Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Isolated Footing Design (ACI 318-14) - Metric: Elevation

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

Print Calculation Sheet

Isolated Footing Design(ACI 318-14) - Metric


Footing No. Group ID Foundation Geometry
- - Length Width Thickness
1420 9 1.50m 1.50m 0.70m

Footing No. Footing Reinforcement Pedestal Reinforcement


- Bottom Reinforcement(Mz) Bottom Reinforcement(Mx) Top Reinforcement(Mz) Top Reinforcement(Mx) Main Steel Trans Steel
1420 11 - 16 mm 11 - 16 mm N/A N/A 16 - 19 mm 10 mm @ 300 mm

Isolated
0.5 m Footing 1420
0.3 m 1m

Elevation 0.7 m

X 0.75 m

Z
0.61 m
1.5 m

0.61 m
0.75 m

1.5 m

Plan

Input Values

Footing Geometry

Calculate Dimension with user


Design Type : specified minimums as starting
value
Minimum Footing Length - X(Fl) : 1000.00 mm
Minimum Footing Width - Z (Fw) : 1000.00 mm
Footing Thickness (Ft) : 700.00 mm
Eccentricity along X (Oxd) : 0.00 mm
Eccentricity along Z (Ozd) : 0.00 mm

Column Dimensions

09-Dec-23 13:53:46 PM 1/14


Column Shape : Rectangular
Column Length - X (Dcol) : 0.25 m
Column Width - Z (Bcol) : 0.25 m

Pedestal

Include Pedestal : Yes


Pedestal Shape : Rectangular
Pedestal Height (Ph) : 0.30 m
Pedestal Length - X (Pl) : 0.61 m
Pedestal Width - Z (Pw) : 0.61 m

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 24.00 kN/m3


Strength of Concrete : 20.00 N/mm2
Yield Strength of Steel : 350.00 N/mm2
Minimum Bar Size : 16 mm
Maximum Bar Size : 16 mm
Top Footing Minimum Bar Size : 16 mm
Top Footing Maximum Bar Size : 16 mm
Pedestal Minimum Bar Size : 19 mm
Pedestal Maximum Bar Size : 32 mm
Minimum Bar Spacing : 100.00 mm
Maximum Bar Spacing : 450.00 mm
Pedestal Clear Cover (P, CL) : 50.00 mm
Bottom Footing Clear Cover (F, CL) : 50.00 mm

Soil Properties

Unit Weight : 17.60kN/m3

Base Value of Soil Bearing Capacity : 120.00kPa

Multiplying factor for soil bearing capacity for ultimate


: 1.70
loads

Soil Bearing Capacity Type : Gross Bearing Capacity

Soil Surcharge : 0.00kN/m2

Height of Soil above Footing : 500.00mm

Type of Depth : Fixed Top

Bearing Capacity Input Method : Fixed Bearing Capacity

Minimum Percentage of Slab area in Contact for Service


: 0.00
Loads

Minimum Percentage of Slab area in Contact for Ultimate


: 0.00
Loads

Sliding and Overturning

Coefficient of Friction : 0.50


Factor of Safety Against Sliding : 1.50
Factor of Safety Against Overturning : 1.50

Global Settings

Top Reinforcement Option : Calculate only when foundation is subjected to uplift forces
Concrete Design Option : Net Pressure(Gross Pressure - Self Weight Pressure)
Top Reinforcement Factor : 1.00

09-Dec-23 13:53:46 PM 2/14


------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 1.00 m


Initial Width (Wo) = 1.00 m

Load Combinations

Load Combination/s- Service Stress Level


Load Load Case Soil Self
Combination Load Combination Title Multiplier Bearing Weight Code
Number (a) Factor (b) Factor (c)
a - Value specified in the Load Multiplier table
b - Value specified in the Pile/Soil Bearing Capacity Factors table
c - Value specified in the Apply Self Weight and Dead Weight Factor table
10 GENERATED AISC:360-2010 GENERAL 4 1.00 1.00 1.00 -

Load Combination/s- Strength Level


Load Load Case Soil Self
Combination Load Combination Title Multiplier Bearing Weight Code
Number (a) Factor (b) Factor (c)
a - Value specified in the Load Multiplier table
b - Value specified in the Pile/Soil Bearing Capacity Factors table
c - Value specified in the Apply Self Weight and Dead Weight Factor table
10 GENERATED AISC:360-2010 GENERAL 4 1.00 1.00 1.00 -

Applied Loads on Top of Pedestal


Before consideration of self weight and load multiplier table

Moments are about the center of Column / Pedestal (does not include moments caused by lateral loads)
For the loads shown in this table, the sign convention is the same as that for JOINT LOADS in STAAD.Pro when global Y is the vertical axis.

