■ Model: FC150X-C(silent)

Powered by CUMMINS

■ Generator Specification ■ Alternator Specification

— 50Hz Manufacture
Powers PRP(1) ESP(2) Prime Brand
Voltage (V) KW KVA KW KVA Amps Model TAL-A44-H (60HZ)
380/220 108 135 120 150 205.1 Series LSA TAL STD(3) S STD(3) STD(3)

400/230 108 135 120 150 194.9 Option ○ ● ○ ○ ○ ○

415/240 108 135 120 150 187.8

— 60Hz Alternator Data


Powers PRP(1) ESP(2) Prime Frequency / Speed 50Hz / 1500rpm 60Hz / 1800rpm
Voltage (V) KW KVA KW KVA Amps Coupling / No. of Bearings Direct / Single Bearing
380/220 120 150 132 165 227.9 Phase / Poles 3-Phase / 4-Pole
400/254 120 150 132 165 216.5 Power Factor Cos Φ = 0.8
220/127 120 150 132 165 393.7 AVR Regulation Yes
230/132 120 150 132 165 376.5 Voltage Regulation ± 0.5 %
Insulation Class H
Drip Proof IP23
Engine Data Excitation Shunt
Engine brand Cummins Altitude ≤1000
Engine model 6BTAA5.9-G2 Overspeed 2250
Speed control type Electronic
Starter motor voltage 24V Ratings:
All three phase generator sets are rated at 0.8 power factor. All single-phase
Engine speed (RPM) 1500 1800 generator sets are rated at 0.8 or 1.0 power factor.
standby power 34 38
Fuel 100% prime power 30 34 (1)PRP (Prime Power):
Consumption 75% prime power 23 25
Available continuously at variable load in lieu of commercially purchased power
(L/H) for an unlimited number of hours per year accordance with ISO8528-1, and an
overload of 10% permitted for one hour in every twelve hours of operation in
50% prime power
16 18 accordance with ISO 3046-1.

(2)ESP (Standby Power):


Emergency Standby Power in variable load applications in accordance with ISO8528-1
in the event of a utility power failure.

(3)STD:Standard Alternator.
TIDE Power reserves the right to change the design or specifications without notice and without any obligation or liability.

Fuel system
Injection system BYC PB DIRECT INJECTION
Governor type Electronic
Maximum restriction at lift pump 13.6kPa
Maximum fuel inlet temperature 40℃
Top drain flow
Standard reference Conditions (constant for all loads) 30 liters/h
Note: Standard reference condition 25°C[77°F] air inlet temp, 1000m(328ft) A.S.L
30%
relative humidity. Fuel consumption data with diesel fuel with specific gravity of
0.85 and
conforming to BS 2869: 1998, Class A2

Air intake system


Dimension and Weight@50HZ/60HZ Maximum intake air restriction
Dimension Open Silent with heavy duty air cleaner:
Length (L) 2330mm 3277mm -Dirty element 6kpa
Width (W) 936mm 1150mm -Clean element 3.7kpa
Height (H) 1442mm 1530mm
Net Weight 1200KG 1633KG
Fuel Tank (L) 277 352 Lubrication system
Noise(dB) at 7m no load N/A 67 Engine oil pressure for engine
Super Slient Recommended protection devices:
— Idle speed(Minimum ) 207kPa
— Governed speed(Maximum ) 345kPa
■ Engine Specification: 6BTAA5.9-G2 Maximum oil temperature 121 ℃
Minimum required lube system
Basic technical data capacity-sump plus filters 16.4L
No. of cylinders 6
Cylinder arrangement In-line
Cycle 4 stroke Electrical system
Induction system Turbocharged & After cooled Cranking motor (Heavy duty,

Compression ratio 17.3:1 positive engagement 24V


Bore 102mm Battery charging system,
Stroke 120mm negative ground 40 ampere
Displacement 5.9L Maximum allowable resistance
Engine idle speed 750-850 RPM of cranking circuit 0.00075/0.002 ohm
Approximate engine weight 411kg

General installation@PRP 50Hz 60Hz


Cooling system Gross engine power output 120kw 132kw
Coolant capacity-engine 10L Piston speed 6.0 m/s 7.2 m/s
Maximum coolant friction Friction horsepower 12.7 kW 16.4 kW
head external to engine: Engine water flow to engine 2.0 l/sec 2.4 l/sec
-1800 rpm 35kPA Intake air flow 114 l/sec 135 l/sec
-1500 rpm 28kPA Exhaust gas flow 295 l/sec 369 l/sec
Maximum static head of coolant Exhaust gas temperature 500 ℃ 540 ℃
above engine crank centerline 14m Radiated heat to ambient 16kW 18kW
Standard Thermostat Heat rejection to coolant 59kW 63 kW
(Modulating) Range 82 - 95℃ Heat rejection to fuel TBD TBD
Minimum Pressure Cap 69 kPa
Maximum Top Tank Temperature
for Standby / Prime Power 104 / 100℃
■ Standard configuration

