-
Background Rejection in the DMTPC Dark Matter Search Using Charge Signals
Authors:
J. P. Lopez,
D. Dujmic,
S. Ahlen,
J. B. R. Battat,
C. Deaconu,
P. Fisher,
S. Henderson,
A. Inglis,
A. Kaboth,
J. Monroe,
G. Sciolla,
H. Tomita,
H. Wellenstein,
R. Yamamoto
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing a low pressure gas TPC for detecting Weakly Interacting Massive Particle (WIMP)-nucleon interactions. Optical readout with CCD cameras allows for the detection of the daily modulation of the direction of the dark matter wind. In order to reach sensitivities required for WIMP detection, the detector needs to minimize backgr…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing a low pressure gas TPC for detecting Weakly Interacting Massive Particle (WIMP)-nucleon interactions. Optical readout with CCD cameras allows for the detection of the daily modulation of the direction of the dark matter wind. In order to reach sensitivities required for WIMP detection, the detector needs to minimize backgrounds from electron recoils. This paper demonstrates that a simplified CCD analysis achieves $7.3\times10^{-5}$ rejection of electron recoils while a charge analysis yields an electron rejection factor of $3.3\times10^{-4}$ for events with $^{241}$Am-equivalent ionization energy loss between 40 keV and 200 keV. A combined charge and CCD analysis yields a background-limited upper limit of $1.1\times10^{-5}$ (90% confidence level) for the rejection of $γ$ and electron events. Backgrounds from alpha decays from the field cage are eliminated by introducing a veto electrode that surrounds the sensitive region in the TPC. CCD-specific backgrounds are reduced more than two orders of magnitude when requiring a coincidence with the charge readout.
△ Less
Submitted 28 January, 2013; v1 submitted 23 January, 2013;
originally announced January 2013.
-
Background Rejection in the DMTPC Dark Matter Search Using Charge Signals
Authors:
J. P. Lopez,
S. Ahlen,
J. Battat,
T. Caldwell,
M. Chernicoff,
C. Deaconu,
D. Dujmic,
A. Dushkin,
W. Fedus,
P. Fisher,
F. Golub,
S. Henderson,
A. Inglis,
A. Kaboth,
G. Kohse,
L. Kirsch,
R. Lanza,
A. Lee,
J. Monroe,
H. Ouyang,
T. Sahin,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
H. Wellenstein
, et al. (3 additional authors not shown)
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that the addition of the charge readout analysis to the CCD allows us too obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor of $5.6\times10^{-6}$ for recoils with energies between 40 and 200 keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals and light in the CCD reduces CCD-specific backgrounds by more than two orders of magnitude.
△ Less
Submitted 15 September, 2011;
originally announced September 2011.
-
Dark Matter Time Projection Chamber: Recent R&D Results
Authors:
J. B. R. Battat,
S. Ahlen,
M. Chernicoff,
C. Deaconu,
D. Dujmic,
A. Dushkin,
P. Fisher,
S. Henderson,
A. Inglis,
A. Kaboth,
L. Kirsch,
J. P. Lopez,
J. Monroe,
H. Ouyang,
G. Sciolla,
H. Tomita,
H. Wellenstein
Abstract:
The Dark Matter Time Projection Chamber collaboration recently reported a dark matter limit obtained with a 10 liter time projection chamber filled with CF4 gas. The 10 liter detector was capable of 2D tracking (perpendicular to the drift direction) and 2D fiducialization, and only used information from two CCD cameras when identifying tracks and rejecting backgrounds. Since that time, the collabo…
▽ More
The Dark Matter Time Projection Chamber collaboration recently reported a dark matter limit obtained with a 10 liter time projection chamber filled with CF4 gas. The 10 liter detector was capable of 2D tracking (perpendicular to the drift direction) and 2D fiducialization, and only used information from two CCD cameras when identifying tracks and rejecting backgrounds. Since that time, the collaboration has explored the potential benefits of photomultiplier tube and electronic charge readout to achieve 3D tracking, and particle identification for background rejection. The latest results of this effort is described here.
