Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Vickers H Series

Download as pdf or txt
Download as pdf or txt
You are on page 1of 27

Vickers

Piston Pumps

PVH Piston Pumps


High flow, high performance pumps for industrial and mobile applications

Revised 9/93

GBC2010

Introduction

PVH high flow, high performance pumps are a family of variable displacement, inline piston units that incorporate the proven design, quality manufacturing techniques and operating features of other Vickers piston pumps, but in a smaller, lighter package. The PVH series has been specially designed to meet the 250 bar (3625 psi) continuous duty performance requirements of new generation equipment designs.

These are efficient , reliable pumps, with a selection of optional controls for maximum operational flexibility. Designed specifically for strenuous application, they provide the productivity gains and controllability improvements desired in earthmoving, construction, machine tool, plastics, and all other energy-conscious markets. As with all Vickers products, these pumps have been fully laboratory tested and field proven.

PVH Series Benefits


D Versatile design includes single pumps, thru-drive arrangements, and a variety of drive shaft and control options that will adapt to any application and provide the most cost effective installation. D Proven components designed into a heavy duty, compact housing to provide 250 bar (3625 psi) continuous operating performance, and 280 bar (4050 psi) operating performance in a load sensing system. This design assures long life at the higher performance levels required of todays power-dense machinery. D Compact and lightweight design to reduce the application weight, and provide better access for installation and servicing. D Service kits developed for the most critical rotating and control components to simplify and assure successful pump servicing. . D Quiet designs available for noise-sensitive industrial applications, reducing sound levels further to provide a more acceptable environment. D Designed for maximum efficiency in any type of application. A variety of compensators provide the most effective system control, and the 95%-plus volumetric efficiency means more flow, and more input energy, is directed to the work and not into heat and waste. D Heavy duty bearings and shafts result in minimum internal deflections and wear, providing for longer life and maximum uptime.

Table of Contents
Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Performance Data
Rated characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Performance curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Response data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Sound levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Control Options
Pressure compensator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Load sensing and pressure compensator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Remotely controllable pressure compensator with load sensing option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Pressure and torque limiter control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Pressure and torque limiting plus load sensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Input Shaft Selection Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Input Shaft Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Installation Dimensions


Basic pumps (non-thru-drive) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Adjustable maximum volume stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Thru-drive pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 ISO pump mounting flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Combination 2-bolt/4-bolt SAE pump mounting flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Rear cover for thru-drive pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Pumps for shaft-up operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Foot mounting kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Application Data
Hydraulic fluids and temperature ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Fluid cleanliness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Drive data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Weights, Ordering, Installation and Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Model Codes

1 1

10

11

12

13

14 12

15

16

Pump series

Maximum geometric displacement 57 = 57,4 cm3/r (3.5 in3/r) 74 = 73,7 cm3/r (4.5 in3/r) 98 = 98,3 cm3/r (6.0 in3/r) 131 = 131,1 cm3/r (8.0 in3/r)
2 3

7 Main ports F = SAE 4-bolt flange ports M = SAE 4-bolt flange ports with metric mounting bolt threads 8

Pressure compensator factory setting in tens of bar 25 = Normal factory setting of 250 bar (3625 psi) for C models. 7 = Normal factory setting of 70 bar (1015 psi) for CM models.
13 Additional control functions Blank = No additional controls V = Load sensing, 20 bar (290 psi) differential pressure setting T = Torque limiter VT = Load sensing and torque limiter 14 Torque limiter factory setting (Use with T and VT above) ** = Customer desired torque limiter setting specified in ten bar (145 psi) increments, e.g.: 8 = 80 bar (1160 psi); 18 = 180 bar (2610 psi).

Design/application

N 1 2 3 12 13 16

Blank = Design for mobile applications QI = Quiet design for industrial applications Mouting flange, prime mover end C = SAE C 4bolt type (SAE J744-127-4) M = ISO 3019/2125B4HW (Option for PVH57 and PVH only. Must use N shaft.)
4

Shaft rotation, viewed at prime mover end R = Right hand (clockwise) L = Left hand (counterclockwise)
5 6 Configuration Blank = Non-thru-drive (single pump) A = Thru-drive pump with SAEA 2-bolt rear flange mounting (SAE J744-82-2) B = Thru-drive pump with SAE B 2- and 4-bolt rear flange mountings (SAEJ744-101-2/4) C = Thru-drive pump with SAE C 2- and 4-bolt rear flange mountings (SAEJ744-127-2/4) S = Adjustable maximum volume stop (non-thru-drive and non-torque-control models only)

Shaft-end type, at prime mover end (See torque limits on page 14 and shaft dimensions on page 15.) = ISO 3019/2-E32N short straight keyed (Must use M mtg. flg.) = SAE C straight keyed (J744-32-1) = SAE C splined 14 tooth 12/24 D.P. (J744-32-4) = SAE CC splined 17 tooth 12/24 D.P. (J744-38-4) = SAE D splined 13 tooth 8/16 D.P. (J744-44-4) = SAE CC straight keyed (J744-38-1) = SAE D straight keyed (J744-44-1)

Shaft seal, prime mover end S = Single, one-way. D = Double, two-way. Recommended on second pump of tandem assembly (PVH**/ PVH**) and wet mount applications.
9 10 Pump design number 10 (Subject to change. Installation dimensions unaltered for design numbers 10 to 19 inclusive.)

15 Control design number 31 = C, CM, C**V, or IC controls 13 = C**T controls 14 = C**VT controls

11

Built from pump with SAE A rear pad to which suitable flange adapter is bolted. For best availability and flexibility, order PVH SAE A thru-drive pump and SAE B or C adapter kit separately. ( See page 23.)

Pressure compensator and adjustment range C = 70-250 bar (1015-3625 psi) CM = 40-130 bar ((580-1885 psi) IC = Industrial control, 20 bar (290 psi) differential pres sure setting (QI models only)

Special features suffix 027 = Composite 2-bolt/4-bolt mounting conforming to SAE C (except PVH131) 031 = Thru-drive SAE A pad cover 041 = No case-to-inlet relief valve (for use with supercharged circuits). 3,4 bar (50 psi) maximum inlet pressure 057 = Shaft-up operation (vertical mount)

16

Note: Unloading valve controls for accumulator circuits are available. See your Vickers representative for circuit review and approval..

Performance Data
Performance data is typical with SAE 10W anti-wear hydraulic oil at 50 C (120 F) and at zero pump inlet pressure, except where otherwise indicated.