Applied Loads from Column - Service Stress Level


Fy
(kN)
Fx Fz Mx Mz
Load Case Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards
is positive
10 5.21 -9.26 1.49 4.30 -20.28

Applied Loads from Column - Strength Level


Fy
(kN)
Fx Fz Mx Mz
Load Case Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards
is positive
10 5.21 -9.26 1.49 4.30 -20.28

Reduction of force due to buoyancy = 0.00 kN

Effect due to adhesion = 0.00 kN

2
Area from initial length and width, Ao = Lo X W o = 1.00 m

2
Min. area required from bearing pressure, Amin = 0.55 m

Note: Amin is an initial estimation considering self-weight, axial load and moment against factored bearing capacity.

Final Footing Size

Length (L2) = 1.50 m Governing Load Case : # 10


1.50 m Governing Load Case : # 10

09-Dec-23 13:53:46 PM 3/14


Width (W2) =
Depth (D2) = 0.70 m
Depth is governed by Ultimate Load Case
(Service check is performed with footing thickness requirements from concrete check)

Area (A2) = 2.25 m2


Final Pedestal Height = 0.30 m
Final Soil Height = 0.50 m
Weight of the footing + pedestal (if any) = 40.52 kN
Soil Weight On Top Of Footing = 16.53 kN

Gross Pressures at 4 Corners

Pressure Pressure Area of


Pressure Pressure Gross
at top at bottom footing in
Load Case / at top left at bottom Bearing
right right uplift (Au)
Combination corner left corner Capacity
corner corner 2
(kN/m2) (kN/m2) (m ) (kN/m2)
(kN/m2) (kN/m2)

10 -26.1991 64.5351 85.1414 -5.5928 0.64 120.0000

10 -26.1991 64.5351 85.1414 -5.5928 0.64 120.0000

10 -26.1991 64.5351 85.1414 -5.5928 0.64 120.0000

10 -26.1991 64.5351 85.1414 -5.5928 0.64 120.0000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero and the pressure
will be redistributed to remaining corners.

Summary of Adjusted Gross Pressures at four Corners

Pressure at Pressure at Pressure at Pressure at


top left top right bottom right bottom left Gross Bearing
Load Case / corner corner corner corner Capacity
Combination (kN/m2) (kN/m2) (kN/m2) (kN/m2) (kN/m2)

10 0.0000 67.1235 95.9200 0.0000 120.0000

10 0.0000 67.1235 95.9200 0.0000 120.0000

10 0.0000 67.1235 95.9200 0.0000 120.0000

10 0.0000 67.1235 95.9200 0.0000 120.0000

Stability Check

09-Dec-23 13:53:46 PM 4/14


Sliding Force 0.3 m 1m

Frictional Force 0.7 m

Factor of safety against


- Factor of safety against sliding
overturning

Load
Along X- Along Z- Required About X- About Z- Required
Case Resultant
Direction Direction FOS Direction Direction FOS
No.

10 6.36 22.28 6.12 1.50 8.58 1.95 1.50

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 10


Governing Disturbing Force : 5.21 kN
Governing Restoring Force : 33.16 kN
Minimum Sliding Ratio for the Critical Load Case : 6.36
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : 5.80 kNm
Governing Resisting Moment : 49.73 kNm
Minimum Overturning Ratio for the Critical Load Case : 8.58

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : 1.49 kN
Governing Restoring Force : 33.16 kN
Minimum Sliding Ratio for the Critical Load Case : 22.28
Critical Load Case for Overturning about Z-Direction : 10
Governing Overturning Moment : -25.52 kNm
Governing Resisting Moment : 49.73 kNm
Minimum Overturning Ratio for the Critical Load Case : 1.95
Critical Load Case And The Governing Factor Of Safety For Sliding Along Resultant Direction
Critical Load Case for Sliding along Resultant Direction : 10
Governing Disturbing Force : 5.42 kN
Governing Restoring Force : 33.16 kN
Minimum Sliding Ratio for the Critical Load Case : 6.12

Ultimate Gross Pressures


The base pressures reported in this table and the area of footing in contact include the effect of buoyancy (if any).

