Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Micromasters en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 99

Catalog DA 51.

2 October 2002

micromaster
MICROMASTER 410/420/430/440
Inverters
0.12 kW to 250 kW

Trademarks / Internet
COMBIMASTER,

MICROMASTER, MIDIMASTER, SIMOVIS,


SITOR and SIVOLT are Siemens registered trademarks.
All other products and system names in this catalog are
(registered) trademarks of their respective owners and must be
treated accordingly.

s
MICROMASTER
410/420/430/440
Inverters

Overview

MICROMASTER 410
0.12 kW to 0.75 kW

0.12 kW to 250 kW
Catalog DA 51.2 2002
with Changes October 2002
Supersedes: Catalog DA 51.2 2001

MICROMASTER 420
0.12 kW to 11 kW

MICROMASTER 430
7.5 kW to 90 kW

MICROMASTER 440
0.12 kW to 250 kW

Appendix

The products and systems


referred to in this catalog are
marketed with a DQS certified
management system.

The DQS certificate is recognized in all IQ Net countries.


DQS certified according to
DIN EN ISO 9001 Reg. No. 357 QM
DIN EN ISO 14001 Reg. No. 81342-01
BSI certified according to
BS EN ISO 9001 Reg. No. FM 25845
Siemens AG 2002

Management system

0
1
2
3
4
A

MICROMASTER 410/420/430/440
Overview

Guidelines

MICROMASTER 410

MICROMASTER 420

The low-priced

The universal

for variable speeds with three-phase


motors on single-phase networks,
e.g. with pumps, fans, billboards, cabinets,
gate drives and automatic machines

for three-phase networks and optional


fieldbus interfacing,
e.g. for conveyor belts, material transport,
pumps, fans and machine tools

Power ranges

0.12 kW to 0.75 kW

0.12 kW to 11 kW

Voltage ranges

100 V to 120 V 1 AC
200 V to 240 V 1 AC

200 V to 240 V 1 AC
200 V to 240 V 3 AC
380 V to 480 V 3 AC

Control

V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)

V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)

Process control

Internal PI controller

Inputs

3 digital inputs
1 analog Input

3 digital inputs
1 analog input

Outputs

1 relay output

1 analog output
1 relay output

Interfacing to automation
system

The PLC partner for LOGO! and


SIMATIC S7-200

The ideal partner for your automation tasks,


whether with SIMATIC S7-200, SIMATIC S7-300/400 (TIA)
or SIMOTION

Additional features

Natural ventilation (no fan unit)


Position of connections as with
conventional switching elements
(e.g. contactors)

BICO technology

Section 1

Section 2

Main areas of application

0/2

Siemens DA 51.2 October 2002

MICROMASTER 410/420/430/440
Overview

MICROMASTER 430

MICROMASTER 440

The specialist for pumps and fans

The all-purpose

with optimized OP (manual/automatic switchover),


matched software functionality and
optimized power efficiency

with advanced vector control (with and without encoder feedback)


for versatile applications in sectors such as conveying systems,
textiles, elevators, hoisting gear and machine construction

7.5 kW to 90 kW

0.12 kW to 250 kW

380 V to 480 V 3 AC

200 V to 240 V 1 AC
200 V to 240 V 3 AC
380 V to 480 V 3 AC
500 V to 600 V 3 AC

V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)

V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
FCC (flux current control)
Vector control

Internal PID controller

Internal PID controller


(autotuning)

6 digital inputs
2 analog inputs
1 PTC/KTY input

6 digital inputs
2 analog inputs
1 PTC/KTY input

2 analog outputs
3 relay outputs

2 analog outputs
3 relay outputs

The ideal partner for your automation tasks,


whether with SIMATIC S7-200, SIMATIC S7-300/400 (TIA)
or SIMOTION

The ideal partner for your automation tasks,


whether with SIMATIC S7-200, SIMATIC S7-300/400 (TIA)
or SIMOTION

Low-energy mode
Load torque monitoring
(detects running dry of pumps)
Motor staging

3 selectable drive data sets


Integrated brake chopper (up to 75 kW)
Torque control

Section 3

Section 4
Siemens DA 51.2 October 2002

0/3

MICROMASTER 410/420/430/440
Overview

Options

Various options are available


for the MICROMASTER:
Filters
Chokes
Operator panels
PROFIBUS module
DeviceNet module
Pulse encoder evaluation
module
Gland plates
Mounting kits, etc.

Assignment of operator panels and modules to the converter ranges


Accessories

Order No.
410

MICROMASTER
420
430

440

%
%

%
%

Operator panels
OP
BOP
AOP
BOP-2

6SE6400-0SP00-0AA0
6SE6400-0BP00-0AA0
6SE6400-0AP00-0AA1
6SE6400-0BE00-0AA0

Modules
PROFIBUS
DeviceNet
Pulse encoder evaluation

6SE6400-1PB00-0AA0
6SE6400-1DN00-0AA0
6SE6400-0EN00-0AA0

%
%

%
%

% Possible combination

BOP/OP

AOP

BOP-2

DeviceNet

Pulse encoder evaluation

Operator panels

PROFIBUS
Modules

0/4

Siemens DA 51.2 October 2002

%
%
%

Inverter
MICROMASTER 410
1/2

Description

1/4

Circuit Diagrams

1/6

Technical Data

1/7

Selection and Ordering Data

1/8

Options

1/10

Dimension Drawings

Siemens DA 51.2 October 2002

1/1

MICROMASTER 410
Description

1
Frame size AA

Applications
The MICROMASTER 410
inverter is suitable for a variety
of variable-speed drive applications.
It is especially suitable for use
with pumps and fans, as a
drive in various sectors, e.g.
food, textile and packaging
industries, as well as for
conveyor systems, factory
gate and garage door drives,
and as a universal drive for
moving billboards.

Frame size AB

Design
The MICROMASTER 410 has
a compact design.
Heat sinks provide natural
cooling for the inverter. A fan
unit is not used.
The position of the connections has been selected as for
conventional contactors.
The operator panel available
as an option can be easily
fitted without requiring any
tools.

It is the ideal low-cost frequency inverter solution for


the bottom performance
range of the MICROMASTER
family.
The inverter is especially
characterized by its customeroriented performance and
ease of use.
Versions for connection to
230-V and 115-V single-phase
networks enable it to be used
all over the world.

Main Characteristics
Simple selection from

1/2

Siemens DA 51.2 October 2002

minimum range of types


(only few options)
Compact design
Natural cooling with heat
sinks (no fan unit)
Simple connection similar
to conventional switching
elements (e.g. contactors)
Version with internal EMC
filter Class B
Fast, simple commissioning with input of only a few
parameters (fast commissioning mode)
Integral RS-485 communications interface
Three programmable
digital inputs, non-floating
(the analog input can be
used as a 4th digital input)
One analog input
(0 V to 10 V)
One programmable
relay output
(30 V DC/5 A resistive;
250 V AC/2 A inductive)
Low-noise motor operation
resulting from high pulse
frequency
Integral protection for motor
and inverter.

Options (Overview)
Line commutating chokes
Adapter for standardized

mounting on DIN rails


OP operator panel for

parameterizing an inverter
PC connection set
PC commissioning tool.

International Standards
The MICROMASTER 410

inverter complies with the


requirements of the EU lowvoltage guideline; filtered
versions also comply with
the EU EMC guideline
The MICROMASTER 410
inverter has the > marking
u and cu listed

c-tick
Note:
See Appendix for standards.

MICROMASTER 410
Description

Mechanical Features

Performance Features

Compact design

Latest IGBT technology

Heat dissipation through

Digital microprocessor

self-ventilation (convection)
Operating temperature
-10 C to +50 C
Easy cable connection,
mains and motor connections are separated for
optimum electromagnetic
compatibility and clear
connection
Detachable, optional
operator panels
Screwless control terminals
Side mounting possible,
thus also usable with low
cabinet depth.

control
Linear V/f characteristic,
with programmable voltage
boosting
Quadratic V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
Flying restart
Automatic restart facility
following power failure or
fault
Programmable acceleration (0 s to 650 s) with ramp
smoothing
Fast current limit (FCL) for
trip free operation

Protection Features
Fast, repeatable digital

input response time


Fine speed adjustment
using a high resolution
10-bit analog input
One skip frequency
Removable Y capacitor
for use on IT mains supplies
Serial RS-485 interface with
USS protocol
LED for status information
Versions with internal EMC
filter Class B.

Overload current 1.5 x

rated output current


(i.e. 150 % overload
capability) for 60 s, then
0.85 x rated output current
for 240 s, cycle time 300 s
Overvoltage/undervoltage
protection
Inverter overtemperature
protection
Earth fault protection
Short circuit protection
I2t motor thermal protection
Stall prevention.

