PRODUCT DATA SHEET

Sikalastic®-632 R
SINGLE COMPONENT, LIQUID APPLIED, RAPID CURE, PURE POLYURETHANE ROOF WATERPROOF-
ING MEMBRANE

DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sikalastic®-632 R is a rapid cure, one component, mois- ▪ 1 component pure polyurethane
ture-triggered, pure polyurethane, liquid applied ▪ 1 material for horizontal / vertical areas
membrane based on unique i-Cure® technology ▪ 1 hour early rain resistant
▪ UV resistant
USES ▪ High solid content
▪ Root penetration resistant
Exposed or concealed waterproofing membrane on
flat or pitched roofs both for new construction and re- APPROVALS / STANDARDS
furbishment of old roofs.
▪ Root resistance report no. P 10565a-E, Kiwa GmBH
▪ Korea Testing and Research Institute, report no. KTR-
QP-T09-F01-02(05)

PRODUCT INFORMATION
Composition One component moisture triggered pure polyurethane
Packaging 21 kg pails
Colour Light grey
Shelf Life 6 months from the date of production
Storage Conditions Store in dry condition in original, unopened and undamaged packaging at
temperature between +10 °C and +30 °C. Keep away from direct sunlight.
Density ~1.40 kg/l (EN ISO 1183-1)

Solid content by weight 90 % (+23 °C / 50 % r.h.)


Solid content by volume 82.3 % (+23 °C / 50 % r.h.)

TECHNICAL INFORMATION
Tensile Strength 4.0 MPa (ASTM D412, Die-C)

Elongation at Break 600 % (ASTM D412, Die-C)

Tear Strength ≥ 15 kN/m (ASTM D624, Die-C)

Crack Bridging Ability up to 2 mm (no cracks) (ASTM C836)

Resistance to Root Penetration Pass (DIN 4062)

Product Data Sheet


Sikalastic®-632 R
August 2017, Version 02.02
020915205000000035

1/4
SYSTEM INFORMATION
System Structure Substrate Priming
Substrate Primer
Concrete / Cementitious Substrate Sikalastic® U-Primer
Asphalt / Bituminous Sheet Normally not required *
Metal - Ferrous or galvanised Sikalastic® Metal Primer
metals, lead, copper, aluminium,
brass or stainless steel
Any other substrate Contact Sika Technical Service team
* Color change to cured Sikalastic®-632 R may occur

Build-up
Coating System Reinforced System
Min. 2 x Sikalastic®-632 R * 1 x Sikalastic®-632 R fully rein-
forced with Sikalastic® Fleece or
Sika® Reemat
1 x Sikalastic®-632 R
Total consumption ** : 1.05–2.10 Total consumption ** : 1.75–2.45
kg/m² kg/m²
* local reinforcement is recommended with Sikalastic® Fleece, Sika® Ree-
mat, Sika® Flexitape and/or Sika® Flexistrip in areas with high movement,
irregular substrate or to bridge cracks, joints and seams on the substrate as
well as for detailing.
** consumption figures are theoretical and do not allow for any additional
material due to surface porosity, surface profile, variations in level and
wastage.
Dry film thickness Coating System Reinforced System
0.6–1.2 mm 1.1–1.5 mm (including reinforce-
ment)

APPLICATION INFORMATION
Ambient Air Temperature +10 °C min. / +40 °C max.
Relative Air Humidity 85 % r.h. max.
Substrate Temperature +10 °C min. / +45 °C max.
Dew Point Beware of condensation!
The substrate and uncured membrane temperature must be at least 3 °C
above the dew point to reduce the risk of condensation or blooming on the
membrane finish.
Substrate Moisture Content < 4 % pbw moisture content. Test method: Sika®-Tramex meter, CM –
measurement or oven-dry-method.
No rising moisture according to ASTM (Polyethylene-sheet).
Substrate Pre-Treatment Concrete / Cementitious Substrate
New concrete should be cured for at least 28 days. Inspect the concrete, in-
cluding upstands, all areas should be hammer tested. Concrete must be
suitably finished by wood float or steel pan. The surface finish must be uni-
form and free from defects such as laitance, voids or honeycombing.
Mortar joints must be sound and preferably flush pointed. Ensure all
ceramic tiles are sound and securely fastened, replacing obviously broken
or missing sections.
Asphalt / Bituminous Sheet
Volatiles and organics oils in the sheets can cause bleeding and slight non-
detrimental staining. The asphalt must be carefully assessed for moisture
and/or air entrapment, grade and surface finish prior to any coating works
being carried out.

