-
Search for light dark matter with NEWS-G at the LSM using a methane target
Authors:
M. M. Arora,
L. Balogh,
C. Beaufort,
A. Brossard,
M. Chapellier,
J. Clarke,
E. C. Corcoran,
J. -M. Coquillat,
A. Dastgheibi-Fard,
Y. Deng,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly,
P. Knights,
P. Lautridou,
A. Makowski
, et al. (18 additional authors not shown)
Abstract:
The NEWS-G direct detection experiment uses spherical proportional counters to search for light dark matter candidates. New results from a 10 day physics run with a $135\,\mathrm{cm}$ in diameter spherical proportional counter at the Laboratoire Souterrain de Modane are reported. The target consists of $114\,\mathrm{g}$ of methane, providing sensitivity to dark matter spin-dependent coupling to pr…
▽ More
The NEWS-G direct detection experiment uses spherical proportional counters to search for light dark matter candidates. New results from a 10 day physics run with a $135\,\mathrm{cm}$ in diameter spherical proportional counter at the Laboratoire Souterrain de Modane are reported. The target consists of $114\,\mathrm{g}$ of methane, providing sensitivity to dark matter spin-dependent coupling to protons. New constraints are presented in the mass range $0.17$ to $1.2\,\mathrm{GeV/c^2}$, with a 90% confidence level cross-section upper limit of $30.9\,\mathrm{pb}$ for a mass of $0.76\,\mathrm{GeV/c^2}$.
△ Less
Submitted 17 July, 2024;
originally announced July 2024.
-
Directional detection of keV proton and carbon recoils with MIMAC
Authors:
C. Beaufort,
O. Guillaudin,
D. Santos,
N. Sauzet,
E. Mobio,
R. Babut,
C. Tao
Abstract:
Directional detection is the dedicated strategy to demonstrate that DM-like signals measured by direct detectors are indeed produced by DM particles from the galactic halo. The experimental challenge of measuring the direction of DM-induced nuclear recoils with (sub-)millimeter tracks has limited, so far, the maximal directional reach to DM masses around $100~\rm{GeV}$. In this paper, we expose th…
▽ More
Directional detection is the dedicated strategy to demonstrate that DM-like signals measured by direct detectors are indeed produced by DM particles from the galactic halo. The experimental challenge of measuring the direction of DM-induced nuclear recoils with (sub-)millimeter tracks has limited, so far, the maximal directional reach to DM masses around $100~\rm{GeV}$. In this paper, we expose the MIMAC detector to three different neutron fields and we develop a method to reconstruct the direction of the neutron-induced nuclear recoils. We measure an angular resolution better than $16^\circ$ for proton recoils down to a kinetic energy of $4~\rm{keV}$ and for carbon recoils down to a kinetic energy of $5.5~\rm{keV}$. For the first time, a detector achieves the directional measurement of proton and carbon recoils with kinetic energies in the keV range without any restriction on the direction of the incoming particle. This work demonstrates that directional detection is around the corner for probing DM with masses down to $\mathcal{O}(1~\rm{GeV})$.
△ Less
Submitted 27 March, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
Directional detection of meV dark photons with Dandelion
Authors:
C. Beaufort,
M. Bastero-Gil,
A. Catalano,
D-S. Erfani-Harami,
O. Guillaudin,
D. Santos,
S. Savorgnano,
F. Vezzu
Abstract:
This paper presents Dandelion, a new dish antenna experiment searching for dark photons (DPs) with masses around the meV that will start acquiring data by the end of 2023. A spherical mirror acts as a conversion surface between DPs and standard photons that converge to a matrix of 418 Kinetic Inductance Detectors cooled down to 150 mK. A tilt of the mirror at 1 Hz moves the expected signal over th…
▽ More
This paper presents Dandelion, a new dish antenna experiment searching for dark photons (DPs) with masses around the meV that will start acquiring data by the end of 2023. A spherical mirror acts as a conversion surface between DPs and standard photons that converge to a matrix of 418 Kinetic Inductance Detectors cooled down to 150 mK. A tilt of the mirror at 1 Hz moves the expected signal over the pixels thus enabling a continuous background measurement. The expected signal has two modulations: a spatial modulation providing a directional signature for the unambiguous discovery of a DP, and an intensity modulation allowing the determination of the polarization of the DP. For masses near the meV, the inflationary production of longitudinal and transverse DPs are mutually excluded, thus the polarization determination by Dandelion could shed a new light on the inflation phase of the early universe. A first Dandelion prototype operating for 30 days would improve by more than one order of magnitude the current exclusion limits on DPs at the meV mass scale and would probe this region with an unprecedented discovery potential based on directional detection.
