De Super Heater
De Super Heater
B
G
C
1/2" BSP DRAIN TAPPING
DATA TABLE
The diffuser plate prevents any water droplets adhering to the
side of the pipe from escaping downstream. It also ensures
excellent fluid mixing of the steam and water vapour so
eliminating any risk of stratification and thus permitting the use
of sensitive and accurate controls.
INSTALLATION
The drawing below shows the equipment supplied by Auld.
Items shown but not supplied are the small bore piping and
the air filter regulators. The filter regulators are recommended
because the majority of instrument faults are traced to dirt.
Equipment not shown but should be considered include stop
valves, strainer and steam trap (essential) and safety valve.
The water must be supplied at approximately 45 psi above the
outlet pressure of the steam valve. It is recommended that the
whole system be duplicated in continuous process plants.
Valve size
10"
12"
C/L to bottom
22"
C/L to top
26"
9"
Chamber
(approx)
20"
20"
28
58
2"
2"
3"
4"
6"
8"
33"
38"
38"
38"
14"
17"
22"
24"
30"
20"
24"
30"
36"
42"
48"
80
120
210
380
520 700
11" 11"
SIZING
The data table shows the rated Cv for the
A100 Desuperheater valve. It is essential that
sizing is confirmed by Auld. The following
information is necessary: