Sikalastic 632 R (MY)
Sikalastic 632 R (MY)
Sikalastic 632 R (MY)
Sikalastic®-632 R
SINGLE COMPONENT, LIQUID APPLIED, RAPID CURE, PURE POLYURETHANE ROOF WATERPROOF-
ING MEMBRANE
PRODUCT INFORMATION
Composition One component moisture triggered pure polyurethane
Packaging 21 kg pails
Colour Light grey
Shelf Life 6 months from the date of production
Storage Conditions Store in dry condition in original, unopened and undamaged packaging at
temperature between +10 °C and +30 °C. Keep away from direct sunlight.
Density ~1.40 kg/l (EN ISO 1183-1)
TECHNICAL INFORMATION
Tensile Strength 4.0 MPa (ASTM D412, Die-C)
1/4
SYSTEM INFORMATION
System Structure Substrate Priming
Substrate Primer
Concrete / Cementitious Substrate Sikalastic® U-Primer
Asphalt / Bituminous Sheet Normally not required *
Metal - Ferrous or galvanised Sikalastic® Metal Primer
metals, lead, copper, aluminium,
brass or stainless steel
Any other substrate Contact Sika Technical Service team
* Color change to cured Sikalastic®-632 R may occur
Build-up
Coating System Reinforced System
Min. 2 x Sikalastic®-632 R * 1 x Sikalastic®-632 R fully rein-
forced with Sikalastic® Fleece or
Sika® Reemat
1 x Sikalastic®-632 R
Total consumption ** : 1.05–2.10 Total consumption ** : 1.75–2.45
kg/m² kg/m²
* local reinforcement is recommended with Sikalastic® Fleece, Sika® Ree-
mat, Sika® Flexitape and/or Sika® Flexistrip in areas with high movement,
irregular substrate or to bridge cracks, joints and seams on the substrate as
well as for detailing.
** consumption figures are theoretical and do not allow for any additional
material due to surface porosity, surface profile, variations in level and
wastage.
Dry film thickness Coating System Reinforced System
0.6–1.2 mm 1.1–1.5 mm (including reinforce-
ment)
APPLICATION INFORMATION
Ambient Air Temperature +10 °C min. / +40 °C max.
Relative Air Humidity 85 % r.h. max.
Substrate Temperature +10 °C min. / +45 °C max.
Dew Point Beware of condensation!
The substrate and uncured membrane temperature must be at least 3 °C
above the dew point to reduce the risk of condensation or blooming on the
membrane finish.
Substrate Moisture Content < 4 % pbw moisture content. Test method: Sika®-Tramex meter, CM –
measurement or oven-dry-method.
No rising moisture according to ASTM (Polyethylene-sheet).
Substrate Pre-Treatment Concrete / Cementitious Substrate
New concrete should be cured for at least 28 days. Inspect the concrete, in-
cluding upstands, all areas should be hammer tested. Concrete must be
suitably finished by wood float or steel pan. The surface finish must be uni-
form and free from defects such as laitance, voids or honeycombing.
Mortar joints must be sound and preferably flush pointed. Ensure all
ceramic tiles are sound and securely fastened, replacing obviously broken
or missing sections.
Asphalt / Bituminous Sheet
Volatiles and organics oils in the sheets can cause bleeding and slight non-
detrimental staining. The asphalt must be carefully assessed for moisture
and/or air entrapment, grade and surface finish prior to any coating works
being carried out.
2/4
Pot Life Sikalastic®-632 R is designed for rapid curing, therefore the material will re-
act with the humidity of the air. Skin formation in the pail starts within 1
hour of opening the pail in hot climate conditions.
Waiting Time / Overcoating Before applying Sikalastic®-632 R on Sikalastic®-632 R allow:
Ambient conditions Minimum waiting time Maximum waiting
time *
+20 °C / 55 % r.h. 6 hours 2 days
+30 °C / 85 % r.h. 3 hours 2 days
Note: Times are approximate and will be affected by the layer thickness,
changing ambient and substrate conditions, particularly temperature and
relative humidity
* After 2 days the surface must be cleaned and primed prior to the applica-
tion of another layer of Sikalastic®-632 R.
Drying Time Ambient condi- Rain resistant * Touch dry Full cure
tions
+20 °C / 55 % r.h. 2 hours 2 hours 6 hours
+30 °C / 85 % r.h. 1 hour 1 hour 3 hours
* In case of early rain superficial surface damage is expected. However, this
will not affect the integrity of the coating.
Note: The initial surface tackiness of the cured Sikalastic®-632 R will disap-
pear within 2 weeks of application.
3/4
IMPORTANT CONSIDERATIONS ECOLOGY, HEALTH AND SAFETY
▪ Do not apply Sikalastic®-632 R on substrates with For information and advice on the safe handling, stor-
rising moisture. age and disposal of chemical products, users shall refer
▪ Do not dilute Sikalastic®-632 R with any solvent. to the most recent Safety Data Sheet (SDS) containing
▪ Sikalastic®-632 R is not suitable for permanent water physical, ecological, toxicological and other safety-re-
immersion lated data.
▪ Do not apply Sikalastic®-632 R directly or indirectly
on top of insulation boards, even when a separation LEGAL NOTES
layer (eg. concrete, cement boards etc.) is laid
between the insulation boards and Sikalastic®-632 R. The information, and, in particular, the recommenda-
▪ Ponding water test can be conducted on Sikalastic®- tions relating to the application and end-use of Sika
632 R after 24 hours, within maximum test duration products, are given in good faith based on Sika's cur-
of 48 hours. After 48 hours water needs to be re- rent knowledge and experience of the products when
moved. properly stored, handled and applied under normal
▪ On substrates likely to exhibit outgassing, apply dur- conditions in accordance with Sika’s recommenda-
ing falling ambient and substrate temperatures. If ap- tions. In practice, the differences in materials, sub-
plied during rising temperatures “pin holing” may oc- strates and actual site conditions are such that no war-
cur from rising air. ranty in respect of merchantability or of fitness for a
▪ Do not use Sikalastic®-632 R for indoor applications. particular purpose, nor any liability arising out of any
▪ Do not apply Sikalastic®-632 R close to the air intake legal relationship whatsoever, can be inferred either
vent of running air conditioning unit. from this information, or from any written recom-
▪ Volatile bituminous materials may stain and or soften mendations, or from any other advice offered. The
when overcoated with Sikalastic®-632 R. Low melt- user of the product must test the product’s suitability
ing point bituminous materials may need priming. for the intended application and purpose. Sika re-
▪ Whilst Sikalastic®-632 R is resistant to most com- serves the right to change the properties of its
monly encountered atmospheric pollutants, propriet- products. The proprietary rights of third parties must
ary cleaning solutions and environmental spoilage, be observed. All orders are accepted subject to our
contact Sika Technical Service team in case of specif- current terms of sale and delivery. Users must always
ic chemical resistance requirements. refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
BASIS OF PRODUCT DATA be supplied on request.
LOCAL RESTRICTIONS
Please note that as a result of specific local regula-
tions the performance of this product may vary from
country to country. Please consult the local Product
Data Sheet for the exact description of the application
fields.
Sikalastic-632R-en-MY-(08-2017)-2-2.pdf
4/4