△ Less
Submitted 25 October, 2023;
originally announced October 2023.
-
Coherent elastic neutrino-nucleus scattering: Terrestrial and astrophysical applications
Authors:
M. Abdullah,
H. Abele,
D. Akimov,
G. Angloher,
D. Aristizabal-Sierra,
C. Augier,
A. B. Balantekin,
L. Balogh,
P. S. Barbeau,
L. Baudis,
A. L. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
A. Bento,
L. Berge,
I. A. Bernardi,
J. Billard,
A. Bolozdynya,
A. Bonhomme,
G. Bres,
J-. L. Bret,
A. Broniatowski,
A. Brossard,
C. Buck
, et al. (250 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion source with CsI detectors, followed up the detection of CE$ν$NS using an Ar target. The detection of CE$ν$NS has spawned a flurry of activities in high-energy physics, inspiring new constraints on beyond the Standard Model (BSM) physics, and new experimental methods. The CE$ν$NS process has important implications for not only high-energy physics, but also astrophysics, nuclear physics, and beyond. This whitepaper discusses the scientific importance of CE$ν$NS, highlighting how present experiments such as COHERENT are informing theory, and also how future experiments will provide a wealth of information across the aforementioned fields of physics.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Solar Kaluza-Klein axion search with NEWS-G
Authors:
NEWS-G collaboration,
:,
Q. Arnaud,
L. Balogh,
C. Beaufort,
A. Brossard,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi-Fard,
Y. Deng,
K. Dering,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas
, et al. (18 additional authors not shown)
Abstract:
Kaluza-Klein (KK) axions appear in theories with extra dimensions as higher mass, significantly shorter lifetime, excitations of the Peccei-Quinn axion. When produced in the Sun, they would remain gravitationally trapped in the solar system, and their decay to a pair of photons could provide an explanation of the solar corona heating problem. A low-density detector would discriminate such a signal…
▽ More
Kaluza-Klein (KK) axions appear in theories with extra dimensions as higher mass, significantly shorter lifetime, excitations of the Peccei-Quinn axion. When produced in the Sun, they would remain gravitationally trapped in the solar system, and their decay to a pair of photons could provide an explanation of the solar corona heating problem. A low-density detector would discriminate such a signal from the background, by identifying the separation of the interaction point of the two photons. The NEWS-G collaboration uses large volume Spherical Proportional Counters, gas-filled metallic spheres with a spherical anode in their centre. After observation of a single axionlike event in a 42 day long run with the SEDINE detector, a $90\%$ C.L. upper limit of $g_{aγγ}<8.99\cdot10^{-13}\,GeV^{-1}$ is set on the axion-photon coupling for a KK axion density on Earth of $n_{a}=4.07\cdot10^{13}\,m^{-3}$ and two extra dimensions of size $R = 1\,eV^{-1}$.
△ Less
Submitted 9 January, 2022; v1 submitted 8 September, 2021;
originally announced September 2021.
-
Copper electroplating for background suppression in the NEWS-G experiment
Authors:
NEWS-G Collaboration,
:,
L. Balogh,
C. Beaufort,
A. Brossard,
R. Bunker,
J. -F. Caron,
M. Chapellier,
J. -M. Coquillat,
E. C. Corcoran,
S. Crawford,
A. Dastgheibi Fard,
Y. Deng,
K. Dering,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly
, et al. (26 additional authors not shown)
Abstract:
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper.…
▽ More
New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$μ$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $μ$Bq/kg (<0.24 $μ$Bq/kg) and <0.26 $μ$Bq/kg (<0.11 $μ$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.
△ Less
Submitted 13 December, 2020; v1 submitted 7 August, 2020;
originally announced August 2020.