Siemens DA 51.2 October 2002

1/3

MICROMASTER 410
Circuit Diagrams

General Circuit Diagram


Operator panel (Option)

I
O

Fn
Jog

100 V to 120 V 1 AC
200 V to 240 V 1 AC
PE
FS1

Voltage supply and


analog input
Input voltage: 0 V to + 10 V,
scalable

+ >
- 4.7 k
-

AIN+

+10 V

max. 33 V
max. 5 mA
1

DIN1
DIN2

DIN3

+
24 V
-

4
5

Voltage supply
(external or
internal source)

Output relay contacts


250 V AC, max. 2 A
(inductive load)
30 V DC, max. 5 A
(resistive load)

L, N

PE

AC

DC

0V

RL1-C

P+
N-

DC -

CPU

RL1
RL1-B

DC+

+24 V (max. 50 mA)

11

DC

12

AC

9
10

Serial
interface
RS-485
PE

U, V, W
A DA51-5033b

M
3~
For an additional digital input (DIN 4) external
connections should be made:
DIN4

+
24 V
-

7
4
5

Voltage supply
(external or
internal source)
ADA51-5034b

1/4

Siemens DA 51.2 October 2002

MICROMASTER 410
Circuit Diagrams

Terminal Connection Diagram


Mains connections

1
View A

Motor connections

A DA51-5035a

View A

Output relay
RL1

RL1-B

RL1-C

11

12

Output relay contacts

DIN1
1

DIN2

DIN3

+24V

0V

+10V

AIN+

0V

P+

N-

10

RS-485

(USS protocol)

Digital inputs

Voltage
supply 24 V

Analog input
Voltage
supply 10 V

Siemens DA 51.2 October 2002

1/5

MICROMASTER 410
Technical Data

MICROMASTER 410 inverter


Input voltage and
power ranges
Input frequency
Output frequency
Power factor
Inverter efficiency
Overload capability
Inrush current
Control method
PWM frequency

Fixed frequencies
Skip frequency bands
Setpoint resolution
Digital inputs
Analog inputs
Relay outputs
Serial interfaces
Motor cable length
Electromagnetic compatibility
Braking
Protection level
Temperature range
Storage temperature
Humidity
Operational altitudes
Protection features for

Conformity with standards


> marking
Dimensions and weights
(without options)

200 V to 240 V 1 AC 10 %
0.12 to 0.75 kW
100 V to 120 V 1 AC 10 %
0.12 to 0.55 kW
47 to 63 Hz
0 Hz to 650 Hz
0.95
96 % to 97 %
Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s;
then 0.85 x rated output current for 240 s, cycle time 300 s
less than rated input current
linear V/f; quadratic V/f; multipoint characteristic (programmable V/f)
8 kHz (standard)
2 kHz to 16 kHz (in 2 kHz steps)
3, programmable
1, programmable
10 bit analog
0.01 Hz serial
3 programmable digital inputs, non-floating; PNP, SIMATIC-compatible
1, for setpoint (0 V to 10 V, scaleable or for use as 4th digital input)
1, configurable 30 V DC/5 A (resistive), 250 V AC/2 A (inductive)
RS-485, for operation with USS protocol
max. 30 m (shielded)
max. 50 m (unshielded)
Inverter available with internal EMC filter to EN 61 800-3
(defined limits to EN 55 011, Class B)
DC Braking, Compound Braking
IP 20
10 C to +50 C
40 C to +70 C
95 % (non-condensing)
up to 1000 m above sea level without derating
under-voltage
over-voltage
overload
earth faults
short circuits
stall prevention
I2t motor thermal protection
motor over-temperature

u, cu, >, c-tick


Conformity with EC low voltage directive 73/23/EC
filtered versions also with electromagnetic compatibility directive 89/336/EC
Frame size (FS)
H x W x D (mm)
Weight, approx. (kg)
AA
150 x 69 x 118
0.8
AB
150 x 69 x 138
1.0

Derating Data
Pulse frequency
Rated output
kW
0.12
0.25
0.37
0.55
0.55, 115 V (at 50 C)
0.55, 115 V (at 40 C)
0.75 (at 50 C)
0.75 (at 40 C)

Rated output current in A


for a pulse frequency of
4 kHz
6 kHz
0.9
0.9
1.7
1.7
2.3
2.3
3.2
3.2
3.0
3.0
3.2
3.2
3.9
3.9
4.2
4.2

8 kHz
0.9
1.7
2.3
3.2
2.7
3.2
3.6
4.2

10 kHz
0.8
1.5
2.0
2.9
2.5
2.9
3.2
3.8

The current data apply to an ambient temperature of 50 C unless specified otherwise.

1/6

Siemens DA 51.2 October 2002

12 kHz
0.7
1.3
1.7
2.6
2.2
2.6
2.9
3.4

14 kHz
0.6
1.1
1.5
2.3
2.0
2.3
2.6
3.0

16 kHz
0.5
0.9
1.3
2.0
1.7
2.0
2.3
2.7

MICROMASTER 410
Technical Data

Derating Data (continued)


Installation height above sea level
Permissible output current
in % of the rated output current

Permissible mains voltage


in % of the max. possible mains voltage

ADA51-5039a

ADA51-5038a

100
%
80
75
60

Mains voltage

Rated output current

100
90
80
%
60
40

40

20

20

1000

2000

3000 m 4000
Operational altitude

1000

2000

3000 m 4000

Operational altitude

Selection and Ordering Data

MICROMASTER 410 Inverter


Rated
output
kW

hp

Rated input
current 1)

Rated output
current

Frame size

Order No.

(FS)

MICROMASTER 410
without filter

MICROMASTER 410
with internal filter Class B

Mains operating voltage 100 V to 120 V 1 AC, output voltage 200 V to 240 V 3 AC
0.12
0.25
0.37
0.55

0.16
0.33
0.50
0.75

4.6
7.5
10.1
13.4

0.9
1.7
2.3
2.7 (3.2 at 40 C)

AA
AA
AA
AB

6SE6410-2UA11-2AA0
6SE6410-2UA12-5AA0
6SE6410-2UA13-7AA0
6SE6410-2UA15-5BA0

Mains operating voltage 200 V to 240 V 1 AC, output voltage 200 V to 240 V 3 AC
0.12
0.25
0.37
0.55
0.75

0.16
0.33
0.50
0.75
1.0

1.5
3.0
4.4
5.8
7.8

0.9
1.7
2.3
3.2
3.6 (4.2 at 40 C)

AA
AA
AA
AB
AB

6SE6410-2UB11-2AA0
6SE6410-2UB12-5AA0
6SE6410-2UB13-7AA0
6SE6410-2UB15-5BA0
6SE6410-2UB17-5BA0

6SE6410-2BB11-2AA0
6SE6410-2BB12-5AA0
6SE6410-2BB13-7AA0
6SE6410-2BB15-5BA0
6SE6410-2BB17-5BA0

The current data apply to an ambient temperature of 50 C unless specified otherwise.

See Appendix for note on


ordering.
All MICROMASTER 410
inverters are supplied without
an operator panel (OP). An OP
or other options have to be
ordered additionally (see
page 1/9).

Motors for

MICROMASTER 410
Catalog M 11 contains selection and ordering data for
motors which are particularly
suitable for operation with the
MICROMASTER 410 inverters
(see Appendix for overview).

1) The values apply to rated mains


voltages of 115 V or 230 V.
Siemens DA 51.2 October 2002

1/7

MICROMASTER 410
Options

Variant Dependent Options


EMC filter, Class B
Variants with internal EMC
filter Class B are available for
inverters with a mains operating voltage of 230 V 1 AC.

The requirements are fulfilled using shielded cables


with a max. length of 5 m,
or 10 m with a low-capacitance motor cable (core/
core < 75 pF/m, core/shield
< 150 pF/m).
The limits comply with
EN 55 011 Class B.

An inverter with internal filter


can be used with a 30-mA
residual current operated circuit-breaker, and is only suitable for hardwired installation.
A non-filtered inverter together
with the optional filter Filter
Class B with low leakage currents has a leakage current
3.5 mA (shielded motor
cable up to 5 m).

Line commutating choke


Line commutating chokes are
used to smooth voltage peaks
or to bridge commutating
dips.
In addition, line commutating
chokes reduce the effects of
harmonics on the inverter and
the power supply.
If the ratio of inverter rated
power to netwerk short-circuit
power is less than 1 %, a line
commutating choke must be
used in order to reduce the
current peaks.
The line commutating chokes
are designed as footprint
chokes and are fitted between
the inverter and the mounting
plate.

In line with the EN 61 000-3-2


regulations Limits for harmonic currents with device
input current 16 A per
phase, there are special
aspects for drives with 250 W
to 550 W and 230-V singlephase supplies which can be
used in non-industrial applications (1st environment).

For devices with 250 W and


370 W it is necessary either to
fit the recommended input
chokes or to apply to the
power utility company for
authorization to connect the
devices to the public power
supply.
No limits are currently defined
in the EN 61 000-3-2 standard
for professionally used
devices with a connected load
> 1 kW. This means that the
inverters with an output power
0.75 kW comply with the
EN 61 000-3-2 standard.

