UPS Uninterruptible Power System

Innovation,Value,Teamwork

INVT Power System(Shenzhen)Co.,LTD Tel(86-755)26782764 Fax: (86-755)26782664 E-mailoverseasales@invt.com.cn Httpwww.invt-power.com AddGaofa Industrial Park,Longjing,Nanshan District,Shenzhen,China

28
RM series modular online UPS

7-14

HT33 series tower online UPS

15-20

HT11/HT31 series tower online UPS

21-22

HT11 series tower online UPS

23

HR series rack-mount online UPS

24

25

DIV series power inverter

26

DR series telecom rectifier

27

28

002334 UPS

30

Innovation,Value,Teamwork

www.invt-power.com.cn

Additional Outstanding Features

Innovation,Value,Teamwork

www.invt-power.com.cn

L L 72 PML06 PML12

RML072/12 RML120/12

187 214

10

Innovation,Value,Teamwork

www.invt-power.com.cn

1. Totally digital control system


Each power module is configured with two DSP control boards. All the power conversions are controlled by digital signal. Excellent performance is realized together with all kinds of protection functions. The UPS system and the modules are not relied on any central controller thus there is no risk of single point failure.

3. High margin for IGBT stress


The IGBT voltage stress is much lower than the rating(600V) due to the excellent drive technology. The reliable design of the power circuits highly increases the system reliability.

2. High reliability IGBT drive design, high power charger


High reliability design of IGBT drive and protection increases the system reliability. All the PCBs are protected by conformal coating, increases the environment adaptability of different applications.

4. Intelligent control and monitoring system


DSP based control and monitoring system offers all kinds of control functions and information of the system. The parameters and status of the UPS system can be calibrated by the touch screen panel or the laptop based software.

High reliability of plug-in design of IGBT drive Each power module is configured with independent high power charger

Conformal coating for all the PCBs inside the UPS

11

12

Innovation,Value,Teamwork

www.invt-power.com.cn

5. Excellent current sharing performance between the modules


The current difference between two online modules is controlled below 2%, the system reliability is highly increased due to the precise current sharing technology.

8. Intelligent system parameter calibration function


The parameter of UPS system can be calibrated through the touch screen panel.

9. Intelligent battery management system


The touch screen panel offers the technical information of the battery, the charging and discharging parameters can be set from the panel. The battery test and maintenance can be realized by the panel of the UPS.

6. Inbuilt battery cold start unit


As a standard configuration, inbuilt battery cold start unit make it possible to start the UPS directly from the battery when the utility is not available.

7. Incredible load capability


The instantaneous current sharing between the modules can be controlled within 2% even step on or step off 100% load.
Output voltage of UPS when step on 100% load Output current of module when step on 100% load

The DC bus voltage waveform of UPS during the process of battery cold start.

10. Intelligent component level diagnose system


The status of all the key components inside the UPS can be monitored and displayed on the UPS panel, this function makes the maintenance of the system as simple as possible. Each bit on the figure represents the status of one component, it's easy for the maintenance people to identify the faulty component when there is a module or system fault.

13

14

Innovation,Value,Teamwork

www.invt-power.com.cn

HT33 Series Tower UPS


10KVA to 120 KVA(for 380V/400/415V Power System) 6KVA to 72 KVA(for 200V/208V Power System)

HT33010S HT33010

HT33015S HT33015

HT33020S HT33020

HT33030S HT33030

Product Introduction
INVT HT33 serial three phase UPS offers advanced technology that increases perfomance and reliability:three high speed DSPs with completed digital control fully ensure high quality of power supply,high input power factor makes UPS energy saving power.It also offers humanization design:full front access of serviceability,user-friendly interface.
settable

Application:ISP(Internet Service Provider),IDC(Internet Data Center),computing center,bank,server center,precise equipment and etc.

97/44

97.5/46

97.5/46

99.5/58

164

186

208

256 600*855*1600

278

15

600*855*1350

16

Innovation,Value,Teamwork

www.invt-power.com.cn

HTL33006S HTL33006

L L

S HTL33018S HTL33018

HTL33024

HTL33036

HTL33048

HTL33060

HTL33072

72

1. Totally digital control system


The double DSP based control system realized the digital control for all the power conversions of the UPS. Excellent performance is realized together with high reliability of the system.

