BOQ FOR CONSTRUCTION OF SWIMMING POOL AT YPS PATIALA

(CIVIL,PUBLIC HEALTH AND ELECTRICAL WORKS)


PART- I :- CIVIL WORKS
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
EARTH WORK
1 Earth Work in excavation in foundation, trenches, etc in all kind of 2736.11 Cum
soil where pick-jumper work is not involved hand not exceeding
2.0 metrs in depth including dressing of bottom and sides of
trenches, stacking the excavated soil clear from the edge of the
excavation and subsequent filling around masonry in 15cm layers
with compaction including disposal of all surplus soil as directed
with in lead of 30 metres

2 Extra for excavating in foundation, trenches, etc in all kind of soil 744.06 Cum
from 2.0 to 3.00 metrs in depth including dressing of bottom and
sides of excavated soil clear from the edge of the
excavation.(Rate is over corresponding basic item for depth upto
1.5 metre)
3 Extra for excavating in foundation, trenches, etc in all kind of soil 441.62 Cum
from 3.0 to 4.50 metrs in depth including dressing of bottom and
sides of excavated soil clear from the edge of the
excavation..(Rate is over corresponding basic item for depth upto
1.5 metre)
4 Filling available excavated earth (excluding rock) in trenches, 980.00 Cum
plinth,sides of foundations etc in layers not exceeding 20 cm in
depth, consolidating each deposited layer by ramming and
watering lead upto 50m and lift upto 1,5 m. Any surplus soil shall
be disposed off in school premises free of cost.

5 Supplying and filling in plinth with sand under floors, including 580.00 Cum
watering,ramming,consolidating and dressing complete.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
6 Providing and applying Anti Termite Treatment using pre 750.00 Sqm
constructional chemical treatmentmeasures as per 6313-2001
(Part2) & using Chemical containg chloropyifors syastemic
insecticide diluted to manufactures specifications (i) in foundation
pits,by treating the bottom & sides upto height of 300 mm by
uniformly spraying solution @ 5 litre/ Sqm (ii) in rifill earth on both
sides of all built up area up walls @ 7.5 litre/ Running metre
(width 300mm, depth 450mm ) (iii) before laying the floor by
uniformly sprinkling the top surface of the consolidated earth with
in the outer perimeter @ 5 litre soluution per Sqm.

PLAIN CEMENT CONCRETE


7 Plain Cement Concrete in foundations M15-(1:2:4) using 20 mm 190.00 Cum
gauge stone aggregate.
8 Plain Cement Concrete in foundations 1:4:8 with stone aggregate 350.00 Cum
40mm gauge
REINFROCED CEMENT CONCRETE,CENTRING & SHUTTERING
9 Reinforced Cement Concrete M-30 mechanically mixer as per IS 980.00 Cum
: 1791 and vibrated by needle vibrator but excluding
reinforcement steel,centring and shuttering in foundationd and
plinth Level.
10 Reinforced Cement Concrete M-30 mechanically mixed using 60.00 Cum
concrete mixer as per IS : 1791 and vibrated by needle vibrator
but excluding reinforcement steel,centring and shuttering in
Super structure.
11 Reinforced Cement Concrete M-25 mechanically mixed using 130.00 Cum
concrete mixer as per IS : 1791 and vibrated by needle vibrator
but excluding reinforcement steel,centring and shuttering in
Super structure.
12 Centering and shuttering for faces of concrete foundations and 350.00 Sqm
foundation beam & plinth beam ( vertical or battering)
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
13 Centering and shuttering for faces of walls, partitions, retaining 1400.00 Sqm
walls and the like ( vertical or battering including attached
pilasters buttresses etc.)
14 Centering and shuttering including for Columns ( Square or 500.00 Sqm
rectangular or poly gonal in plain.
15 Centering and shuttering for sides and soffits of beams, 130.00 Sqm
beams,launching,girders, bressumers and lintels.
16 Centering and shuttering for flat surfaces such as Suspended 980.00 Sqm
floors, roofs, landings,chajjas,shelves etc.
17 Steel reinforcement with Thermo-Mechanically-Treated bars of 98000.00 Kg
grade Fe-500D for R.C.C. work including straightening, cutting,
bending,placing in position and binding all complete at all levels.
WOOD WORK
18 Providing and fixing ISI marked flush door shutters conforming to 10.00 Sqm
IS : 2202 (Part-1) decprativetype, core of block board
construction with frame of 1st class hard wood and well matched
teak 3 ply veneering with vertical grains or cross bands and face
veneers on both faces of shutters 35 mm thick including ISI
marked Stainless Steel butt hinges with necessary screws.