Product Data Sheet


Sikalastic®-632 R
August 2017, Version 02.02
020915205000000035

2/4
Pot Life Sikalastic®-632 R is designed for rapid curing, therefore the material will re-
act with the humidity of the air. Skin formation in the pail starts within 1
hour of opening the pail in hot climate conditions.
Waiting Time / Overcoating Before applying Sikalastic®-632 R on Sikalastic®-632 R allow:
Ambient conditions Minimum waiting time Maximum waiting
time *
+20 °C / 55 % r.h. 6 hours 2 days
+30 °C / 85 % r.h. 3 hours 2 days
Note: Times are approximate and will be affected by the layer thickness,
changing ambient and substrate conditions, particularly temperature and
relative humidity
* After 2 days the surface must be cleaned and primed prior to the applica-
tion of another layer of Sikalastic®-632 R.
Drying Time Ambient condi- Rain resistant * Touch dry Full cure
tions
+20 °C / 55 % r.h. 2 hours 2 hours 6 hours
+30 °C / 85 % r.h. 1 hour 1 hour 3 hours
* In case of early rain superficial surface damage is expected. However, this
will not affect the integrity of the coating.
Note: The initial surface tackiness of the cured Sikalastic®-632 R will disap-
pear within 2 weeks of application.

APPLICATION INSTRUCTIONS APPLICATION

SUBSTRATE PREPARATION Prior the application of Sikalastic®-632 R the priming


coat if used must have cured tack-free. For the wait-
Concrete Cementitious Substrate ing time / overcoating please refer to the PDS of the
Cementitious or mineral based substrates must be pre- relevant primer. Damageable areas (handrails, etc)
pared mechanically using abrasive blast cleaning or have to be protected with tape or plastic wrapping.
scarifying equipment to remove cement laitance and Application can be done with a soft bristle brush, or
to achieve an open textured surface. Loose friable ma- with a solvent resistant, “non-shedding” synthetic
terial and weak concrete must be completely re- nylon roller. Contact Sika Technical Service team for
moved and surface defects such as blowholes and application using airless spray.
voids must be fully exposed. High spots must be re- Detailing
moved by e.g. grinding. Always begin the installation with the details prior to
Repairs to the substrate, filling of joints, the installation of the horizontal areas. Follow same
blowholes/voids and surface levelling must be carried process as reinforced system.
out using appropriate products from the Sikaflex®, Coating System
Sikafloor®, Sikadur® and Sikagard® range of materials. Apply the first layer of Sikalastic®-632 R maintaining a
Outgassing is a naturally occurring phenomenon of wet edge to ensure a seamless membrane. Once the
concrete that can produce pinholes in subsequently first layer has cured enough (see overcoating time win-
applied coatings. Primers will be used on porous con- dow) apply the second layer of Sikalastic®-632 R.
crete and cementitious substrates to block outgassing, Reinforced System
thereby minimising pin-holing. Apply the first layer of Sikalastic®-632 R maintaining a
Asphalt / Bituminous Sheet wet edge to ensure a seamless membrane. Roll-in the
Power wash as required. All major cracks should be reinforcement Sika® Reemat or Sikalastic® Fleece and
sealed to allow continuity of the Sikalastic®-632 R sys- overlap by minimum 5 cm. The roller may require only
tem. Asphalt must be carefully assessed for moisture a little bit of extra material to keep wetted but no fur-
and/ or air entrapment, grade and surface finish prior ther significant material is added at this stage. Once
to any coating works being carried out. Treat blisters the first layer has cured enough (see overcoating time
by star cutting and removing any underlying water. Al- window) apply the second layer of Sikalastic®-632 R.
low to dry and re-adhere using torch.
Any other substrate CLEANING OF TOOLS
For any other substrate to be waterproofed with Clean all tools and application equipment with Thin-
Sikalastic®-632 R please contact Sika Technical Service ner C immediately after use. Hardened and/or cured
team for assessment and substrate preparation pro- material can only be removed mechanically.
posal.

