Building Management System: Unit - 1 Bms - Introduction
Building Management System: Unit - 1 Bms - Introduction
Building Management System: Unit - 1 Bms - Introduction
YAR204
UNIT -1
BMS– INTRODUCTION
Benefits of BMS
Building tenant/occupants
•Good control of internal comfort conditions
•Possibility of individual room control
•Increased staff productivity
•Effective monitoring and targeting of energy consumption
•Improved plant reliability and life
•Effective response to HVAC-related complaints
•Save time and money during the maintenance
Benefits of BMS
Building owner
•Higher rental value
•Flexibility on change of building use
•Individual tenant billing for services facilities manager
•Central or remote control and monitoring of building
•Increased level of comfort and time saving
•Remote Monitoring of the plants
(such as AHU's, Fire pumps, plumbing pumps,
Electrical supply, STP, WTP etc.)
Maintenance Companies
•Ease of information availability problem
•Computerized maintenance scheduling
•Effective use of maintenance staff
•Early detection of problems
•More satisfied occupants
Salient Features of BMS
Application specific.
Intelligent monitoring & control system.
Involves participation from the owner,
architect, consultant & the system
integrator.
Improves the quality of environment
Provides information at the click of a
mouse.
Lowers operations cost by reducing Energy
/ Manpower use.
Increases flexibility
Scope of Importance of BMS
• User Friendly
Security
(Access control / Video / Intruder / Perimeter)
Integrated
Systems
Corrective Maintenance.
Difference Between Preventive and Predictive Maintenance
Predictive maintenance tends to include direct measurement of the item.
Examples
An individual bought a incandescent light bulb. The manufacturing
company mentioned that the life span of the bulb is 3 years. Just before
the 3 years, the individual decided to replace the bulb with a new one.
This is called preventive maintenance.
On the other hand, the individual has the opportunity to observe the bulb
operation daily. After two years, the bulb starts flickering. The individual
predicts at that time that the bulb is going to fail very soon and decides
to change it for a new one. This is called predictive maintenance.
The individual ignores the flickering bulb and only goes out to buy
another replacement light bulb when the current one fails. This is called
corrective maintenance.
Building Automation System
LEVEL 4
Fire door actuator, smoke vent controls, sprinkler system valves, fan
control switches.
LEVEL 1
Central computer.