19 Providing & fixing in position with Teak Wood doors, windows 25.00 Sqm
35mm thick Panelled, glazed or glazed and panelled shutters
including hinges,screw and cords etc. complete

20 Providing and fixing in position Chowkats of Teak Wood


confirming to ISI specification no. 1003 m kiln seasoned of doors
and windows including iron hold fasts, corner straps,cleats, stops
bolts for hold fasts etc,complete fixed in position (Section 60mm x
150 mm)
A Single Rebate 20.00 RM
B Double Rebate 20.00 Rm
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
21A Providing & Fixing glass panes (5.5mm thick) with nails and putty 20.00 Sqm
or wooden strip complete in all respect
21B Providing & fixing bevelled glass 8mm thick 20.00 Sqm
22 Providing and fixing teak wood moulding 50mm x 12mm to door
windows chowkats with iron screws fixed in position complete as 45.00 Rm
per design and shape required.
23 Providing & fixing 6" stainless steel bow handles ISI marked on 60 Each
door & window frames complete in all respect as per the
directions
24 Providing & fixing 1'-3" stainless steel handle ISI marked on door 2 Each
& window frames complete in all respect as per the directions for
main door shutters
25 Providing & fixing 6" stainless steel tower bolts ISI marked on 12 Each
door & window frames complete in all respect as per the
directions
26 Providing & fixing 8" stainless steel tower bolts ISI marked on 12 Each
door & window frames complete in all respect as per the
directions
27 Providing & fixing 12" stainless steel tower bolt ISI marked on 20 Each
doors & windows complete in all respect as per the directions

28 Providing & fixing SS cleats & stopper of standard size & shape 20 Each

29 Providing & fixing SS sliding bolt of approved size & design

A 12" long 5 Each

B 8" long 5 Each

BRICK WORK
30 Brick Work with first class burnt bricks laid in cement sand mortar 7.00 Cum
1:4 in foundation and plinth.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
31 Brick Work with first class burnt bricks laid in cement sand mortar 110.00 Cum
1:6 in foundation and plinth.
32 Brick Work with first class burnt bricks laid in cement sand mortar 150.00 Cum
1:6 in Super structure.
33 Brick Work with first class burnt bricks laid in cement sand mortar 50.00 Sqm
1:4 in foundation and plinth.
34 Brick Work with first class burnt bricks laid in cement sand mortar 150.00 Sqm
1:4 in Super Structure.
STRUCTURAL STEEL WORK
35 Structural steel work in single section, fixed with or without 2500.00 Kg
connecting plate,including cutting,hoisting,fixing in position and
applying a priming coat of approved steel primer all complete.