-
Track length measurement of $^{19}$F$^+$ ions with the MIMAC Dark Matter directional detector prototype
Authors:
Y. Tao,
C. Beaufort,
I. Moric,
C. Tao,
D. Santos,
N. Sauzet,
C. Couturier,
O. Guillaudin,
J. F. Muraz,
F. Naraghi,
N. Zhou,
J. Busto
Abstract:
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred candidate for Dark Matter. WIMPs should interact with the nuclei of detectors. If a robust signal is eventually observed in direct detection experiments, the best signature to confirm its Galactic origin would be the nuclear recoil track direction. The MIMAC collaboration has developed a low pressure gas detector providing…
▽ More
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred candidate for Dark Matter. WIMPs should interact with the nuclei of detectors. If a robust signal is eventually observed in direct detection experiments, the best signature to confirm its Galactic origin would be the nuclear recoil track direction. The MIMAC collaboration has developed a low pressure gas detector providing both the kinetic energy and three-dimensional track reconstruction of nuclear recoils. In this paper we report the first ever observations of $^{19}$F nuclei tracks in a $5$ cm drift prototype MIMAC detector, in the low kinetic energy range ($6$-$26$ keV), using specially developed ion beam facilities. We have measured the recoil track lengths and found significant differences between our measurements and standard simulations. In order to understand these differences, we have performed a series of complementary experiments and simulations to study the impact of the diffusion and eventual systematics. We show an unexpected dependence of the number of read-out corresponding to the track on the electric field applied to the $512\ \mathrm{μm}$ gap of the Micromegas detector. We have introduced, based on the flash-ADC observable, corrections in order to reconstruct the physical 3D track length of the primary electron clouds proposing the physics behind these corrections. We show that diffusion and space charge effects need to be taken into account to explain the differences between measurements and standard simulations. These measurements and simulations may shed a new light on the high-gain TPC ionization signals in general and particularly at low energy.
△ Less
Submitted 26 March, 2020; v1 submitted 5 March, 2019;
originally announced March 2019.
-
Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment
Authors:
NEWS-G Collaboration,
:,
Q. Arnaud,
J. -P. Bard,
A. Brossard,
M. Chapellier,
M. Clark,
S. Crawford,
E. C. Corcoran,
A. Dastgheibi-Fard,
K. Dering,
P. Di Stefano,
D. Durnford,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
A. Kamaha,
I. Katsioulas,
D. G. Kelly,
P. Knights
, et al. (15 additional authors not shown)
Abstract:
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and ana…
▽ More
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.
△ Less
Submitted 24 February, 2019;
originally announced February 2019.
-
Cathode signal in a TPC directional detector: implementation and validation measuring the drift velocity
Authors:
C. Couturier,
Q. Riffard,
N. Sauzet,
O. Guillaudin,
F. Naraghi,
D. Santos
Abstract:
Low-pressure gaseous TPCs are well suited detectors to correlate the directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in addition to providing a measure of the energy deposition due to the elastic scattering of a DM particle on a nucleus in the target gas, they allow for the reconstruction of the track of the recoiling nucleus. In order to exclude the background events…
▽ More
Low-pressure gaseous TPCs are well suited detectors to correlate the directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in addition to providing a measure of the energy deposition due to the elastic scattering of a DM particle on a nucleus in the target gas, they allow for the reconstruction of the track of the recoiling nucleus. In order to exclude the background events originating from radioactive decays on the surfaces of the detector materials within the drift volume, efforts are ongoing to precisely localize the track nuclear recoil in the drift volume along the axis perpendicular to the cathode plane. We report here the implementation of the measure of the signal induced on the cathode by the motion of the primary electrons toward the anode in a MIMAC chamber. As a validation, we performed an independent measurement of the drift velocity of the electrons in the considered gas mixture, correlating in time the cathode signal with the measure of the arrival times of the electrons on the anode.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
First results from the NEWS-G direct dark matter search experiment at the LSM
Authors:
NEWS-G Collaboration,
:,
Q. Arnaud,
D. Asner,
J. -P. Bard,
A. Brossard,
B. Cai,
M. Chapellier,
M. Clark,
E. C. Corcoran,
T. Dandl,
A. Dastgheibi-Fard,
K. Dering,
P. Di Stefano,
D. Durnford,
G. Gerbier,
I. Giomataris,
P. Gorel,
M. Gros,
O. Guillaudin,
E. W. Hoppe,
A. Kamaha,
I. Katsioulas,
D. G. Kelly,
R. D. Martin
, et al. (12 additional authors not shown)
Abstract:
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection experiment using Spherical Proportional Counters (SPCs) with light noble gases to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report the results from the first physics run taken at the Laboratoire Souterrain de Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a mixture of…
▽ More
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection experiment using Spherical Proportional Counters (SPCs) with light noble gases to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report the results from the first physics run taken at the Laboratoire Souterrain de Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the spin-independent WIMP-nucleon scattering cross-section in the sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times \mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5 $\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to be installed at SNOLAB by summer 2018.
