MALTA-Cz: A radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate
Authors:
H. Pernegger,
P. Allport,
D. V. Berlea,
A. Birman,
D. Bortoletto,
C. Buttar,
E. Charbon,
F. Dachs,
V. Dao,
H. Denizli,
D. Dobrijevic,
M. Dyndal,
A. Fenigstein,
L. Flores Sanz de Acedo,
P. Freeman,
A. Gabrielli,
M. Gazi,
L. Gonella,
V. Gonzalez,
G. Gustavino,
A. Haim,
T. Kugathasan,
M. LeBlanc,
M. Munker,
K. Y. Oyulmaz
, et al. (14 additional authors not shown)
Abstract:
Depleted Monolithic Active Pixel Sensor (DMAPS) sensors developed in the Tower Semiconductor 180 nm CMOS imaging process have been designed in the context of the ATLAS ITk upgrade Phase-II at the HL-LHC and for future collider experiments. The "MALTA-Czochralski (MALTA-Cz)" full size DMAPS sensor has been developed with the goal to demonstrate a radiation hard, thin CMOS sensor with high granulari…
▽ More
Depleted Monolithic Active Pixel Sensor (DMAPS) sensors developed in the Tower Semiconductor 180 nm CMOS imaging process have been designed in the context of the ATLAS ITk upgrade Phase-II at the HL-LHC and for future collider experiments. The "MALTA-Czochralski (MALTA-Cz)" full size DMAPS sensor has been developed with the goal to demonstrate a radiation hard, thin CMOS sensor with high granularity, high hit-rate capability, fast response time and superior radiation tolerance. The small pixel size ($36.4\times 36.4$~$μ$m$^2$) provides high spatial resolution. Its asynchronous readout architecture is designed for high hit-rates and fast time response in triggered and trigger-less detector applications. The readout architecture is designed to stream all hit data to the multi-channel output which allows an off-sensor trigger formation and the use of hit-time information for event tagging.
The sensor manufacturing has been optimised through process adaptation and special implant designs to allow the manufacturing of small electrode DMAPS on thick high-resistivity p-type Czochralski substrate. The special processing ensures excellent charge collection and charge particle detection efficiency even after a high level of radiation. Furthermore the special implant design and use of a Czochralski substrate improves the sensor's time resolution. This paper presents a summary of sensor design optimisation through process and implant choices and TCAD simulation to model the signal response. Beam and laboratory test results on unirradiated and irradiated sensors have shown excellent detection efficiency after a dose of $2\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$. The time resolution of the sensor is measured to be $σ=2$~ns.
△ Less
Submitted 13 September, 2023; v1 submitted 10 January, 2023;
originally announced January 2023.
-
Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC
Authors:
M. Dyndal,
V. Dao,
P. Allport,
I. Asensi Tortajada,
M. Barbero,
S. Bhat,
D. Bortoletto,
I. Berdalovic,
C. Bespin,
C. Buttar,
I. Caicedo,
R. Cardella,
F. Dachs,
Y. Degerli,
H. Denizli,
L. Flores Sanz de Acedo,
P. Freeman,
L. Gonella,
A. Habib,
T. Hemperek,
T. Hirono,
B. Hiti,
T. Kugathasan,
I. Mandić,
D. Maneuski
, et al. (19 additional authors not shown)
Abstract:
Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silico…
▽ More
Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silicon. The design targets a radiation hardness of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$, compatible with the outermost layer of the ATLAS ITK Pixel detector. This paper presents the results from characterization in particle beam tests of the Mini-MALTA prototype that implements a mask change or an additional implant to address the inefficiencies on the pixel edges. Results show full efficiency after a dose of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$.
△ Less
Submitted 14 December, 2019; v1 submitted 26 September, 2019;
originally announced September 2019.
-
Measurement of the relative response of TowerJazz Mini-MALTA CMOS prototypes at Diamond Light Source
Authors:
Maria Mironova,
Kaloyan Metodiev,
Phil Allport,
Ivan Berdalovic,
Daniela Bortoletto,
Craig Buttar,
Roberto Cardella,
Valerio Dao,
Mateusz Dyndal,
Patrick Freeman,
Leyre Flores Sanz de Acedo,
Laura Gonella,
Thanushan Kugathasan,
Heinz Pernegger,
Francesco Piro,
Richard Plackett,
Petra Riedler,
Abhishek Sharma,
Enrico Junior Schioppa,
Ian Shipsey,
Carlos Solans Sanchez,
Walter Snoeys,
Hakan Wennloef,
Daniel Weatherill,
Daniel Wood
, et al. (1 additional authors not shown)
Abstract:
This paper outlines the results of investigations into the effects of radiation damage in the mini-MALTA prototype. Measurements were carried out at Diamond Light Source using a micro-focus X-ray beam, which scanned across the surface of the device in 2 $\mathrm{μm}$ steps. This allowed the in-pixel photon response to be measured directly with high statistics. Three pixel design variations were co…
▽ More
This paper outlines the results of investigations into the effects of radiation damage in the mini-MALTA prototype. Measurements were carried out at Diamond Light Source using a micro-focus X-ray beam, which scanned across the surface of the device in 2 $\mathrm{μm}$ steps. This allowed the in-pixel photon response to be measured directly with high statistics. Three pixel design variations were considered: one with the standard continuous $\mathrm{n^-}$ layer layout and front-end, and extra deep p-well and $\mathrm{n^-}$ gap designs with a modified front-end. Five chips were measured: one unirradiated, one neutron irradiated, and three proton irradiated.