36 Steel work welded in built up sections/ framed work, including


cutting,hoisting,fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required.
A In stringers,treads, landings etc. of stair cases, including use of 80.00 Kg
chequred plate where ever required, all complete.
B In gratings, frames, guard bar, ladder, railings, brackets, gates 600.00 Kg
and similar works.
FLOORING
37 Cement Concrete 40mm thick laid in cement concrete topping 175.00 Sqm
1:2:4 using 20mm graded stone aggregate.
38 Providing and laying screed 40mm thick laid in cement concrete 1010.00 Sqm
in 1:8:16 to be laid below the topping using mechanical mixer for
mixing of material
39 Providing and laying Vitrified anti skid floor tiles 405mm x 405mm 780.00 Sqm
size double charged premium quality with water absorption less
than 0.08 % and confirming to IS:15622 of approved make in all
colours and shades laid on 20mm thick cement mortar 1:4 for
new flooring.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
40 Grouting the joints of flooring tiles having joints of 3 mm width, 790.00 Sqm
using epoxy grout mix 0.70 kg of organic filler of desired shade
(0.10 kg of hardener and 0.20 kg of resin per kg). Including
filling/grouting and finishing complete.
41 Providing and laying first class ceramic glazed wall tiles 645.00 Sqm
confirming to IS :15622 of size 600x300mm in dado on 12mm
thick cement sand plaster 1:3 in base and joined with white
cement slurry in joints including bevelled crners.
42 Kota Stone flooring 20mm to 30mm thick over 12.5mm thick 230.00 Sqm
base of cement mortar 1:3 laid and jointed with neat cement
slurry mixed with pigment to match the shade of stone including
rubbing and polshing.
43 Kota Stone slabs 20mm thick in risers of steps,skirting,dado laid 11.00 Sqm
over 12.5mm thick base of cement mortar 1:3 laid and jointed
with neat cement slurry mixed with pigment to match the shade
of stone including rubbing and polshing.
44 Extra for pre finished nosing in treads of steps of Kota stone/ 55.00 Rm
sand stone slabs.
45 Providing and fixing Glass mossaic tiles on finished plain wall 1320.00 Sqm
surface of size 200 mm x 200 mm x 4 mm in all colour, design ,
fixing in customize design as per direction of Engineer-in-
Charge. The glass mosaic tiles to be fixed on the wall surface
with the help of approved adhesive applied at the rate of 2.5 kg
per sqm and grouting of the same. or Johnsons plain tiles of
internal swimming pool surfaces.
46 Providing and laying Polished coloured Granite stone flooring in 180.00 Sqm
required design and pattern in linear as well as curvilinear
portions of the building all complete with 18 mm thick stone slab
over 20 mm thick base 0f cement mortar 1"4 laid and jointed with
cement slurry and pointing with white cement slurry admixed with
pigment of matching shade all complete.(i) Polished Granite
Stone Slab Colour of Black,Cherry/Ruby red or equivalent.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
WATER PROOFING TREATMENT
47 Tile Terracing Consisting of tiles 22.86 cmx11.43 cm x 3.81 cm 310.00 Sqm
laid over 25mm mud plaster, 75 mm mud filling on another layer
of 25 mm mud plaster including Two coats of biyumen laid hot @
1.65 kg/ Sqm on top of RCC slab including grouting with cement
sand mortar 1:3.
48 Cement sand flush Pointing on tile terracing with cement sand 310.00 Sqm
mortar 1:3.
49 Providing and fixing 110 mm dia SWR UPVC Rain water pipe 141.00 Rm
with clamps.
50 Providing and fixing on wall face unplasticised - PVC moulded 30 Each
fittings UPVC Plain Bend 110 mm
51 Top Khura 45 x 45 cm for Rain Water Pipe in 25 mm thick 15 Each
cement concrete 1:2:4 over 50mm thick cement concrete !:5:10

52 Bottom Khura on ground 120 x60 cm for Rain Water Pipe in 50 15 Each
mm thick cement concrete 1:2:4 over 75mm thick cement
concrete !:5:10
53 Cement Concrete 1:2:4 gola 7.5cm x7.5cm quardrant along 90.00 Rm
junction of roof with parapet wall finished smooth, where specially
specified.
54 Providing and fixing in position PVC water stps confirming to IS: 1100.00 Rm
12200 for Construction/expansion joints between two RCC
members and fixed to reinforcement with binding wire before
pouriung concrete etc.( Rubber weather bars 150mmx5mm)
55 Water Proofing coating of K-10 Damp flex of ( Parex Group) shall 2700.00 Sqm
be applied as per manufactures specifications on RCC walls both
sides inner & outer, Raft before & after & RCC drain etc for check
any cracks & leakage.
CEMENT SAND PLASTERING & FINISHINGS
56 6 mm thick Cement Plastering wth cement sand mortar1:3 on 590.00 Sqm
Ceiling
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
57 12 mm Thick Cement Sand Plastering with cement sand mortar 770.00 Sqm
1:4 on outer side with Water proofing
58 Extra for providing and mixing water proofing material in cement 770.00 Sqm
plaster work in proportion recommended by the manufacturers.

