Nave Orbit - Q88
Nave Orbit - Q88
Nave Orbit - Q88
1. General Information
1.2b Is the vessel owner/manager a member of INTERTANKO? If yes, please provide Yes, 5620260
IMO number of the Member organization
1.3 Vessel's previous name(s) and date(s) of change: BUDDY (Oct 10, 2014)
1.4 Date delivered / Builder (where built): Oct 14, 2009 / SPP Shipbuilding LTD. S.KOREA
1.7 Vessel's contact details (satcom/fax/email etc.): Tel: +44 2036955215 , +870 773064901
Email: N-Orbit@SkyFile.com
1.8 Type of vessel (as described in Form A or Form B Q1.11 of the IOPPC): Oil Tanker
Insurance
1.15 P & I Club pollution liability coverage / expiration date: 1,000,000,000 US$ Feb 20, 2025
1.16 Hull & Machinery insured by - Full Style: WTW & AUSCOMAR SRL
(Specify broker or leading underwriter)
1.17 Hull & Machinery insured value / expiration date: 36,000,000 US$ Jul 07, 2025
Classification
1.19 Class notation: 1A1 TANKER FOR CHEMICAL AND OIL BIS E0 ESP
NAUTICUS(NEWBUILDING) SPM TMON VCS(2)
1.20 Does the vessel have any open conditions of Class?? If yes List all open conditions: No
1.20a Does the vessel have any Memoranda of Class? If yes, list details: No
1.21 If classification society changed, name of previous and date of change: , Not Applicable
1.22 Does the vessel have ice class? If yes, state what level: No, N/A
1.23 Date / place of last dry-dock: Jan 25, 2020 / TUZLA SHIPYARD, TURKEY
1.24 Date next dry dock due / next annual survey due: Oct 14, 2024
about:blank 1/13
9/25/24, 1:51 PM about:blank
1.25 Date of last special survey / next special survey due: Jan 25, 2020 Oct 14, 2024
1.26 If ship has Condition Assessment Program (CAP), what is the latest overall rating: No, NA
Dimensions
1.31 Keel to masthead (KTM) / Keel to masthead (KTM) in collapsed condition, if 46.40 m m
applicable:
1.33 Bow to center manifold (BCM) / Stern to center manifold (SCM): 90.10 m 92.90 m
Tonnages
1.36 Gross Tonnage / Reduced Gross Tonnage (if applicable): 30,083.00 22,794
1.37 Suez Canal Tonnage - Gross (SCGT) / Net (SCNT): 31,590.67 27,018.19
1.38 Is vessel fitted for transit of Panama Canal? Panama Canal Net Tonnage (PCNT): Yes, 25,001.00
Loadline Information
1.41 Have multiple deadweights been assigned? If yes, list all assigned deadweights: Yes
Assigned DWT 1: 49,999
Assigned DWT 2: 44,999
Assigned DWT 3: 39,999
Assigned DWT 4: 34,999
Assigned DWT 5:
1.43 What is the company guidelines for Under Keel Clearance (UKC) for this vessel? The company policy regarding the minimum UKC is 20% of the deepest
draught in Ocean passages/ open waters; 15% of the deepest draught in
coastal waters and 10% of the deepest draught inside ports.