△ Less
Submitted 18 September, 2011; v1 submitted 15 September, 2011;
originally announced September 2011.
-
DMTPC: Dark matter detection with directional sensitivity
Authors:
J. B. R. Battat,
S. Ahlen,
T. Caldwell,
C. Deaconu,
D. Dujmic,
W. Fedus,
P. Fisher,
F. Golub,
S. Henderson,
A. Inglis,
A. Kaboth,
G. Kohse,
R. Lanza,
A. Lee,
J. Lopez,
J. Monroe,
T. Sahin,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
H. Wellenstein,
I. Wolfe,
R. Yamamoto,
H. Yegoryan
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) experiment uses CF_4 gas at low pressure (0.1 atm) to search for the directional signature of Galactic WIMP dark matter. We describe the DMTPC apparatus and summarize recent results from a 35.7 g-day exposure surface run at MIT. After nuclear recoil cuts are applied to the data, we find 105 candidate events in the energy range 80 - 200 keV, which is…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) experiment uses CF_4 gas at low pressure (0.1 atm) to search for the directional signature of Galactic WIMP dark matter. We describe the DMTPC apparatus and summarize recent results from a 35.7 g-day exposure surface run at MIT. After nuclear recoil cuts are applied to the data, we find 105 candidate events in the energy range 80 - 200 keV, which is consistent with the expected cosmogenic neutron background. Using this data, we obtain a limit on the spin-dependent WIMP-proton cross-section of 2.0 \times 10^{-33} cm^2 at a WIMP mass of 115 GeV/c^2. This detector is currently deployed underground at the Waste Isolation Pilot Plant in New Mexico.
△ Less
Submitted 17 December, 2010;
originally announced December 2010.
-
First Dark Matter Search Results from a Surface Run of the 10-L DMTPC Directional Dark Matter Detector
Authors:
S. Ahlen,
J. B. R. Battat,
T. Caldwell,
C. Deaconu,
D. Dujmic,
W. Fedus,
P. Fisher,
F. Golub,
S. Henderson,
A. Inglis,
A. Kaboth,
G. Kohse,
R. Lanza,
A. Lee,
J. Lopez,
J. Monroe,
T. Sahin,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
H. Wellenstein,
I. Wolfe,
R. Yamamoto,
H. Yegoryan
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr CF4) 10 liter detector capable of measuring the vector direction of nuclear recoils with the goal of directional dark matter detection. In this paper we present the first dark matter limit from DMTPC. In an analysis window of 80-200 keV recoil energy, based on a 35.7 g-day exposure, we set a 90% C.L. upper limit on the spin…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr CF4) 10 liter detector capable of measuring the vector direction of nuclear recoils with the goal of directional dark matter detection. In this paper we present the first dark matter limit from DMTPC. In an analysis window of 80-200 keV recoil energy, based on a 35.7 g-day exposure, we set a 90% C.L. upper limit on the spin-dependent WIMP-proton cross section of 2.0 x 10^{-33} cm^{2} for 115 GeV/c^2 dark matter particle mass.
△ Less
Submitted 9 December, 2010; v1 submitted 15 June, 2010;
originally announced June 2010.
-
The case for a directional dark matter detector and the status of current experimental efforts
Authors:
S. Ahlen,
N. Afshordi,
J. B. R. Battat,
J. Billard,
N. Bozorgnia,
S. Burgos,
T. Caldwell,
J. M. Carmona,
S. Cebrian,
P. Colas,
T. Dafni,
E. Daw,
D. Dujmic,
A. Dushkin,
W. Fedus,
E. Ferrer,
D. Finkbeiner,
P. H. Fisher,
J. Forbes,
T. Fusayasu,
J. Galan,
T. Gamble,
C. Ghag,
I. Giomataris,
M. Gold
, et al. (87 additional authors not shown)
Abstract:
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's stat…
▽ More
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.
△ Less
Submitted 1 November, 2009;
originally announced November 2009.