△ Less
Submitted 7 September, 2017; v1 submitted 15 June, 2017;
originally announced June 2017.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
Directional detection of Dark Matter with the MIcro-tpc MAtrix of Chambers
Authors:
C. Couturier,
O. Guillaudin,
F. Naraghi,
Q. Riffard,
D. Santos,
N. Sauzet,
P. Colas,
E. Ferrer Ribas,
I. Giomataris,
J. Busto,
D. Fouchez,
C. Tao,
N. Zhou
Abstract:
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chamb…
▽ More
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed an original prototype detector which combines a large pixelated Micromegas coupled with a fast, self-triggering, electronics. Aspects of the two-chamber module in operation in the Modane Underground Laboratory are presented: calibration, characterization of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the COMIMAC portable quenching line has been set up to characterize the 3D tracks of low energy ions in the MIMAC gas mixture: the preliminary results thereof are presented. Future steps are briefly discussed.
△ Less
Submitted 29 July, 2016;
originally announced July 2016.
-
MIMAC low energy electron-recoil discrimination measured with fast neutrons
Authors:
Q. Riffard,
D. Santos,
O. Guillaudin,
G. Bosson,
O. Bourrion,
J. Bouvier,
T. Descombes,
J. -F. Muraz,
L. Lebreton,
D. Maire,
P. Colas,
I. Giomataris,
J. Busto,
D. Fouchez,
J. Brunner,
C. Tao
Abstract:
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using m…
▽ More
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic scattering. In this paper, we proposed an original method for electron event rejection based on a multivariate analysis applied to experimental data acquired using monochromatic neutron fields. This analysis shows that a $10^5$ rejection power is reachable for electron/recoil discrimination. Moreover, the efficiency was estimated by a Monte-Carlo simulation showing that a 105 electron rejection power is reached with a $86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range and $94.67\pm0.19$\% considering a 5~keV lower threshold.
△ Less
Submitted 4 July, 2016; v1 submitted 4 February, 2016;
originally announced February 2016.
-
First detection of tracks of radon progeny recoils by MIMAC
Authors:
Q. Riffard,
D. Santos,
G. Bosson,
O. Bourrion,
T. Descombes,
C. Fourel,
O. Guillaudin,
J. -F. Muraz,
P. Colas,
E. Ferrer-Ribas,
I. Giomataris,
J. Busto,
D. Fouchez,
C. Tao,
L. Lebreton,
D. Maire
Abstract:
The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since…
▽ More
The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the Modane underground laboratory. In this paper, we report the first ionization energy and 3D track observations of nuclear recoils produced by the radon progeny. This measurement shows the capability of the MIMAC detector and opens the possibility to explore the low energy recoil directionality signature.
△ Less
Submitted 20 June, 2017; v1 submitted 22 April, 2015;
originally announced April 2015.
-
Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Chabot,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon
, et al. (9 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of c…
▽ More
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of cosmic ray impacts on the HFI detector modules has been undertaken to categorize and characterize the glitches, to correct the HFI time-ordered data, and understand the residual effects on Planck maps and data products. This paper presents an evaluation of the physical origins of glitches observed by the HFI detectors. In order to better understand the glitches observed by HFI in flight, several ground-based experiments were conducted with flight-spare HFI bolometer modules. The experiments were conducted between 2010 and 2013 with HFI test bolometers in different configurations using varying particles and impact energies. The bolometer modules were exposed to 23 MeV protons from the Orsay IPN TANDEM accelerator, and to $^{241}$Am and $^{244}$Cm $α$-particle and $^{55}$Fe radioactive X-ray sources. The calibration data from the HFI ground-based preflight tests were used to further characterize the glitches and compare glitch rates with statistical expectations under laboratory conditions. Test results provide strong evidence that the dominant family of glitches observed in flight are due to cosmic ray absorption by the silicon die substrate on which the HFI detectors reside. Glitch energy is propagated to the thermistor by ballistic phonons, while there is also a thermal diffusion contribution. The implications of these results for future satellite missions, especially those in the far-infrared to sub-millimetre and millimetre regions of the electromagnetic spectrum, are discussed.
△ Less
Submitted 2 September, 2014; v1 submitted 26 March, 2014;
originally announced March 2014.
-
Characterization and Physical Explanation of Energetic Particles on Planck HFI Instrument
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon,
A. Pelissier
, et al. (8 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and…
▽ More
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft. Protons with an energy above 40MeV can penetrate the focal plane unit box causing two different effects: glitches in the raw data from direct interaction of cosmic rays with detectors (producing a data loss of about 15% at the end of the mission) and thermal drifts in the bolometer plate at 100mK adding non-gaussian noise at frequencies below 0.1Hz. The HFI consortium has made strong efforts in order to correct for this effect on the time ordered data and final Planck maps. This work intends to give a view of the physical explanation of the glitches observed in the HFI instrument in-flight. To reach this goal, we performed several ground-based experiments using protons and $α$ particles to test the impact of particles on the HFI spare bolometers with a better control of the environmental conditions with respect to the in-flight data. We have shown that the dominant part of glitches observed in the data comes from the impact of cosmic rays in the silicon die frame supporting the micro-machinced bolometric detectors propagating energy mainly by ballistic phonons and by thermal diffusion. The implications of these results for future satellite missions will be discussed.
△ Less
Submitted 22 March, 2014;
originally announced March 2014.
-
Measurement of the electron drift velocity for directional dark matter detectors
Authors:
F. Mayet,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
J. P. Richer,
Q. Riffard,
D. Santos,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by sim…
▽ More
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the electron drift velocity while keeping almost the same Fluorine content of the gas mixture.
△ Less
Submitted 6 January, 2014;
originally announced January 2014.
-
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection
Authors:
D. Santos,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
O. Guillaudin,
J. Lamblin,
F. Mayet,
J. F. Muraz,
J. P. Richer,
Q. Riffard,
L. Lebreton,
D. Maire,
J. Busto,
J. Brunner,
D. Fouchez
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last ye…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a special developed fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The first bi-chamber prototype has been installed at Modane, underground laboratory in June 2012. The first undergournd background events, the gain stability and calibration are shown. The first spectrum of nuclear recoils showing 3D tracks coming from the radon progeny is presented.
△ Less
Submitted 4 November, 2013;
originally announced November 2013.
-
Dark Matter directional detection with MIMAC
Authors:
Q. Riffard,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
F. Mayet,
J. -F. Muraz,
J. -P. Richer,
D. Santos,
L. Lebreton,
D. Maire,
J. Busto,
J. Brunner,
D. Fouchez
Abstract:
Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters.
The MIMAC project, based on a \textmu-TPC matrix, with…
▽ More
Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a measurement of the recoil energy with a threshold of about 5 keV and 3D recoil tracks down to few millimeters.
The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is being developed. In June 2012, a bi-chamber prototype was installed at the LSM (Laboratoire Souterrain de Modane). A preliminary analysis of the first four months data taking allowed, for the first time, the observation of recoils from the $\mathrm{^{222}Rn}$ progeny.
△ Less
Submitted 18 June, 2013;
originally announced June 2013.
-
In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors
Authors:
J. Billard,
F. Mayet,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
J. P. Richer,
Q. Riffard,
D. Santos,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by…
▽ More
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence needed as it is a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3. The latter has been chosen for the MIMAC detector as we expect that adding CHF3 to pure CF4 will lower the electron drift velocity. This is a key point for directional Dark Matter as the track sampling along the drift field will be improved while keeping almost the same Fluorine content of the gas mixture. We show that the drift velocity at 50 mbar is reduced by a factor of about 5 when adding 30% of CHF3.
△ Less
Submitted 28 January, 2014; v1 submitted 10 May, 2013;
originally announced May 2013.
-
MIMAC: A micro-tpc matrix for dark matter directional detection
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
C. Fourel,
O. Guillaudin,
J. Lamblin,
J. F. Muraz,
F. Mayet,
J. P. Richer,
Q. Riffard,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based o…
▽ More
The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.
△ Less
Submitted 8 April, 2013;
originally announced April 2013.
-
MIMAC: A micro-tpc matrix project for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
O. Guillaudin,
F. Mayet,
J. P. Richer,
A. Delbart,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of…
▽ More
Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of this matrix, on low energy nuclear recoils (1H and 19F) obtained with mono-energetic neutron fields are presented. The discovery potential of this search strategy is illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 7 November, 2011;
originally announced November 2011.
-
Development and validation of a 64 channel front end ASIC for 3D directional detection for MIMAC
Authors:
J. P. Richer,
O. Bourrion,
G. Bosson,
O. Guillaudin,
F. Mayet,
D. Santos
Abstract:
A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the "Time Over Threshold" information for each of those. These 64 digital informations, sampled at a rate of 50…
▽ More
A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the "Time Over Threshold" information for each of those. These 64 digital informations, sampled at a rate of 50 MHz, can be transferred at 400MHz by eight LVDS serial links. Eight ASIC were validated on a 2x256 strips of pixels prototype.
△ Less
Submitted 10 November, 2011; v1 submitted 20 October, 2011;
originally announced October 2011.
-
Data acquisition electronics and reconstruction software for real time 3D track reconstruction within the MIMAC project
Authors:
O. Bourrion,
G. Bosson,
C. Grignon,
J. L. Bouly,
J. P. Richer,
O. Guillaudin,
F. Mayet,
J. Billard,
D. Santos
Abstract:
Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses em…
▽ More
Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.
