Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

651542

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Metrodyne Microsystem Corp

MPS-3110 series
Pressure Sensor

 Features  Applications
 Competitive price SMD package  Digital blood pressure meter
 Wide operating temperature range:- 40 to +85oC  Digital pressure gauges
 Solid-state reliability  Environmental monitoring
 Easy to Use  Consumer & sports
 Easily Embedded in OEM Equipment  Medical instrumentation & monitoring
 Gauge pressure type(1、5.8、15、30、100 PSI)  Disposable blood pressure sensor

Pressure type Gauge


MPS-311X_GC series MPS-311X_GRC series

Model

 Outline dimensions

Rev. 1.9 1
Metrodyne Microsystem Corp
 Specifications

Parameter Min Typ Max Units Notes


General
Pressure Range 1、5.8、15、30、100 PSIG 40 KPaG
Maximum Overpressure 2X Rated pressure
o
Operating Temperature Range -40 85 C -40 oF ~+185oF
o
Storage Temperature Range -40 125 C -40 oF ~+257 oF
Operating humidity 15 85 ﹪RH No condensation
Media Compatibility Clean, dry air & noncorrosive gases
Electrical performance(1)
Excitation voltage 2 5 15 Vdc
Excitation current
3.3kOhm (MPS-3113) 0.6 1.5 4.5 mA (5)
5kOhm (MPS-3117、MPS-3118) 0.4 1 3
Bridge resistance
3.3kOhm (MPS-3113) 2.7 3.3 3.9 kΩ
5kOhm (MPS-3117、MPS-3118) 4 5 6
Offset Voltage -25 25 mV
Full Scale Span Voltage
1 PSI (MPS-3117) 20 30 40
5.8 PSI (MPS-3117) 50 75 100
5.8 PSI (MPS-3113、MPS-3118) 20 45 70
mV
15 PSI (MPS-3117) 130 170 210
15 PSI (MPS-3113、MPS-3118) 70 100 130
30 PSI (MPS-3118) 80 110 140
100 PSI (MPS-3118) 70 120 170
Linearity
1 PSI -0.7 0.15 0.7 % Span (2)
5.8, 15, 30, 100 PSI -0.3 0.05 0.3
Temperature Coefficient of Zero Offset
1 PSI -0.22 0.22 % Span/oC (3)
5.8, 15, 30, 100 PSI -0.08 0.08
Const. Voltage
-0.16 -0.21(4) -0.26
excitation (3)
Temperature Coefficient of Span %Span/ oC
Const. Current
-0.05 0.025(5) 0.05
excitation (3)
Temperature Coefficient of Resistance 0.17 0.2 0.23 %/ oC (3)
Notes:
1. Unless otherwise specified, measurements were taken with a supply voltage of 5 Vdc at a temperature of 25±3℃ and
humidity ranging from 25﹪~85﹪.
2. Best fit straight line.
3. Between 0 oC and 50 oC. Temperature coefficients are typical values.
4. Measured only with constant voltage excitation(5V).
5. Measured only with constant current excitation(1mA for 5kOhm sensor;1.5mA for 3.3kOhm sensor).
Metrodyne Microsystem Corp. reserves the right to make changes to the product specification in this publication.

Rev. 1.9 2
Metrodyne Microsystem Corp
 Terminal connection diagram

1 6
- Output - Output

R1 R4
2 5
+ Input R2 R3 - Input

3 4
+ Output

 Recommended footprint

 Ordering information
A Pressure type B Pressure range
MPS-3 1 1 7-006 GRC G Gauge 001 1 PSI
D 006 5.8 PSI
E C Feature 015 15 PSI
A 3 3.3kOhm 030 30 PSI
7 High sensitivity 100 100 PSI
B 8 Low sensitivity D Cover Material
C E Lead direction C Plastic cover
R The same direction as the tube
N/A Opposite direction to the tube

Part No. Pressure type Pressure range Feature Note


MPS-3117-001GC / GRC Gauge 1 PSI 5kΩ Plastic cover
MPS-3113-006GC / GRC Gauge 5.8 PSI 3.3kΩ Plastic cover
MPS-3117-006GC / GRC Gauge 5.8 PSI 5kΩ High sensitivity
MPS-3118-006GC / GRC Gauge 5.8 PSI 5kΩ Plastic cover
MPS-3113-015GC / GRC Gauge 15 PSI 3.3Ω Plastic cover
MPS-3117-015GC / GRC Gauge 15 PSI 5kΩ High sensitivity
MPS-3118-015GC / GRC Gauge 15 PSI 5kΩ Plastic cover
MPS-3118-030GC / GRC Gauge 30 PSI 5kΩ Plastic cover
MPS-3118-100GC / GRC Gauge 100 PSI 5kΩ Plastic cover
Metrodyne Microsystem Corp.
10, Prosperity Rd.Ⅱ, Science-Based Industrial Park, Hsin-Chu 300, Taiwan, R.O.C.
Tel:886-3-5632161 Fax:886-3-5632509
E-mail:sales@metrodyne.com.tw http://www.metrodyne.com.tw