-
DMTPC: A dark matter detector with directional sensitivity
Authors:
J. B. R. Battat,
S. Ahlen,
T. Caldwell,
D. Dujmic,
A. Dushkin,
P. Fisher,
F. Golub,
S. Goyal,
S. Henderson,
A. Inglis,
R. Lanza,
J. Lopez,
A. Kaboth,
G. Kohse,
J. Monroe,
G. Sciolla,
B. N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
By correlating nuclear recoil directions with the Earth's direction of motion through the Galaxy, a directional dark matter detector can unambiguously detect Weakly Interacting Massive Particles (WIMPs), even in the presence of backgrounds. Here, we describe the Dark Matter Time-Projection Chamber (DMTPC) detector, a TPC filled with CF4 gas at low pressure (0.1 atm). Using this detector, we have…
▽ More
By correlating nuclear recoil directions with the Earth's direction of motion through the Galaxy, a directional dark matter detector can unambiguously detect Weakly Interacting Massive Particles (WIMPs), even in the presence of backgrounds. Here, we describe the Dark Matter Time-Projection Chamber (DMTPC) detector, a TPC filled with CF4 gas at low pressure (0.1 atm). Using this detector, we have measured the vector direction (head-tail) of nuclear recoils down to energies of 100 keV with an angular resolution of <15 degrees. To study our detector backgrounds, we have operated in a basement laboratory on the MIT campus for several months. We are currently building a new, high-radiopurity detector for deployment underground at the Waste Isolation Pilot Plant facility in New Mexico.
△ Less
Submitted 3 July, 2009;
originally announced July 2009.
-
A Background-Free Direction-Sensitive Neutron Detector2 A Background-Free Direction-Sensitive Neutron Detector
Authors:
Alvaro Roccaro,
H. Tomita,
S. Ahlen,
D. Avery,
A. Inglis,
J. Battat,
D. Dujmic,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Monroe,
G. Sciolla,
N. Skvorodnev,
H. Wellenstein,
R. Yamamoto
Abstract:
We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from x-rays and gamma rays, and most current neutron detectors lack single-event energy sensitivity or any information on neutron directionality. Even the best detector…
▽ More
We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from x-rays and gamma rays, and most current neutron detectors lack single-event energy sensitivity or any information on neutron directionality. Even the best detectors are limited by cosmic ray neutron backgrounds. All applications (neutron scattering and radiography, measurements of solar and cosmic ray neutron flux, measurements of neutron interaction cross sections, monitoring of neutrons at nuclear facilities, oil exploration, and searches for fissile weapons of mass destruction) will benefit from the improved neutron detection sensitivity and improved measurements of neutron properties made possible by this detector. The detector is free of backgrounds from x-rays, gamma rays, beta particles, relativistic singely charged particles and cosmic ray neutrons. It is sensitive to thermal neutrons, fission neutrons, and high energy neutrons, with detection features distinctive for each energy range. It is capable of determining the location of a source of fission neutrons based on characteristics of elastic scattering of neutrons by helium nuclei. The detector we have constructed could identify one gram of reactor grade plutonium, one meter away, with less than one minute of observation time.
△ Less
Submitted 21 June, 2009;
originally announced June 2009.
-
Transport properties of electrons in CF4
Authors:
T. Caldwell,
A. Roccaro,
T. Sahin,
H. Yegoryan,
D. Dujmic,
S. Ahlen,
J. Battat,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Lopez,
J. Monroe,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
Carbon-tetrafluoride (CF4) is used as a counting gas in particle detectors, but some of its properties that are of interest for large time-projection chambers are not well known. We measure the mean energy, which is proportional to the diffusion coefficent, and the attentuation coefficient of electron propagation in CF4 gas using a 10-liter dark matter detector prototype of the DMTPC project.
Carbon-tetrafluoride (CF4) is used as a counting gas in particle detectors, but some of its properties that are of interest for large time-projection chambers are not well known. We measure the mean energy, which is proportional to the diffusion coefficent, and the attentuation coefficient of electron propagation in CF4 gas using a 10-liter dark matter detector prototype of the DMTPC project.
△ Less
Submitted 15 May, 2009;
originally announced May 2009.
