Isolated Footing Design (ACI 318-14) - Metric: Elevation
Isolated Footing Design (ACI 318-14) - Metric: Elevation
Isolated Footing Design (ACI 318-14) - Metric: Elevation
Isolated
0.5 m Footing 1420
0.3 m 1m
Elevation 0.7 m
X 0.75 m
Z
0.61 m
1.5 m
0.61 m
0.75 m
1.5 m
Plan
Input Values
Footing Geometry
Column Dimensions
Pedestal
Design Parameters
Soil Properties
Global Settings
Top Reinforcement Option : Calculate only when foundation is subjected to uplift forces
Concrete Design Option : Net Pressure(Gross Pressure - Self Weight Pressure)
Top Reinforcement Factor : 1.00
Design Calculations
Footing Size
Load Combinations
Moments are about the center of Column / Pedestal (does not include moments caused by lateral loads)
For the loads shown in this table, the sign convention is the same as that for JOINT LOADS in STAAD.Pro when global Y is the vertical axis.
2
Area from initial length and width, Ao = Lo X W o = 1.00 m
2
Min. area required from bearing pressure, Amin = 0.55 m
Note: Amin is an initial estimation considering self-weight, axial load and moment against factored bearing capacity.
If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero and the pressure
will be redistributed to remaining corners.
Stability Check
Load
Along X- Along Z- Required About X- About Z- Required
Case Resultant
Direction Direction FOS Direction Direction FOS
No.
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction
Gross
Factored Area of
Pressure at
Load Case / Pressure at Pressure at Pressure at Bearing footing in
bottom
Load top left top right bottom left Capacity Contact
right
Combination corner corner corner For with soil
corner
ID (kN/m2) (kN/m2) (kN/m2) Ultimate (Au)
(kN/m2) 2
Load Case (m )
(kN/m2)
Actual Area in Contact for all ultimate load cases exceeds the minimum required. Hence Safe
Maximum Corner Pressure from all ultimate load cases is less than the allowable. Hence Safe
Shear Calculation
X 0.75 m
0.315 m
Z
0.75 m
Plan
Total Footing Depth, D = 0.70m
Calculated Effective Depth, d = D - Ccover - 1 * db = 0.63 m
For rectangular column, = Bcol / Dcol = 1.00
0.75 m
Plan
From ACI Cl. 22.5.5.1, Vc = = 714.06 kN
Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the X axis.
X 0.75 m
Z
0.75 m
Plan
From ACI Cl. 22.5.5.1, Vc = = 714.06 kN
Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance d from the face of the column caused by bending about the Z axis.
11 - 16 mm
Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required.
The strength values of steel and concrete used in the formulae are in Mpa
16 mm @ 135mm o.c.
Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax
Total reinforcement area, As_total = Nbar X (Area of one bar) = 2189.00 mm2
d= D - Ccover - 0.5 X (dia. of = 0.63 m
one bar)
From ACI Cl. 25.2.1, minimum req'd clear distance between bars
Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 100.00mm
Provided Steel Area / Required Steel Area = 1.04
11 - 16 mm
Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required.
The strength values of steel and concrete used in the formulae are in Mpa
16 mm @ 135mm o.c.
Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax
Total reinforcement area, As_total = Nbar X (Area of one bar) = 2189.00 mm2
d= D - Ccover - 1.5 X (dia. of 0.63 m
=
one bar)
From ACI Cl. 25.2.1, minimum req'd clear distance between bars
Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 100.00mm
Provided Steel Area / Required Steel Area = 1.04
Pedestal Design
Pedestal at Support No. Axial Capacity Ratio, Critical Load Case, Location Flexural Capacity Ratio % of Main Steel Main Reinforcement Links
1420 0.00, 10, Bottom 0.07 1.23 16-#19 10 @ 300mm
Pedestal Size
-1000
-2000
0 90 180 270 360 450 534.236282
ϕM (12.8 deg) (kNm)
Moment [kNm]
Along Z on Bottom
16 mm 11 15.40 23.90
Face
Along X on Bottom
16 mm 11 15.40 23.90
Face
Along Z on Top
N/A N/A N/A N/A
Face
Along X on Top
N/A N/A N/A N/A
Face
Pedestal Reinforcement
Main Steel
19 mm 16 17.10 38.22
(Vertical)
Transverse Steel
10 mm 3 6.57 3.68
(Ties)
Internal Steel
10 mm 18 11.92 6.67
(Ties)
Concrete
3
- Length (m) Width (m) Thickness (m) Volume (m )
Footing : 4.20 m2
Pedestal : 0.74 m2
Total : 4.94 m2
Soil Excavation
0.61 m
0.75 m
1.5 m
09-Dec-23 13:53:46 PM
0.7 m
Plan
0.75 m
Elevation
BOTTOM 11 - 16 mm
Dimensions (m) Reinforcement
TOP N/A
L B D AstX(T) AstZ(T) AstX(B) AstZ(B)
Foundation
0.75 m