2. State of the art PCB design


Most of the components are SMT type, combine with the conformal coating technology, the reliability is much higher than the traditional DIP components design.

3. Excellent input performance


Input voltage of UPS Input current of UPS

High input power factor, low input total harmonic distortion of current, HT33 is green power system and energy saving products.

20PCS (18-22PCS acceptable)

97/44

97.5/46

99.5/58 600*855*1350 600*855*1600

17

18

Innovation,Value,Teamwork

www.invt-power.com.cn

4. Waveform display from the panel


The instantaneous output waveform of the UPS can be displayed on the panel.

7. Friendly control and monitoring system


Local RS232 or RS485 based control and monitoring software, realizes not only monitoring of the UPS status, but also calibration of all kinds of UPS parameters. SNMP based software offers remote monitoring to the system.

The interface of local control and monitoring software:

5. State of the art efficiency curve


Due to the three level technology, the efficiency curve of HT33 reaches the maximum stage when the load is between 50% to 75%. Comparing to the efficiency curve of traditional products, HT33 ensures the highest operation efficiency on most of the applications.

The interface of SNMP software:

6. Powerful load capability


HT33 achieves powerful load capability for all kinds of applications. 80kVA UPS is enough to handle 55kW motor through motor drive inverter.The waveform of putting 55kW motor and driver combined system to HT33 UPS:
Output current of UPS

The input and output current of UPS:

Output current of UPS

Input current of UPS

19

20

Innovation,Value,Teamwork

www.invt-power.com.cn

HT11/HT31 Series Online UPS


6 KVA 20 KVA 1:1 and 3:1 phase

1. DSP based control system


32 bit DSP based control system offers high speed data processing and signal control.

Model Capacity Cold Start

HT1106S

HT1106L

HT1110S HT1110L
10KVA/9KW

HT1115L

HT1120L

HT3110L

HT3115L

HT3120L

2. High power charging capability


Intelligent charging and discharging control system realize excellent battery management. Inbuilt 5A charging board offers powerful capability for long backup time application.

6KVA/5.4KW

15KVA/13.5KW 20KVA/18KW 10KVA/9KW 15KVA/13.5KW 20KVA/18KW

YES, default frequency=50Hz or settable 50%~125%(220VAC/230VAC/240VAC) 100% load@80%~125% 50%~125%(380VAC/400VAC/415VAC) 100% load@80%~125% 90% load@70%~80% 80% load@60%~70% 65% load@50%~60% three phase in, single phase out 0.95 0.95 0.95

Acceptable Input Voltage

90% load@70%~80% 80% load@60%~70% 65% load@50%~60%

Phase Input Power Factor Input Frequency Range Frequency adaptable Output PF Nominal voltage Voltage regulation Voltage regulation Battery number Efficiency(line mode) ECO mode Noise
<48dB@<70%load, <58dB@>70%load; 1m away
12V7AH*16PCS

Single phase in,single phase out 0.99 0.99 40Hz-70Hz Settable 0.9 220/230/240VAC 1%

220/230/240VAC 1%

linear load non-linear load


16PCS
12V9AH*16PCS

linear load non-linear load


16PCS 16PCS 93% 99%

3. Intelligent parallel function


Up to 8 units of paralleling, offers flexible configuration for redundant application.

93% 99% <48dB@<70%load, <60dB@>70%load; 1m away

<48dB@<70%load, <60dB@>70%load; 1m away 110%:Transfer to bypass after 60 mins. 130%:Transfer to bypass after 1 min 150%:Transfer to bypass after 30s, shutdown after 1 min.(Line mode) 3:1 LED+LCD
Standard Cable support INVT Power Monitor
Power Managment from SNMP Manager and Web

110%: Transfer to bypass after 60 mins.