Rated Characteristics of PVH***QI Industrial Pumps


Parameters PVH57QI PVH74QI PVH98QI PVH131QI Geometric displacement, max. cm3/r 57,4 73,7 98,3 131,1 (in3/r) (3.5) (4.5) (6.0) (8.0) Rated pressure 250 250 250 250 bar (psi) (3625) (3625) 3625) (3625) Rated speeds in r/min at various inlet pressures 127 mm Hg (5 Hg) 1500 1500 1500 1200 Zero inlet pressure 1800 1800 1800 1500 0,48 bar (7 psi) 1800 1800 1800 1800 Typical effective flow in l/min (USgpm) at 250 bar (3625 psi) at 1500 r/min 83 102 140 186 (22) (27) (37) (49) at 1800 r/min 98 125 170 223 (26) (33) (45) (59)
In load sensing systems the compensator can be set at 280 bar (4060 psi).

Ratings of PVH***QI Industrial Pumps with Alternate Fluids


Petroleum Parameters based Max. pressure 250 bar (psi) (3625) Max. speed in r/min at: 1,0 bar abs. (0 psi) 1800 0,85 bar abs. (5 Hg) 1500 h Max. inlet temp. 93 deg. C (deg. F) (200)
1500 rpm for PVH131 only.

Polyol ester 230 (3300) 1800 1500 65 (150)

Water glycol HWBF(9010) thickened 172 155 (2500) (2250) 1800 1500 50 (120) 1700 1500 50 (120)

h 1200 rpm for PVH131 only.

Rated Characteristics of PVH*** Mobile Pumps Z


Parameters PVH57 PVH74 PVH98 Rated speeds in r/min at various inlet pressures 127 mm Hg (5 Hg) 2000 1850 1750 Zero inlet pressure 2400 2200 2100 0,48 bar (7 psi) 3000 2750 2600 Typical effective flow in l/min (USgpm) at 250 bar (3625 psi) and rated speed @ 134 156 202 zero inlet pressure (35) (41) (53) PVH131 1650 2000 2500 249 (66)

Z Displacements & rated pressure are same as for PVH***QI industrial pumps.

Performance Data
PVH57
Delivery and efficiency versus outlet pressure at 1800 r/min
Efficiency % Volumetric efficiency 100 80 60 40 20 0 250 Overall efficiency Effective flow (delivery) 200 150 100 50 0 (66) (53) (40) (26) (13) (0) 100 80 60 40 20 0 Effective flow (delivery) Overall efficiency Delivery l/min (USgpm)

PVH74
Delivery and efficiency versus outlet pressure at 1800 r/min
Efficiency % Volumetric efficiency 250 (66) 200 (53) 150 (40) 100 (26) 50 (13) 0 0 0 50 725 100 150 200 Outlet pressure, bar 1450 2175 2900 Outlet pressure (psi) 250 3625 (0) Delivery l/min (USgpm)

0 0

50

100 150 200 Outlet pressure, bar 1450 2175 2900 Outlet pressure (psi)

250

725

3625

Input torque and power versus outlet pressure at 1800 r/min


Input torque lb. ft. Nm (443) 600 (369) 500 (295) 400 Input torque (221) 300 Input power, full stroke (148) 200 (74) 100 (0) 0 0 0 50 100 150 200 Outlet pressure, bar 250 3625 Input power, cutoff 80 (107) 40 0 (54) (0) 120 (161) kw (hp) 240 (322) 200 (268) 160 (215)

Input torque and power versus outlet pressure at 1800 r/min


Input torque lb. ft. Nm (443) 600 (369) 500 (295) 400 (221) 300 (148) 200 (74) 100 (0) 0 50 0 100 150 200 Outlet pressure, bar Input torque Input power, full stroke Input power, cutoff kw (hp) 240 (322) 200 (268) 160 (215) 120 (161) 80 (107) 40 250 0 3625 (54) (0)

725 1450 2175 2900 Outlet pressure (psi)

725 1450 2175 2900 Outlet pressure (psi)

Input power versus speed


Input power (hp) kw (161) 120 (134) 100 (107) 80 (81) 60 (54) 40 (27) 20 0 0 600 1000 1500 2000 Speed r/min

Input power versus speed


Input power (hp) kw (161) 120 (134) 100 (107) 80 (81) 60 (54) 40 (27) 20 0 0 600 1000 1500 2000 Speed r/min

250 bar (3625 psi) 200 bar (2900 psi) 150 bar (2175 psi) 100 bar (1450 psi) 50 bar (725 psi)

250 bar (3625 psi) 200 bar (2900 psi) 150 bar (2175 psi) 100 bar (1450 psi) 50 bar (725 psi)

Performance Data
PVH98
Delivery and efficiency versus outlet pressure at 1800 r/min
Efficiency % Volumetric efficiency 100 80 60 40 20 0 Overall efficiency Effective flow (delivery) 250 200 150 100 50 0 (66) (53) (40) (26) (13) (0) Delivery l/min (USgpm)

PVH131
Delivery and efficiency versus outlet pressure at 1800 r/min
Efficiency % 100 80 Effective flow (delivery) 60 40 20 Overall efficiency 150 (40) 100 (26) 50 (13) 0 0 0 50 100 150 200 Outlet pressure, bar 250 (0) Volumetric efficiency 250 (66) 200 (53) Delivery l/min (USgpm)

0 0

50

100 150 200 Outlet pressure, bar

250

725 1450 2175 2900 Outlet pressure (psi)

3625

725 1450 2175 2900 Outlet pressure (psi)

3625

Input torque and power versus outlet pressure at 1800 r/min


Input torque (lb. ft.) Nm (443) (369) (295) (221) (148) (74) (0) 600 500 400 300 200 100 Input power, cutoff 0 0 0 50 100 150 Outlet pressure, bar 200 250 3625 Input torque Input power, full stroke kw (hp) 240 (322) 200 (268) 160 (215) 120 (161) 80 (107) 40 (54) 0 (0)

Input torque and power versus outlet pressure at 1800 r/min


Input torque lb. ft. Nm (443) 600 (369) 500 Input torque (295) 400 (221) 300 (148) 200 (74) 100 (0) 0 Input power, cutoff 50 100 150 Outlet pressure, bar 0 725 200 Input power, full stroke 160 (215) 120 (161) 80 (107) 40 (54) 250 0 3625 (0) kw (hp) 240 (322) 200 (268)

725 1450 2175 2900 Outlet pressure (psi)

1450 2175 2900 Outlet pressure (psi)

Input power versus speed


Input power (hp) kw (161) 120 (134) 100 (107) 80 (81) 60 (54) 40 (27) 20 0 0

Input power versus speed


Input power (hp) kw (161) 120 (134) 100 (107) 80 (81) 60 (54) 40 (27) 20 0 0 250 bar (3625 psi) 200 bar (2900 psi) 150 bar (2175 psi) 100 bar (1450 psi) 50 bar (725 psi) 600 1000 1500 2000 Speed r/min

250 bar (3625 psi) 200 bar (2900 psi) 150 bar (2175 psi) 100 bar (1450 psi) 50 bar (725 psi) 600 1000 1500 2000 Speed r/min

Performance Data
Performance data is typical with SAE 10W anti-wear hydraulic oil at 50 C (120 F) and at zero pump inlet pressure, except where otherwise indicated.