Variant Independent Options


Operator Panel (OP)

Connection set for


PC to inverter

With the OP, individual parameter settings can be made.

For controlling and commissioning an inverter directly


from a PC if the appropriate
software has been installed
(e.g. STARTER).

Values and units are shown on


a 5-digit display.
An OP can be used for several
inverters. It is directly plugged
into the inverter.

The connection set includes


an RS-485/RS-232 interface
converter with a 9-pin Sub-D
connector.

Inverter with Operator Panel (OP)

1/8

Siemens DA 51.2 October 2002

Commissioning tools
STARTER
Starter is graphic start-up
software for guided commissioning for MICROMASTER
410/420/430/440 frequency
inverters under Windows
NT/2000. Parameter lists
can be read out, altered,
stored, entered and printed.
DriveMonitor
DriveMonitor is start-up
software for list-oriented
programming of frequency
inverters under Windows
95/98/NT/2000.

MICROMASTER 410
Options

Ordering Data for Variant Dependent Options


The options listed here
(filters, chokes, fuses and
circuit breakers) are inverter
specific.

Mains
operating
voltage

100 V to
120 V 1 AC

200 V to
240 V 1 AC

200 V to
240 V 1 AC

Rated
output

The inverter and the associated options have the same


voltage ratings.

Inverter
without filter

All variant dependent


options and the operator
panel are certified to u,
except fuses. The fuses of
type 3NA3 are recommended for Europe.

Use in America requires


u-listed fuses such as e.g. the
Class NON range from
Bussmann.

Order No. of the options

kW
0.12

6SE6410-2UA11-2AA0

Filter Class B
with low leakage
currents

0.25

6SE6410-2UA12-5AA0

0.37

6SE6410-2UA13-7AA0 *)

0.55

6SE6410-2UA15-5BA0 *)

0.12

6SE6410-2UB11-2AA0

6SE6400-2FL01-0AB0

0.25

6SE6410-2UB12-5AA0

0.37

6SE6410-2UB13-7AA0

0.55

6SE6410-2UB15-5BA0

0.75

6SE6410-2UB17-5BA0

0.12

Inverter
with internal filter Class B
6SE6410-2BB11-2AA0

0.25

6SE6410-2BB12-5AA0

0.37

6SE6410-2BB13-7AA0

0.55

6SE6410-2BB15-5BA0

0.75

6SE6410-2BB17-5BA0

Line commutating
choke
6SE6400-3CC01-0AB0

Fuse
(see Catalog
NS K)
3NA3803

Circuit-breaker
(see Catalog
NS K)
3RV1021-1GA10

6SE6400-3CC02-6BB0

3NA3805

3RV1021-1KA10

3NA3807

3RV1021-4AA10

6SE6400-3CC00-4AB0

3NA3803

3RV1021-1BA10

3RV1021-1JA10

3RV1021-1EA10
6SE6400-3CC01-0AB0

3RV1021-1FA10
3RV1021-1HA10

6SE6400-3CC00-4AB0

3NA3805

3RV1021-1JA10

3NA3803

3RV1021-1BA10
3RV1021-1EA10

6SE6400-3CC01-0AB0

3RV1021-1FA10
3RV1021-1HA10
3NA3805

3RV1021-1JA10

*) With these inverters, the choke cannot be mounted in the substructure; it must be mounted upright.

Ordering Data for Variant Independent Options


The options listed here
are suitable for all
MICROMASTER 410 Inverters.
Options
Operator Panel (OP)
Connection set for PC to inverter
Adapter for mounting on DIN rail
Start-up tools STARTER and DriveMonitor,
as well as multilanguage documentation on CD-ROM

Order No.
6SE6400-0SP00-0AA0
6SE6400-0PL00-0AA0
6SE6400-0DR00-0AA0
6SE6400-5EA00-1AG0

Documentation
Type of documentation
Operating instructions 1)
(paper version)

Parameter list 1)
(paper version)

Getting Started Guide 1)


(paper version),
included with every inverter

Language
German
English
French
Italian
Spanish
German
English
French
Italian
Spanish
Multilanguage

Order No.
6SE6400-5EA00-0AP0
6SE6400-5EA00-0BP0
6SE6400-5EA00-0DP0
6SE6400-5EA00-0CP0
6SE6400-5EA00-0EP0
6SE6400-5EB00-0AP0
6SE6400-5EB00-0BP0
6SE6400-5EB00-0DP0
6SE6400-5EB00-0CP0
6SE6400-5EB00-0EP0

1) Available on Internet at
http://www.siemens.com/
micromaster.
Siemens DA 51.2 October 2002

1/9

MICROMASTER 410
Dimension Drawings

12
(0.47)

150 (5.9)
(5 138
.4
3)

160 (6.30)

4.5
(0.18)

(4 118
.6
5)

150 (5.9)
160 (6.30)

A DA51-5036a

4.5
(0.18)

ADA51-5037a

12
(0.47)

MICROMASTER 410 Inverter

69
(2.72)

69
(2.72)

Inverter frame size AA


6SE6410-2 . . 11-2AA0
6SE6410-2 . . 12-5AA0
6SE6410-2 . . 13-7AA0

Inverter frame size AB


6SE6410-2 . . 15-5BA0
6SE6410-2 . . 17-5BA0
All dimensions in mm (values in brackets are in inches)

Line commutating chokes

Footprint chokes
6SE6400-3CC00-4AB0
6SE6400-3CC01-0AB0

70
(2.76)

149
(5.87)

ADA51-5041b

(2.87)

213 (8.39)

73

ADA51-5040b

200 (7.87)

50
(1.97)

Chokes for upright mounting


6SE6400-3CC02-6BB0

All dimensions in mm (values in brackets are in inches)

1/10

Siemens DA 51.2 October 2002

Inverter
MICROMASTER 420
2/2

Description

2/4

Circuit Diagrams

2/6

Technical Data

2/8

Selection and Ordering Data

2/9

Options

2/16

Dimension Drawings

Siemens DA 51.2 October 2002

2/1

MICROMASTER 420
Description

2
Applications
The MICROMASTER 420
inverter is suitable for a variety
of variable-speed drive
applications. It is especially
suitable for applications for
pumps, fans and conveyor
systems.
It is especially characterized
by its customer-oriented
performance and ease of use.
Its large supply-voltage range
enables it to be used all over
the world.

Main Characteristics

2/2

International Standards

EMC filters Class A/B

The MICROMASTER 420

Modular construction

Line commutating chokes

inverter complies with the


requirements of the EU lowvoltage guideline; filtered
versions also comply with
the EU EMC guideline
The MICROMASTER 420
inverter has the > marking
u and cu listed

c-tick

Design
The MICROMASTER 420 has
a modular design. The operator panels and communications modules can be easily
exchanged without requiring
any tools.

Options (Overview)

Simple commissioning

allows maximum configuration flexibility


Three fully programmable
isolated digital inputs
One scalable analog input
(0 V to 10 V) can also be
used as a 4th digital input
One programmable analog
output (0 mA to 20 mA)
One fully programmable
relay output
(30 V DC/5 A, resistive
250 V AC/2 A, inductive)
Silent motor operation is
selectable when using high
switching frequencies,
adjustable (observe derating if necessary)
Complete inverter and
motor protection.

Siemens DA 51.2 October 2002

Output chokes
Gland plates
BOP basic operator panel

for parameterizing an
inverter
AOP advanced operator
panel with plain-text and
multilingual display
Communications modules
PROFIBUS
DeviceNet
PC connection kits
Assembly kits for mounting
the operator panels in the
control cabinet doors
PC commissioning tools,
running under Windows
95/98 and NT/2000.

Note:
See Appendix for standards.

MICROMASTER 420
Description

Mechanical Features

Performance Features

Modular design

Latest IGBT technology

Operating temperature:

Digital microprocessor

10 C to +50 C
Compact housing as a
result of high power density
Easy cable connection,
mains and motor connections are separated for
optimum electromagnetic
compatibility
Detachable operator
panels
Screwless control terminals.

control
Flux current control (FCC)
for improved dynamic
response and optimized
motor control
Linear V/f characteristic
Quadratic V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
Flying restart
Slip compensation
Automatic restart facility
following power failure or
fault
PI feedback for simple
process control.

Protection Features
Programmable accelera-

tion/deceleration,
0 s to 650 s
Ramp smoothing
Fast current limit (FCL) for
trip free operation
Fast, repeatable digital
input response time
Fine speed adjustment
using a high resolution
10 bit analog input
Compound braking for
rapid controlled braking
Four skip frequencies
Removable Y capacitor
for use on IT mains supplies
(with non-grounded mains
supplies, the Y capacitor
must be removed, and an
output choke installed).

Overload current 1.5 x

rated output current


(i.e. 150 % overload capability) for 60 s, cycle time
300 s
Overvoltage/undervoltage
protection
Inverter overtemperature
protection
Motor protection using PTC
via digital input (possible
with supplementary circuit)
Earth fault protection
Short circuit protection
I2t motor thermal protection
Locked motor protection
Stall prevention
Parameter interlock.