Overload Capability (Line Mode) Crest Ratio Display RS232 SNMP card W*H*L
526*250*640 58

130%: Transfer to bypass after 1 min 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) 3:1 LED+LCD Standard Cable support INVT Power Monitor Power Managment from SNMP Manager and Web

526*250*480 17

526*250*640 526*250*480 64.5 19

544*250*750

544*250*750

526*250*640

544*250*750

544*250*750

21

Net Weight (KG)

33

33

25

33

33

22

Innovation,Value,Teamwork

www.invt-power.com.cn

HT11 Series Online UPS

HR Series Online UPS

H R1101S

H R1101L

H R1102L

H R1103L

H R1106L

H R1110L

HT 1101 S

HT 1101L

HT 1102 S

HT 1102L

HT 1103 S

HT 1103L

1KVA/0.8KV

2KVA/1.6KV
~

3KVA/2.4KV

~ ~

23

24

Innovation,Value,Teamwork

www.invt-power.com.cn

BU Seris Offline UPS

DIV Series Telecom and Electric Power Inverter

Features:

or

Model

DIV500

DIV1000

DIV2000

DIV3000

DIV4000

DIV5000

DIV6000

2.3 500VA 400W 1.8

4.5 1000VA 800W 3.6

12V/24V/48V/110V/220V 10% 185V 265V(10V) 13.6 9.1 18.2 5ms 2000VA 3000VA 4000VA 1600W 2400W 3200W 220Vac, 50Hz 10.8 14.5 7.2 2201.5% 500.1% 3% 5% 0.8/0.7/0.6 220% 30 sec 85%

22.7 5000VA 3500W 16

27.3 6000VA 4200W 19.1

Waveform

5ms 1500Vac, 40dB -25 ~+50


2000 LED
19 Inch Rack Type (DWH) (mm)

Input/output voltage, frequency, output current, temperatuer lineinverterbatteryoutput Load 360*448*88 (DIV 24-1KVA; DIV 48-1KVA/2KVA; DIV 110-1KVA/2KVA; DIV 220- 1KVA/2KVA) 390*448*88 (DIV 24-2KVA ; 3KVA; 4KVA; 5KVA; 6KVA) 7KG (1KVA); 8KG (2KVA); 11KG (3KVA); 12KG (4KVA); 13KG (5KVA); 14KG (6KVA)

25

26

Innovation,Value,Teamwork

www.invt-power.com.cn

DR Series Telecom Rectifier System

MF Series Sealed Lead Acid Battery

Features:

Features:

Battery model
MF4-12 MF7-12 MF9-12 MF12-12 MF17-12 MF24-12 MF38-12 MF65-12

Voltage(V)
12 12 12 12 12 12 12 12 12 12 12 12 12 6 6 6 6 6 6 6 6 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

Capacity(Ah)
4 7 9 12 17 24 38 65 100 120 150 200 250 4 7 9 12 100 150 200 300 100 150 200 250 300 350 400 450 500 600 800 1000 1200 1500 2000 2500 3000

Length
mm 90 151 151 151 181 166 197 350 328 410 482 522 520 70 151 98 151 195 260 250 295 171 172 173 173 171 171 210 210 241 302 410 475 475 400 490 490 710

Dimension (1mm) Total height Width Height


mm 70 65 65 98 77 175 165 167 171 176 170 238 269 47 34 56 50 170 180 125 178 72 102 111 111 151 151 176 176 175 175 175 175 175 350 350 350 350 mm 101 94 96 95 167 125 170 179 214 227 242 218 220 101 94 117 94 207 247 362 345 206 205 330 330 330 330 330 330 330 330 330 330 330 345 345 345 345 mm 107 100 100 101 171 129 170 179 220 227 242 222 224 107 100 117 100 213 251 266 350 311 227 364 364 364 364 367 367 365 367 367 367 367 382 382 382 382

Weight5% Kg 1.52 2.15 2.5 3.4 5.2 7.6 12.4 19.6 30.5 33.5 44.5 60 69.5 0.65 1.08 1.35 1.7 16.5 23.5 31 47 6.3 8.1 13.5 15.5 18.5 21 25.5 28 32 37 52 61 71 92 119 140 184

DR1400

DR1600

MF100-12 MF120-12 MF150-12 MF200-12 MF250-12

30A

MF4-6 MF7-6 MF9-6 MF12-6 MF100-6 MF150-6 MF200-6 MF300-6 MF100-2 MF150-2 MF200-2 MF250-2 MF300-2 MF350-2 MF400-2 MF450-2 MF500-2 MF600-2 MF800-2 MF1000-2 MF1200-2 MF1500-2 MF2000-2 MF2500-2 MF3000-2

27