Exflow Leaflet
Exflow Leaflet
Exflow Leaflet
Fields of application
Process gas measurement or control in (petro-) chemical industries
Fuel cell technology
Gas distribution systems
Hydrogenation processes
Gas consumption measurement for internal accounting
Heating or biogas production
Example of a multi-channel E-8000 power supply/readout F-106AX Ex-protected Mass Flow Meter for high flow ranges
system (to be located in the safe area)
Technical specifications Models and flow ranges (based on N2)
Measurement / control system Mass Flow Meters (MFM); PN100 (pressure rating 100 bar)
Accuracy (incl. linearity) standard: ±1% FS; other on request Model min. flow max. flow
(based on actual calibration) (for flow > 1000 m3n/h contact factory)
F-110CX 0,15…7,5 mln/min 0,19…9,5 mln/min
Turndown 1 : 50 (2…100%)
F-111BX 0,3…15 mln/min 0,4…20 ln/min
Repeatability < ±0,2% Rd
F-111AX 0,1…5 ln/min 2…100 ln/min
Time constant 5 seconds
F-112AX 0,8…40 ln/min 5…250 ln/min
Operating temperature EX-FLOW sensor: -10…+70°C;
XB-coil: -40…+ 65°C F-113AX 4…200 ln/min 25…1250 ln/min
XC-coil: -40…+ 65°C F-116AX 0,4…20 m3n/h 4…200 m3n/h
Temperature sensitivity zero: < ±0,05% FS/°C; F-116BX 1…50 m3n/h 7,5…375 m3n/h
span: < ±0,05% Rd/°C
For ranges of 200, 400 or 700 bar rated MFMs please contact factory.
Leak integrity tested < 2 x 10-9 mbar l/s He
Attitude sensitivity max. error at 90° off horizontal 0,2% High-Flow MFMs; PN10 / PN16 / PN25 / PN40 / PN100
at 1 bar, typical N2
Model min. flow max. flow
Warm-up time 30 min. for optimum accuracy;
F-106AX/F-107AX/F-117AX 0,4…20 m3n/h 4…200 m3n/h
2 min for accuracy ± 2% FS
F-106BX/F-107BX/F-117BX 1…50 m3n/h 10…500 m3n/h
Material (wetted parts) stainless steel 316L or comparable F-106DX/F-107DX/F-117DX 3,6…180 m n/h 3
36…1800 m3n/h
Process connections compression type or face seal couplings; F-106EX 8…400 m3n/h 80…4000 m3n/h
wafer type on series F-106;
F-106FX 14…700 m3n/h 140…7000 m3n/h
DIN or ANSI flanges on series F-107
F-106GX 22…1100 m3n/h 220…11000 m3n/h
Seals standard: Viton®
options: EPDM, FFKM (Kalrez®), FDA and USP Class VI
approved compounds Mass Flow Controllers (MFC); PN64 / PN100
Ingress protection (housing) IP65 Model min. flow max. flow
F-200CX/F-210CX 0,19…9,5 mln/min 0,19…9,5 mln/min
Electrical properties
F-201CX/F-211CX 0,3…15 mln/min 0,4…20 ln/min
Output signal 15…20 mA (linear)
Terminal connection, cable gland M16x1,5 F-201AX/F-211AX 0,1…5 ln/min 2…100 ln/min
I/O signals via PS/Readout analog: 0…5 Vdc, 0…10 Vdc, 0…20 mA, 4…20 mA; F-202AX/F-212AX 0,6…30 ln/min 5…250 ln/min
(located in safe area) digital: RS232, PROFIBUS DP, DeviceNet™, Modbus F-203AX/F-213AX 4…200 ln/min 25…1250 ln/min
RTU or ASCII, PROFINET, EtherCAT®, FLOW- BUS
F-206AX/F-216AX 0,4…20 m3n/h 4…200 m3n/h
XB-coil Coil voltage max. 28 V/110mA;
295 Ohm at 20°C, cable gland M20x1,5 F-206BX/F-216BX 1…50 m3n/h 7,5…375 m3n/h
XC-coil Coil voltage max. 24 V; Contact factory for max. Kv-values (depending of coil type).
65 Ohm at 20°C, cable gland M20x1,5;
Pmax = 9W at 20°C MFCs for high-pressure / high-ΔP applications; PN400
Technical specifications subject to change without notice. Model min. flow max. flow
Related drawing 9.27.002N. No modifications permitted without approval of authorised person.
F-230MX 0,2…10 mln/min 10…500 mln/min
F-231MX 10…500 mln/min 0,2…10 ln/min
F-232MX 0,2…10 ln/min 2…100 ln/min
For ranges of 700 bar rated MFCs please contact factory.
F-112AX Mass Flow Meter F-202AX Mass Flow Controller F-107CX Mass Flow Meter for high flow ranges
(flanged type)
Model number identification
F - N N NAA - HEE - NN - A
Bronkhorst High-Tech designs and manufactures innovative instruments and subsystems for low-flow measurement
and control for use in laboratories, machinery and industry. Driven by a strong sense of sustainability and with
many years of experience, we offer an extensive range of (mass) flow meters and controllers for gases and liquids,
based on thermal, Coriolis and ultrasonic measuring principles. Our global sales and service network provides
local support in more than 40 countries. Discover Bronkhorst®!