-
The DMTPC project
Authors:
G. Sciolla,
J. Battat,
T. Caldwell,
D. Dujmic,
P. Fisher,
S. Henderson,
R. Lanza,
A. Lee,
J. Lopez,
A. Kaboth,
G. Kohse,
J. Monroe,
T. Sahin,
G. Sciolla,
R. Yamamoto,
H. Yegoryan,
S. Ahlen,
K. Otis,
H. Tomita,
A. Dushkin,
H. Wellenstein
Abstract:
The DMTPC detector is a low-pressure CF4 TPC with optical readout for directional detection of Dark Matter. The combination of the energy and directional tracking information allows for an efficient suppression of all backgrounds. The choice of gas (CF4) makes this detector particularly sensitive to spin-dependent interactions.
The DMTPC detector is a low-pressure CF4 TPC with optical readout for directional detection of Dark Matter. The combination of the energy and directional tracking information allows for an efficient suppression of all backgrounds. The choice of gas (CF4) makes this detector particularly sensitive to spin-dependent interactions.
△ Less
Submitted 23 March, 2009;
originally announced March 2009.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.
-
The DMTPC detector
Authors:
G. Sciolla,
J. Battat,
T. Caldwell,
B. Cornell,
D. Dujmic,
P. Fisher,
S. Henderson,
R. Lanza,
A. Lee,
J. Lopez,
A. Kaboth,
G. Kohse,
J. Monroe,
T. Sahin,
R. Vanderspek,
R. Yamamoto,
H. Yegoryan,
S. Ahlen,
D. Avery,
K. Otis,
A. Roccaro,
H. Tomita,
A. Dushkin,
H. Wellenstein
Abstract:
Directional detection of Dark Matter allows for unambiguous direct detection of WIMPs as well as discrimination between various Dark Matter models in our galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed for directional direct detection of WIMPs. By using CF4 gas as the active material, the detector also has excellent sensitivity to spin-dependent interactions of Dar…
▽ More
Directional detection of Dark Matter allows for unambiguous direct detection of WIMPs as well as discrimination between various Dark Matter models in our galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed for directional direct detection of WIMPs. By using CF4 gas as the active material, the detector also has excellent sensitivity to spin-dependent interactions of Dark Matter on protons.
△ Less
Submitted 18 November, 2008;
originally announced November 2008.
-
DMTPC-10L: Direction-Sensitive Dark Matter Detector Prototype
Authors:
D. Dujmic,
P. Fisher,
R. Lanza,
J. Lopez,
A. Kaboth,
G. Kohse,
J. Monroe,
R. Vanderspek,
G. Sciolla,
R. Yamamoto,
S. Ahlen,
K. Otis,
A. Roccaro,
H. Tomita,
N. Skvorodnev,
H. Wellenstein
Abstract:
The known direction of motion of dark matter particles relative to the Earth may be a key for their unambiguous identification even in the presence of backgrounds. We describe a prototype detector that is able to reconstruct direction vectors of weakly interacting massive particles that may the dominant constituent of the dark matter in our galaxy. The detector uses a low-density gas (CF4) in a…
▽ More
The known direction of motion of dark matter particles relative to the Earth may be a key for their unambiguous identification even in the presence of backgrounds. We describe a prototype detector that is able to reconstruct direction vectors of weakly interacting massive particles that may the dominant constituent of the dark matter in our galaxy. The detector uses a low-density gas (CF4) in a 10liter time-projection chamber with mesh-based electrodes and optical and charge readout. Initial results confirm good performance in the reconstruction of direction angle and sense ('head-tail') for low-momentum nuclear recoils.
△ Less
Submitted 15 October, 2008;
originally announced October 2008.
-
DMTPC: a new apparatus for directional detection of Dark Matter
Authors:
G. Sciolla,
A. Lee,
J. Battat,
T. Caldwell,
B. Cornell,
D. Dujmic,
P. Fisher,
S. Henderson,
R. Lanza,
J. Lopez,
A. Kaboth,
G. Kohse,
J. Monroe,
T. Sahin,
R . Vanderspek,
R. Yamamoto,
H. Yegoryan,
S. Alhen,
D. Avery,
K. Otis,
A. Roccaro,
H. Tomita,
A. Dushkin,
H. Wellenstein
Abstract:
Directional detection of Dark Matter allows for unambiguous direct detection of WIMPs as well as discrimination between various Dark Matter models in our galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed for directional direct detection of WIMPs. By using CF4 gas as the active material, the detector also has excellent sensitivity to spin-dependent interactions of Dar…
▽ More
Directional detection of Dark Matter allows for unambiguous direct detection of WIMPs as well as discrimination between various Dark Matter models in our galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed for directional direct detection of WIMPs. By using CF4 gas as the active material, the detector also has excellent sensitivity to spin-dependent interactions of Dark Matter on protons.
△ Less
Submitted 1 October, 2008;
originally announced October 2008.
-
Toward directional detection of Dark Matter with the DM-TPC detector
Authors:
G. Sciolla,
S. Ahlen,
D. Dujmic,
V. Dutta,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Monroe,
A. Roccaro,
N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
Directional detection can provide unambiguous observation of Dark Matter interactions even in presence of insidious backgrounds. The DM-TPC collaboration is developing a detector with the goal of measuring the direction and sense of nuclear recoils produced in Dark Matter interactions. The detector consists of a Time Projection Chamber with optical readout filled with CF$_4$ gas at low pressure.…
▽ More
Directional detection can provide unambiguous observation of Dark Matter interactions even in presence of insidious backgrounds. The DM-TPC collaboration is developing a detector with the goal of measuring the direction and sense of nuclear recoils produced in Dark Matter interactions. The detector consists of a Time Projection Chamber with optical readout filled with CF$_4$ gas at low pressure. A collision between a WIMP and a gas molecule results in a nuclear recoil of 1-2 mm. The measurement of the energy loss along the recoil allows us to determine the sense and the direction of the recoil. Results from a prototype detector operated in a low-energy neutron beam clearly demonstrate the suitability of this approach to measure directionality. A cubic meter prototype, which is now being designed, will allow us to set competitive limits on spin-dependent Dark Matter interactions using a directional detector.
△ Less
Submitted 16 June, 2008;
originally announced June 2008.
-
DM-TPC: a new approach to directional detection of Dark Matter
Authors:
G. Sciolla,
S. Ahlen,
D. Dujmic,
V. Dutta,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Monroe,
A. Roccaro,
N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
Directional detection can provide unambiguous observation of Dark Matter interactions even in presence of insidious backgrounds. The DM-TPC collaboration is developing a detector with the goal of measuring the direction and sense of nuclear recoils produced in Dark Matter interactions. The detector consists of a Time Projection Chamber with optical readout filled with CF$_4$ gas at low pressure.…
▽ More
Directional detection can provide unambiguous observation of Dark Matter interactions even in presence of insidious backgrounds. The DM-TPC collaboration is developing a detector with the goal of measuring the direction and sense of nuclear recoils produced in Dark Matter interactions. The detector consists of a Time Projection Chamber with optical readout filled with CF$_4$ gas at low pressure. A collision between a WIMP and a gas molecule results in a nuclear recoil of 1-2 mm. The measurement of the energy loss along the recoil allows us to determine the sense and the direction of the recoil.
Results from a prototype detector operated in a low-energy neutron beam clearly demonstrate the suitability of this approach to measure directionality. A full-scale module with an active volume of about one cubic meter is now being designed. This detector, which will be operated underground in 2009, will allow us to set competitive limits on spin-dependent Dark Matter interactions using a directional detector.
△ Less
Submitted 15 May, 2008;
originally announced May 2008.
-
Charge amplification concepts for direction-sensitive dark matter detectors
Authors:
D. Dujmic,
P. Fisher,
G. Sciolla,
S. Ahlen,
V. Dutta,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Monroe,
A. Roccaro,
N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
Direction measurement of weakly interacting massive particles in time-projection chambers can provide definite evidence of their existence and help to determine their properties. This article demonstrates several concepts for charge amplification in time-projection chambers that can be used in direction-sensitive dark matter search experiments. We demonstrate reconstruction of the 'head-tail' ef…
▽ More
Direction measurement of weakly interacting massive particles in time-projection chambers can provide definite evidence of their existence and help to determine their properties. This article demonstrates several concepts for charge amplification in time-projection chambers that can be used in direction-sensitive dark matter search experiments. We demonstrate reconstruction of the 'head-tail' effect for nuclear recoils above 100keV, and discuss the detector performance in the context of dark matter detection and scaling to large detector volumes.