△ Less
Submitted 2 November, 2011; v1 submitted 19 October, 2011;
originally announced October 2011.
-
Dedicated front-end and readout electronics developments for real time 3D directional detection of dark matter with MIMAC
Authors:
O. Bourrion,
G. Bosson,
C. Grignon,
J. P. Richer,
O. Guillaudin,
F. Mayet,
J. Billard,
D. Santos
Abstract:
A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been designed. An associated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This auto-tri…
▽ More
A complete dedicated electronics, from front-end to back-end, was developed to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of pixels and to provide their individual "Time Over Threshold" information has been designed. An associated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This auto-triggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. The electronic designs, acquisition software and the results obtained are presented.
△ Less
Submitted 19 September, 2011; v1 submitted 9 September, 2011;
originally announced September 2011.
-
Micromegas detector developments for MIMAC
Authors:
E. Ferrer-Ribas,
D. Attié,
D. Calvet,
P. Colas,
F. Druillole,
Y. Giomataris,
F. J. Iguaz,
J. P. Mols,
J. Pancin,
T. Papaevangelou,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
D. Santos,
C. Golabek,
L. Lebreton
Abstract:
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
△ Less
Submitted 12 September, 2011; v1 submitted 8 September, 2011;
originally announced September 2011.
-
MIMAC : A micro-tpc matrix for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
A. Delbart,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. T…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 16 February, 2011;
originally announced February 2011.
-
MIMAC : A micro-tpc matrix for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
A. Allaoua,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H and 19F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 6 December, 2010;
originally announced December 2010.
-
Directional detection of non-baryonic dark matter with MIMAC
Authors:
C. Grignon,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
F. Mayet,
J. P. Richer,
D. Santos,
E. Ferrer,
I. Giomataris,
J. P. Mols
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix,…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low energy nuclei recoils obtained with a low energy neutron field are presented.
△ Less
Submitted 17 September, 2010; v1 submitted 27 August, 2010;
originally announced August 2010.
-
Data acquisition electronics and reconstruction software for directional detection of Dark Matter with MIMAC
Authors:
O. Bourrion,
G. Bosson,
C. Grignon,
J. L. Bouly,
J. P. Richer,
O. Guillaudin,
F. Mayet,
D. Santos
Abstract:
Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its usef…
▽ More
Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.
△ Less
Submitted 7 June, 2010;
originally announced June 2010.
-
Directional detection of Dark Matter
Authors:
J. Billard,
F. Mayet,
J. F. Macias-Perez,
D. Santos,
C. Grignon,
O. Guillaudin
Abstract:
Directional detection of galactic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, to take full advantage of this powerful detection method, one need to be able to extract information from an observed recoil map to identify a WIMP signal. We present a comprehensive formalism, using a map-based likelihood method allowing to recover t…
▽ More
Directional detection of galactic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, to take full advantage of this powerful detection method, one need to be able to extract information from an observed recoil map to identify a WIMP signal. We present a comprehensive formalism, using a map-based likelihood method allowing to recover the main incoming direction of the signal, thus proving its galactic origin, and the corresponding significance. Constraints are then deduced in the (sigma_n, m_chi) plane.
△ Less
Submitted 14 April, 2010;
originally announced April 2010.
-
Directional detection of galactic Dark Matter
Authors:
F. Mayet,
J. Billard,
G. Bernard,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
C. Koumeir,
J. P. Richer,
D. Santos,
P. Colas,
E. Ferer,
I. Giomataris,
A. Allaoua,
L. Lebreton
Abstract:
Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.
Directional detection of galactic Dark Matter is a promising search strategy for discriminating geniune WIMP events from background ones. We present technical progress on gaseous detectors as well as recent phenomenological studies, allowing the design and construction of competitive experiments.
△ Less
Submitted 18 January, 2010;
originally announced January 2010.
-
Development of a front end ASIC for Dark Matter directional detection with MIMAC
Authors:
J. P. Richer,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
F. Mayet,
D. Santos
Abstract:
A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the framework of the MIMAC detector project, which aims at directional detection of non-baryonic Dark Matter. This search strategy requires 3D reconstruction of low energy (a few keV) tracks with a gaseous \muTPC. The development of this front end ASIC is a key point of the project, allowing the 3D track reconstruction. Each ASIC m…
▽ More
A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the framework of the MIMAC detector project, which aims at directional detection of non-baryonic Dark Matter. This search strategy requires 3D reconstruction of low energy (a few keV) tracks with a gaseous \muTPC. The development of this front end ASIC is a key point of the project, allowing the 3D track reconstruction. Each ASIC monitors 16 strips of pixels with charge preamplifiers and their time over threshold is provided in real time by current discriminators via two serializing LVDS links working at 320 MHz. The charge is summed over the 16 strips and provided via a shaper. These specifications have been chosen in order to build an auto triggered electronics. An acquisition board and the related software were developed in order to validate this methodology on a prototype chamber. The prototype detector presents an anode where 2 x 96 strips of pixels are monitored.