Gross
Factored Area of
Pressure at
Load Case / Pressure at Pressure at Pressure at Bearing footing in
bottom
Load top left top right bottom left Capacity Contact
right
Combination corner corner corner For with soil
corner
ID (kN/m2) (kN/m2) (kN/m2) Ultimate (Au)
(kN/m2) 2
Load Case (m )
(kN/m2)

10 0.0000 67.1235 95.9200 0.0000 204.0000 1.61

09-Dec-23 13:53:46 PM 5/14


Minimum Required Contact Area for Ultimate Loads : 0.00 m2

Actual Area in Contact for all ultimate load cases exceeds the minimum required. Hence Safe

Gross Bearing Capacity for Ultimate Loads : 204.00 kN/m2

Maximum Corner Pressure from all ultimate load cases is less than the allowable. Hence Safe

Shear Calculation

Punching Shear Check

X 0.75 m

0.315 m
Z
0.75 m

Plan
Total Footing Depth, D = 0.70m
Calculated Effective Depth, d = D - Ccover - 1 * db = 0.63 m
For rectangular column, = Bcol / Dcol = 1.00

Effective depth, d, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 35.52kN, Load Case # 10

From ACI Cl. 22.6.5.2, bo for column= = 4.97 m

Table 22.6.5.2, (b), Vc1 = = 7194.80 kN

Table 22.6.5.2, (c), Vc2 = = 8311.76 kN

Table 22.6.5.2, (a), Vc3 = = 4655.46 kN

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 3491.59 kN


0.75 X Vc > Vu hence, OK

One-Way Shear in XY Plane

(Shear Plane Parallel to Global X Axis)

09-Dec-23 13:53:46 PM 6/14


X 0.75 m

0.75 m
Plan
From ACI Cl. 22.5.5.1, Vc = = 714.06 kN

Distance of critical section from top left corner


along Z, DZ = = 0.00 m

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the X axis.

From above calculations, 0.75 X Vc = 535.54 kN

Critical load case for Vux is # 10 = 0.00 kN

0.75 X Vc > Vux hence, OK

One-Way Shear in YZ Plane

(Shear Plane Parallel to Global Z Axis)

X 0.75 m

Z
0.75 m

Plan
From ACI Cl. 22.5.5.1, Vc = = 714.06 kN

Distance of critical section from top left corner along


X, DX = = 0.00 m

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the Z axis.

From above calculations, 0.75 X Vc = 535.54 kN

Critical load case for Vuz is # 10 = 0.00 kN

0.75 X Vc > Vuz hence, OK

Flexure About Z-Axis

09-Dec-23 13:53:46 PM 7/14


Design For Bottom Reinforcement Parallel to X Axis

11 - 16 mm

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required.

Critical Load Case # 10

The strength values of steel and concrete used in the formulae are in Mpa

Bars parallel to X Direction are placed at bottom


Effective Depth d = 0.63 m
Factor from ACI Cl. 22.2.2.4.3 =
= 0.85

From ACI318-2011 Appendix B 8.4.2, = = 0.02607

Maximum Reinforcement Ratio corresponding to εt


= 0.005 = = = 0.01548

From ACI Cl. 7.6.1.1, = = 0.00200

From Ref.1, Eq. 3.8.4a, constant m = = 20.59

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is performed at the face


of the column at a distance from top left corner of = 1.05 m
footing, Dx =

Ultimate moment = = 6.85 kNm

Nominal moment capacity required, Mn = = 7.61 kNm

(Based on effective depth) Required = = 0.00004

(Based on gross depth) x d / Depth = 0.00003


Since ρ < ρmin, select ρ= ρmin ρmin Governs
Area of Steel Required, As = = 2100.00 mm2
Note - "Area of Steel required" reported here is the larger value between the calculated area of steel and minimum steel required as per code stipulations
Selected bar Size = 16 mm
Minimum spacing allowed (Smin) = 100.00mm
Selected spacing (S) = 138.41mm
Smin<= S <= Smax and selected bar size < selected maximum bar size
The reinforcement is accepted.
According to ACI 318 Clause No- 24.3.2
Max spacing for Cracking Consideration = 330.86mm

Safe for Cracking Aspect.

