AMS5612
AMS5612
AMS5612
TYPICAL APPLICATIONS
• Industrial control
• Medical equipment
• Respiration control
• Level detection
• Flow measurement
• Barometric pressure measurement
• Vacuum monitoring
• Heating, Ventilation and Air Conditioning
(HVAC)
PRESSURE RANGES
Sensor type (code) Pressure type Pressure Burst Pressure Burst
1) 1)
range pressure range pressure
in PSI in PSI in mbar in bar
Low pressure
AMS 5612-0003-D differential 0 .. 0.3 >3 0 .. 20.68 > 0.2
AMS 5612-0008-D differential 0 .. 0.8 >8 0 .. 55.16 > 0.5
AMS 5612-0015-D differential 0 .. 1.5 > 15 0 .. 103.4 >1
AMS 5612-0030-D differential 0…3 > 30 0 .. 206.8 >2
Notes:
1) Burst pressure is defined as the maximum pressure which can be applied to one pressure port relative to the other
port (or while only one pressure port is connected) without causing leaks in the sensor.
MAXIMUM RATINGS
Parameter Minimum Typical Maximum Units
Maximum supply voltage: VS,max 20 V
1)
Operating and storage temperature: T -40 125 °C
2)
Common mode pressure: pCM 175 PSI
Notes:
1) Temperature effects on offset and span are only specified within a temperature range of 0 .. 60 °C. For negative tem-
perature the thermal effect on span becomes increasingly nonlinear.
2) Common mode pressure is defined as the maximum pressure, which can be applied simultaneously on both pressure
ports of a differential or relative / gage transmitter without causing damages, while no differential pressure is applied.
www.analogmicro.de
SPECIFICATIONS
All parameters apply to VS = 10.0 V and Top = 25 °C, unless otherwise stated.
Parameter Minimum Typical Maximum Units
1)
Supply voltage (VS) >0 10 20 V
2)
Analog output signal
3)
@ specified minimum pressure (offset) -2.0 0 2.0 mV
4)
Full span output (FSO) – low pressure sensors 24.5 25.0 25.5 mV
4)
Full span output (FSO) – standard pressure sensors 39.5 40.0 40.5 mV
Performance @ T = 25 °C
5), 6)
Nonlinearity ± 0.3 %FSO
Repeatability ± 0.05 ± 0.2 %FSO
Pressure hysteresis ± 0.05 ± 0.2 %FSO
Temperature Performance (range T = 0 .. 60 °C)
7)
Thermal effect on span ± 1.00 %FSO
8)
Thermal effect on offset ± 1.00 %FSO
Temperature hysteresis ± 0.30 %FSO
Impedance
Input 4.50 8.0 25.0 kΩ
Output 2.00 2.50 3.80 kΩ
9)
Position sensitivity (low press. sensors only) < 0.15 %FSO
Long-term stability < 1.0 %FSO/a
6
Pressure changes 10
Calibrated temperature range 0 60 °C
Weight 3 g
10), 11)
Media compatibility See “Specification notes”
Table 3: Specifications
SPECIFICATION NOTES
1) Supply voltage is defined as voltage between pin 4 and pin 2 (see Figure 2).
2) The analog output signal is ratiometric to the supply voltage.
3) See Table 1
4) The specified Full Span Output (FSO) is the algebraic difference between the output signal at the specified
maximum pressure and the output signal at the specified minimum pressure at VS = 10 V.
5) The maximum deviation from the best fit straight line across the specified pressure range.
6) For AMS 5612-0150-G nonlinearity is smaller than 0.5 %FSO.
7) Thermal effect on span is defined as the maximum deviation from the span value at room temperature measured
at any temperature within the compensated temperature range. It is given in %FSO.
8) Thermal effect on offset is defined as the maximum deviation from the offset value at room temperature measured
at any temperature within the compensated temperature range. It is given in %FSO.
9) The position sensitivity is defined as the maximum change in output due to a change in orientation relative to the
Earth's gravitational field, when no pressure difference is applied.
10) Media compatibility of port 1 (see Figure 2): fluids and gases non-corrosive to silicon, Pyrex, RTV silicone rubber.
11) Media compatibility of port 2 (see Figure 2): clean, dry gases, non-corrosive to silicon, RTV silicone rubber,
aluminium, gold (alkaline or acidic liquids can destroy the sensor).
www.analogmicro.de
EQUIVALENT CIRCUIT
The equivalent circuit of the AMS 5612 series is shown in Figure 1.
INITIAL OPERATION
The sensors are connected electrically by mounting them on a PCB. The supply voltage has to be connected
between pin 4 and pin 2. The differential output voltage is given between pin 3 and pin 1.
Important: DO NOT connect to unlabeled pins (pin 5 .. pin 8)!
The sensor pressure connection is made using the metal pressure ports (hose connectors) on top of the
ceramic substrate. Depending on the type of sensor and measuring pressure one or two of the pressure
ports have to be connected to the measuring media / volume.
Port 1 is connected to the back side of the sensor die, port 2 is connected to the top side of the die (for port
definitions see Figure 2). Positive pressure is defined as entry on the back side of the die.
The output voltage of the sensor is positive, if the following conditions are fulfilled (according to the definition
p1 = pressure at port 1 and p2 = pressure at port 2):
The guidelines governing media compatibility must be taken into account here (see “Specification notes”, 10)
and 11)).
www.analogmicro.de
Figure 2: Dimensions
All sensors in the AMS 5612 series are maintenance free during their lifetime.
Notes:
1. For absolute pressure types only pressure port 2 is available.
2. A package without tubes (for O-ring sealing) is also possible.
3. For pressure connections up to 30 PSI Analog Microelectronics recommends silicone tubing (inner diameter
Ø=2mm, outer diameter Ø=6mm).
www.analogmicro.de
AMS 5612-0015-D
Pressure range
Pressure range:
Pressure range code PSI mbar kPa
0003 0.3 20.68 2.068
0008 0.8 55.16 5.516
0015 1.5 103.4 10.34
0030 3.0 206.8 20.68
0050 5.0 344.7 34.47
0150 15 1034 103.4
Pressure type:
Pressure type code Available pressure ranges
D differential / relative (gage) 0 .. 0.3 PSI to 0 .. 15 PSI
G gage (relative) 0 .. 0.3 PSI to 0 .. 15 PSI
A absolute 0 .. 15 PSI
Analog Microelectronics GmbH reserves the right to amend any dimensions, technical data or other information contained herein without prior notification.
www.analogmicro.de