WELDER QUALIFICATION TEST CERTIFICATE

FOR INTERNAL CAP

Welder Name : SUBHI Stamp no. : WAS-001


Welding Process : GTAW Type : Manual
WPS No. : CAP/TPI -1 Thickness : 3.91 mm
Base Material(s) Welded : SA/A 53 GRADE B Certy No : QC-W-001

Manual or Semi automatic Variables for Each Process Actual Value Range Qualified
(QW-350)
Backing (metal, weld metal, welded from both sides, NONE NONE
flux, etc.) (QW-402)
ASME P-No (QW-403) P No. 1 to P No. 1 P No. - P No.11/P No.4X
Plate Pipe (enter diameter, if pipe) NPS Ø 2" NPS Ø 2 ½" & OVER
Filler Metal Specification
SFA No. SFA - 5.18 SFA - 5.18
AWS Classification (QW-404) ER. 70 S G ALL CLASSES IN ABOVE SPEC
F-No. F-No.6 / F-No.4 F-No.6 / F-No 1 - 4
Consumable Insert for (GTAW) N/A N/A
Weld Deposit Thickness for each
Welding Process (GTAW) 3.91 mm 7.82 mm
(SMAW) - -
Welding Position (QW-405) 6 (Six) G ALL
Progression (uphill / downhill) UPHILL UPHILL
Backing Gas for GTAW (QW-408) YES (ARGON 99.9%) YES / NO
GMAW Transfer Mode (QW-409) N/A N/A
Electrical Characteristic (QW-409)
Current DC DC
Polarity STRAIGHT POLARITY (GTAW) STRAIGHT POLARITY (GTAW)
- -

GUIDED BEND TEST RESULT


Type and Figure No. Results
N/A N/A
N/A N/A
N/A N/A
N/A N/A

Visual Examination Result : ACCEPTANCE Date of RT : June 7, 2014


Radiographic Test Result : ACCEPTANCE Refresh -
Radiographic Test Conducted by : PT. RADIANT UTAMA INTERINSCO test date : June 10, 2014
Welding Test Conducted by : PT. Waskita
Mechanical Test Conducted by : PT. Waskita
Laboratory Test No. :N/A

We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in
Accordance with the requirements of section IX of the ASME Code.

Prepared by Acknowladge by Approved by


PT waskita PT Chandra Asri Petrochemical Tbk.

Yadi Madyatmo Supiyanin Muchtar


QA / QC Inspector Site Manager Workshop Manager Static Insp Section Manager

C:\Data CAP\Form\Welder\Pug