Product Data Sheet


Sikalastic®-632 R
August 2017, Version 02.02
020915205000000035

3/4
IMPORTANT CONSIDERATIONS ECOLOGY, HEALTH AND SAFETY
▪ Do not apply Sikalastic®-632 R on substrates with For information and advice on the safe handling, stor-
rising moisture. age and disposal of chemical products, users shall refer
▪ Do not dilute Sikalastic®-632 R with any solvent. to the most recent Safety Data Sheet (SDS) containing
▪ Sikalastic®-632 R is not suitable for permanent water physical, ecological, toxicological and other safety-re-
immersion lated data.
▪ Do not apply Sikalastic®-632 R directly or indirectly
on top of insulation boards, even when a separation LEGAL NOTES
layer (eg. concrete, cement boards etc.) is laid
between the insulation boards and Sikalastic®-632 R. The information, and, in particular, the recommenda-
▪ Ponding water test can be conducted on Sikalastic®- tions relating to the application and end-use of Sika
632 R after 24 hours, within maximum test duration products, are given in good faith based on Sika's cur-
of 48 hours. After 48 hours water needs to be re- rent knowledge and experience of the products when
moved. properly stored, handled and applied under normal
▪ On substrates likely to exhibit outgassing, apply dur- conditions in accordance with Sika’s recommenda-
ing falling ambient and substrate temperatures. If ap- tions. In practice, the differences in materials, sub-
plied during rising temperatures “pin holing” may oc- strates and actual site conditions are such that no war-
cur from rising air. ranty in respect of merchantability or of fitness for a
▪ Do not use Sikalastic®-632 R for indoor applications. particular purpose, nor any liability arising out of any
▪ Do not apply Sikalastic®-632 R close to the air intake legal relationship whatsoever, can be inferred either
vent of running air conditioning unit. from this information, or from any written recom-
▪ Volatile bituminous materials may stain and or soften mendations, or from any other advice offered. The
when overcoated with Sikalastic®-632 R. Low melt- user of the product must test the product’s suitability
ing point bituminous materials may need priming. for the intended application and purpose. Sika re-
▪ Whilst Sikalastic®-632 R is resistant to most com- serves the right to change the properties of its
monly encountered atmospheric pollutants, propriet- products. The proprietary rights of third parties must
ary cleaning solutions and environmental spoilage, be observed. All orders are accepted subject to our
contact Sika Technical Service team in case of specif- current terms of sale and delivery. Users must always
ic chemical resistance requirements. refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
BASIS OF PRODUCT DATA be supplied on request.

All technical data stated in this Product Data Sheet are


based on laboratory tests. Actual measured data may
vary due to circumstances beyond our control.

LOCAL RESTRICTIONS
Please note that as a result of specific local regula-
tions the performance of this product may vary from
country to country. Please consult the local Product
Data Sheet for the exact description of the application
fields.

Sika Kimia Sdn. Bhd.


Lot 689, Nilai Industrial Estate, 71800 Nilai
Negeri Sembilan D.K., Malaysia
Phone: +606-7991762
Fax: +606-7991980
e-mail: info@my.sika.com
Website: www.sika.com.my

Sikalastic-632R-en-MY-(08-2017)-2-2.pdf

Product Data Sheet


Sikalastic®-632 R
August 2017, Version 02.02
020915205000000035

4/4

You might also like