Rated Speed at Reduced Displacement and Zero Inlet Pressure


130 125 % of rated speed 120 115 110 PVH131 105 100 10 PVH98 Note: Speeds at 10% displacement represent maximums at load-sense standby condition. These speeds must be reduced to rated speeds at 100% displacement before leaving standby condition, or pump damage may result.

PVH57 PVH74

20

30

40 50 60 70 80 % of maximum displacement

90

100

Effective Flow at Maximum Torque


Effective flow (delivery) (USgpm) l/min (79) 300 (66) (53) (40) (26) (13) (0) 250 200 150 100 50 0 600 PVH131 PVH98 PVH74 PVH57 1200 2400 1800 Drive speed r/min _ _ _ 250 bar (3625 psi) 17 bar (250 psi)

Inlet Pressure/Vacuum versus Speed, Non-QI Models


(psi) (7.5) Inlet pressure (5.0) (2.5) (0) (5) (in Hg) bar 0,52 0,35 0,17 0 127 mm Hg 0 131 98 74 57

Inlet vacuum

400

800

1200 1600 2000 2400 2800 3200 3600 Speed r/min

Performance Data

Response Data
Model series/ Typical yoke Control type response On stroke Off stroke PVH57/C** PVH57/C**V PVH74/C** PVH74/C**V PVH98/C** PVH98/C**V PVH131/C** PVH131/C**V .101 sec. .080 sec. .097 sec. .088 sec. .134 sec. .118 sec. .139 sec. .118 sec. .015 sec. .014 sec .015 sec. .028 sec. .019 sec. .029 sec. .019 sec. .029 sec.

Sound Levels
Vickers PVH pumps are designed to provide the highest levels of system performance with noise levels within OSHA requirements. The standard models exhibit low sound levels across a wide range of operating speeds and pressures to accommodate the conditions necessary for high performance mobile vehicles. In addition, the quieter QI models provide even lower sound levels at typical in-plant conditions. Sound is generated by a variety of factors associated with the system, machine, and environment. For more information concerning the causes and nature of noise in machinery, and methods to reduce sound levels, refer to Vickers More Sound Advice bulletin 390 and Noise Control in Hydraulic Systems bulletin 510.

Based on 6900 bar/sec (100,000 psi/sec) pressure rise at rated speed and pressure.

Mobile Version Sound Level dB(a) DIN (NFPA)


Pressure bar (psi) PVH57 1200 r/min 69 (71) 74 (76) 75 (77) 75 (77) 1800 r/min 75 (76) 76 (78) 79 (81) 79 (81) PVH74 1200 r/min 69 (71) 74 (76) 75 (77) 75 (77) 1800 r/min 74 (76) 76 (78) 79 (81) 79 (81) PVH98 1200 r/min 69 (71) 71 (74) 75 (77) 76 (78) 1800 r/min 73 (75) 76 (78) 80 (82) 82 (84) PVH131 1200 1800 r/min r/min 74 (76) 79 (81) 81 (88) 81 (83) 78 (82) 85 (87) 87 (89) 88 (90)

70 (1015) 140 (2030) 210 (3025) 250 (3625)

Industrial Version Sound Level dB(a) DIN (NFPA)


Pressure bar (psi) PVH57QI 1200 1800 r/min r/min 62 (64) 64 (66) 68 (70) 69 (71) 69 (71) 71 (73) 74 (76) 76 (78) PVH74QI 1200 1800 r/min r/min 63 (65) 67 (69) 71 (73) 71 (73) 71 (73) 73 (74) 75 (77) 76 (78) PVH98QI 1200 1800 r/min r/min 67 (69) 68 (70) 73 (75) 75 (77) 73 (75) 74 (76) 78 (80) 80 (82) PVH131QI 1200 1800 r/min r/min 73 (75) 75 (77) 79 (80) 80 (82) 78 (80) 82 (84) 85 (87) 87 (89)

70 (1015) 140 (2030) 210 (3025) 250 (3625)

DIN: Computed semi-anechoic values per DIN 45635. NFPA: Recorded in a semi-anechoic chamber in accordance with NFPA Recommended Standard 13.9.70.12. All values shown are the higher of either maximum displacement or fully compensated conditions.

Due to the rounding of numbers during conversion, the difference between DIN and NFPA ratings may be one or two numbers; for example 69 (71) or 69 (72).

Control Options
C or CM Pressure Compensator Control
The pump will provide a continuously modulated flow to meet changing load demands at a pre-adjusted compensator pressure. At pressures below the compensator setting, the pump will operate at maximum displacement. The compensator is available in two pressure ranges. The C spring has an adjustment range of 70250 bar (10153625 psi). The CM spring has an adjustment range of 40130 bar (5801885 psi).

C or CM Control
Inlet

D D D

Case drain

Q
D D D D D

1,7 bar (25 psi)

P Outlet To load

C**V or CM*V Control


Inlet

C(M)*V Load Sensing and Pressure Compensator Control


The pump will provide power matching of pump output to system load demand, maximizing efficiency and improving load metering characteristics of any directional control valve installed between the pump and the load.
D D D D D

Case drain

Load sensing ensures that the pump always provides only the amount of flow needed by the load. At the same time, the pump operating pressure adjusts to the actual load pressure plus a pressure differential required for the control action. When the system is not demanding power, the load sense control will operate in an energy-saving stand-by mode. Typically, the differential pressure is that between the pressure inlet and service port of a proportionally controlled directional valve, or a load sensing directional control valve. The standard differential pressure setting for load sense is 20 bar (290 psi), but can be adjusted to between 17 and 30 bar (247 and 435 psi) on the pump.

1,7 bar (25 psi)

D D

Outlet Control valve


D

Load sense signal port

To load

If the load pressure exceeds the system pressure setting, the pressure compensator de-strokes the pump. The load sensing line must be as short as possible and can also be used for remote control or unloading of the pump pressure. For remote control purposes, it is recommended that you contact your Vickers representative for the correct configuration of the control.