△ Less
Submitted 13 April, 2010; v1 submitted 1 December, 2009;
originally announced December 2009.
-
The case for a directional dark matter detector and the status of current experimental efforts
Authors:
S. Ahlen,
N. Afshordi,
J. B. R. Battat,
J. Billard,
N. Bozorgnia,
S. Burgos,
T. Caldwell,
J. M. Carmona,
S. Cebrian,
P. Colas,
T. Dafni,
E. Daw,
D. Dujmic,
A. Dushkin,
W. Fedus,
E. Ferrer,
D. Finkbeiner,
P. H. Fisher,
J. Forbes,
T. Fusayasu,
J. Galan,
T. Gamble,
C. Ghag,
I. Giomataris,
M. Gold
, et al. (87 additional authors not shown)
Abstract:
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's stat…
▽ More
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.
△ Less
Submitted 1 November, 2009;
originally announced November 2009.
-
A prototype of a directional detector for non-baryonic dark matter search: MIMAC (Micro-TPC Matrix of Chambers)
Authors:
C. Grignon,
G. Bernard,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
C. Koumeir,
F. Mayet,
D. Santos,
P. Colas,
E. Ferrer,
I. Giomataris,
A. Allaoua,
L. Lebreton
Abstract:
We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are…
▽ More
We have developed a micro-tpc using a pixelized bulk micromegas coupled to dedicated acquisition electronics as a read-out allowing to reconstruct the three dimensional track of a few keV recoils. The prototype has been tested with the Amande facility at the IRSN-Cadarache providing monochromatic neutrons. The first results concerning discrimination of a few keV electrons and proton recoils are presented.
△ Less
Submitted 30 October, 2009; v1 submitted 3 September, 2009;
originally announced September 2009.
-
Dark matter directional detection with MIMAC
Authors:
C. Grignon,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
C. Koumeir,
F. Mayet,
D. Santos,
P. Colas,
E. Ferrer,
I. Giomataris
Abstract:
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are…
▽ More
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are presented as a proof of concept.
△ Less
Submitted 29 May, 2009;
originally announced May 2009.
-
MIMAC : a micro-TPC detector for non-baryonic dark matter search
Authors:
F. Mayet,
O. Guillaudin,
D. Santos,
A. Trichet
Abstract:
The MIMAC project is multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented.
The MIMAC project is multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented.
△ Less
Submitted 28 May, 2009;
originally announced May 2009.
-
Micromegas micro-TPC for direct Dark Matter search with MIMAC
Authors:
F. Mayet,
O. Guillaudin,
C. Grignon,
C. Koumeir,
D. Santos,
P. Colas,
I. Giomataris
Abstract:
The MIMAC project is a multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented, together with the first simulation of the track reconstruction. Recontruction of track of…
▽ More
The MIMAC project is a multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented, together with the first simulation of the track reconstruction. Recontruction of track of alpha from Radon impurities is shown as a first proof of concept.
△ Less
Submitted 28 May, 2009;
originally announced May 2009.
-
Low energy measurements with Helium Micromegas micro-TPC
Authors:
O. Guillaudin,
F. Mayet,
C. Grignon,
C. Koumeir,
D. Santos,
P. Colas,
I. Giomataris
Abstract:
The measurement of the ionization produced by particles in a medium presents a great interest in several fields from metrology to particule physics and cosmology. The ionization quenching factor is defined as the fraction of energy released by ionisation by a recoil in a medium compared with its kinetic energy. At low energy, in the range of a few keV, the ionization falls rapidly and systematic…
▽ More
The measurement of the ionization produced by particles in a medium presents a great interest in several fields from metrology to particule physics and cosmology. The ionization quenching factor is defined as the fraction of energy released by ionisation by a recoil in a medium compared with its kinetic energy. At low energy, in the range of a few keV, the ionization falls rapidly and systematic measurement are needed. We have developped an experimental setup devoted to the measurement of low energy (keV) ionization quenching factor for the MIMAC project. The ionization produced in the gas has been measured with a Micromegas detector filled with Helium gas mixture.
△ Less
Submitted 10 April, 2009;
originally announced April 2009.