△ Less
Submitted 2 October, 2019; v1 submitted 18 September, 2019;
originally announced September 2019.
-
Beam tests of an integrated prototype of the ATLAS Forward Proton detector
Authors:
J. Lange,
L. Adamczyk,
G. Avoni,
E. Banas,
A. Brandt,
M. Bruschi,
P. Buglewicz,
E. Cavallaro,
D. Caforio,
G. Chiodini,
L. Chytka,
K. Ciesla,
P. M. Davis,
M. Dyndal,
S. Grinstein,
K. Janas,
K. Jirakova,
M. Kocian,
K. Korcyl,
I. Lopez Paz,
D. Northacker,
L. Nozka,
M. Rijssenbeek,
L. Seabra,
R. Staszewski
, et al. (2 additional authors not shown)
Abstract:
The ATLAS Forward Proton (AFP) detector is intended to measure protons scattered at small angles from the ATLAS interaction point. To this end, a combination of 3D Silicon pixel tracking modules and Quartz-Cherenkov time-of-flight (ToF) detectors is installed 210m away from the interaction point at both sides of ATLAS. Beam tests with an AFP prototype detector combining tracking and timing sub-det…
▽ More
The ATLAS Forward Proton (AFP) detector is intended to measure protons scattered at small angles from the ATLAS interaction point. To this end, a combination of 3D Silicon pixel tracking modules and Quartz-Cherenkov time-of-flight (ToF) detectors is installed 210m away from the interaction point at both sides of ATLAS. Beam tests with an AFP prototype detector combining tracking and timing sub-detectors and a common readout have been performed at the CERN-SPS test-beam facility in November 2014 and September 2015 to complete the system integration and to study the detector performance. The successful tracking-timing integration was demonstrated. Good tracker hit efficiencies above 99.9% at a sensor tilt of 14°, as foreseen for AFP, were observed. Spatial resolutions in the short pixel direction with 50 μm pitch of 5.5 +/- 0.5 μm per pixel plane and of 2.8 +/- 0.5 μm for the full four-plane tracker at 14° were found, largely surpassing the AFP requirement of 10 μm. The timing detector showed also good hit efficiencies above 99%, and a full-system time resolution of 35 +/- 6 ps was found for the ToF prototype detector with two Quartz bars in-line (half the final AFP size) without dedicated optimisation, fulfilling the requirements for initial low-luminosity AFP runs.
△ Less
Submitted 2 November, 2016; v1 submitted 4 August, 2016;
originally announced August 2016.
-
Some open questions in hydrodynamics
Authors:
Mateusz Dyndal,
Laurent Schoeffel
Abstract:
When speaking of unsolved problems in physics, this is surprising at first glance to discuss the case of fluid mechanics. However, there are many deep open questions that come with the theory of fluid mechanics. In this paper, we discuss some of them that we classify in two categories, the long term behavior of solutions of equations of hydrodynamics and the definition of initial (boundary) condit…
▽ More
When speaking of unsolved problems in physics, this is surprising at first glance to discuss the case of fluid mechanics. However, there are many deep open questions that come with the theory of fluid mechanics. In this paper, we discuss some of them that we classify in two categories, the long term behavior of solutions of equations of hydrodynamics and the definition of initial (boundary) conditions. The first set of questions come with the non-relativistic theory based on the Navier-Stokes equations. Starting from smooth initial conditions, the purpose is to understand if solutions of Navier-Stokes equations remain smooth with the time evolution. Existence for just a finite time would imply the evolution of finite time singularities, which would have a major influence on the development of turbulent phenomena. The second set of questions come with the relativistic theory of hydrodynamics. There is an accumulating evidence that this theory may be relevant for the description of the medium created in high energy heavy-ion collisions. However, this is not clear that the fundamental hypotheses of hydrodynamics are valid in this context. Also, the determination of initial conditions remains questionable. The purpose of this paper is to explore some ideas related to these questions, both in the non-relativistic and relativistic limits of fluid mechanics. We believe that these ideas do not concern only the theory side but can also be useful for interpreting results from experimental measurements.
△ Less
Submitted 16 December, 2014; v1 submitted 8 September, 2014;
originally announced September 2014.