Siemens DA 51.2 October 2002

2/3

MICROMASTER 420
Circuit Diagram

General Circuit Diagram


O p e r a to r p a n e l ( O p tio n )

2 0 0 V to 2 4 0 V 1 /3 A C
3 8 0 V to 4 8 0 V 3 A C
P E
V o lta g e s u p p ly a n d
a n a lo g in p u t

F S 1

In p u t v o lta g e : 0 V to + 1 0 V ,
s c a la b le

P E
1

-> 4 . 7 k 9

A IN +
3

A IN 4

A
D

m a x . 3 3 V
m a x . 5 m A
5

D IN 1

+ 1 0 V
0 V
2

D IN 2

D IN 3

2 4 V
8
9

tp u t re
0 V A C
d u c tiv e
V D C ,
s is tiv e

+ 2 4 V (m a x .1 0 0 m A )
0 V ( is o la te d )

R L 1

la y c o n ta c ts
, m a x . 2 A
lo a d )
m a x . 5 A
lo a d )

A n a lo g o u tp u t
0 m A to 2 0 m A

A C

D C

V o lta g e
s u p p ly

O u
2 5
( in
3 0
(re

R L 1 -B
R L 1 -C

L , N (L 1 , L 2 )
o r
L 1 , L 2 , L 3

D C L in k

C P U

D C

1 0
1 1

A C
A O U T +
A O U T -

W h e n a c o m m u n ic a tio n s
m o d u le is c o n n e c te d , th e
s e r ia l in t e r f a c e d o e s n 't w o r k .

P +
N -

1 2
A

1 3

1 4
1 5

S e r ia l
in te r fa c e
R S -4 8 5
U , V , W

P E

A D A 5 1 -5 0 0 3 i

3 ~
For an additional digital input (DIN4)
external connections should be made:
2
DIN4
24 V

+
-

0V

3
4

0 V (isolated)
ADA51-5004e

2/4

Siemens DA 51.2 October 2002

MICROMASTER 420
Circuit Diagram

Terminal Connection Diagram


Example frame size A

View A

DC link
connection

Mains
connection

Motor
connection

View A
AOUT+ AOUT12

13

P+

N-

14

15
Output relay
RL1

RS-485
(USS protocol)

Analog output

DIN1

DIN2

DIN3

+24 V

0 V (isolated)

RL1-B

RL1-C

10

11

Output relay contacts

Voltage
supply 24 V

+10 V

0V

AIN+

AIN-

Voltage
supply 10 V

A DA51-5006d

Digital inputs

Analog input

Siemens DA 51.2 October 2002

2/5

MICROMASTER 420
Technical Data

MICROMASTER 420 inverter


Input voltage and
power ranges
Input frequency
Output frequency
Power factor
Inverter efficiency
Overload capability
Inrush current
Control method
PWM frequency

Fixed frequencies
Skip frequency bands
Setpoint resolution

Digital inputs
Analog input
Relay output
Analog output
Serial interfaces
Motor cable length

200 V to 240 V 1 AC 10%


0.12 kW to 3 kW
200 V to 240 V 3 AC 10%
0.12 kW to 5.5 kW
380 V to 480 V 3 AC 10%
0.37 kW to 11 kW
47 Hz to 63 Hz
0 Hz to 650 Hz
0.95
96% to 97%
Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s,
cycle time 300 s
less than rated input current
linear V/f; quadratic V/f; multipoint characteristic (programmable V/f); flux current control (FCC)
16 kHz (standard with 230 V 1/3 AC)
4 kHz (standard with 400 V 3 AC)
2 kHz to 16 kHz (in 2 kHz steps)
7, programmable
4, programmable
0.01 Hz digital
0.01 Hz serial
10 bit analog
3 fully programmable isolated digital inputs; switchable PNP/NPN
1 for setpoint or PI controller (0 to 10 V, scalable or for use as 4th digital input)
1, configurable 30 V DC/5 A (resistive), 250 V AC/2 A (inductive)
1, configurable (0 mA to 20 mA)
RS-485, optional RS-232

without output choke max. 50 m (shielded)


max. 100 m (unshielded)
with output choke max. 200 m (shielded)
max. 300 m (unshielded)
Electromagnetic
Inverter available with internal EMC filter Class A;
compatibility
available as options are EMC filters to EN 55 011, Class A or Class B
Braking
DC Braking, Compound Braking
Protection level
IP 20
Temperature range
10 C to +50 C
Storage temperature
40 C to +70 C
Humidity
95% (non-condensing)
Operational altitudes
up to 1000 m above sea level without derating
Protection features for
under-voltage
over-voltage
overload
earth faults
short circuits
stall prevention
locked motor
motor over-temperature
inverter over-temperature
parameter PIN protection

Conformity with standards


u, cu, >, c-tick
> marking
Conformity with EC low voltage directive 73/23/EC;
filtered versions also with electromagnetic compatibility directive 89/336/EC
Dimensions and weights
Frame size (FS)
H x W x D (mm)
Weight, approx. (kg)
(without options)
A
173 x 73 x 149
1.0
B
202 x 149 x 172
3.3
C
245 x 185 x 195
5.0

2/6

Siemens DA 51.2 October 2002

MICROMASTER 420
Technical Data

Derating Data
Pulse frequency
Rated output
(for 400 V 3 AC)
kW
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11

Rated output current in A


for a pulse frequency of
4 kHz
6 kHz
1.2
1.2
1.6
1.6
2.1
2.1
3.0
3.0
4.0
4.0
5.9
5.9
7.7
7.7
10.2
10.2
13.2
13.2
18.4
18.4
26.0
26.0

8 kHz
1.2
1.6
2.1
2.7
2.7
5.1
5.1
6.7
13.2
13.2
17.9

10 kHz
1.2
1.6
2.1
2.7
2.7
5.1
5.1
6.7
13.2
13.2
17.9

12 kHz
1.2
1.6
1.6
1.6
1.6
3.6
3.6
4.8
9.6
9.6
13.5

14 kHz
1.2
1.6
1.6
1.6
1.6
3.6
3.6
4.8
9.6
9.6
13.5

16 kHz
1.1
1.1
1.1
1.1
1.1
2.6
2.6
3.6
7.5
7.5
10.4

Operating temperature

R a te d o u tp u t c u rre n t

A D A 5 1 -5 0 1 7 e

1 0 0
%
8 0
6 0
5 0
4 0
2 0
0

-1 0

1 0

2 0

3 0
4 0
5 0
6 0 C 7 0
O p e r a tin g te m p e r a tu r e

Installation height above sea level


Permissible output current
in % of the rated output current
ADA51-5018c

Rated output current

100
%
80
60
40
20
0

1000

2000

3000 m 4000
Operational altitude

Permissible mains voltage


in % of the max. possible mains voltage
ADA51-5019b

Mains voltage

100
%
80
77
60
40
20
0

1000

2000

3000 m 4000

Operational altitude

Siemens DA 51.2 October 2002

2/7

MICROMASTER 420
Selection and Ordering Data

MICROMASTER 420 Inverter


Rated output

kW

hp

Rated input
current 1)

Rated output
current

Frame size

Order No.
MICROMASTER 420
without filter

MICROMASTER 420
with Class A filter 2)

A
A
A
A
A
B
B
B
C

6SE6420-2UC11-2AA0
6SE6420-2UC12-5AA0
6SE6420-2UC13-7AA0
6SE6420-2UC15-5AA0
6SE6420-2UC17-5AA0
6SE6420-2UC21-1BA0
6SE6420-2UC21-5BA0
6SE6420-2UC22-2BA0
6SE6420-2UC23-0CA0

6SE6420-2AB11-2AA0
6SE6420-2AB12-5AA0
6SE6420-2AB13-7AA0
6SE6420-2AB15-5AA0
6SE6420-2AB17-5AA0
6SE6420-2AB21-1BA0
6SE6420-2AB21-5BA0
6SE6420-2AB22-2BA0
6SE6420-2AB23-0CA0

A
A
A
A
A
B
B
B
C
C
C

6SE6420-2UC11-2AA0
6SE6420-2UC12-5AA0
6SE6420-2UC13-7AA0
6SE6420-2UC15-5AA0
6SE6420-2UC17-5AA0
6SE6420-2UC21-1BA0
6SE6420-2UC21-5BA0
6SE6420-2UC22-2BA0
6SE6420-2UC23-0CA0
6SE6420-2UC24-0CA0
6SE6420-2UC25-5CA0

6SE6420-2AC23-0CA0
6SE6420-2AC24-0CA0
6SE6420-2AC25-5CA0

A
A
A
A
A
B
B
B
C
C
C

6SE6420-2UD13-7AA0
6SE6420-2UD15-5AA0
6SE6420-2UD17-5AA0
6SE6420-2UD21-1AA0
6SE6420-2UD21-5AA0
6SE6420-2UD22-2BA0
6SE6420-2UD23-0BA0
6SE6420-2UD24-0BA0
6SE6420-2UD25-5CA0
6SE6420-2UD27-5CA0
6SE6420-2UD31-1CA0