1.44 What is the max height of mast above waterline (air draft) Full Mast Collapsed Mast
Lightship: 43.66 m 0m
2.1 Safety Nov 26, 2021 Nov 21, 2023 Oct 12, 2022 Oct 14, 2024
Equipment
Certificate
(SEC):
2.2 Safety Radio Nov 26, 2021 Nov 21, 2023 Oct 12, 2022 Oct 14, 2024
Certificate
(SRC):
about:blank 2/13
9/25/24, 1:51 PM about:blank
2.3 Safety Nov 26, 2021 Nov 21, 2023 Nov 05, 2022 Oct 14, 2024
Construction
Certificate
(SCC):
2.4 International Jan 25, 2020 Nov 21, 2023 Oct 14, 2024
Loadline
Certificate
(ILC):
2.5 International Oil Nov 16, 2021 Nov 21, 2023 Oct 12, 2022 Oct 14, 2024
Pollution
Prevention
Certificate
(IOPPC):
2.6 International Nov 16, 2021 Not Applicable Nov 05, 2022 Jan 25, 2025
Ship Security
Certificate
(ISSC):
2.7 Maritime Jan 25, 2020 Not Applicable Nov 05, 2022 Jan 25, 2025
Labour
Certificate
(MLC):
2.8 Minimum Safe Oct 13, 2023 Not Applicable Not Applicable Not Applicable
Manning
Certificate
(MSM):
2.9 ISM Safety Nov 16, 2021 Not Applicable Nov 05, 2022 Jan 25, 2025
Management
Certificate
(SMC):
2.11 USCG Jun 27, 2023 Not Applicable Not Applicable Jun 27, 2025
Certificate of
Compliance
(USCGCOC):
2.12 Civil Liability Feb 03, 2024 Not Applicable Not Applicable Feb 20, 2025
Convention
(CLC) 1992
Certificate:
2.13 Civil Liability for Feb 03, 2024 Not Applicable Not Applicable Feb 20, 2025
Bunker Oil
Pollution
Damage
Convention
(CLBC)
Certificate:
2.14 Liability for the Feb 03, 2024 Not Applicable Not Applicable Feb 20, 2025
Removal of
Wrecks
Certificate
(WRC):
2.15 U.S. Certificate Oct 21, 2023 Not Applicable Not Applicable Oct 21, 2026
of Financial
Responsibility
(COFR):
2.16 Certificate of May 31, 2024 Nov 21, 2023 Nov 05, 2022 Oct 14, 2024
Class (COC):
2.18 International Jan 25, 2020 Not Applicable Not Applicable Oct 14, 2024
Sewage
Pollution
Prevention
Certificate
(ISPPC)
2.19 Certificate of Nov 16, 2021 Nov 21, 2023 Not Applicable Oct 14, 2024
Fitness (COF):
2.20 International Mar 14, 2024 Not Applicable Not Applicable Not Applicable
Energy
Efficiency
Certificate
(IEEC):
2.21 International Air Nov 16, 2021 Jan 12, 2024 Oct 12, 2022 Oct 14, 2024
Pollution
Prevention
Certificate
(IAPPC):
about:blank 3/13
9/25/24, 1:51 PM about:blank
2.22 Ship Sanitation May 20, 2024 Not Applicable Not Applicable Nov 16, 2024
Control
(SSCC)/Ship
Sanitation
Control
Exemption
(SSCE):
2.23 Does the vessel have an International Ballast Water Management Certificate? If no, Yes, N/A
then describe how ship complies with the "International Convention for the Control
and Management of Ships' Ballast Water and Sediments"?:
Documentation
2.24 Owner warrant that vessel is member of ITOPF and will remain so for the entire Yes
duration of this voyage/contract:
2.25 Does vessel have in place a Drug and Alcohol Policy complying with OCIMF Yes
guidelines for Control of Drugs and Alcohol Onboard Ship?
2.27 ITF Blue Card expiry date (if applicable): Oct 11, 2024
3. CREW
INDIA 9
BRAZIL 5
V.SHIPS - Istanbul Is Merkezi, Cevizli Mah., Tugay Yolu Cad., +90 +90 : istanbul@vships.com /
ISTANBUL No:18, B Blok / Kat:6, Maltepe / Istanbul - TURKEYC/O 216 216 bombay@vships.com
V. SHIPS INDIAWINDSOR CORORATE PARK, BEST 456 50 456
COLONY ROAD, OSHIWARA, MHADA COLONY, 30 60 47
GOREGAONWEST , MUMBAI - INDIA 400102
Ratings:
Company Name Address Phone Fax Email
SAME AS OFFICERS . . . .
4.1 Has the vessel Operator submitted a Vessel Spill Response Plan to the US Coast Yes
Guard which has been approved by official USCG letter?