10

Control Options

Pump with IC Compensator


This pump is intended for use when multiple, remote, or electrically controlled compensating settings, with or without load sensing, are desired. Pressure compensation is obtained when an internal plug is removed, the load-sense signal port is kept plugged, and internal pilot pressure is applied to the spring chamber of the control spool. For pressure compensation with load sensing, the internal plug stays, the load-sense signal port is unplugged, and pilot pressure is externally applied. An external relief valve (not supplied) controls spring chamber pressure.The externally adjustable spring determines the differential pressure setting of the control. Outlet pressure is limited to the value of the spring chamber (pressure port) pressure, plus control differential pressure. Spring chamber (pilot) pressure is separated from outlet pressure by an internal orifice. Outlet pressure shifts the spool when pressure drop across the orifice reaches the differential pressure setting, and the pump de-strokes. The relief valve can be mounted to an NFPA-D03/ISO 4401-03 pad on the pump control, or remotely located via tapping and blanking plates installed on the pad. See Ordering Procedure, page 27, for more on valves and plates. The standard factory-set differential pressure setting of the pump control is 20 bar (290 psi) and is not specified in the pump model number. Any other ordered differential pressure, within the controls adjustable pressure range of 1735 bar (247508 psi), will be specified in the model number following the IC control code; for example, -IC30- for a 30 bar setting.

IC Compensator
Pressure Compensating Without Load Sensing
Inlet

D D D D

Case drain Pressure port Tank port

D D D D D

1,7 bar (25 psi)

Outlet To load

Load sense signal port

Pressure Compensating with Load Sensing


Inlet

D D D D

Case drain Pressure port Tank port

D D D D D

1,7 bar (25 psi)

Outlet To load Load sense signal port

11

Control Options

C**T Pressure and Torque Limiter Control


The pump senses pressure and flow and starts destroking at a predetermined input torque level. The rate of flow reduction is normally tailored to follow the maximum power capability curve of the prime mover. Input torque is limited while the pressure compensator limits the system pressure. When the input speed remains constant (i.e. industrial drives), the torque limiter acts as an input power limiter. This allows a smaller electric motor to be used if maximum pressure and maximum flow are not required at the same time. At low load levels, the control permits high pump displacement and high load speeds. Under heavy loads, speed is reduced, preventing stalling of the prime mover. In the case of variable speed drives (I.C. engines), this function provides, in addition to pressure compensation or limiting, a torque limiting ability that can be adjusted to the torque/speed characteristics of the engine. The start of torque limiting (pump-destroking) is pressure dependent. This pressure is selectable (see model code) and is factory preset to between 30% and 80% of the maximum pressure control setting. The minimum torque pressure setting is 40 bar (580 psi). Example: C10T4. There is no CM spring option available with the torque limiting control.

C**T Control
Inlet

D D D D D

Case drain

Q
D D D D D D D D

1,7 bar (25 psi)

P Outlet To load

12

Control Options

C**VT Pressure and Torque Limiting, Plus Load Sensing, Control


The pumps control functions like a load sensing control, but with additional torque limiting tailored to the size of the drive motor selected. The limiting function is the same as for a pressure compensator with torque limiting (see C**T description, previous page). The combination of the two controls provides the following benefits: 1. The energy savings of a variable displacement load sensing control. 2. The pump pressure follows the load pressure. 3. The torque control allows smaller drive motors to be used. 4. The pressure compensator de-strokes the pump as maximum pressure is reached. 5. The pump pressure can also be remotely controlled using the load sense line. The C**VT control allows complete control of flow and pressure, either mechanically or electrically, if used with proportional valves.

C**VT Control
Inlet

D D D D D D D D D D D D D D D D

Case drain

1,7 bar (25 psi)

Outlet

Load sense signal port

To load

13

Input Shaft Selection Data


Multiple pump arrangements can be formed by a PVH thru-drive pump and any suitable pump (single or multiple) that can be installed on the SAE A, B, or C rear-mounting option available for the thru-drive pump. It is important to check that maximum torque values for individual pump sections, or complete pumps, occuring in a specific application will not exceed the limits tabled below.

Shaft code N 1

Shaft designation ISO 3019/2-E32N short straight keyed SAE C (J744-32-1) straight keyed SAE C (J744-32-4) 14T 12/24 DP FRSF spline SAE CC (J744-38-4) 17T 12/24 DP FRSF spline SAE D (J744-44-4) 13T 8/16 DP FRSF spline SAE CC (J744-38-1) straight keyed SAE D (J744-44-1) straight keyed

Basic pump series PVH57 PVH74 PVH57 PVH74 PVH98 PVH57 PVH74 PVH98 PVH131 PVH131 PVH131

Thru-drive pump series PVH57 PVH57 PVH74 PVH98 PVH131 PVH131 PVH74 PVH98 PVH131

Maximum input torque Nm (lb. in.) 450 (3,980) 450 (3,980) 450 (3,980) 450 (3,980) 450 (3,980) 640 (5,660) 640 (5,660) 640 (5,660) 1215 (10,750) 1215 (10,750) 1215 (10,750) 1215 (10,750) 765 (6,770) 765 (6,770) 765 (6,770) 1200 (10,620)

Maximum thru-drive output torque Nm (lb. in.) 335 (2,965) 335 (2,965) 460 (4.070) 640 (5,660) 640 (5,660) 640 (5,660) 460 (4.070) 460 (4.070) 640 (5,660)

12 13

16

Note: Any deviation from maximum input torques must be approved by Vickers. To assure developed thru-drive loads are within PVH pump limitations, actual torque values must not exceed values shown.

14

Input Shaft Dimensions

C E square key

OA

Straight Keyed Shafts* A 31,75 (1.25) 13 SAE CC (J744-38-1) 38,10 (1.50) 16 SAE D (J744-44-1) 44,45 (1.75) N ISO 3019/2E32N 32,00 (1.26) * See torque limits on previous page. Shaft code 1 Shaft designation SAE C (J744-32-1) B 35,32 (1.38) 42,39 (1.67) 49,46 (1.95) 35,00 (1.38) C 48,0 (1.89) 54,0 (2.12) 67,0 (2.64) 58,0 (2.28) D 56,0 (2.20) 62,0 (2.44) 75,0 (2.95) 68,1 (2.68) E 7,93 (.312) 9,52 (.375) 11,11 (.438) 10,00 (.393)

Spline Shafts* Shaft code Shaft designation 2 SAE C (J744-32-4) 3 12 SAE CC (J744-38-4) SAE D (J744-44-4)

Number of teeth 14 17 13

C 48,0 (1.89) 54,0 (2.13) 67,0 (2.64)

D 56,0 (2.20) 62,0 (2.44) 75,0 (2.95)

* See torque limits on previous page.