59 15 mm Thick Cement Sand Plastering with cement sand mortar 325.00 Sqm
1:4 on inner side
60 Preparation of plastered or concrete surface for painting using 1710.00 Sqm
Acrylic Wall Putty by applying two or more coats to get required
finish including priming coat to make an even surface .
61 Distempering with Acrylic washable distemper of approved brand 755.00 Sqm
and manufacture to give even shade:New work(two or more
coats) over and including water thinnable priming coat with
cement primer.
62 Finishing walls with Acrylic Smooth exterior paint of required 955.00 Sqm
shade :New work(two or more coat applied @ 1.67 ltr/10 sqm
over and including priming coat of exterior primer @2.20 kg/ 10
sqm.
63 Painting wood work with Deluxe Multi Surface Paint of required 90.00 Sqm
shade. Two or more coat applied @ 0.90 ltr/10sqm over an
under coat of primer applied @ 0.75 ltr / 10 sqm of approved
brand and manufaturers.
64 Painting Steel work with Deluxe Multi Surface Paint to give an 125.00 Sqm
even shade. Two or more over coat applied @ 0.90 ltr/10sqm
over an under coat of primer applied @ 0.80 ltr / 10 sqm of
approved brand and manufaturers.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
65 Polishing on wood work with ready mixed wax polish of approved 80.00 Sqm
brand and manufacture on new wood work including surface
preparation complete in all respects
ALUMINIUM WORK AND GLAZING
66 Providing and fixing aluminium work for doors, windows,
ventilators and partition with extruded built up standard tubular
sections/ appropriate Z section and other sections of approved
make conforming to IS: 733 and IS:1285,fixing with dash
fasteners of required dia and size, including necessary filling up
the gaps at junctions, i.e. at top, bottom and sides with required
EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically
wherever required including cleat angle Aluminium snap beading
for glazing / paneling,C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of
Engineer-in-Charge (Glazing, paneling and dash fasteners to be
paid for Separately) for fixed position

A Fixed portion and chowkaths 250.00 Kg

B For shutters of doors, windows & ventilators including hinges/ 220 Kg


pivots etc.
67 Polyester powder coated aluminium (minimum thickness of 470.00 Kg
polyester powder coating 50 micron
68 Providing and fixing glazing 5mm thick in aluminium door, 100 Sqm
window, ventilator shutters and partitions etc,with EPDM
rubber/neoprene gasket etc.complete as per the architectural
drawings and the directions of engineer-in-charge . (Cost of
aluminium snap beading shall be paid in basic item):
68A Providing & fixing 6mm thick decklite board 60 Sqm
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
69 Providing and fixing double action hydraulic floor spring of 4 Nos.
approved brand and manufacture conforming to IS : 6315, having
brand logo embossed on the body / plate with double spring
mechanism and door weight upto 125 kg, for doors, including
cost of cutting floors, embedding in floors as required and making
good the same matching to the existing floor finishing and cover
plates with brass pivot and single piece M.S. sheet outer box with
slide plate etc.complete With stainless steel cover plate minimum
1.25 mm thickness
70 Providing and fixing rigid PVC grating 300mm wide for drain 150 RM

71 Providing and fixing false ceiling of all height 200 Sqm


600mmx600mmx0.5mm metal ceiling perforated tiles without
Fleece Powder coated of 60 to 70 microne type OREO GI laid in
grid system. The frame work comprise of made of GI 120 GSM
coating with minimum 0.3mm thickness main runner spaced at
1200mm centres securely fixed to the structural soffit by
approved hangers at 1200mm maximum centres. Hangersa (GI
wire of 4mm dia) to be fixed buapproved roof plug, level adjusters
and screw etc. The last hanger at the end of each main runner
should not be greater than 450mm from the adjacent wall. Flush
fitting 1200mm long cross tees (with double stiching) to be
interlocked between main runners at 600mm centres to form
1200x600mm modules. Cut across tees longer than 600mm to
be supported independently. 600x600mm modules to be formed
by fitting 600mm long flush fitting cross tees centrally between
the 1200mm cross tees. Perimeter trim to be wall angle secured
to walls at 450mm maximum centres. Well height of Cross toe
24mmx26mmx32mm complete in all respects as per specification.

