
4. ALL FIELD INSTRUMENTS ON THIS P&ID ARE PART OF RISK
OF
OT (IN/OUT) : 85.40 °F / 536.00 °F
SET @ 1050.0 PSIG
SLOPE
0003-
DP : 1050 PSIG AREA 4 UNLESS OTHERWISE NOTED.
D
3"J4"
CONSENT
CSC NO. B55-A-BA-755677-003.
HPF-
TRIM : 6SD0P02
PZV
OP : 130.0 PSIG FB + 1" V 6. VALVE CLOSED DURING HEATING CYCLE AND OPEN DURING
10001 B
8"-
OT(IN/OUT) : 572.00 °F / 350.00 °F 8" COOLING CYCLE.
NO POCKET
FREE DRAI
DP : 1050 PSIG 7. VALVE CLOSED DURING COOLING CYCLE AND OPEN DURING
DT : 622.00 °F / 15.00 °F HEATING CYCLE.
8"x4" CSC
TRIM : 6CS1U01
6"x3"
FB 8. LEVEL ALARM INDICATES ACCUMULATION OF GAS DUE TO TUBE
FI 1"
TTEN
LEAK ON B90-E-0119.
10001
9. TO ENSURE VENT DETAIL IS SAFE FOR OPERATOR AND
D
SPECIFICALLY AVOIDS SPUTTERING OF HOT OIL ONTO
CSC
WRI
6" OPERATOR.
FB
10. STEAM OUT CONDITION TO BE CONSIDERED :
FF
FIT 6"-
P-0042-
6SD0P02 15PSI@300°F (TUBE SIDE)
11. HOT OIL SHALL NOT BE DRAINED UNTIL IT IS COOLED TO 200°F
THE
10001
0.00-1400.00 GPM NOTE-3 TO AVOID DAMAGE TO RTR PIPING.
V H SET @ 940.0 PSIG H SET @ 554.00 °F 12. ZV AND SAFE LOCATION BUTTONS TO BE LOCATED AT LEAST
1" FF
7.5M BEYOND THE EDGE OF ANY FIRE HAZARDOUS ZONE.
THOUT
2" 2" 2"-
HPF-
0004-
1SD0P11
10"-
HO -
0154-
6CS1U01 PI TIC TIT
B90-BA-755699-001
13. PROVIDE MEANS FOR ACCESS TO THE VENT VALVE.
PI 10005 10007 10007 14. CYCLIC SERVICE.
6SD0P02
HOT OIL SUPPLY NOTE-15 2"-
P-0043-
6SD0P02 6SD0P02 1SD0P11 15. TRIPLE OFFSET BUTTERFLY VALVE.
10001 L SET @ 829.0 PSIG -50.00 - 600.00 ° F
WI
N
FE HOLD:
EC FF
0041-
DETAIL 27 1. LOCATION OF NEW REGENRATION GAS HEATERS TO BE
NG
10001 2" PI TI PIT TE
TI
CONFIRMED BY CLINT AFTER OPTIONS STUDY.
DRAWI
10005 10007
P-
10001 10003 10006
KV
6"-
1" MIN. 0-1300 PSIG +
2M 10035 LEGEND
1"
4 " 4 "
14" PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-004
D 14"-
P-0040-
6SD0P02 12"-
P-0037-
6SD0P02 SPECIFICATION SAES-L-005
EC EC B90-BA-755699-001 AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
S
THI
AIR FAILURE OPEN
2"
12" NOTE-14 VS -VIBRATION SWITCH
14"x12" HOT REGEN GAS OR AC/AFS -AIR TO CLOSE/AIR
PROCESS LINE VT -VIBRATION TRANSMITTER
3 1/
NOTE-5,7 COOLING REGEN GAS FAILURE STEADY XL -PILOT LIGHT
EC
AO/AFC INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
TO GAS DEHYDRATORS
PI TI AIR FAILURE CLOSE XS -LIMIT SWITCH
AIR LINE
FROM
TSO B90-D-0110A-D AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
10004 10005
FAILURE STEADY
1 1/2 " INSTRUMENT
DATA LOGGER POINT
NPUTS
6"-
P-0036-
6SD0P02 ELECTRICAL LINE AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.