15

Installation Dimensions
Basic Pump with Pressure Compensator and Load Sense Controls
Dimensions shown in mm (in.)
Outlet port. SAE J518C 4-bolt flange. Std. pressure (code 61) series for 57 to 98 sizes. High pressure (code 62) series for 131 size. Z Y

3rd angle projection

X W

U V View A-A Optional drain port. For .500 O. D. tube, .750-16 UNF-2B thread (PVH57 & 74). For .625 O. D. tube, .87514 UNF2B thread (PVH98 & 131).

Load sense adjustment. Approx. 14 bar (200 psi) differential change per revolution of screw. D Compensator adjustment. Approx. 28 bar (400 psi) change per revolution of screw.

Centerline of outlet port

Load sensing signal port. SAE O-ring boss for .375 O. D. tube. .562-18 UNF -2B thread. Outlet pressure gauge port. M10 thd. 25,4 (1.00) deep. O-ring boss. (plugged)

B J 57,25 (2.25) 57,25 (2.25) I K

57,25 (2.25)

Full R 45 57,25 (2.25) 14,53 (0.57) 14,15 (0.56) Drain port. SAE O-ring boss. .500 O. D. tube, .750-16 UNF-2B thread (PVH57 & 74). .626 O. D. tube, .875-14 UNF-2B thread (PVH98 & 131). 2 places 48,00 (1.89) N O F model: .500-13 UNC -2B thd. 1.06 deep min. for PVH57/74. 1.19 deep min. for PVH98/131. 4 holes. M model: M12 thd. 29 deep min. for PVH57/74. 31 deep min. for PVH98/131. 4 holes.

S T

For shaft options and dimensions, see pages 14 and 15.Standard SAE pump mounting flange shown; see page 24 for optional SAE 2-bolt/4-bolt and ISO flanges. See page 25 for shaft-up mounting option.

O 127,00 (5.000) 126.95 (4.998)

No. 2 shaft

R 12,45 (0.49) M L P inlet. SAE J518C 4-bolt flange port. Standard pressure series.

16

Installation Dimensions
Basic Pump with Pressure Compensator and Load Sense Controls
A PVH57 PVH74 PVH98 PVH131 76,0 (2.99) 88,0 (3.46) 93,1 (3.67) 109,4 (4.31) B 71,0 (2.79) 70,0 (2.75) 85,0 (3.35) 88,8 (3.50) C 293,0 (11.54) 306,6 (12.07) 323,5 (12.74) 377,0 (14.84) D 216,5 (8.52) 241,2 (9.50) 251,3 (9.89) 280,4 (11.04) E 171,3 (6.74) 194,3 (7.65) 206,1 (8.11) 230,4 (9.07) F 86,0 (3.39) 92,0 (3.62) 94,5 (3.72) 120,0 (4.72) G 79,0 (3.11) 94,0 (3.70) 87,5 (3.44) 109,0 (4.29) H 88,0 (3.46) 95,0 (3.74) 97,1 (3.82) 107,4 (4.23) I 69,0 (2.71) 81,0 (3.19) 80,1 (3.15) 84,8 (3.34)

J PVH57 PVH74 PVH98 PVH131 168,0 (6.6) 174.0 (6.85) 176,5 (6.95) 202,0 (7.95)

K 14,0 (0.55) 15,0 (0.59) 16,0 (0.63) 15,0 (0.59)

L 227,4 (8.95) 250,1 (9.85) 269,3 (10.60) 298,6 (11.75)

M 56,1 (2.21) 56,0 (2.20) 55,5 (2.18) 62,0 (2.44)

N 71,0 (2.80) 70,0 (2.75) 85,0 (3.35) 88,8 (3.50)

O 64,8 (2.55) 68,0 (2.68) 74,2 (2.92) 70,6 (2.78)

P 50,8 (2.0) 50,8 (2.0) 63,5 (2.5) 63,5 (2.5)

Q 77,77 (3.06) 77,77 (3.06) 88,9 (3.50) 88,9 (3.50)

R 38,88 (1.53) 38,88 (1.53) 44,45 (1.75) 44,45 (1.75)

S PVH57 PVH74 PVH98 PVH131 42,88 (1.69) 42,88 (1.69) 50,8 (2.0) 50,8 (2.0)

T 21,44 (0.84) 21,44 (0.84) 25,4 (1.0) 25,4 (1.0)

U 25,4 (1.0) 25,4 (1.0) 25,4 (1.0) 31,75 (1.25)

V M10x1,5 (.375-16) M10x1,5 (.375-16) M10x15 (.375-16) M14x2,0 (.500-13)

W 52,37 (2.06) 52,37 (2.06) 52,37 (2.06) 66,68 (2.63)

X 26,18 (1.03) 26,18 (1.03) 26,19 (1.03) 33,34 (1.31)

Y 26,19 (1.03) 26,19 (1.03) 26,19 (1.03) 31,75 (1.25)

Z 13,10 (0.52) 13,10 (0.52) 13,10 (0.52) 15,88 (0.63)

17

Installation Dimensions
Basic Pump. Rear View with Various Controls.
63,0 (2.5) B

D plus 16 (.63) Centerline of load sense port for right hand rotation E

C D J

A F I

H Right hand rotation, pressure compensated and torque limit model

G Right hand rotation, pressure compensated model

Left hand rotation, pressure compensated and load sensing model

PVH57 PVH74 PVH98 PVH131

A 176,45 (6.95) 182,45 (7.18) 195.45 (7.69) 210,50 (8.29)

B 41,0 (1.61) 47,5 (1.87) 41,0 (1.61) 63,6 (2.50)

C 102,7 (4.04) 109,2 (4.30) 102,7 (4.04) 125,2 (4.92)

D* 64,5 (2.54) 71,0 (2.79) 65,5 (2.54) 87,0 (3.42)

E 49,0 (1.93) 55,5 (2.19) 49,0 (1.93) 71,5 (2.81)

F 176,6 (6.95) 182,6 (7.18) 185,1 (7.280 210,6 (8.29)

G 203,0 (7.99) 224,0 (8.82) 233,0 (9.17) 254,2 (10.00)

H 101,5 (4.00) 112,0 (4.41) 116,5 (4.59) 127,1 (5.00)

I 127,0 (5.00) 133,0 (5.23) 135,5 (5.33) 161,0 (6.37)

J 102,7 (4.04) 109,2 (4.30) 102,7 (4.04) 125,2 (4.92)

*Add 16,0 (.63) to dimension D for right hand rotation model.