72 Stylam Fibre Board Partition/Cubicles 12mm Thick with Doors & 75.00 Sqm
necessary fitting as per darawing & design
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
73 Providing precast cement concrete Jali 1:2:4, 50mm thick (1 100.00 Sqm
cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal
size) reinforced with 1.6 mm dia mild steel wire including centring
and shuttering, roughening cleaning, fixing and finishing in
cement mortar 1:3 (1 cement: 3 fine sand) etc. complete
excluding plastering of the jambs, sills and soffits
74 Providing and laying 60 mm thick factory made cement concrete 200.00 Sqm
interlocking Paving blocks of M-35 grade manufactured by block
making machine equipped with steel mould clamped to a strong
vibratory table with hydraulic pressure for compaction of concrete
as per IRC SP 63 -2014 and of approved size and design / shape
laid in Ordinary Grey Colour and pattern over and including 40
mm thick compacted bed of coarse sand, filling the joints with
fine sand etc, all complete as per directions

SUB TOTAL
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
PART-II :- PUBLIC HEALTH
EARTH WORK
1 Earth Work in excavation in trenches pipe lines straight or open 290.00 Cum
cutting etc in all kind of soil where pick-jumper work is not
involved nand not exceeding 2.0 metrs in depth including
dressing of bottom and sides of trenches, stacking the excavated
soil clear from the edge of the excavation and subsequent filling
around masonry in 15cm layers with compaction including
disposal of all surplus soil as directed with in lead of 30 metres

2 Providing and fixing CP Brass bottle trap 32mm dia with 40 mm 20.00 Each
seal of approved make.

3 Providing and fixing 600x450 mm beveled edge mirror of superior


glass (of approved quality) complete with 6 mm thick hard board
ground fixed to wooden cleats with C.P. brass screws and
washers complete.

A Size 600mmx450mm 6 Each


B Size 1500mmx600mm or any other size 2 Each
4 Providing and fixing toilet paper holder :C.P brass 12 Each

5 Providing and fixing in position Chinaware extended wall mounted 12 Each


E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap
of approved make (to the approval of the Engineer-in-charge)
with or without 10 ltr. chinaware matching flushing cistern and
seat cover complete in all respect of make: Hindware Enigma
Star White.

6 Providing and fixing jet spray with 2'-6" long PVC pipe with PTMT 12 Each
Nut.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
7 Providing and fixing in position vitreous Chinaware white lIndian 8 Each
make large flat back or angular lipped front urinal 375 x 390 x
590 mm of approved make (to the approval of the Engineer-in-
charge) consisting of C.P. brass Urinal waste Coupling dome
type 32mm outer length 75 mm , C.P. brass Urinal Spreader
Ocular-Regular and C.P. brass tube connection 300 mm long
complete. Make :Hindware Enigma Star White.

8 Extra for providing and fixing G.I. 32mm waste pipe for urinal 8 Each
including elbow, reducer etc complete in all respect
9 Vitreous white Chinaware Partition-Make:Hindware Star White 8 Each
Large partition size 75 x 16.5 x 36.5 cm
10 Providing and fixing C.P. brass Urinal Spreader Ocular-Regular 8 Each
complete with fittings for urinals complete

11 Providing and fixing PTMT urinal cock of approved quality and 8 Each
colour.15 mm nominal bore, 80 mm long, 42 mm high and 30mm
wide with BSP female threads weighing not less than 48 gms
12 Providing and fixing in position vitreous chinaware white lavatory 12 Each
suites of approved chinaware white lavatory suites of approved
make (to the approval of Engineer-in-charge) including Rack Bolt
Screw Pair 115mm longwithout CP fittings complete in all
respect.make : Garnet Star white. Size 630mm x 500mm (above
counter oval Shape)
13 Providing and fixing in position C.P elbow action pillar tap of 12 Each
approved make
14 Providing and fixing in position 32 mm dia G.I waste pipe 20 Each
embedded in wall upto floor level including cost of fittings
complete as required
15 Providing and fixing in position C.P. brass overhead shower 1 12 Each
flow with shower arm with 15mm i/d inlet of approved make
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
16 Providing and fixing in position towel rails / ring of approved make
(to the approval of Engineer-in-charge ) fixed in with rawl plugs
embedded in walls with brass screws complete in all respect.

A C.P. brass towel Rails size 15mm dia 610 mm long. 8 Each

17 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,


having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, including fixing the pipe
with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge. Internal work -
Exposed on wall Make : Supreme as per IS: 15778.

A CPVC SDR 11 pipe & fiittings- 15 mm nominal dia 75.00 Rm

B CPVC SDR 11 pipe & fiittings- 20 mm nominal dia 130.00 Rm

C CPVC SDR 11 pipe & fiittings- 25 mm nominal dia 110.00 Rm

18 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)


pipes,having threaded fittings this includes thermal stability for
hot & cold water supply including all CPVC plain & brass
threaded fittings this includes jointing of pipes & fittings with one
step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge.External
Works.Make : Supreme as per IS: 15778.
A CPVC SDR 11 pipe & fiittings- 25 mm nominal dia 160.00 Rm
B CPVC SDR 11 pipe & fiittings- 32 mm nominal dia 70.00 Rm

C CPVC SDR 11 pipe & fiittings- 100 mm nominal dia 125.00 Rm


SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
19 Providing and fixing C.P. brass shower rose with 15 or 20 mm 12 Each
inlet 150 mm diameter
20 Constructing masonry Chamber 60x60x75 cm inside, in brick 1 Each
work in cement mortar 1:4 for sluice valve, with C.I. surface box
100mm top diameter, 160 mm bottom diameter and 180 mm
deep ( inside) with chained lid and RCC top slab 1:2:4 mix i/c
necessary excavation, foundation concrete 1:5:10 and inside
plastering with cement mortar 1:3,mix 12 mm thick, finished with
a floating coat of neat cement complete as per standard design
With common burnt clay F.P.S.(non modular) bricks of class
designation 7.5
21 Providing and placing on terrace (at all floor levels) polyethylene 2000 Ltr
water storage tank, IS : 12701 marked, with cover and suitable
locking arrangement and making necessary holes for inlet, outlet
and overflow pipes but without fittings and the base support for
tank 1000 Ltr

22 Providing and fixing C.P. brass stop cock (concealed) of standard 20 Each
design and of approved make confirming to IS: 8931 15 mm
nominal bore
23 Providing and fixing C.P. brass angle valve for basin mixer and 42 Each
geyser points of approved quality confirming to IS: 8931 make :
15mm nominal bore
24 Providing and fixing PTMT stop cock of approved quality and 24 Each
colour. 15 mm nominal bore, 86 mm long, weighing not less than
88 gms
25 Providing and laying cement concrete 1:5:10 (1 cement : 5
coarse sand : 10 graded stone aggregate 40 mm nominal size)
all-round Upvc pipes including bed concrete as per standard
design
A 110 mm diameter Upvc pipe 250.00 Rm
B 160 mm diameter Upvc pipe 210.00 Rm
C 200 mm diameter Upvc pipe 155.00 Rm
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
26 Providing, laying in trenches to correct gradient and alignment
and jointing of UPVC pipes having ISI specification IS:15328-
2003 class-SN-8 marked class-SN-8 marked make Supreme,
Finolex,good on them and laying the same in trenches to correct
alignment and gradients,cutting and jointing,testing for water
tightness and making good the leakages and defects including
cost of specials (Specials and Solvent should be of same make
as that of pipes) complete in all respects.
A 110 mm diameter Upvc pipe 250.00 Rm
B 160 mm diameter Upvc pipe 210.00 Rm