EC B90-BA-755694-001 AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
4 "
I
DT -DENSITY TRANSMITTER
NED
X-MISC. A-ALARM
AT GRADE EC HOT REGEN GAS
ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC -FLOW CONTROLLER
MOUNTED INSTR.
TO CONDENSATE
OBTAI
FV -FLOW CONTROL VALVE
2" V DEHYDRATORS FCV -FLOW CONTROL VALVE
BOARD MOUNTED
4" 4" B90-D-0111A/B (SELF-ACTUATED) INSTRUMENT
4" 4"
EC EC FE -FLOW ELEMENT
EC EC 2" V R/G
FG -FLOW SIGHT GLASS XL STATUS LIGHTS
FHV -FLOW MANUAL CONT. VALVE R=RED, G=GREEN
BE
FHTd -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
REDUCER
FM -FLOW METER
MOTOR STATUS
PART,SHALL
FO -RESTRICTION ORIFICE ML
SPECTACLE PILOT LIGHT
B90-E-0119B PLATE-OPEN
FQI -FLOW TOTALIZER INDICATOR
FR -FLOW RECORDER
LOCAL MOUNTED
B90-E-0119A FT -FLOW TRANSMITTER INSTRUMENT
SPECTACLE
FY -FLOW RELAY
PLATE-CLOSED
HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
GATE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
GLOBE VALVE
6SD0P02
LV -LEVEL CONTROL VALVE RACK MOUNTED
1" D
CHECK VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
2"
2" D (SELF-ACTUATED)
PI PI PLUG VALVE
N
LG -LEVEL GAUGE GLASS ELECTRICAL
I
0039-
D 10006 10007 LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
BALL VALVE
LI -LEVEL INDICATOR
FULL,OR
DOUBLE DISC LR -LEVEL RECORDER INSTRUMENT
TI
P-
TI AIR SUPPLY REQUIRED
GATE VALVE LS -LEVEL SWITCH
V
14"-
10003 2" LT
PI TI 10004 ANGLE VALVE
-LEVEL TRANSMITTER
H
4" 4" LTd -LEVEL TRANSDUCER HIGH LOW
10002 10002 EC EC ML -MOTOR STATUS LIGHT L
PRESS RELIEF
MOV -MOTOR OPERATED VALVE
VALVE NA -ANNUNCIATOR TWO PEN RECORDER
3 1/2 " PB -PUSHBUTTON
NOTE-11 VACUUM RELIEF
N
10"-
HO -
0155-
6CS1U01
I
PC -PRESSURE CONTROLLER FF
EC VALVE FOUNDATION
PV -PRESS. CONTROL VALVE
FIELDBUS INSTRUMENT
ON
6CS1U01 1SD0U05 M PCV -PRESS. CONTROL VALVE
MOTOR OPERATED
B90-E-0119C VALVE (SELF ACTUATED)
REPRODUCTI
2" 2" 2" PdC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CDS P PISTON OPERATED PdI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
VALVE
6024 PdIC -PRESSURE DIFFERENTIAL (DCS) DISTRIBUTED CONTROL
INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
1" D CONTROL VALVE IN CONTROL ROOM
EC N PdIS -PRESSURE DIFFERENTIAL
INDICATOR SWITCH
P
BALL TYPE (DCS) DISTRIBUTED CONTROL
PdT -PRESS. DIFF. TRANSMITTER
2"-
CDS-
0064-
1SD0U05 C CONTROL VALVE SYSTEM, OPERATOR INACCESSIBLE
EC C 2" D PdTd -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
WITH POSITIONER
PG -PRESSURE GAGE
S (DCS) DISTRIBUTED CONTROL
SOLENOID VALVE PI -PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER IN FIELD
SAUDIARAMCO.NO
PR -PRESSURE RECORDER
SET @ 1050.0 PSIG VALVE NORMALLY PS -PRESSURE SWITCH
1-1/2"F2" DISTRIBUTED CONTROL