4.3 Oil Spill Response Organization (OSRO) - Full National Response Corporation
style: 3500 Sunrise Highway Suite T103 Great River, NY 11739
Tel: 24-Hour Emergency: Inside the US +1-800-899-4672 Internati
Fax: (631) 224-9082
Email: iocdo@nrcc.com
Web: http://www.nrcc.com/
4.4 Salvage and Marine Firefighting Services RESOLVE MARINE GROUP, INC
(SMFF) - Full Style: 1510 SE 17th Street, Suite 400, Ft. Lauderdale, FL 33316, USA
Tel: +1.954.764.8700
Email: info@resolvemarine.com
Web: https://resolvemarine.com/
5. SAFETY/HELICOPTER
5.1 Is the vessel operated under a Quality Management System? If Yes, what type of Yes
system? (ISO9001 or IMO Resolution A.741(18) as amended): IMO Resolution A.741(18)
5.2 Can the ship comply with the ICS Helicopter Guidelines? Yes
about:blank 4/13
9/25/24, 1:51 PM about:blank
6. COATING/ANODES
1 P 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
3 P 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
3 S 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
4 P 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Nov 5, 2022 30 Months
4 S 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Nov 5, 2022 30 Months
5 P 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
5 S 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
6 P 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
6 S 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
7 P Slop Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Nov 5, 2022 30 Months
7 S Slop Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Nov 5, 2022 30 Months
1 S 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
2 P 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
2 S 3 Mild Steel Yes Epoxy Full Tank Good Oct 14, 2009 Oct 11, 2022 30 Months
Anodes Fitted: No
Ballast tanks:
ID Coated? Type Extent Condition Coating date Insp date Insp freq
FPK & 1P Yes Epoxy Full Tank Good Oct 14, 2009 Mar 22, 2024 Biannual
1S , 2P/S,4P/S & APK Yes Epoxy Full Tank Good Oct 14, 2009 Apr 05, 2024 Biannual
5 P/S , 6P/S Yes Epoxy Full Tank Good Oct 14, 2009 Apr 04, 2024 Biannual
3 P/S Yes Epoxy Full Tank Good Oct 14, 2009 May 28, 2024 Biannual
7. BALLAST
7.3 Does the vessel have a Ballast Water Treatment System (BWTS) fitted? Yes
7.4 What type of BWTS fitted? If other system fitted, please advise: Other (specify), FILTRATION + ELECTROLYSIS
8. Cargo- Oil/Chem
8.1 Is vessel fitted with centerline bulkhead in all cargo tanks? If Yes, solid or perforated: Yes, Solid
Tank Capacities
about:blank 5/13
9/25/24, 1:51 PM about:blank
Total Deck: m3
8.2.1 Capacity (98%) of each natural segregation with double valve (specify tanks): Seg#1: 6150.23 m3 (1p + 1s)
Seg#2: 9232.98 m3 (2p + 2s)
Seg#3: 9414.165 m3 (3p + 3s)
Seg#4: 9410.32 m3 (4p + 4s)
Seg#5: 9413.52 m3 (5p + 5s)
Seg#6: 8510.48 m3 (6p + 6s)
Total: 1,403.58 m3
8.3.1 Specify segregations which slops tanks belong to and their capacity with double N/A
valve:
SBT Vessels
8.3.3 What is total SBT capacity and percentage of SDWT vessel can maintain? N/A N/A
8.3.4 Does vessel meet the requirements of MARPOL Annex I Reg 18.2: N/A
8.4 How many grades/products can vessel load/discharge with double valve 6
segregation:
8.4.1 State type of cargo containment (integral, independent, gravity or pressure tanks): INTEGRAL
8.6 Max loading rate for homogenous cargo With VECS Without VECS
8.8 Can tank innage / ullage be read from the CCR? Yes
about:blank 6/13
9/25/24, 1:51 PM about:blank
8.9 Is gauging system certified and calibrated? If no, specify which ones are not Yes, NA
calibrated:
What type of gauging system as per IBC 13.1 is fitted (Open/Restricted/Closed): Closed
Is a tank overflow control system fitted? If yes, then state if system includes Yes, No
automatic closing of valves?
Are high level alarms fitted to the cargo tanks? If Yes, indicate whether to all tanks or Yes, Yes
partial:
8.9.1 Can cargo be transferred under closed loading conditions in accordance with N/A
ISGOTT 11.1.6.6?