C 200 mm diameter Upvc pipe 155.00 Rm

27 Providing and laying cement concrete 1:5:10 graded stone


aggregate 40 mm nominal size) up to haunches of Upvc pipes
including bed concrete as per standared design.
A 110 mm diameter Upvc pipe 250.00 Rm
B 160 mm diameter Upvc pipe 210.00 Rm
C 200 mm diameter Upvc pipe 155.00 Rm
28 Providing and fixing square-mouth S.W. gully trap class SP-1 7.00 Each
complete with C.I.grating brick masonry chamber with water tight
C.I. cover with frame of 300x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design. 100x100 mm size P type With
common burnt clay F.P.S.non modular) bricks of class
designation 7.5
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
29 Constructing brick masonry manhole in cement mortar 1:5 RCC 20 Each
top slab 20 cm thick using M-20 mix by using mixer and vibrator,
TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix
inside plastering 12mm thk with cement mortar1:3 finished with
floating coat of neat cement and making 40 mm thick benching in
cement concrete 1:2:4 finished with a floating coat of neat
cement, orange coloured PVC steps including RCC coverwith
frame complete as per standard design complete Inside size
75x120 cm and 120 cm deep
30 Providing & fixing in position sensor battery operated urinal of 4 Each
approved make
SUB TOTAL
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
PART-III :- ELECTRICAL WORKS
1 Wiring for light point/ fan point/ exhaust fan point/ call bell point 145 Per
with 1.5 sq.mm FRLS PVC insulated copper conductor single Point
core cable in surface / recessed PVC conduit, with modular
switch, modular plate, suitable GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core
cable etc as required.
2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC 12 Per
insulated copperconductor single core cable in surface / recessed Point
medium class PVC conduit, 2 way piano type switch, phenolic
laminated sheet, suitable size MS box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core
cable etc as required.
3 Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FRLS PVC insulated copper conductor, single
core cable in surface/ recessed medium class Pvc Conduit as
required.
A 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 200.00 Rm
B 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 260.00 Rm
C 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 220.00 Rm
D 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 250.00 Rm
E 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 60.00 Rm
4 Supplying and fixing following modular switch/ socket on the
existing modular plate & switch boxincluding connections but
excluding modular plate etc. as required.
A 5/6 amps modular switch 200 Each
B 2 way 5/6 amps switch 12 Each
C 15/16 amp switch 15 Each
D 3 pin 5/6 amp socket outlet 25 Each
E 6 pin 15/16 amp socket outlet 15 Each
F Telephone socket outlet 3 Each
G Bell push 4 Each
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
5 Supplying and fixing two module stepped type electronic fan 22 Each
regulator on the existing modlar plate switch box including
connections but excluding modular plate etc.as required.

6 Supplying and fixing modular blanking plate on the existing 20 Each


modular plate & switch box excluding modular plate as required.
7 Supplying and fixing following size/ modules, GI box alongwith
modular base & cover plate for modular switches in recess etc as
required
A 1 or 2 Module (75mmX75mm) 4 Each
B 3 Module (100mmX75mm) 4 Each
C 4 Module (125mmX75mm) 6 Each
D 6 Module (200mmX75mm) 4 Each
E 8 Module (125mmX125mm) 4 Each
F 12 Module (200mmX150mm) 3 Each
8 Supplying and fixing following Modular base & cover plate on
existing modular metal boxes etc. as required.
A 1 or 2 Module 8 Each
B 3 Module 6 Each
C 4 Module 7 Each
D 6 Module 4 Each
E 8 Module 4 Each
F 12 Module 6 Each
9 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing 65 Each
junction box/ wooden block including connection etc as required.
10 Supplying and fixing brass batten/ angle holder including 35 Each
connection etc. as required.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
11 Providing and fixing following capacity TP&N disconnector fuse
switch unit inside the existing panel board with ISI marked HRC
fuses including drilling holes in cubicle panel, making connections.

A 32 A TP&N 4 Each
B 63 A TP&N 2 Each
C 100 A TP&N 1 Each
12 Providing and fixing following rating and breaking capacity MCCB
with theromagnetic release and terminal spreaders in existing
cubicle panel board including drilling holes in cubicle panel,
making connections, etc.
A 100 A 30 KA 4Pole 2 Each
B 200 A 25 KA 1 Each
13 Supplying and fixing following way, single pole and neutral, sheet
steel, MCB distribution board, 240 240 volts, on surface/ recess,
complete with tinned copper busbar, neutral bus bar,earthing
bar,din bar interconnections, powder painted includingearthing
etc.as required.(But without MMCB/ RCCB /Isolator)