△ Less
Submitted 22 August, 2008; v1 submitted 30 April, 2008;
originally announced April 2008.
-
A Measurement of Photon Production in Electron Avalanches in CF4
Authors:
A. Kaboth,
J. Monroe,
S. Ahlen,
D. Dujmic,
S. Henderson,
G. Kohse,
R. Lanza,
M. Lewandowska,
A. Roccaro,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto,
P. Fisher
Abstract:
This paper presents a measurement of the ratio of photon to electron production and the scintillation spectrum in a popular gas for time pro jection chambers, carbon tetrafluoride (CF4), over the range of 200 to 800 nm; the ratio is measured to be 0.34+/-0.04. This result is of particular importance for a new generation of dark matter time projection chambers with directional sensitivity which u…
▽ More
This paper presents a measurement of the ratio of photon to electron production and the scintillation spectrum in a popular gas for time pro jection chambers, carbon tetrafluoride (CF4), over the range of 200 to 800 nm; the ratio is measured to be 0.34+/-0.04. This result is of particular importance for a new generation of dark matter time projection chambers with directional sensitivity which use CF4 as a fill gas.
△ Less
Submitted 14 March, 2008;
originally announced March 2008.
-
Improved measurement of the head-tail effect in nuclear recoils
Authors:
D. Dujmic,
S. Ahlen,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
M. Lewandowska,
J. Monroe,
A. Roccaro,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
We present new results with a prototype detector that is being developed by the DMTPC collaboration for the measurement of the direction tag (head-tail) of dark matter wind. We use neutrons from a Cf-252 source to create low-momentum nuclear recoils in elastic scattering with the residual gas nuclei. The recoil track is imaged in low-pressure time-projection chamber with optical readout. We meas…
▽ More
We present new results with a prototype detector that is being developed by the DMTPC collaboration for the measurement of the direction tag (head-tail) of dark matter wind. We use neutrons from a Cf-252 source to create low-momentum nuclear recoils in elastic scattering with the residual gas nuclei. The recoil track is imaged in low-pressure time-projection chamber with optical readout. We measure the ionization rate along the recoil trajectory, which allows us to determine the direction tag of the incoming neutrons.
△ Less
Submitted 17 January, 2008;
originally announced January 2008.
-
Observation of the 'head-tail' effect in nuclear recoils of low-energy neutrons
Authors:
D. Dujmic,
H. Tomita,
M. Lewandowska,
S. Ahlen,
P. Fisher,
S. Henderson,
A. Kaboth,
G. Kohse,
R. Lanza,
J. Monroe,
A. Roccaro,
G. Sciolla,
N. Skvorodnev,
R. Vanderspek,
H. Wellenstein,
R. Yamamoto
Abstract:
Directional detection of dark matter can provide unambiguous observation of dark matter interactions even in the presence of background. This article presents an experimental method to measure the direction tag ("head-tail") of the dark matter wind by detecting the scintillation light created by the elastic nuclear recoils in the scattering of dark matter particles with the detector material. Th…
▽ More
Directional detection of dark matter can provide unambiguous observation of dark matter interactions even in the presence of background. This article presents an experimental method to measure the direction tag ("head-tail") of the dark matter wind by detecting the scintillation light created by the elastic nuclear recoils in the scattering of dark matter particles with the detector material. The technique is demonstrated by tagging the direction of the nuclear recoils created in the scattering of low-energy neutrons with CF4 in a low-pressure time-projection chamber that is developed by the DMTPC collaboration. The measurement of the decreasing ionization rate along the recoil trajectory provides the direction tag of the incoming neutrons, and proves that the "head-tail" effect can be observed.
△ Less
Submitted 9 October, 2007; v1 submitted 17 August, 2007;
originally announced August 2007.