MBR 20100
MBR 20100
MBR 20100
C 01/07
MBRB20...CTPbF
MBR20...CT-1PbF
SCHOTTKY RECTIFIER
20 Amp
IF(AV) = 20Amp
VR = 80/ 100V
Description/ Features
Values
Units
20
20
80/90/100
IFSM @ tp = 5 s sine
850
VF
@ 10 Apk, TJ = 125C
0.70
TJ
range
- 65 to 150
@ TC = 133C
(Per Leg)
VRRM
This center tap Schottky rectifier has been optimized for low
reverse leakage at high temperature. The proprietary barrier
technology allows for reliable operation up to 150 C junction
temperature. Typical applications are in switching power
supplies, converters, free-wheeling diodes, and reverse battery protection.
150 C TJ operation
Case Styles
MBRB20...CTPbF
MBR20...CT-1PbF
Base
Common
Cathode
Base
Common
Cathode
Anode
2
Common
Cathode
D2PAK
www.irf.com
Anode
Anode
2
Common
Cathode
Anode
TO-262
1
Voltage Ratings
Parameters
MBRB2080CTPbF
MBR2080CT-1PbF
MBRB2090CTPbF
MBR2090CT-1PbF
MBRB20100CTPbF
MBR20100CT-1PbF
80
90
100
VR
Max. DC Reverse Voltage (V)
VRWM Max. Working Peak Reverse Voltage (V)
Values
Units
10
20
20
850
150
Conditions
0.5
EAS
24
mJ
Values
Units
0.80
@ 10A
0.95
@ 20A
TJ = 25 C, IAS = 2 Amps, L = 12 mH
Electrical Specifications
Parameters
VFM
IRM
0.70
@ 10A
0.85
@ 20A
0.10
mA
TJ = 25 C
mA
TJ = 125 C
TJ = TJ max.
(1)
VF(TO) Threshold Voltage
Conditions
TJ = 25 C
TJ = 125 C
Rated DC voltage
0.433
rt
15.8
CT
400
pF
LS
8.0
nH
10000
V/ s (Rated VR)
(1) Pulse Width < 300s, Duty Cycle <2%
Thermal-Mechanical Specifications
Values
Units
TJ
Parameters
Max. Junction Temperature Range
-65 to 150
Tstg
-65 to 175
Conditions
2.0
C/W DC operation
0.50
Approximate Weight
Mounting Torque
Marking Device
50
2 (0.07)
Min.
6 (5)
Max.
12 (10)
C/W DC operation
For D2Pak and TO-262
g (oz.)
Kg-cm Non-lubricated threads
(Ibf-in)
MBRB20...CT
MBR20...CT-1
www.irf.com
100
10
TJ = 150C
125C
100C
0.1
75C
50C
0.01
25C
0.001
TJ = 150C
TJ = 125C
0.0001
TJ = 25C
20
40
60
80
100
10
100
1
0.2
0.4
0.6
0.8
1.2
1.4
1.6
1.8
TJ = 25C
100
10
20
40
60
80
100
10
D = 0.75
D = 0.50
D = 0.33
D = 0.25
D = 0.20
PDM
t1
0.1
Notes:
Single Pulse
(Thermal Resistanc e)
0.01
0.00001
0.0001
0.001
t2
1. Duty factor D = t 1/ t 2
2. Peak TJ = PDM x Z thJC+ TC
0.01
0.1
10
www.irf.com
140
150
DC
130
Square wave (D = 0.50)
Rated VR applied
120
110
D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75
DC
RMSLimit
100
10
12
14
16
10
12
14
16
1000
At Any Rated Load Condition
And With Rated VRRM Applied
Following Surge
100
10
100
1000
10000
www.irf.com
Outlines Table
www.irf.com
INTERNATIONAL
RECTIFIER
LOGO
PART NUMBER
MBRB20100CT
DATE CODE
ASSEMBLY
LOT CODE
TO-262
EXAMPLE: THIS IS A MBR20100CT-1PbF
LOT CODE 1789
ASSEMBLED ON WW 19, 1999
INTERNATIONAL
RECTIFIER
LOGO
ASSEMBLY
LOT CODE
YEAR 0 = 2000
WEEK 02
P = LEAD-FREE
PART NUMBER
DATE CODE
YEAR 9 = 1999
WEEK 19
P = LEAD-FREE
www.irf.com
MBR
1
20
100
yB
= D2Pak
y none = TO-262
CT
-1
TRL
6 none
6 = -1
80 = 80V
Voltage Ratings
90 = 90V
CT
100 = 100V
6
7
y none = D2Pak
2 =B
y -1
2 none
= TO-262
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 01/07
www.irf.com