Pump with Pressure Compensation, Load Sense and Torque Limit Controls
A B Optional load sensing signal port J. SAE O-ring boss for .375 O. D. tube. .562-18 UNF-2B thread. E 62,2 (2.45) D

Left hand rotation, pressure compensated with load sense and torque limit model

Optional load sensing signal port J. SAE O-ring boss for .375 O. D. tube. .562-18 UNF-2B thread. (plugged)

PVH57 PVH74 PVH98 PVH131

A 300,2 (11.82) 322,9 (12.71) 335,1 (13.19) 359,5 (14.15)

B 177,4 (6.98) 200,1 (7.88) 212,3 (8.36) 236,6 (9.31)

C 168,1 (6.62) 174,1 (6.85) 187,1 (7.37) 202,2 (7.96)

D 41,4 (1.63) 47,9 (1.86) 41,4 (1.63) 63,8 (2.51)

E 195,4 (7.69) 201,4 (7.93) 214,4 (8.44) 229,5 (9.04)

18

Installation Dimensions
Pump with IC Compensator (Remotely Controllable Pressure Compensator, and Optional Load Sensing)
Tank port O 4,0 (.157)

Pressure port 31,0 (1.220) 25,8 (1.016) #1024 UNC thread .57 deep minimum, or M5 14,0 deep minimum

5,2 (.205) 32,5 (1.279) O 5,0 (.197) 2 places 7,5 (.295) A Control surface, ISO4401 size 03. Available with metric or UNC mounting holes to order Access plug C Internal plug Load sense port (if used). SAE O ring boss for .375 O. D. tube. .56218 UNF-2B thread Load-sense port plug D E 21,5 (.846) 40,5 (1.594) 0,75 (.029) 15,5 (.610)

Pressure compensator with load sensing: Pressure compensator: Remove access plug, using 1/8 inch hex wrench. Remove internal plug, using 5/32 inch hex wrench. Replace access plug and torque to 12,112,4 Nm (107110 lb. in.). Attach relief valve hardware (not supplied) to control surface. See page 11 for more details. Remove load-sense port plug. (Internal plug must remain in place.) Attach line to load-sense port. Pressure decay rate of this line must not exceed 11 kbar/second (160 kpsi/second). Attach relief valve hardware (not supplied) to control surface. See page 11 for more details.

PVH57 PVH74 PVH98 PVH131

A 234,5 (9.23) 257,2 (10.12) 269,3 (10.60) 293,6 (11.56)

B 72,5 (2.85) 79,0 (3.11) 72,5 (2.85) 95,0 (3.74)

C 269,9 (10.62) 292,6 (11.52) 304,7 (12.00) 329,0 (12.95)

D 128,0 (5.04) 134,0 (5.27) 136,5 (5.37) 162,0 (6.38)

E 142,0 (5.59) 148,0 (5.83) 150,5 (5.92) 176,0 (6.93)

19

Installation Dimensions
Pump with Adjustable Maximum Volume Stop
This option allows maximum pump delivery to be externally adjusted from 25 to 100 percent. To assist initial priming, adjust stop to allow at least 40 percent of maximum delivery. Adjust by loosening locknut and turning adjusting rod clockwise to decrease maximum delivery, or counterclockwise to to increase maximum delivery. When desired setting is obtained, torque locknut to 25-50 Nm (18-36 lb. ft.).

A max

Locknut B

Adjusting rod Right hand rotation model.

C Approx. displacement change per revolution of rod: PVH57 4,25 cm3 (0.259 in3) PVH74 5,00 cm3 (0.305 in3) PVH98 6,25 cm3 (0.381 in3) PVH131 8,50 cm3 (0.519 in3)

A PVH57 PVH74 PVH98 PVH131 293,0 (11.53) 306,6 (12.07) 323,5 (12.74) 377,0 (14.84)

B 20,0 (.79) 22,0 (.87) 27,5 (1.08) 37,5 (1.48)

C 69.5 (2.74) 76,0 (2.99) 81,0 (3.19) 88,8 (3.50)

20

Installation Dimensions
Thru-drive Pumps with SAE A Rear Pad
Load sensing signal port. SAE O-ring boss for .375 O. D. tube. .562-18 UNF2B thread. Centerline of outlet port C D 4 82,63 (3.253) 82,58 (3.251) SAE A internal involute spline. 9 teeth 16/32 pitch, 30 pr. angle. L .375-16 UNC-2B thread .58 deep min., or M10 thread 18,0 deep min.

K External involute spline E

53,20 (2.1)

G 53,20 (2.1) O N Right hand rotation, pressure compensated and load sensing model. 53,20 (2.1)

H A B

R 1,00 (0.04) max 9,00 (0.35) 8,00 (0.31)

53,20 (2.1)

For shaft options and dimensions, see pages 14 and 15. See page 24 for optional cover for rear pad.

Note: The O-ring for sealing the rear mounting pad is furnished with the pump. The rear drive coupling shown must be ordered separately; see page 23

A PVH57 PVH74 PVH98 PVH131 287,9 (11.3) 310.6 (12.23) 322,8 (12.71) 347,1 (13.660

B 295,4 (11.6) 318,1 (12.52) N/A N/A

C 275.8 (10.86) 300,5 (11.83) 312,7 (12.31) 337,0 (13.27)

D 216,4 (8.52) 241,2 (9.50) 251,3 (9.89) 280,4 (11.04)

E 86,0 (3.38) 92,0 (3.62) 94,5 (3.72) 120,0 (4.72)

F 79,0 (3.11) 94,0 (3.70( 87,5 (3.44) 109,0 (4.29)

G 88,0 (3.46) 95,0 (3.74) 97,1 (3.82) 107,4 (4.23)

H 36,4 (1.43) 38,5 (1.51) 33,0 (1.30) 35,3 (1.39)

PVH57 PVH74 PVH98 PVH131

I 43,6 (1.72) 43,8 (1.72) 44,6 (1.75) 44,7 (1.76)

J 69,0 (2.71) 81,0 (3.19) 80,1 (3.15) 84,8 (3.34)

K 14,0 (0.55) 15,0 (0.59) 16,0 (6.30) 15,0 (0.59)

L 102,7 (4.04) 109,2 (4.30) 102,7 (4.04) 125,2 (4.93)

M 176,6 (6.95) 182,6 (7.18) 185,1 (7.28) 210,6 (8.29)

N 203,0 (7.99) 224,0 (8.82) 233,0 (9.17) 254,2 (10.0)

O 101,5 (4.00) 112,0 (4.41) 116,5 (4.59) 127,1 (5.00)

21

Installation Dimensions
Thru-drive Pumps with SAE B Rear Pad Adapter
A B 12,50 (0.49) 11,50 (0.45) 92,0 (3.62) 44,90 (1.77) 44,90 (1.77) 73,00 (2.87) 73,00 (2.87) 44,90 (1.77)

O101,65 (4.002)
101,60 (4.000)

R 1,00 (0.04) max

Thru-drive pumps must have support located by dimension C.