Engine Alternator Canopy Electrical cabinet


Radiator AVR Low carbon steel plate Mains floating charge
Standard starting motor(12V or 24V) Single bearing Surface powder coating Breaker(rated current≤1250A)
Oil sensor IP23 Flame retardant and sound Maintenance free battery
Water temperature sensor attenuated foam Control panel IP42
Standard engine charger Top lifting
Standard oil drainage pump Stainless steel screws for
Standard air filter, oil filter, fuel filter canopy external
Water/fuel separator
Oil drainage pump
Base Standard voltage Exhaust system Others
Engine/Alternator operation
Rubber anti-vibration mount 380/220V Open type- Industrial manual
silencer + accessories
400/230V Generator set operational manual
Generator set electrical wiring
415/240V Canopy type- Residential diagram
silencer
440/254V Generator set testing report
220/133V
208/127V
( Single phase 230V、220V)

■ Optional configuration

Engine Alternator Base


Air inlet heater Winding temperature sensor Extra capacity base fuel tank
Oil heater PMG Bunded base fuel tank
Jacket water heater Space heater Diesel fuel level sensor
Heavy duty air filter Anti corrosive winding Automatic fuel refilling system
Oil automatic refilling system IP44 Three ways valve
Enlarge radiator (suitable for high Spring vibration absorber
temperature) Air inlet filter
Anti corrosive radiator Marine paint for skid base
Heat exchanger instead of radiator
Remote radiator

Electrical system Exhaust system Canopy


Synchronizing controller Open type set with Residential silencer Surface paint or marine paint
4 poles switch Two poles silencer Stainless steel, Galvanized Canopy
Battery switch Super silent design canopy
Nickel-cadmium battery/extra capacity
battery Additional top lift
IP44 protection Control panel Stainless steel locks and hinges
Motorized switch Anti sand and dust filter for air
Switch with shunt line diagram Electrical louvre
IP44 control cabinet
■ Tide Power Easycon Function Summary

EC 2.0 / EC 3.0 / EC 4.0 / EC 5.0 /


Controller Model / ComAp
Nano Plus AMF20 AMF25 IG-NT

Controller Photos

Standard Supply × × ● ○
Viewable Parameters
Phase Voltage × 3 3 3
Current Instrumentation ● ● ●
Frequency ● ● ● ●
Active Power × ● ● ●
Reactive Power × ● ● ●
Apparent Power × ● ● ●
Power Factor × ● ● ●
Electric Energy Metering × ● ● ●
Generator Protection
Abnormal Voltage ● ● ● ●
Over-current Warning × ● ● ●
Over current Protection ● ● ● ●
Over Frequency Protection ● ● ● ●
Short Circuit Protection MCCB / ● MCCB / ● MCCB / ● MCCB / ●
Engine Figure
Oil Pressure ● ● ● ●
Water Temperature ● ● ● ●
Fuel Meter / Fuel Sensor ●/○ ●/○ ●/○ ●/○
Speed ● ● ● ●
Battery Voltage ● ● ● ●
Runing hours ● ● ● ●
Engine Protection
Low Oil Pressure Warning × ● ● ●
Low Oil Pressure Protection ● ● ● ●
High Temperature Warning × ● ● ●
High Temperature Protection ● ● ● ●
Overspeed Warning × ● ● ●
Overspeed Protection × ● ● ●
Alternator Charger ● ● ● ●
Functions
Remote Start ● ● ● ●
AMF (Auto Main Failure) ● ● ● ●
Service Indicate × × ● ●
Fault History ● ● ● ●
Gen-Gen Synchronising × × × ●
Gen-Mains Synchronising × × × ●
Remark: ● Standard Supply ○ Available as Optional × Not Available
■ Automatic Transfer Switch A.T.S - 4 Poles

Tide Power offers not only a changeover switch but also an integrated mains
detection and switch system for your 24 Hour Power Protection. The system
enables automatic start-up and operation of the generating set in the event of a
mains power failure, overvoltage or loss of a mains automatic re-transfer once it
come back.

System Advantages
▪ Automatically transfer and re-transfer load from main power to gen-power without
operator intervention.operation(Both automatic and manual).
▪ ATS Controller (AMF function), seamless integration with AMF25
▪ Available from 32 – 4000A, better protection for 4 pole switch.
▪ Available in standard, bypass isolation and service-entrance configurations.
▪ Configurable in open, closed and programmed transition operating modes.
▪ Designed to interface seamlessly with TIDE POWER generators and switchgear.
▪ Drip proof IP42 enclosure.
▪ Easy installation: wall-mounted & floor standing
▪ Comes fully loaded with the technology to do the job.

ATS cabinet size(mm) 500*400*200(1) 650*500*300(1) 1000*600*600 1600*1000*800


Rated current(A) 40~100 40-250 400-630 2000-3200
(1)The actual dimension of the ATS will depend on the brand used

Warranty

Tide Power distributor, dealer, or authorized representative


performs startup within 6 months of the date of shipment from Warranty Coverage
the factory, warranty coverage will begin on the startup date Generators for commercial use :
(Register the startup date to Tide within 6 month is essential 18 months or 1000 operating hours (for engine
and can be enforced). This warranty does not apply to malfunctions label with Prime power) 18 months or 200 hours
caused by damages, unreasonable use, misuse, repair or for labels with standby rated gensets.
service by unauthorized persons, or normal wear and tear.

You might also like