Design of Steel Structure (20CET-312)

Assignment: -2

(Group-A)
Maximum Marks: 10

Note: Make neat diagrams and write the proper steps of the solutions.

Mapped
Ques No. Question Marks
CO
A rolled steel beam section ISHB 350 @0.674 kN/m is used as a
1 stanchion. If the unsupported length of the stanchion is 4 m, determine 2 CO4
safe load carrying capacity of the section.
Design a laced column 10m long to carry a factored axial load of 1100
kN. The column is restrained in position but not in direction at both the
2 ends. Provide single lacing system. Use 2 channel section placed back- 3 CO4
to-back. assume Fe 410 and bolts of grade 4.6. Design the lacing system
with bolted connection.
Design a rolled steel beam section column to carry an axial load 1200
3 kN. The column is 3 m long and adequately restrained in position but 2 CO4
not in direction at both ends.
Design a simply supported beam to carry a uniformly distributed load
of 44 kN/m. The effective span of beam is 8 meters. The effective
4 3 CO5
length of compression flange of the beam is also 8 m. The ends of beam
are not free to rotate at the bearings.
Design of Steel Structure (20CET-312)

Assignment: -2

(Group-B)
Maximum Marks: 10

Note: Make neat diagrams and write the proper steps of the solutions.

Mapped
Ques No. Question Marks
CO
A rolled steel beam section ISMB 400 @604.3 N/m is used as a
1 stanchion. If the unsupported length of the stanchion is 4 m, determine 3 CO4
safe load carrying capacity of the section.
Design a laced column 8m long to carry a factored axial load of 1600
kN. The column is restrained in position but not in direction at both the
2 ends. Provide single lacing system. Use 2 channel section placed back- 3 CO4
to-back. assume Fe 410 and bolts of grade 4.6. Design the lacing system
with bolted connection.
Design a rolled steel beam section column to carry an axial load 1100
3 kN. The column is 4 m long and adequately restrained in position but 2 CO4
not in direction at both ends.
The effective length of compression flange of simply supported beam
ISMB 500, @0.869 kN/m is 8 m. Determine the safe uniformly
distributed load per meter length which can be placed over the beam
4 2 CO5
having an effective span of 8 meters. Adopt maximum permissible
stresses as per IS 800-2007. The ends of beam are restrained against
rotation at the bearings.