44,90 SAE BB size, (1.77) side fit, internal 6 x D1 92,0 involute spline. (3.62) 15 teeth 16/32 pitch, 30 pr. 53,0 35,0 (1.38) angle. Or SAE B (2.10) size, side fit, 87,0 87,0 4 x D2 internal involute (3.42) (3.42) spline. 13 teeth SAE B rear mounting. Mounting pad is machined to 16/32 pitch, 30 accept AS568-155 O-ring. Mounting pad is connected pressure angle. to pump case and must be sealed.

Thru-drive Pumps with SAE C Rear Pad Adapter


A B 15,50 (0.61) 14,50 (0.57) 90,50 90,50 SAE C size, (3.56) (3.56) 57,25 57,25 side fit, internal (2.25) (2.25) involute spline. 14 teeth 12/24 pitch, 30 pressure 92,0 angle. Or SAE 57,25 CC size (except (3.62) (2.25) PVH57), side fit, internal involute 2 x D3 spline, 17 teeth 57,25 12/24 pitch, 30_ (2.25) pressure angle. 4 x D1 53,0 92,0 (2.10) 35,0 (1.38) (3.62) 108,5 108,5 127,05 (5.002) 4 x D2 O (4.19) (4.19) 127,00 (5.000) SAE C rear mounting. Mounting pad is machined R 1,00 (0.04) max to accept AS568-159 O-ring. Mounting pad is connected to pump case and must be sealed.

C D

Thru-drive pumps must have support located by dimension C. Pump Model PVH57 PVH74 PVH98 PVH131 A 36,4 (1.43) 33,5 (1.32) 33,0 (1.30) 35,3 (1.39) D1 M14x2,00 25 deep 0,500-13 UNC-2B 1.0 deep B 68,8 (2.71) 68,3 (2.69) 69,8 (2.75) 69,7 (2.74)

300,4 (11.82) 323,1 (12.72) 335,3 (13.20) 359,6 (14.16)

312,9 (12.32) 335,6 (13.21) 347,7 (13.69) 372,1 (14.65)

Note: The O-ring for sealing the rear mounting pad is furnished with the pump. The rear drive couplings shown must be ordered separately; see following page.

Metric Inch

D2 M12x1,75 25 deep 0.500-13 UNC-2B 1.0 deep

D3 M16x2,00 25 deep 0.625-11 UNC-2B 1.0 deep

22

Thru-drive Flange Kit and Shaft Coupling


Front pump model series PVH57 SAE (J744) mounting flange for rear pump A (J744-82-2) B (J744-101-2/4) BB (J744-101-2/4) C (J744-127-2/4) A (J744-82-2) B (J744-101-2/4) BB (J744-101-2/4) C (J744-127-2/4) CC (J744-127-2/4) A (J744-82-2) B (J744-101-2/4) BB (J744-101-2/4) C (J744-127-2/4 CC (J744-127-2/4) Mounting flange adapter kit number* Metric threads None required 876394 876394 876392 None required 876394 876394 876392 876392 None required 876394 876394 876392 876392 Inch threads None required 876390 876390 876389 None required 876390 876390 876389 876389 None required 876390 876390 876389 876389 Coupling part number** 526682 526694 526695 526696 864460 864457 864459 864458 864461 877039 877040 877044 877045 877046

PVH74

PVH98 PVH131

*The basic PVH thru-drive pump has an SAE A pad on the rear. An SAE B or C pad rear mounting requires flange adapters. Required adapters can be provided if specified in the pump model code. The best combination of price, availability and flexibility is achieved by ordering a PVH SAE A thru-drive model and the applicable PVH mounting flange adapter separately. For example, a PVH74C-RCF-3S-10-C25-31 may also be ordered as a PVH74C-RAF-3S-10-C25-31 and a 876389 flange adapter. ** Thru-drive shaft couplings must be ordered separately to drive the second pump.

Typical Rear Pumps for Thru-drive Assemblies


Mountng SAE A SAE B Piston pump series PVQ10/13 PVQ20/32 PVQ40/45 PVE19/21 PVE19/21 TA19 PVH57 PVH74 PVH98 PVH131 Shaft code 3 3 3 9 2 2 2 2 2 3 35V 352*V 11 11 Vane pump series V10 V20 20V 25V V2020 Shaft code 11 62 151 11 11

SAE BB SAE C

SAE CC

NOTE: The above Vickers pumps are examples of rear pumps for the thru-drive pumps dimensioned on pages 21 and 22.The thru-drive torque limits identified in the chart on page 14 must not be exceeded when applying these multiple pump systems.

23

ISO 3019/2-125B4HW Mounting Flange for PVH57 and PVH74 Pumps


56,57 (2.23) 56,57 (2.23) Full R 14,37 (.56) 14,00 (.55) 4 places 45_ 56,57 (2.23) 56,57 (2.23) O 125,00 124,94 (4.921) (4.919)

9,25 (.36)

SAE 2bolt/4-bolt Mounting (027 Option) for PVH57, PVH74 and PVH98 Pumps
57,25 (2.25) 57,25 (2.25) 14,53 (.57) 14,15 (.56) 4 places

45_ Full radius 57,25 (2.25) 73,80 72,20 (2.90) (2.84) 6 places 57,25 (2.25) Full radius 181,0 (7.12) O 127,00 126,95 (5.000) (4.998)

17,75 (.70) 17,37 (.68) 2 places

12,45 (.49)

90,50 (3.56)

Cover (031 Option) for Thru-drive SAE A Rear Mounting Flange


Optional 12,0 (.47) radius 4 places O 11,00 (.43) 2 holes 9,5 (.37) 0,8 (.03) R max.

37,61 (1.48) 102,0 (4.01) 37,61 (1.48)

82,55 O 82,45 (3.250) (3.246) 30_ 37,61 37,61 (1.48) (1.48) 102,0 (4.01)

Note: When cover (part number 939790) is ordered as a separate part, two screws (part number 170177) are required to attach the cover to the pumps rear mounting flange. The O-ring for sealing the rear mounting flange is furnished with each thru-drive pump.

13,39 (.53) 13,39 (.53)

1,00 (.04) 3,50 (.138)

24

Pumps for Shaft-up Operation (Vertical Mount, 057 Option)

Model PVH57
73,80 72,20 (2.90) (2.84) Dim. A Vertical mount port. For .125 O. D. tube. .3125-24 UNF-2B thread. 1,59 (.0625) maximum spotface depth Attach line from this port to primary case drain line. Join these lines at a distance above the face of the mounting flange that equals, or is less than, dimension A. Fill case with fluid up to this port prior to start-up.