CLOSED PT -PRESSURE TRANSMITTER
V 1" PZV PX -PRESSURE POINT INTERCONNECTING LOGIC
+
6"-
HPF-
0002- 6"
1SD0P11 SLOPE 1 mm /480 mm 10002 A PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
B90-BA-755750-001 PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
AT GRADE
NO POCKET CSO RTD -RESIST. TEMP. DETECTOR
6"x2" (PLC) PROGRAMMABLE LOGIC
TO HP FLARE SI -SPEED INDICATOR
FB CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
3"x1-1/2" TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
SLOPE 1mm /480mm
OF
1-1/2"F2" 10009 S.C. -SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
PZV PRESSURE SEWER
TR -TEMP. RECORDER
PROPERTY
1" + CSO (PLC) PROGRAMMABLE LOGIC
V TS -TEMP. SWITCH
6" 10002 B TI CONTROLLER I/O POINT
SLOPE 1 mm /480 mm FB TI OWS -OILY WATER SEWER TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
10008 D -DRAIN TTd -TEMP. TRANSDUCER BY OPERATOR
10009
CSO V -VENT TW -THERMOWELL
6"x2"
N
NO POCKET
FB
FREE DRAI
SOLE
PIPING SYMBOLS AB-036227
6CS1U01
D
EQUIPMENT SYMBOLS AB-036305
ZC CSO 1" INSTRUMENT SYMBOLS AC-036950
3"
FB PIPING LAYOUT INDEX
0156-
THE
3"-
HO -
0162-
6CS1U01
D PLOT PLAN
1SD0P11 6CS1U01
1" V HYDROSTATIC TEST DIAGRAM
DETAIL 7
10"-
ARE
2" 2"
14"-
P-0034-
6SD0P02 2"-
HPF-
0006-
1SD0P11 DRAWING CONTROL FOR J.O.B1-10-12862 TD-718027
N
HEREI
10033
1 " 1 "
B90-BA-755688-001 C C
14" FF
REGEN GAS PI H SET @ 252.0 PSIG TIT
AO/AFC HH SET @ 287.00 PSIG
FROM MOL SIEVE DUST
NED
TSO 10010 10010 10"-
HO -
0157-
6CS1U01
14"x12" PI ZC PAHH PI
FILTER B90-D-0135A/B B90-BA-755699-001
NOTE-12 0.00 - 650.00 ° F
CONTAI
10011 10012 10012
2" 2" 2"
STEAM HOT OIL RETURN
OUT REVISION VALIDATION
N EC FF
1" D 1" D
PIT PIT TE
THIS REVISION NO. B IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
MIN. 2M FF
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
3"-
HO -
0161-
6CS1U01 10011 10012 10010
ON
0-1200 PSIG 0-1200 PSIG 10-12862-0001-000
IAS
NFORMATI
KV
+ 10" 2 "
NOTE-11 10" 10"x6" 10"x6" 10" NOTE-11 DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
10034
(DESIGN AGENCY) x REQUIRED (SAUDI ARAMCO)
EC
C
L27
I
SP EC B 09/01/19 ISSUED FOR 60% FEL-3 REVIEW
NOTE-5 & 6
2" 2" D
THE
6"
JOB ORDER/EWO NO.
1" 1" THIS REVISION IS NOT TO BE USED FOR
10-12862-0001 CONSTRUCTION UNTIL CERTIFIED AND DATED
2"-
HO -
0160-
6CS1U01 D 2"
D FG
SAUDI ARABIAN OIL COMPANY
AND
2" D 2" D 10002 1"
6CS1U01
6CS1U01
DRAWING TYPE
2"-
CDS-
0065-
1SD0U05
1SD0U05
D PIPING & INSTRUMENT DIAGRAM PID
2"-CDS-0066-
1SD0U05
NG
2"
REGENERATION GAS HEADER-TRAIN 1
6022
DRAWI
CDS
6023
CDS
1SD0U05
2"-
CDS-
0067-
1SD0U05
NGL RECOVERY AREA
OWS
SHAYBAH SAUDI ARABIA
4 "
6025
NOTE 14
S
CDS
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
THI
12"-
P-0038-
6SD0P02
EC