8.9.2 Are cargo tanks fitted with multipoint gauging? If yes, specify type and locations: Yes, (EACH TANK FITTED WITH SINGLE GAUGING POINT FOR MANUAL
ULLAGING, ADDITIONALLY FITTED WITH TANK RADAR (KONSBERG)
FOR AUTOMATIC READINGS)
If fitted, is vapour line return manifold in compliance with OCIMF Guidelines? Yes
If fitted, how many vapor return segregations can the vessel maintain 1
simultaneously?
Does the ship possess Vapour Emission Control (VEC) Certification? If yes, state Yes, DNV
the issuing authority
8.13 Number / size / type of VECS reducers: 2 X 12 (on each side) + 2 Reducers 16x 12
Venting
8.14 State what type of venting system is fitted: PV VALVES, MAST RISER
Size:
Manifold PCS Size Unit Pressure Rating Unit PR Standard
8.17.1 Does vessel comply with the latest edition of the OCIMF 'Recommendations for Oil Yes
Tanker Manifolds and Associated Equipment'?
about:blank 7/13
9/25/24, 1:51 PM about:blank
8.24 Manifold height above the waterline in normal ballast / at SDWT condition: 13.80 m 8.25 m
8.26 Is vessel fitted with a stern manifold? If yes, state size: No, 0 mm
Heating
8.27.1 Is a Thermal Oil Heating system fitted? If yes, identify tanks? No, NA
8.28 Maximum temperature cargo can be loaded / maintained: 73.9 °C / 165.0 °F 57 °C / 134.6 °F
8.29.1 Is a Crude Oil Washing (COW) installation fitted / operational? N/A / N/A
8.30 Is IGS supplied by flue gas, inert gas (IG) generator and/or nitrogen: IG Generator
8.30.1 If nitrogen generator, specify the applicable flow rate for each of the designed purity NA
modes:
Cargo Pumps
8.31 How many cargo pumps can be run simultaneously at full capacity: 6
Pump Identity Pump Location Type Type of prime mover Capacity At what head?
SLOP TANKS CARGO PUMPS Cargo Tank Centrifugal Hydraulic 300 125
8.37 Is a washing water heater fitted? If yes is it operational and state max washing water Yes, Yes
temperature: 70.00 °C
8.38 What is the maximum number of machines that can be operated at their designed 4
max pressure?
about:blank 8/13
9/25/24, 1:51 PM about:blank
8.39 Is vessel fitted with a remote cargo tank temperature monitoring system. If yes, is it Yes, Yes
operational?
8.40 Is vessel fitted with a remote cargo tank pressure monitoring system. If yes, is it Yes, Yes
operational?
8.41 Is vessel fitted with a cargo tank drier. If yes is it operational and state capacity: No, N/A
0 m3/hr
8.42 Is vessel fitted with a cargo cooling system. If yes is it operational and state tanks No, N/A
applicable: NA
9. MOORING
9.1 Provide details for Mooring Ropes, Wires, Tails and Shackles
WLL
LDBF(100- TDBF(125-
Location (tonnes) Status
105 % of 130 % of SWL Installed Reversed Renewal2 Condition
Type and Material Diameter/size Length (50-55% Certificate No. of
SDMBL SDMBL (tonnes) Date Date Date of line/tail
Identity of Max line/tail
(Tonnes)) (Tonnes)
LDBF)
Ropes FWD P MIXED 51 220 51.8 51.8 51.8 51.8 200203014020 Jan 10, Feb 10, Jan 10, In Use Suitable
WINCH POLYOLEFINS 2020 2024 2020
P & HTPES
Ropes FWD P MIXED 51 220 51.8 51.8 51.8 51.8 200203014001 Jan 10, Feb 10, Jan 10, In Use Suitable
WINCH POLYOLEFINS 2020 2024 2020
S & HTPES
Ropes FWD S MIXED 51 220 51.8 51.8 51.8 51.8 200203014002 Jan 10, Feb 10, Jan 10, In Use Suitable
WINCN POLYOLEFINS 2020 2024 2020
P & HTPES
Ropes FWD S MIXED 51 220 51.8 51.8 51.8 51.8 200203014019 Jan 10, Feb 10, Jan 10, In Use Suitable
WINCH POLYOLEFINS 2020 2024 2020
S & HTPES
Ropes FWD MIXED 51 220 51.8 51.8 51.8 51.8 200203014005 Jan 10, Feb 10, Jan 10, In Use Suitable