A 6 way, Double door 2 Each


B 8 way, Double door 4 Each
C 12 way, Double door 2 Each
14 Supplying and fixing of following ways surface/ recess mounting, 3 Each
vertical type, 415 volts,TPN MCB distribution board of sheet
steel, dust protected, duly powder painted,inclusive of 200 200
amps tinned copper bus bar, common neutral link, earth bar, din
bar for mounting MCB's (but without MCB’s and incomer ) as
required . (Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
4 way (4 + 12), Double door
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
15 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10
kA, “C” curve, miniature circuit breaker suitable for inductive load
of following poles in the existing MCB DB complete with
connections, testing and commissioning etc.
A Single pole 6A to 32 A 25 Each
B Single pole and neutral -MCB SPN- 6A to 32 A 16 Each
C Triple pole and neutral 6 Each
16 Supplying and fixing following rating, double pole, 240 4 Each
volts,isolator in the existing MCB DB complete with connections,
testing and commissioning etc.
63 A Double Pole Isolator
17 Supplying and fixing 20 amps, 240 volts, SPN industrial type, 12 Each
socket outlet, with 2 pole and earth , metal enclosed plug top
alongwith 20 amps “C” curve, SP, MCB, in steel enclosure,on
surface or in recess, with chained metal cover for the socket out
let and complete with connections, testing and commissioning etc.

18 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including 6 Per Set
accessories, and providing masonry enclosure with cover plate
having locking arrangement and watering pipe etc.as required.
19 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick 2 Per Set
including accessories,and providing masonry enclosure with
cover plate having locking arrangement and watering pipe 2.7
metre long etc. with charcoal/ coke and salt as required.
20 Supplying and laying 6 SWG G.I. wire at 0.50 metre below 125.00 Rm
ground level for conductor earth electrode, including connection/
termination with GI thimble etc.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
21 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre 50.00 Rm
below ground as strip earth electrode, including connection/
terminating with G.I. nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm)
22 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. 40.00 Rm
pipe from earth electrode including connection with G.I. nut, bolt,
spring, washer excavation and re-filling etc.
23 Providing and fixing 4.00 mm dia copper wire on surface or in 100.00 Rm
recess for loop earthing as required.
24 Supply & errection of Ceiling fan 1400mm sweep 28.00 Each

25 Supply & errection of heavy duty exhuast fan 300 mm, 900 RPM 20.00 Each
double ball bearing complete in all respects.
26 Supply & errection of loover shutter size 300mm sweep complete 20.00 Each
in all respects
27 Supply and fixing 1x22 watt lED tube rod 4 feet size energy 38.00 Each
efficient batten fitting with all accessories internally pre wired
with and including connecting up with three core flexible copper
conductor cable of size 1.0 sqmm complete all as specified and
approved Make.
28 Supply and Errection of Split AC 1.5 Ton Invertor Technology 8.00 Each
complete with Voltage Stablizer of required KVA.
29 1x150 wat HP LED flood light with pressure die cast aluminium 5.00 Each
housing complete with lamp and all accessories and MS Pole of
100 mm dia and 5 mtr height with arm and junction box all
complete with painting etc.
SR. Name of Work Total Qty. Unit Rate Amount

No.
(in figures) (in words)
30 Supply, Installion,commissioning and testing of outdoor LT panel board 1 Each
made out of CRCA sheet 3mm thick dust and vermin proof factory
made CPRI approved with necessary angle iron 50x6mm support
frame duly powder coated grouted in PCC complete all as s[pecified
and directed with and including the following:-
INCOMING:-
(a) Aluminium bus bar of capacity 200 Amp for 3 phase with neutral-01
No.
(b) MCCB 415 V 63Amp rating, 4pole ,25 KA rupturing capacity
(Ics=100% Icu) with over load short circuit and earth fault protection-01
No.
(c ) Digital voltmeter 0-500 volt square flush mounted with inbuilt
selector switch-01 No.
(d) Digital ampere meter square flush mounted with inbuilt selector-01
No.
( e ) Indicator lamps RYB LED type-01 Set of three.
(f) CT coil 200/5A- 03 N0s.
OUT GOING:-
( a) MCB 32 A ,SPN,415 V (c Series), breaking capacity 10KA -06 No.

NOTES:-1. All MCB shall be fitted on 8mm thick bakelite sheets.


2. The platform shall be of 450 mm height above and 450mm below
ground level leaving minimum 100mm all around.Rate for PCC
foundation for panel deemed be included in the unit quoted rate.

3. MCCB shall be connected with solid copper strip from bus bar
31 Supply and laying XLPE insulated Aluminium conductor Armoured 4
core heavy duty 1100v grade specifications as per CSR
A 70 SQ mm Aluminium 4 core 50 Rm
B 95 SQ mm Aluminium 4 core 50 Rm
C 120 SQ mm Aluminium 4 core 50 Rm
SUB TOTAL
GRAND TOTAL