-
MIMAC : Detection of low energy recoils for Dark Matter search
Authors:
A. Trichet,
F. Mayet,
O. Guillaudin,
D. Santos
Abstract:
The MIMAC project is based on a matrix of Micro Time Projection Chambers (micro-TPC) for Dark Matter search, filled with He3 or CF4 and using ionization and tracks. The first measurement of the energy resolution of this micro-TPC is presented as well as its low threshold
The MIMAC project is based on a matrix of Micro Time Projection Chambers (micro-TPC) for Dark Matter search, filled with He3 or CF4 and using ionization and tracks. The first measurement of the energy resolution of this micro-TPC is presented as well as its low threshold
△ Less
Submitted 10 April, 2009;
originally announced April 2009.
-
Ionization Quenching Factor Measurement of Helium 4
Authors:
D. Santos,
F. Mayet,
O. Guillaudin,
Th. Lamy,
S. Ranchon,
A. Trichet,
P. Colas,
I. Giomataris
Abstract:
The ionization quenching factor (IQF) is defined as the fraction of energy released by a recoil in a medium through ionization compared with its total kinetic energy. At low energies, in the range of a few keV, the ionization produced in a medium falls rapidly and systematic measurements are needed. We report measurements carried out at such low energies as a function of the pressure in He4 at 3…
▽ More
The ionization quenching factor (IQF) is defined as the fraction of energy released by a recoil in a medium through ionization compared with its total kinetic energy. At low energies, in the range of a few keV, the ionization produced in a medium falls rapidly and systematic measurements are needed. We report measurements carried out at such low energies as a function of the pressure in He4 at 350, 700, 1000 and 1300 mbar. In order to produce a nucleus moving with a controlled energy in the detection volume, we have developed an Electron Cyclotron Resonance Ion Source (ECRIS) coupled to an ionization chamber by a differential pumping. The quenching factor of He4 has been measured for the first time down to 1 keV recoil energies. An important deviation with respect to the phenomenological calculations has been found allowing an estimation of the scintillation produced in He4 as a function of pressure. The variation of the IQF as a function of the percentage of isobutane, used as quencher, is also presented.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.
-
MIMAC : A Micro-TPC Matrix of Chambers for direct detection of Wimps
Authors:
D. Santos,
O. Guillaudin,
Th. Lamy,
F. Mayet,
E. Moulin
Abstract:
The project of a micro-TPC matrix of chambers of He3 and CF4 for direct detection of non-baryonic dark matter is outlined. The privileged properties of He3 are highlighted. The double detection (ionization - projection of tracks) will assure the electron-recoil discrimination. The complementarity of MIMAC for supersymmetric dark matter search with respect to other experiments is illustrated.The…
▽ More
The project of a micro-TPC matrix of chambers of He3 and CF4 for direct detection of non-baryonic dark matter is outlined. The privileged properties of He3 are highlighted. The double detection (ionization - projection of tracks) will assure the electron-recoil discrimination. The complementarity of MIMAC for supersymmetric dark matter search with respect to other experiments is illustrated.The modular character of the detector allows to have different gases to get A-dependence. The pressure degreee of freedom gives the possibility to work at high and low pressures. The low pressure regime gives the possibility to get the directionality of the tracks. The first measurements of ionization at very few keVs for He3 in CF4 gas are described.
△ Less
Submitted 13 March, 2007;
originally announced March 2007.
-
MIMAC-He3 : MIcro-tpc MAtrix of Chambers of He3
Authors:
D. Santos,
O. Guillaudin,
T. Lamy,
F. Mayet,
E. Moulin
Abstract:
The project of a micro-TPC matrix of chambers of He3 for direct detection of non-baryonic dark matter is outlined. The privileged properties of He3 are highlighted. The double detection (ionization - projection of tracks) will assure the electron-recoil discrimination. The complementarity of MIMAC-He3 for supersymmetric dark matter search with respect to other experiments is illustrated. The mod…
▽ More
The project of a micro-TPC matrix of chambers of He3 for direct detection of non-baryonic dark matter is outlined. The privileged properties of He3 are highlighted. The double detection (ionization - projection of tracks) will assure the electron-recoil discrimination. The complementarity of MIMAC-He3 for supersymmetric dark matter search with respect to other experiments is illustrated. The modular character of the detector allows to have different gases to get A-dependence. The pressure degreee of freedom gives the possibility to work at high and low pressure. The low pressure regime gives the possibility to get the directionality of the tracks. The first measurements of ionization at very few keVs for He3 in He4 gas are described.
△ Less
Submitted 9 January, 2007;
originally announced January 2007.