MAIN POLYOLEFINS 2020 2024 2020
DECK & HTPES
FWD -
FWD
Ropes FWD MIXED 51 220 51.8 51.8 51.8 51.8 200203014006 Jan 10, Feb 10, Jan 10, In Use Suitable
MAIN POLYOLEFINS 2020 2024 2020
DECK & HTPES
FWD-
AFT
Ropes FWD MIXED 51 220 51.8 51.8 51.8 51.8 200203014003 Jan 10, Feb 10, Jan 10, In Use Suitable
MAIN POLYOLEFINS 2020 2024 2020
DECK & HTPES
AFT-
FWD
Ropes FWD MIXED 51 220 51.8 51.8 51.8 51.8 200203014004 Jan 10, Feb 10, Jan 10, In Use Suitable
MAIN POLYOLEFINS 2020 2024 2020
DECK & HTPES
AFT-
AFT
Ropes AFT MIXED 51 220 51.8 51.8 51.8 51.8 200203014018 Jan 10, Feb 10, Jan 10, In Use Suitable
MAIN POLYOLEFINS 2020 2024 2020
DECK & HTPES
FWD-
FWD
Ropes AFT MIXED 51 220 51.8 51.8 51.8 51.8 200203014017 Jan 10, Feb 10, Jan 10, In Use Suitable
MAIN POLYOLEFINS 2020 2024 2020
DECK & HTPES
FWD-
AFT
Ropes AFT MIXED 51 220 51.8 51.8 51.8 51.8 200203014007 Jan 10, Feb 10, Jan 10, In Use Suitable
MAIN POLYOLEFINS 2020 2024 2020
DECK & HTPES
AFT-
FWD
Ropes AFT MIXED 51 220 51.8 51.8 51.8 51.8 200203014008 Jan 10, Feb 10, Jan 10, In Use Suitable
MAIN POLYOLEFINS 2020 2024 2020
DECK & HTPES
AFT-
AFT
Ropes POOP MIXED 51 220 51.8 51.8 51.8 51.8 200203014009 Jan 10, Feb 10, Jan 10, In Use Suitable
P POLYOLEFINS 2020 2024 2020
WHICH & HTPES
P
about:blank 9/13
9/25/24, 1:51 PM about:blank
WLL
LDBF(100- TDBF(125-
Location (tonnes) Status
105 % of 130 % of SWL Installed Reversed Renewal2 Condition
Type and Material Diameter/size Length (50-55% Certificate No. of
SDMBL SDMBL (tonnes) Date Date Date of line/tail
Identity of Max line/tail
(Tonnes)) (Tonnes)
LDBF)
Ropes POOP MIXED 51 220 51.8 51.8 51.8 51.8 200203014010 Jan 10, Feb 10, Jan 10, In Use Suitable
P POLYOLEFINS 2020 2024 2020
WHICH & HTPES
S
Ropes POOP MIXED 51 220 51.8 51.8 51.8 51.8 200203014016 Jan 10, Feb 10, Jan 10, In Use Suitable
S POLYOLEFINS 2020 2024 2020
WINCH & HTPES
P
Ropes POOP MIXED 51 220 51.8 51.8 51.8 51.8 200203014015 Jan 10, Feb 10, Jan 10, In Use Suitable
S POLYOLEFINS 2020 2024 2020
WHICH & HTPES
S
Date of
Mooring Remote Designed Brake Operational brake Brake
Split Motive Heaving Hauling Type of last Frequency of
winch Operational Max holding load holding load (60% Rendering
Drum Power power Speed Brake brake testing brakes
Location controls (ISO) (80% of SDMB of SDMBL) load
test
1 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
2 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
3 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
4 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
5 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
6 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
7 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
8 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
9 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
10 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
11 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
12 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
13 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
14 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
15 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
16 Yes Hydraulic Yes 16 15 Manual 40.8 30.6 Jan 05, 30.6 ANNUAL
2024
Forecastle 4 . 400 64
Forecastle 2 . 400 51
about:blank 10/13
9/25/24, 1:51 PM about:blank
Location Identity No Certificate Number Size (mm) SWL (tonnes)
Type Location Identity No Certificate Size (mm) SWL (tonnes) Modifications If yes, are modifications class approved?
9.7 Type / SWL of Emergency Towing system aft: KETSP -40 A 200 MT
9.8 What is size of closed chock and/or fairleads of enclosed type on stern: 1160 X 504 X 1130
Escort Tug
9.9 What is SWL of closed chock and/or fairleads of enclosed type on stern: 200.00 MT
9.10 What is SWL of bollard on poop deck suitable for escort tug: 200.00 MT
Lifting Equipment/Gangway
9.11 Derrick / Crane description (Number, SWL and location): Cranes: 1 x 10.00 Tonnes
CENTER
9.13 Does vessel have a portable gangway? If yes, state length: Yes 12.135 m
9.14 Does the vessel meet the recommendations in the latest edition of OCIMF Yes
'Recommendations for Equipment Employed in the Bow Mooring of Conventional
Tankers at Single Point Moorings (SPM)'?
9.17 Distance between the bow fairlead and chain stopper/bracket: 3,700.00 m
9.18 Is bow chock and/or fairlead of enclosed type of OCIMF recommended size (600mm Yes
x 450mm)? If not, give details of size: N/A
10. PROPULSION
10.2 What type of fuel is used for main propulsion? If other, then specify: Other (specify), VLSFO
What type of fuel is used for generating plant 380 CST FUEL OIL
about:blank 11/13
9/25/24, 1:51 PM about:blank
Tank Name Bunker Type Tank Type Capacity Max Pressure
Bow/Stern Thruster
10.6 What is brake horse power of bow thruster (if fitted): No, bhp
10.7 What is brake horse power of stern thruster (if fitted): No, bhp
Environmental/Emissions
10.8 Does the vessel have an EEDI Rating number? If yes then provide EEDI rating: No,
If No then provide reason: The Ship is exempt under regulation 20.1 as it is not a new ship as defined in
regulation 2.23
10.9 Does the vessel have an EEXI Rating number? If yes then provide EEXI rating: No,
10.10 Does the vessel have a CII Rating number? If yes then provide CII rating: Yes, D
10.11 Does the vessel have an EIV Rating number? If yes then provide EIV rating: ,
10.12 What is the ships NOx control level (Tier I, Tier II, and Tier III)?: Tier I
List of equipment fitted for NOx Tier III achievement for all engines (LP Selective
catalytic reduction, HP Selective catalytic reduction, Exhaust gas recirculation,
Alternative fuel etc...)
10.14 What is the type of scrubber fitted as part of the EGCS onboard?
11.1 Does vessel comply with recommendations contained in OCIMF/ICS Ship To Ship Yes
Transfer Guide (Petroleum, Chemicals or Liquified Gas, as applicable)?
11.2 What is maximum outreach of cranes / derricks outboard of the ship's side: 7.00 m
about:blank 12/13
9/25/24, 1:51 PM about:blank
12.1 Last three cargoes / charterers / voyages (Last / 2nd Last / 3rd Last):
12.2 Has ship been involved in a pollution, grounding, collision or allision incident during the past 12 months? If yes, provide details:
No
12.3 Date and place of last Port State Control inspection: Jun 28, 2024, São Luís
12.4 Any outstanding deficiencies as reported by any Port State Control? If yes, provide No
details: No outstanding deficiency
12.5 Recent Oil company inspections/screenings (To the best of owners knowledge and MOTOR OIL (HELLAS), KOCH, MAXCOM Petroli Spa, ENOC, NESTE OIL,
without guarantee of acceptance for future business)*: CHEVRON, EQUINOR, KMG, BP, SHELL, PHILLIPS66, BHP-RIGHTSHIP
*"Approvals" are not given by Oil Majors and ships are accepted for the voyage on a
case by case basis.
12.6 Date / place of last SIRE inspection: May 05, 2024 / SAO SEBASTIAO, BRAZIL
12.7 Additional information relating to features of the ship or operational characteristics: nil
about:blank 13/13