6SE6420-2AD22-2BA0
6SE6420-2AD23-0BA0
6SE6420-2AD24-0BA0
6SE6420-2AD25-5CA0
6SE6420-2AD27-5CA0
6SE6420-2AD31-1CA0

(FS)

Mains operating voltage 200 V to 240 V 1 AC


0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0

0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0

1.4
2.7
3.7
5.0
6.6
9.6
13.0
17.6
23.7

0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6

Mains operating voltage 200 V to 240 V 3 AC

0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5

0.16
0.33
0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5

0.6
1.1
1.6
2.1
2.9
4.1
5.6
7.6
10.5
13.1
17.5

0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6
17.5
22.0

Mains operating voltage 380 V to 480 V 3 AC


0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11

0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10.0
15.0

1.1
1.4
1.9
2.8
3.9
5.0
6.7
8.5
11.6
15.4
22.5

1.2
1.6
2.1
3.0
4.0
5.9
7.7
10.2
13.2
19.0
26.0

See Appendix for note on


ordering.
All MICROMASTER 420 are
supplied with a Status Display
Panel SDP. A Basic Operator
Panel BOP, Advanced Operator Panel AOP or other options
have to be ordered additionally (see pages 2/11 to 2/15).

1) The values apply to rated mains


voltages of 240 V or 400 V.

2/8

2) Use of MICROMASTER inverters with internal filter is not


permissible on non-grounded
(IT) mains supplies.

Siemens DA 51.2 October 2002

Motors for

MICROMASTER 420
Catalog M 11 contains selection and ordering data for
motors which are particularly
suitable for operation with the
MICROMASTER 420 inverters
(see Appendix for overview).

MICROMASTER 420
Options

Variant Dependent Options


EMC filter, Class A
Filter for inverters without an
internal filter, for
200 V to 240 V 3 AC,
frame sizes A and B
380 V to 480 V 3 AC,
frame size A.
All other inverters can be
supplied with an internal
Class A filter.
The requirements are fulfilled
using shielded cables with a
max. length of 25 m.

Class B filter with


low leakage currents
EMC filter for 200 V to 240 V
1 AC inverters, frame sizes A
and B, without an internal
(Class A) EMC filter.
With this filter, the inverter
complies with the emission
standard EN 55 011, Class B.
The leakage currents are
reduced to < 3.5 mA.
The requirements are fulfilled
using shielded cables with a
max. length of 5 m.

EMC filter, Class B

Leakage currents:

Filter for inverters without an


internal filter, for
200 V to 240 V 3 AC,
frame sizes A and B
380 V to 480 V 3 AC,
frame size A.

The leakage currents of the


inverters with/without filter
(internal/external) may
exceed 30 mA. Typical values
in practice are between 10 mA
and 50 mA. The exact values
depend on the design, environment and cable lengths.
Interference-free operation
with residual current operated
devices with a trigger value of
30 mA cannot be guaranteed.
However, operation with residual current operated devices
with a trigger value of 300 mA
is possible. Please refer to the
Instruction Manual for details.

With this filter, the inverter


complies with the emission
standard EN 55 011, Class B.
The requirements are fulfilled
using shielded cables with a
max. length of 25 m.
Additional EMC filter,
Class B
Obtainable for inverters with
an internal Class A EMC
filter A.
With this filter, the inverter
complies with the emission
standard EN 55 011, Class B.

Line commutating choke

Output choke

Line commutating chokes are


used to smooth voltage peaks
or to bridge commutating
dips. In addition, line commutating chokes reduce the
effects of harmonics on the
inverter and the power supply.
If the line impedance is < 1%,
a line commutating choke
must be used in order to
reduce the current peaks.

Output chokes can be


supplied for reducing the
capacitive currents and dV/dt
in the case of motor cables
> 50 m (shielded) or
> 100 m (unshielded).

In line with the EN 61 000-3-2


regulations Limits for harmonic currents with device
input current 16 A per
phase, there are special
aspects for drives with 250 W
to 550 W and 230-V singlephase supplies which can be
used in non-industrial applications (1st environment).

Gland plate
The gland plate enables
shielded connection of the
power and control cables,
ensuring optimum EMC
performance. This ensures
compliance with the NEMA 1
directive.

For devices with 250 W and


370 W it is necessary either to
fit the recommended input
chokes or to apply to the
power utility company for
authorization to connect the
devices to the public power
supply.
No limits are currently defined
in the EN 61 000-3-2 standard
for professionally used
devices with a connected load
> 1 kW. This means that the
inverters with an output power
0.75 kW comply with the
EN 61 000-3-2 standard.

The requirements are fulfilled


using shielded cables with a
max. length of 25 m.

Siemens DA 51.2 October 2002

2/9

MICROMASTER 420
Options

Variant Independent Options


Basic Operator Panel (BOP)

PROFIBUS module

With the BOP, individual


parameter settings can be
made. Values and units are
shown on a 5-digit display.

For a complete PROFIBUS


connection with up to
12 Mbaud. Remote control of
the inverter is possible with the
PROFIBUS module. Remote
control and operation at the
inverter can be combined
using an operator panel
plugged onto the PROFIBUS
module. The latter can be supplied by an external 24 V DC
power supply and is thus also
active when the inverter is disconnected from the mains.
Connection by means of a
9-pin SUB-D connector
(available as an accessory).

Basic Operator Panel (BOP)

A BOP can be used for several


inverters. It can be directly
mounted on the inverter or in a
control-cabinet door using a
mounting kit.
Advanced Operator Panel
(AOP)
The AOP enables parameter
sets to be read out of the
inverter or to be written into the
inverter (upload/download).
Different parameter sets can
be stored in the AOP. It has a
plain-text display with the possibility of switching between
several languages.

DeviceNet module
For networking the inverters to
the DeviceNet fieldbus system
widely used on the American
market. A max. transmission
rate of 500 kbaud is possible.
Remote control of the module
is possible via the DeviceNet
module. Remote control and
operation on the inverter can
be combined using an operator panel connected to the
DeviceNet module.
The connection to the
DeviceNet bus system is
made using a 5-pin connector
with terminal strip.

Connection set for


PC to inverter
For controlling an inverter
directly from a PC if the appropriate software has been
installed (e.g. STARTER) in the
PC. Isolated RS-232 adapter
board for reliable point-topoint connection to a PC.
Includes a Sub-D connector
and an RS-232 standard cable
(3 m).
Connection set for
PC to AOP
For connecting a PC to an
AOP. Offline programming of
inverters and archiving of
parameter sets possible.
Includes a desktop attachment kit for an AOP, an RS-232
standard cable (3 m) with
Sub-D connectors and a universal power supply unit.

Operator panel door


mounting kit for single
inverter
For mounting an operator
panel in a control cabinet
door. Degree of protection is
IP 56. Contains a cable
adapter board with screwless
terminals for use with the
users own cables.
AOP door mounting kit
for multiple inverter (USS)
For mounting an AOP in a
control cabinet door. Degree
of protection IP 56. The AOP
can communicate with several
inverters by means of the
RS-485 USS protocol. The
4-pin connecting cable from
the AOP to the RS-485 terminals of the inverter and to the
24 V user terminal strip is not
included.
Commissioning tools
STARTER
Starter is start-up software
for guided commissioning
for MICROMASTER
410/420/430/440 frequency
inverters under Windows
NT/2000. Parameter lists
can be read out, altered,
stored, entered and printed.
DriveMonitor
DriveMonitor is start-up
software for list-oriented
programming of frequency
inverters under Windows
95/98/NT/2000.
Both programs are included
on the Docu CD which is provided with every inverter.

Advanced Operator Panel (AOP)

Up to 30 inverters can be controlled from an AOP via USS


protocol. It can be directly
plugged into the inverter or
built into the control-cabinet
door using a mounting kit.

2/10

Siemens DA 51.2 October 2002

MICROMASTER 420
Options

Ordering Data for Variant Dependent Options


The options listed here
(filters, chokes, gland plates,
fuses and circuit breakers) are
inverter specific.
Mains operating
voltage

200 V to 240 V 1 AC

200 V to 240 V 3 AC

380 V to 480 V 3 AC

200 V to 240 V 1 AC

200 V to 240 V 3 AC

380 V to 480 V 3 AC

Rated
output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11

0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11

The inverter and the associated options have the same


voltage ratings.