PVH74 PVH98 PVH131

Dim. A 25,68/24.94 (1.01/0.98) 26,64/25,90 (1.05/1.02) 25,82/25,08 (1.02/0.99) 25,12/24,38 (.99/0.96)

Model FB-C4-10 Foot Mounting Kit for All PVH Pumps


73,6 (2.90)

101,8 (4.00)

Each kit (part no. 02-143419) includes bracket shown and four screws for mounting to the pump. Kits are not included with pumps and must be ordered separately by model number.

228,0 (8.98) 114,5 (4.5) 57,25 (2.25)

114,0 (4.5)

O11,0 thru O 37,0 spotface 1,0deep


4 places 18,0 (0.71) .500-13 UNC-2B thd. LOX 45 thru. 4 places. 23,0 (0.90)

0,5 R 114,5 (4.5) 174,75 (6.88)

O127,15 (5.006) O127,05 (5.002)

57,25 (2.25)

20,5 (0.8)

133,0 (5.24)

25

Application Data
Hydraulic fluids and temperature ranges
Use anti-wear hydraulic oil, or automotive type crankcase oil (designations SC, SD, SE or SF) per SAE J183 FEB80. Select a viscosity grade that will allow optimum viscosity, between 40 cSt (180 SUS) and 16cSt (80 SUS), to be achieved. Cold start capability at 5000 cSt. Max. intermittent temp. 104 C (220 F). For further information, see 694. Recommended cleanliness levels, using petroleum oil under common conditions, are based on the highest fluid pressure levels in the system and are coded in the chart below. Fluids other than petroleum, severe service cycles or temperature extremes are cause for adjustment of these cleanliness codes. See Vickers publication 561 for exact details. Vickers products, as any components, will operate with apparent satisfaction in fluids with higher cleanliness codes than those described. Other manufacturers will often recommend levels above those specified. Experience has shown, however, that life of any hydraulic components is shortened in fluids with higher cleanliness codes than those listed below. These codes have been proven to provide a long trouble-free service life for the products shown, regardless of the manufacturer. Drive arrangement should be by direct drive through a flexible coupling. Check pump installation drawing for concentricity and squareness tolerances. Torque capability of shafts in basic (non-thru-drive) pumps is well in excess of that needed for operation at rated pressure and maximum displacement. Limitations for multiple pumps formed by PVH thru-drives as front-end sections are specified in the chart on page 14.

Fluid cleanliness
Proper fluid condition is essential for long and satisfactory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials and additives for protection against wear of components, elevated viscosity and inclusion of air. Essential information on the correct methods for treating hydraulic fluid is included in Vickers publication 561; Vickers Guide to Systemic Contamination Control, available from your local Vickers distributor or by contacting Vickers, Incorporated. Recommendations on filtration and the selection of products to control fluid condition are included in 561.

Moment of Inertia (Single Pump Rotating Group)


Model PVH57 PVH74 PVH98 PVH131 Nm.sec2 0,0054 0,0078 0,0134 0,0210 (lb.in.sec2) (0.0475) (0.0692) (0.1189) (0.1862)

Drive data
Mounting attitude should be horizontal. See preceding page for vertical mount option. Consult your local Vickers representative if a different arrangement is required. Direction of shaft rotation, viewed at the prime mover end, must be as indicated in the model designation on the pump. See 5 in Model Codes, page 4.

Cleanliness codes for petroleum oil usage System Pressure Level Product t2000 psi 2000-3000 psi Vane pumps, fixed Vane pumps, variable Piston pumps, fixed Piston pumps, variable Directional valves Proportional valves Servo valves Pressure/Flow controls Cylinders Vane motors Axial piston motors Radial piston motors 20/18/15 18/16/14 19/17/15 18/16/14 20/18/15 17/15/12 16/14/11 19/17/14 20/18/15 20/18/15 19/17/14 20/18/14 19/17/14 17/15/13 18/16/14 17/15/13 20/18/15 17/15/12 16/14/11 19/17/14 20/18/15 19/17/14 18/16/13 19/17/13

3000+ psi 18/16/13 17/15/13 16/14/12 19/17/14 15/13/11 15/13/10 19/17/14 20/18/15 18/16/13 17/15/12 18/16/13

26

Weights, Ordering, Installation/Start-up


Weights in kg (lb)*
Pump Size PVH57 Basic Thru-drive Pump Pump SAE A 3036 31-37 (66-79) (68-82) PVH74 39-45 42-48 (86-99) (93-106) PVH98 43-49 44-50 (95-108) (97-110) PVH131 60-66 62-68 (132-145) (137-150) DGMC-3-AT-BT (plus DG4V-3-0A directional valve) for remotely and electrically selected dual-pressure compensation. C175-F-20 (plus blanking plate DGMA-3-B-11 and tapping plate DGMA-T2-20-S) for remote control of pressure compensation. CVGC-3-S12 for non-remote control of pressure compensation. DGMC-3-PT-FW-30 crossline relief module (with blanking plate DGMA-3-B-11) for non-remote control of pressure compensation. Contact your Vickers representative for additional information on the application and ordering of relief valves.

*Approximate dry weights. Weight for a given model depends upon the type of pump control selected.

Ordering Procedure
Order PVH pumps by the full model designation. Pump displacement, mounting flange type, direction of rotation, pump configuration, shaft end type, shaft seals, pressure adjustment range, specific control functions, and torque limiter settings are all specified in the full model code. Various Vickers relief valves are suitable for use with the IC compensator and must be ordered separately. Examples include: DGMC2-3-AT-BT (plus DG4V-3-8C directional valve) for remotely and electrically controlled dual-pressure compensation, and standby no-flow pump operation in the load sensing mode. DGMC-3-PT-FW-30 crossline relief module (with DG4V3-8C directional valve) for electrical selection of dual pressure compensation. ECGF-02-9-21 proportional relief valve, with feedback, for remote control of pressure compensation. ECG-02-9-30 proportional relief valve for remote control of pressure compensation.

Installation and Start-up


The installation of PVH pumps must be in accord with the data on pages 14 and 23. Before the pump is started, fill the case through the uppermost drain port with hydraulic fluid of the type to be used.The case drain line must be connected directly to the reservoir and terminate below the oil level. If the pump has the vertical-mount option, attach a secondary drain line as noted on page 25. Maximum continuous pressure at the case drain port must not exceed 0,5 bar (7 psi). For multiple pump arrangements that include non-PVH sections, the requirements of the non-PVH units must be considered.

27

You might also like