09-Dec-23 13:53:46 PM 8/14


Based on spacing reinforcement increment; provided reinforcement is

16 mm @ 135mm o.c.

Required development length for bars = = 0.59 m

Available development length for bars,DL = = 0.40 m

Try bar size 16 mm Area of one bar = 199.00 mm2

Number of bars required, Nbar = = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2189.00 mm2
d= D - Ccover - 0.5 X (dia. of = 0.63 m
one bar)

Reinforcement ratio, = = 0.00233

From ACI Cl. 25.2.1, minimum req'd clear distance between bars
Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 100.00mm
Provided Steel Area / Required Steel Area = 1.04

Flexure About X-Axis

Design For Bottom Reinforcement Parallel to Z Axis

11 - 16 mm

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required.

Critical Load Case # 10

The strength values of steel and concrete used in the formulae are in Mpa

Bars parallel to X Direction are placed at bottom


Effective Depth d = 0.63 m
Factor from ACI Cl. 22.2.2.4.3 =
= 0.85

From ACI318-2011 Appendix B 8.4.2, = = 0.02607

Maximum Reinforcement Ratio corresponding to εt


= 0.005 = = = 0.01548

From ACI Cl. 7.6.1.1, = = 0.00200

From Ref.1, Eq. 3.8.4a, constant m = = 20.59

09-Dec-23 13:53:46 PM 9/14


Calculate reinforcement ratio for critical load case

Design for flexure about X axis is performed


at the face of the column at a distance from = 1.05 m
top left corner of footing, Dz =

Ultimate moment = = 2.06 kNm

Nominal moment capacity required, Mn = = 2.29 kNm

(Based on effective depth) Required = = 0.00001

(Based on gross depth) x d / Depth = 0.00001


Since ρ < ρmin, select ρ= ρmin ρmin Governs
Area of Steel Required, As = = 2100.00 mm2
Note - "Area of Steel required" reported here is the larger value between the calculated area of steel and minimum steel required as per code stipulations
Selected Bar Size = 16 mm
Minimum spacing allowed (Smin) = 100.00mm
Selected spacing (S) = 138.41mm
Smin<= S <= Smax and selected bar size < selected maximum bar size
The reinforcement is accepted.

Max spacing for Cracking Consideration = 330.86mm

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

16 mm @ 135mm o.c.

Required development length for bars


= 0.59 m
=

Available development length for bars,


= 0.40 m
DL =
Try bar size 16 mm Area of one bar = 199.00 mm2

Number of bars required, Nbar= = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2189.00 mm2
d= D - Ccover - 1.5 X (dia. of 0.63 m
=
one bar)

Reinforcement ratio, = = 0.00233

From ACI Cl. 25.2.1, minimum req'd clear distance between bars
Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 100.00mm
Provided Steel Area / Required Steel Area = 1.04

Pedestal Design

Pedestal at Support No. Axial Capacity Ratio, Critical Load Case, Location Flexural Capacity Ratio % of Main Steel Main Reinforcement Links
1420 0.00, 10, Bottom 0.07 1.23 16-#19 10 @ 300mm

