Model: VG-R165

 Generator Specification
Service PRP ESP Performance Data
Power(kVA) 150kva 165kva Model VG-R165
Power(kW) 120kw 132kw Engine Brand Ricardo
Rated speed ( r.p.m) 1800 Engine model R6105IZLD/132kw
Rated Outlet 220/127V 60Hz Alternator VG-274ES/120kw
Rated Power factor 0.8 @lagging Control system AMF digital panel 6120U
Rated Current 393 Amps Battery 2pcs 12V/80Ah
Breaker CHINT MCCB 3P 300A
Fuel consum. @100% load 35.2 L/h or 224g/kw.h

EMEAN Power gensets are compliant with ISO 9001 and CE standard, Dimension
which include the following directives: Type Soundproof
EN ISO 12100:2010, EN ISO 8528-13:2016, Length (L) 2900mm
EN 60204-1:2006+A1:2009+AC:2010, Width (W) 1080mm
EN 55012:2007+A1:2009 Height (H) 1500mm
Net Weight 1800kg
(1) PRP (Prime Power): Fuel Tank (L) 230L
According to ISO8528-1, prime power is the maximum power available
during a variable power sequence, which may be run for an unlimited
Standard Features:
number of hours per year, between stated maintenance intervals. The
 Brand new water cooled diesel engine
permissible average power output during at 24 hours period shall not exceed
 Brushless alternators (Class H, with AVR)
80% of the prime power. 10% overload available for governing purposes only.
 Working condition: -40 ℃ ~ +45 ℃ (fix with electric
heater for cold start)
(2) ESP (Standby Power):  Base frame fuel tank for continue 8-10hrs running
According to ISO 8528-1, It is defined as the maximum power available,
 Digital control panel with auto full protection
under the agreed operating conditions, for which the generating set is
 MCCB air circuit breaker with safety protection
capable of delivering for up to 500 hours of operation per year (of which no
 Residential silencer for silent type generator sets
more than 300 hours for continuous use) with the maintenance intervals and
 Humanized design, simple operation, easy
procedures being carried out as prescribed by the manufacturers. No
maintenance
overload capability is available
 All sets undergo a comprehensive testing pre delivery
 Peace of mind of one year warranty
 Engine/Motor Specification
Performance Data

Make Ricardo

Model R6105IZLD

In line Pump

Engine Type water cooling,

4 stroke, 6 Cylinder

Max Output power 132kw@1800RPM

Max RPM, off load ≤1875RPM

Low idling speed ≤600RPM

Bore× stroke(mm) 105*135

Compression Ratio 16:1

Displacement 7.1 L

Fire order 1-5-3-6-2-4

Oil capacity 16 L

Coolant capacity 14.2 L

Turbocharged and inter


Air Intake System
cooled

Fuel consumption 35.2 L/h(100%)

Oil consumption ≤1.63 g/kw.h

mean effective pressure 1237 kPa

Starter 24V DC

Fuel pump Mechanical

Cooling system 50℃ ambient radiator

Exhaust gas temperature ≤540℃


 Alternator Specification
Performance Data
Brand EMEAN
Model VG-274ES
Technology Genuine Brushless
Rated power 120KW @1800RPM

Winding 100% copper wire

Power factor(cosΦ ) 0.8

Efficiency 93.7%

Insulation system Class H

Protection IP23
Stator length 230mm
Rotor Single bearing
Winding Connections
Star/Y, 4 wires
(standard)
WINDING PITCH TWO THIRDS

WINDING LEADS 12

Excitation system Self-excited

Coating Vacuum impregnation

Voltage regulator A.V.R SX460

MAXIMUM OVERSPEED 2250 Rev/Min

ALTITUDE ≤1000m

Voltage Stabilized
≤±0.5%
regulation
Voltage Instantaneous
≤±20%
regulation
Voltage Recovery time ≤1S

Voltage Fluctuation ratio ≤1%


Voltage Wave aberration
≤5%
ratio
Frequency Stabilized
≤1%(adjustable)
regulation
Frequency Instantaneous
-10%~12%
regulation
Frequency Fluctuation
≤1%
ratio
 Control Panel  Terminal and Electric System

CONTROL MODULE FEATURES


This module is used to monitor a mains supply and automatically
start a standby generating set
Event logging and shutdown alarms
STOP/RESET-MANUAL-AUTO-TEST-START CHINT MCCB breaker 3P
METERING VIA LCD DISPLAY
Generator volts (L-L/L-N); mains volts (L-L/L-N)
Generator amps (L1, L2, L3); generator (kVA and kW)
Generator frequency; generator (cos)
Engine hours run; plant battery (volts)
Engine oil pressure (psi and bar) Engine speed (rpm)
GSM SMS signal Sealed 12/24V Dry battery 80A with Charger
Engine temperature (˚C)
AUTOMATIC SHUTDOWN AND FAULT CONDITIONS
Under/over speed; fail to start
High engine temperature; fail to stop
Low oil pressure; charge fail
Under/over generator volts; over current
Under/over generator frequency; emergency stop
Under/over mains frequency
Under/over mains voltage
Low/high battery volts 300A ATS for auto start when utility power off
 Canopy and Steel base General Information
Ventilation parts are designed with modular principles
1.Delivery time:
Soundproof and lined with sound reducing foam
All metal canopy parts are painted by powder paint
Within 30 days for silent type after receiving deposit.
Panel window
Lockable doors on front and back
2.Payment
Easy maintenance and operation
Easy lifting and moving
Bank Transfer, 30% deposit before production, 70%
Exterior emergency stop push button
Steel chassis and anti-vibration pads balance before the shipment.
Base frame design incorporates an integral fuel tank
The generator can be lifted or pushed/pulled by the base 3.Warranty
frame carefully
Includes diesel level sensor information to the controller We shall provide a warranty of 12 months or 1200hours
from B/L date (whichever comes first), covering all
manufacturing defects. We replace damaged parts
caused by manufacturing faults or defected
parts/materials, but exclude the damageable parts due to
customer's incorrect man-made operation. After
expiration, we still provides technical and spare parts
support with cost for maintenance.