Inverter
without filter

6SE6420-2UC11-2AA0
6SE6420-2UC12-5AA0
6SE6420-2UC13-7AA0
6SE6420-2UC15-5AA0
6SE6420-2UC17-5AA0
6SE6420-2UC21-1BA0
6SE6420-2UC21-5BA0
6SE6420-2UC22-2BA0
6SE6420-2UC23-0CA0
6SE6420-2UC11-2AA0
6SE6420-2UC12-5AA0
6SE6420-2UC13-7AA0
6SE6420-2UC15-5AA0
6SE6420-2UC17-5AA0
6SE6420-2UC21-1BA0
6SE6420-2UC21-5BA0
6SE6420-2UC22-2BA0
6SE6420-2UC23-0CA0
6SE6420-2UC24-0CA0
6SE6420-2UC25-5CA0
6SE6420-2UD13-7AA0
6SE6420-2UD15-5AA0
6SE6420-2UD17-5AA0
6SE6420-2UD21-1AA0
6SE6420-2UD21-5AA0
6SE6420-2UD22-2BA0
6SE6420-2UD23-0BA0
6SE6420-2UD24-0BA0
6SE6420-2UD25-5CA0
6SE6420-2UD27-5CA0
6SE6420-2UD31-1CA0
Inverter
with internal filter Class A
6SE6420-2AB11-2AA0
6SE6420-2AB12-5AA0
6SE6420-2AB13-7AA0
6SE6420-2AB15-5AA0
6SE6420-2AB17-5AA0
6SE6420-2AB21-1BA0
6SE6420-2AB21-5BA0
6SE6420-2AB22-2BA0
6SE6420-2AB23-0CA0
6SE6420-2AC23-0CA0
6SE6420-2AC24-0CA0
6SE6420-2AC25-5CA0
6SE6420-2AD22-2BA0
6SE6420-2AD23-0BA0
6SE6420-2AD24-0BA0
6SE6420-2AD25-5CA0
6SE6420-2AD27-5CA0
6SE6420-2AD31-1CA0

All options are certified


to u, except fuses.
The fuses of type 3NA3 are
recommended for Europe.

Use in America requires


u-listed fuses such as e.g.
the Class NON range from
Bussmann.

Order No. of the options


EMC filter
Class A

6SE6400-2FA00-6AD0

EMC filter
Class B

6SE6400-2FB00-6AD0

6SE6400-2FA01-4BC0

6SE6400-2FB01-4BC0

6SE6400-2FA00-6AD0

6SE6400-2FB00-6AD0

Supplementary
EMC filter Class B

6SE6400-2FS01-0AB0

6SE6400-2FS02-6BB0

6SE6400-2FS03-5CB0
6SE6400-2FS03-8CD0

6SE6400-2FS01-6BD0

6SE6400-2FS03-8CD0

Siemens DA 51.2 October 2002

2/11

MICROMASTER 420
Options

Ordering Data for Variant Dependent Options (continued)

Mains operating
voltage

200 V to 240 V 1 AC

200 V to 240 V 3 AC

2
380 V to 480 V 3 AC

200 V to 240 V 1 AC

200 V to 240 V 3 AC

380 V to 480 V 3 AC

2/12

Rated
output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11

0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11

Inverter
without filter

6SE6420-2UC11-2AA0
6SE6420-2UC12-5AA0
6SE6420-2UC13-7AA0
6SE6420-2UC15-5AA0
6SE6420-2UC17-5AA0
6SE6420-2UC21-1BA0
6SE6420-2UC21-5BA0
6SE6420-2UC22-2BA0
6SE6420-2UC23-0CA0
6SE6420-2UC11-2AA0
6SE6420-2UC12-5AA0
6SE6420-2UC13-7AA0
6SE6420-2UC15-5AA0
6SE6420-2UC17-5AA0
6SE6420-2UC21-1BA0
6SE6420-2UC21-5BA0
6SE6420-2UC22-2BA0
6SE6420-2UC23-0CA0
6SE6420-2UC24-0CA0
6SE6420-2UC25-5CA0
6SE6420-2UD13-7AA0
6SE6420-2UD15-5AA0
6SE6420-2UD17-5AA0
6SE6420-2UD21-1AA0
6SE6420-2UD21-5AA0
6SE6420-2UD22-2BA0
6SE6420-2UD23-0BA0
6SE6420-2UD24-0BA0
6SE6420-2UD25-5CA0
6SE6420-2UD27-5CA0
6SE6420-2UD31-1CA0
Inverter
with internal filter Class A
6SE6420-2AB11-2AA0
6SE6420-2AB12-5AA0
6SE6420-2AB13-7AA0
6SE6420-2AB15-5AA0
6SE6420-2AB17-5AA0
6SE6420-2AB21-1BA0
6SE6420-2AB21-5BA0
6SE6420-2AB22-2BA0
6SE6420-2AB23-0CA0
6SE6420-2AC23-0CA0
6SE6420-2AC24-0CA0
6SE6420-2AC25-5CA0
6SE6420-2AD22-2BA0
6SE6420-2AD23-0BA0
6SE6420-2AD24-0BA0
6SE6420-2AD25-5CA0
6SE6420-2AD27-5CA0
6SE6420-2AD31-1CA0

Siemens DA 51.2 October 2002

Order No. of the options


Low leakage
Class B
6SE6400-2FL01-0AB0

Line commutating
choke
6SE6400-3CC00-4AB0

Output choke
6SE6400-3TC00-4AD1

6SE6400-3CC01-0AB0

6SE6400-2FL02-6BB0

6SE6400-3CC02-6BB0

6SE6400-3TC01-0BD0

6SE6400-3CC03-5CB0
6SE6400-3CC00-3AC0

6SE6400-3TC03-2CD0
6SE6400-3TC00-4AD1

6SE6400-3CC00-4AB0

6SE6400-3CC00-5AC0

6SE6400-3CC00-8BC0
6SE6400-3CC01-4BD0

6SE6400-3TC01-0BD0

6SE6400-3CC01-7CC0
6SE6400-3CC03-5CD0

6SE6400-3TC03-2CD0

6SE6400-3CC00-2AD0

6SE6400-3TC01-0BD0
(not suitable for footprint
mounting)

6SE6400-3CC00-4AD0
6SE6400-3CC00-6AD0
6SE6400-3CC01-0BD0

6SE6400-3TC01-0BD0

6SE6400-3CC01-4BD0
6SE6400-3CC02-2CD0

6SE6400-3TC03-2CD0

6SE6400-3CC03-5CD0

6SE6400-3TC00-4AD1

6SE6400-3CC01-0AB0

6SE6400-3CC02-6BB0

6SE6400-3TC01-0BD0

6SE6400-3CC03-5CB0
6SE6400-3CC01-7CC0
6SE6400-3CC03-5CD0

6SE6400-3TC03-2CD0
6SE6400-3TC03-2CD0

6SE6400-3CC01-0BD0

6SE6400-3TC01-0BD0

6SE6400-3CC01-4BD0
6SE6400-3CC02-2CD0

6SE6400-3TC03-2CD0

6SE6400-3CC03-5CD0

MICROMASTER 420
Options

Ordering Data for Variant Dependent Options (continued)

Mains operating
voltage

Rated
output

Inverter
without filter

Order No. of the options


Gland plate

200 V to 240 V 1 AC

200 V to 240 V 3 AC

380 V to 480 V 3 AC

200 V to 240 V 1 AC

200 V to 240 V 3 AC

380 V to 480 V 3 AC

kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11

0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11

6SE6420-2UC11-2AA0
6SE6420-2UC12-5AA0
6SE6420-2UC13-7AA0
6SE6420-2UC15-5AA0
6SE6420-2UC17-5AA0
6SE6420-2UC21-1BA0
6SE6420-2UC21-5BA0
6SE6420-2UC22-2BA0
6SE6420-2UC23-0CA0
6SE6420-2UC11-2AA0
6SE6420-2UC12-5AA0
6SE6420-2UC13-7AA0
6SE6420-2UC15-5AA0
6SE6420-2UC17-5AA0
6SE6420-2UC21-1BA0
6SE6420-2UC21-5BA0
6SE6420-2UC22-2BA0
6SE6420-2UC23-0CA0
6SE6420-2UC24-0CA0
6SE6420-2UC25-5CA0
6SE6420-2UD13-7AA0
6SE6420-2UD15-5AA0
6SE6420-2UD17-5AA0
6SE6420-2UD21-1AA0
6SE6420-2UD21-5AA0
6SE6420-2UD22-2BA0
6SE6420-2UD23-0BA0
6SE6420-2UD24-0BA0
6SE6420-2UD25-5CA0
6SE6420-2UD27-5CA0
6SE6420-2UD31-1CA0
Inverter
with internal filter Class A
6SE6420-2AB11-2AA0
6SE6420-2AB12-5AA0
6SE6420-2AB13-7AA0
6SE6420-2AB15-5AA0
6SE6420-2AB17-5AA0
6SE6420-2AB21-1BA0
6SE6420-2AB21-5BA0
6SE6420-2AB22-2BA0
6SE6420-2AB23-0CA0
6SE6420-2AC23-0CA0
6SE6420-2AC24-0CA0
6SE6420-2AC25-5CA0
6SE6420-2AD22-2BA0
6SE6420-2AD23-0BA0
6SE6420-2AD24-0BA0
6SE6420-2AD25-5CA0
6SE6420-2AD27-5CA0
6SE6420-2AD31-1CA0