Pedestal Size

Pedestal Shape = Rectangular


Dimension Along Global X = 609.60 mm
Dimension Along Global Z = 609.60 mm

Longitudinal Reinforcement Details

Area of Longitudinal Bars = 4584.32 sq.mm


Number of Bars and Bar Dia = 16-#19

09-Dec-23 13:53:46 PM 10/14


Longitudinal Steel Percentage = 1.23
Bar arrangement sequence on each = 5 # 19
side along Global X
Bar arrangement sequence on each = 5 # 19
side along Global Z
Flexure - Governing Load Case Details
Governing Load Case Number = 10
Critical Location = Bottom
Axial load = 18.23 kN
Moment about X axis = 5.80 kNm
Moment about Z axis = -25.52 kNm
Resultant moment = 26.17 kNm
Moment Capacity = 371.95 kNm
Angle of inclination of Neutral Axis
= 12.80 degrees
with respect to local Z
P M Strength Reduction Factor
Serial No.
(kN) (kNm) (Φ)
1 -1444.06 0.00 0.90
2 -1443.18 0.32 0.90
3 -1412.18 11.00 0.90
4 -1186.05 78.79 0.90
5 -794.45 184.73 0.90
6 -305.12 300.74 0.90
7 146.96 400.53 0.90
8 594.11 481.19 0.90
9 984.29 532.46 0.88
10 1149.18 534.24 0.83
11 1294.97 530.14 0.80
12 1421.39 524.49 0.76
13 1532.59 517.49 0.73
14 1636.57 509.06 0.71
15 1741.64 496.87 0.68
16 1842.44 482.04 0.66
17 1965.29 470.15 0.65
18 2127.80 464.50 0.65
19 2290.64 456.07 0.65
20 2466.76 446.13 0.65
21 2621.47 434.99 0.65
22 2772.48 422.73 0.65
23 2914.04 409.71 0.65
24 3059.11 395.11 0.65
25 3199.31 379.51 0.65
26 3336.05 362.84 0.65
27 3470.72 344.96 0.65
28 3734.60 305.44 0.65
29 4009.44 257.37 0.65
30 4265.65 205.72 0.65
31 4497.36 153.01 0.65
32 4673.08 108.28 0.65
33 4804.90 71.69 0.65
34 4882.31 49.63 0.65
35 4913.18 42.51 0.65
36 4956.46 33.92 0.65
37 4992.85 26.60 0.65
38 5019.30 20.55 0.65
39 5042.01 15.29 0.65
40 5062.05 10.65 0.65
41 5079.15 6.65 0.65
42 5090.38 3.81 0.65
43 5097.71 1.84 0.65
44 5103.36 0.23 0.65
45 5103.98 0.00 0.65

09-Dec-23 13:53:46 PM 11/14


ϕPn,max = 4083.1848511999997

Axial Load [kN]


1000

-1000

-2000
0 90 180 270 360 450 534.236282
ϕM (12.8 deg) (kNm)
Moment [kNm]

Shear - Governing Load Case Details


Critical Load Case for Shear Along X = 10
Critical Load Case for Shear Along Z = 10
Shear force along X = 5.21 kN
Shear force along Z = 1.49 kN

Transverse Stirrups Details

Rebar Links = 10 @ 300 mm


No. of Legs in X direction = 5
No. of Legs in Z direction = 5

Material Take Off


Footing Reinforcement

Direction Size Number Total Length (m) Weight (kg)

Along Z on Bottom
16 mm 11 15.40 23.90
Face

Along X on Bottom
16 mm 11 15.40 23.90
Face

Along Z on Top
N/A N/A N/A N/A
Face

Along X on Top
N/A N/A N/A N/A
Face

Pedestal Reinforcement

Total Bar Length


Type Size Number Weight (kg)
(m)

Main Steel
19 mm 16 17.10 38.22
(Vertical)

Transverse Steel
10 mm 3 6.57 3.68
(Ties)

Internal Steel
10 mm 18 11.92 6.67
(Ties)

Total Reinforcement Weight : 96.38 kg

Concrete

3
- Length (m) Width (m) Thickness (m) Volume (m )

Footing 1.50 1.50 0.70 1.58

Pedestal 0.61 0.61 0.30 0.11

Total Concrete Volume : 1.69 m3

09-Dec-23 13:53:46 PM 12/14


Formwork

Footing : 4.20 m2

Pedestal : 0.74 m2

Total : 4.94 m2

Soil Excavation

Pit Depth : 1.20 m


Pit Slope (a : b) : 1 : 1 (Assumed)
Side Distance, s : 0 (Assumed)
Excavation Volume : 9.32 m3

Backfill Volume : 7.64 m3

09-Dec-23 13:53:46 PM 13/14


14/14

X 0.75 m
0.5 m
Z 0.61 m
0.3 m 1m
1.5 m

0.61 m
0.75 m

1.5 m

09-Dec-23 13:53:46 PM
0.7 m
Plan
0.75 m
Elevation
BOTTOM 11 - 16 mm
Dimensions (m) Reinforcement

TOP N/A
L B D AstX(T) AstZ(T) AstX(B) AstZ(B)
Foundation
0.75 m

1.5 m 1.5 m 0.7 m N/A N/A 11 - 16 mm 11 - 16 mm


l b h Main Reinforcement Trans Reinforcement
TOP N/A Pedestal
0.61 m 0.61 m 0.3 m 19 mm - 16 10 mm @ 300 mm
BOTTOM 11 - 16 mm
Plan

You might also like