mt172 Ang
mt172 Ang
mt172 Ang
MT172
MT172 is a three-phase multirate meter used for measurement of active or active and reactive energy in threephase four- or three-wire networks. It can be connected directly or via CT. The meter can also be used in single phase two-wire networks. The meters comply with both European (EN 50470-1 and EN 50470-3) and international (IEC 62052-11 and IEC 62053-21) standards, and are designed and manufactured in compliance with the ISO 9001 standard. The kWh- and kvarh-meters comply with the IEC 62052-23 standard.
Poly-phase meter
Active or active and reactive energy One or two energy flow directions or always positive registration Multirate registration Internal real time clock Multi-phasing Pulse output(s) (kWh or kWh + kvarh)
Option: Tariff output(s) instead pulse output(s)
I Fast and easy installation procedure, indications of correct connection I Compact meter case with IP54 protection I Multi-phasing connection (all-in-one: poly- and single-phase meter) I Universal current terminal for all types of conductors I Indications of meter operation status I Very high EMC immunity level I Optical port I Internal real time clock
MT172
Accuracy class (kWh) . . . . . . . .A or B (by EN 50470-3) 2 or 1 (by IEC 62053-21) (kvarh) . . . . . . . . . . . . . . . . . . . . . . . . . .3 or 2 (by IEC 62053-23) Reference / Basic current Ib . . . . . . . . .5, 10, 15, 20 A (directly connected meters) 1 A (CT operated meters) Max. current Imax . . . . . . .40, 60, 80, 85, 100, 120 A (directly connected meters) 6 A (CT operated meters), Min. current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.05 Ib Starting current . . . . . . . . . . . . . . . . . . . . . . .0.004 Ib (directly connected meters) 0.002 Ib (CT operated meters) Reference voltage Ur . . . . . . . . . . . . . . . . . . . . . . . .3 x 230/400 V, 3x230 V, 230 V Voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.8 Ur ... 1.15 Ur Reference frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Hz or 60 Hz Operating temper. range . . . . . . . . . . . . . . .-40C ... +60C (LCD: -25C ... +60C) Extended temper. range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40 C ... +70 C Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40 C ... +85 C Optical port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IEC 62056-21 RTC (IEC 62054-21) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 min/year RTC operation reserve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 years (Li-battery) Pulse output(s) IEC 62053-31, class A (S0) . . . . . . . . . . . .ti = 30 ms (10, 20, 30, ..., 160 ms) Optomos relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ti = 80 ms, ... 160 ms Tariff output(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . .Optional instead impulse output Current circuit burden . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<0.5 VA Voltage circuit burden . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<1 W / 10 VA Dielectric strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 kV, 50 Hz, 1 min Impulse voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 kV, 1.2/50 s option: . . . . . . . . . . . . . . . . . . . . . . . .main circuits 12 kV (aux. circuits: 6 kV) Short-circuit current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Imax Fast transients (burst) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 kV (IEC 61000-4-4) Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 x 178 x 55 mm Mass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 kg
CONNECTION DIAGRAM
MT172D1A41R51V22G22M3K0
M T 172 D1 D2 T1 A4 A5 1 2 4 R5 R6 1 2 V12 V22 G12 G22 L11 L21 M3 K0 Electronic meter Three-phase three-element meter Multi-tariff meter with LCD and RTC Terminal block up to 85 A for direct connection Terminal block up to 120 A for direct connection Terminal block up to 6 A for indirect connection Active energy measurement, accuracy class B (by EN 50470-3) 1 (by IEC 62053-21) Active energy measurement, accuracy class A (by EN 50470-3) 2 (by IEC 62053-21) Measurement in one energy flow direction Measurement in two energy flow directions Measurement in two energy flow directions, absolute registration Reactive energy measurement, accuracy class 2 Reactive energy measurement, accuracy class 3 (option) Measurement in one energy flow direction Measurement in two energy flow directions 1 tariff input 2 tariff inputs 1 pulse output class A by IEC 62053-31(S0 by DIN 43864) 2 pulse outputs class A by IEC 62053-31(S0 by DIN 43864) 1 optomos relay pulse output, make contact (option: tariff output) 2 optomos relay pulse outputs, make contact (option: tariff outputs) RTC with Li-battery as back-up supply Optical port in compliance with IEC 62056-21
136
162
150 178
0709/12
Owing to periodical improvements of our products the supplied products can differ in some details from the data stated in the prospectus material.
Iskraemeco, Energy Measurement and Management 4000 Kranj, Savska loka 4, Slovenia Telephone: (+386 4) 206 40 00, Telefax: (+386 4) 206 43 76, http://www.iskraemeco.si, e-mail: info@iskraemeco.si Published by Iskraemeco. Data subject to alteration without notice.
722.999.178
250