6SE6400-0GP00-0AA0

Fuse
(see Catalog NS K)
3NA3803

6SE6400-0GP00-0BA0

3NA3805
3NA3807

6SE6400-0GP00-0CA0
6SE6400-0GP00-0AA0

3NA3810
3NA3812
3NA3803

6SE6400-0GP00-0BA0

3NA3805

6SE6400-0GP00-0AA0

3NA3807
3NA3810
3NA3812
3NA3814
3NA3803

6SE6400-0GP00-0BA0

3NA3805

6SE6400-0GP00-0CA0

3NA3807
6SE6400-0GP00-0CA0
3NA3810
3NA3814

6SE6400-0GP00-0AA0

3NA3803

6SE6400-0GP00-0BA0

3NA3805
3NA3807

6SE6400-0GP00-0CA0
6SE6400-0GP00-0CA0

6SE6400-0GP00-0BA0

3NA3810
3NA3812
3NA3810
3NA3812
3NA3814
3NA3805
3NA3807

6SE6400-0GP00-0CA0
3NA3810
3NA3814

Circuit breaker
(see Catalog NS K)
3RV1021-1CA10
3RV1021-1FA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4BA10
3RV1021-4DA10
3RV1031-4EA10
3RV1031-4GA10
3RV1021-0JA10
3RV1021-1CA10
3RV1021-1DA10
3RV1021-1FA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4DA10
3RV1031-4FA10
3RV1021-1CA10
3RV1021-1DA10
3RV1021-1EA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4CA10
3RV1031-4EA10
3RV1031-4FA10

3RV1021-1CA10
3RV1021-1FA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4BA10
3RV1021-4DA10
3RV1031-4EA10
3RV1031-4GA10
3RV1021-4BA10
3RV1021-4DA10
3RV1031-4FA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4CA10
3RV1031-4EA10
3RV1031-4FA10

Siemens DA 51.2 October 2002

2/13

MICROMASTER 420
Options

Ordering Data for Variant Independent Options


The options listed here are
suitable for all MICROMASTER
420 Inverters.
Options
Basic Operator Panel (BOP)
Advanced Operator Panel (AOP)
PROFIBUS module
DeviceNet module
RS485/PROFIBUS bus connector
Connection set for PC to inverter
Connection set for PC to AOP
Operator panel door mounting kit for single inverter
AOP-door mounting kit for multiple inverter (USS)

Order No.
6SE6400-0BP00-0AA0
6SE6400-0AP00-0AA1
6SE6400-1PB00-0AA0
6SE6400-1DN00-0AA0
6GK1500-0FC00
6SE6400-1PC00-0AA0
6SE6400-0PA00-0AA0
6SE6400-0PM00-0AA0
6SE6400-0MD00-0AA0

Technical data of the communications modules


PROFIBUS module
6SE6400-1PB00-0AA0

DeviceNet module
6SE6400-1DN00-0AA0

Size (height x width x depth)


Degree of protection
Degree of pollution
Mechanical strength
Stationary
Transport

Deflection
Acceleration
Deflection
Acceleration

Climatic category (during operation)


Cooling method
Permissible ambient or cooling agent temperature
in operation
during storage and transport
Relative humidity (permissible humidity rating)
in operation
during storage and transport
Electromagnetic compatibility
Emission
Interference
radiation
Supply voltage

Output voltage

Data transmission rate

2/14

Siemens DA 51.2 October 2002

161 mm x 73 mm x 46 mm
IP 20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to DIN IEC 60 068-2-6 (if module installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to DIN IEC 60 721-3-3
Natural air cooling
10 C to +50 C (14 F to 122 F)
25 C to +70 C (13 F to 158 F)

85% (non-condensing)
95%
to EN 55 011 (1991) Class A
to IEC 60 801-3 and EN 61 000-4-3
6.5 V 5%, max. 300 mA,
internal from inverter or
24 V 10%, max. 350 mA, external
5 V 10%, max. 100 mA,
galvanically isolated supply
for terminating the serial interface bus or
for supplying the OLP (Optical Link Plug)
max. 12 Mbaud

6.5 V 5%, max. 300 mA


internal from inverter and
24 V, max. 60 mA from DeviceNet bus

125, 250 and 500 kbaud

MICROMASTER 420
Options

Documentation
Type of documentation
Docu-Pack,
supplied with each inverter,
containing CD-ROM 1) and
Getting-Started Guide 2)
(paper version)
Operating instructions 2)
(paper version)

Parameter list 2)
(paper version)

Language
Multilanguage

Order No.
6SE6400-5AB00-1AP0

German
English
French
Italian
Spanish
German
English
French
Italian
Spanish

6SE6400-5AA00-0AP0
6SE6400-5AA00-0BP0
6SE6400-5AA00-0DP0
6SE6400-5AA00-0CP0
6SE6400-5AA00-0EP0
6SE6400-5BA00-0AP0
6SE6400-5BA00-0BP0
6SE6400-5BA00-0DP0
6SE6400-5BA00-0CP0
6SE6400-5BA00-0EP0

1) The CD-ROM contains operating instructions, parameter


list, commissioning tools
STARTER and DriveMonitor,
multilanguage.

2) Available on Internet at
http://www.siemens.com/
micromaster

Siemens DA 51.2 October 2002

2/15

MICROMASTER 420
Dimension Drawings

MICROMASTER 420 Inverter


Frame size
A
B
C

200 V to 240 V 1/3 AC


0.12 kW to 0.75 kW
1.1 kW to 2.2 kW
3 kW to 5.5 kW

380 V to 480 V 3 AC
0.37 kW to 1.5 kW
2.2 kW to 4 kW
5.5 kW to 11 kW

73
(2.87)

Fixing with
2 bolts M4, 2 nuts M4,
2 washers M4
or snap on to the DIN rail
Tightening torque with
washers fitted: 2.5 Nm
Ventilation clearance required
at top and bottom: 100 mm

Inverter frame size A

ADA51-5007c

195 (7.68)

58
(2.28)
160 (6.29)

ADA51-5000e

DIN Rail

(5 149
.8
7)

147 (5.79)

173 (6.81)

Drill and fixing pattern

Inverter frame size A


with gland plate

ADA51-5008b

258 (10.16)

ADA51-5001d

202 (7,95)

174 (6.85)

Drill pattern

149 (5.87)

(6 172
.7
7)

138 (5.43)

Fixing with
4 bolts M4, 4 nuts M4,
4 washers M4
Tightening torque with
washers fitted: 2.5 Nm
Ventilation clearance required
at top and bottom: 100 mm

Inverter frame size B

Inverter frame size B


with gland plate

(7 195
.6
8)

174 (6.85)

185 (7.28)

Inverter frame size C

With the communications module, the mounting


depth increases by 23 mm (0.91 inches).

2/16

Siemens DA 51.2 October 2002

Fixing with
4 bolts M5, 4 nuts M5,
4 washers M5
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance required
at top and bottom: 100 mm

ADA51-5009b

309 (12.16)

ADA51-5002d

245 (9.65)

204 (8.03)

Drill pattern

Inverter frame size C


with gland plate

All dimensions are in mm (values in brackets are in inches)

MICROMASTER 420
Dimension Drawings

Filters and Chokes

23.5
(0.93)

73
56

(2.87)
(2.2)

149 (5.87)
120 (4.72)

24
(0.94)

185 (7.28)
156 (6.14)

38
(1.5)

4 x M5

42.5 (1.67)

Filter for frame size A

49.5 (1.95)

138
(5.43)

for frame size B

219 (8.62)
232 (9.13)
ADA51-5012c

245 (9.65)
204 (8.03)

ADA51-5011c

213 (8.39)
174 (6.85)

174 (6.85)
187 (7.36)

ADA51-5010e

200 (7.87)
160 (6.3)

187 (7.36)
200 (7.87)

4 x M4
2 x M4

for frame size C

Line
commutating
choke for

DA51-5014d

DA51-5013e

frame size A

Line commutating choke


for frame size A

frame size B
frame size C

DA51-5050

3TC00-4AD1
DA51-5049

a
200
(7.87)
213
(8.39)
245
(9.65)

b
75.5
(2.97)
150
(5.91)
185
(7.28)

Weight
(max.)
kg
0.8

c
50
(1.97)
50
1.3
(1.97)
50
2.3
(1.97)

Output
choke
Type 6SE6400a

Dimensions

for frame sizes B and C

Output choke
6SE6400-3TC00-4AD1

54 (2.13)

174
(6.85)

3TC01-0BD0
3TC03-2CD0

Dimensions
a
200
(7.87)
213
(8.39)
245
(9.65)

b
75.5
(2.97)
150
(5.91)
185
(7.28)

Weight
(max.)
kg
0.8

c
50
(1.97)
70
3.4
(2.76)
80
5.6
(3.15)

6SE6400-3TC01-0BD0
6SE6400-3TC03-0CD0

All dimensions are in mm (values in brackets are in inches)

Siemens DA 51.2 October 2002

2/17

MICROMASTER 420
Dimension Drawings

DA51-5016b

Assembly of inverter and options

Example:
Assembly of inverter, choke
and filter
If additional accessories are
required, they must be mounted
at the side.

2/18

Siemens DA 51.2 October 2002

Inverter
MICROMASTER 430
3/2

Description

3/4

Circuit Diagrams

3/6

Technical Data

3/8

Selection and Ordering Data

3/9

Options

3/14

Dimension Drawings

Siemens DA 51.2 October 2002

3/1

MICROMASTER 430
Description

Applications

The MICROMASTER 430


inverter is suitable for a variety
of variable-speed drive applications. Its flexibility provides
for a wide spectrum of applications. It is especially suitable for use with industrial
pumps and fans. The inverter
is especially characterized by
its customer-oriented performance and ease of use. It has
more inputs and outputs than
the MICROMASTER 420, an
optimized operator panel with
manual/automatic switchover,
and adapted software functionality.

Main Characteristics

The MICROMASTER 430

Modular construction

Output chokes

inverter complies with the


requirements of the EU lowvoltage guideline; filtered
versions also comply with
the EU EMC guideline
The MICROMASTER 430
inverter has the > marking
u and cu listed

c-tick

The MICROMASTER 430


inverter has a modular design.
The operator panels and
communications modules can
be easily exchanged.

3/2

International Standards

Line commutating chokes

Design

Options (Overview)

Simple commissioning

allows maximum configuration flexibility


Six programmable isolated
digital inputs
Two scalable analog inputs
(0 V to 10 V, 0 mA to 20 mA)
can also be used as a 7th/
8th digital input
Two programmable analog
outputs (0 mA to 20 mA)
Three fully programmable
relay outputs
(30 V DC/5 A, resistive
250 V AC/2 A, inductive)
Silent motor operation is
selectable when using high
switching frequencies
(observe derating if necessary)
Complete inverter and
motor protection
Control of up to three additional drives on the basis of
PID control (motor staging)
Operation of drive directly
on mains (with external
bypass circuit)
Energy saving mode
Detects running-dry of
pumps
(belt failure detection).

Siemens DA 51.2 October 2002

Gland plates
BOP basic operator panel 2

(BOP-2) for parameterizing


an inverter
Communications modules
PROFIBUS
DeviceNet
PC connection kits
Assembly kits for mounting
the operator panels in the
control cabinet doors
PC commissioning tools,
running under Windows 95/
98 and NT/2000.

Note:
See Appendix for standards.

MICROMASTER 430
Description

Mechanical Features

Performance Features

Modular design

Latest IGBT technology

Operating temperature:

Digital microprocessor

10 C to +40 C
Compact housing as a
result of high power density
Easy cable connection,
mains and motor connections are separated for
optimum electromagnetic
compatibility
Detachable operator
panels
Screwless control terminals
on detachable I/O board.

control
Flux current control (FCC)
for improved dynamic
response and optimized
motor control
Linear V/f characteristic
Quadratic V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
Flying restart
Slip compensation
Automatic restart facility
following power failure or
fault
Energy saving mode
(stopping e.g. of a pump at
low speeds)
Motor staging (connection
and disconnection of
additional motors, use of
inverter as control drive in a
pump cascade)
Manual/automatic mode
Load torque detection
(detects running-dry of
pumps)

Protection Features
High-grade PID controller

for simple process control


Programmable acceleration/deceleration,
0 s to 650 s
Ramp smoothing
Fast current limit (FCL) for
trip free operation
Fast, repeatable digital
input response time
Fine speed adjustment
using two high resolution
10-bit analog inputs
Compound braking for
rapid controlled braking
Four skip frequencies
Removable Y capacitor
for use on IT mains supplies
(with non-grounded mains
supplies, the Y capacitor
must be removed, and an
output choke installed).

Overload capability

VT mode
Overload current
1.4 x rated output current
(i.e. 140 % overload
capability) for 3 s and
1.1 x rated output current
(i.e. 110 % overload
capability) for 60 s,
cycle time 300 s
Overvoltage/undervoltage
protection
Inverter overtemperature
protection
Special direct connection
for PTC or KTY to protect
the motor
Earth fault protection
Short circuit protection
I2t motor thermal protection
Locked motor protection
Stall prevention
Parameter interlock.

Siemens DA 51.2 October 2002

3/3

MICROMASTER 430
Circuit Diagrams

General Circuit Diagram


O p e r a to r p a n e l ( O p tio n )

3 8 0 to 4 8 0 V 3 A C
P E
F S 1
+ 1 0 V
1

0 V
2

A IN 1 +

-> 4 , 7 k 9

P E

B O P
S e r ia l
P ro to c o l

L 1 , L 2 , L 3

F o r a d d itio n a l d ig ita l in p u ts
(D IN 7 , D IN 8 ) e x te rn a l
c o n n e c tio n s s h o u ld b e m a d e :

A
3

1
2

2
3

1 0

A IN 1 4
A IN 2 +
A IN 2 -

1 0

D IN 7

1 1

D IN 8

1 1

D IN 1
5

D IN 2

A C

D IN 3
7

D IN 4
8

D IN 5

1 7
9
P T C A

M o to r
P T C /K T Y

P T C B

D C

2 8

O u tp u t + 2 4 V
( is o la te d )
O u tp u t 0 V
( is o la te d )

1 4

C P U

1 5
A O U T 1 +
0 - 2 0 m A ,
m a x . 5 0 0 9

A O U T 1 -

1 2

D C
D

1 3

A C

A O U T 2 +
0 - 2 0 m A ,
m a x . 5 0 0 9

A O U T 2 -

2 6

2 7

R L 1
R L 1 - C
R L 1 - B
R L 1 - A
O u tp u t re
c o n ta c ts
2 5 0 V A C
( in d u c tiv e
3 0 V D C ,
( r e s is tiv e

la y
, m a x . 2 A
lo a d )
m a x . 5 A
lo a d )

R L 2 - C
R L 2 - B

R L 3 - C
R L 3 - A
W h e n
m o d u
th e s e
d o e s n

a c
le is
r ia l
't w

o m m u n ic a tio n s
c o n n e c te d ,
in te r fa c e
o rk .

P +
N -

6 0 H z

N o t
u s e d

2 0
1 9

1 8

R L 2

5 0 H z

D IP S w itc h e s
(o n C o n tro l B o a rd )

2 2
2 1
R L 3

R L 3 - B

2 5

A IN 1 A IN 2

0 - 2 0 m A
0 - 1 0 V

1
2
D IP S w itc h e s
(o n I/O B o a rd )

2 4
2 3
2 9

R S 4 8 5

3 0

P E

U , V , W

A D A 5 1 -5 0 4 8 c

M
3 ~

3/4

a n a
u re d
re s h o
s :
D C
D C =

A IN 1 : 0 V
a n d
A IN 2 : 0 V
a n d

1 6

D IN 6
P N P
o r
N P N

O p to is o la tio n

N o te s :
W h e n
c o n fig
th e th
fo llo w
1 .7 5 V
3 .7 V

Siemens DA 51.2 October 2002

n a lo g in p u t is
a s a d ig ita l in p u t
ld v a lu e s a r e a s
= o ff
o n
to
-1
to
0

1 0
0 V
1 0
m A

V , 0 m A to 2 0 m A
to + 1 0 V
V
to 2 0 m A

MICROMASTER 430
Circuit Diagrams

Terminal Connection Diagram


Example frame size C

View A
Mains
connections
Motor
connections

AIN1 AIN2
S1

RL1-A

RL1-B

RL1-C

RL2-B

RL2-C

RL3-A

RL3-B

RL3-C

18

19

20

21

22

23

24

25

PE
0V

P+

N-

28

29

30

S2

DIP Switches:
0 mA to 20 mA
or
0 V to 10 V

AOUT1+ AOUT1-

12

A DA51-5025

View A

Output relay contacts

PTC
A

PTC
B

DIN5

14

18
15

16

13

DIN6 AOUT2+ AOUT2-

17

26

27

NPN *)

Analog output 1

Digital inputs

(DIN7)

Analog output 2

RS-485
(USS-protocol)
(DIN8)

+10 V

0V

AIN1+

AIN1-

DIN1

DIN2

DIN3

DIN4

+24 V

AIN2+

AIN2-

18
4

10

11

PNP *)

Voltage
supply 10 V

Analog input 1

Digital inputs

Analog input 2

*) PNP or NPN possible

Siemens DA 51.2 October 2002

3/5

MICROMASTER 430
Technical Data

MICROMASTER 430 Inverter


Input voltage and power ranges
Input frequency
Output frequency
Power factor
Inverter efficiency
Overload capability
Inrush current
Control method
PWM frequency
Fixed frequencies
Skip frequency bands
Setpoint resolution

Digital inputs
Analog inputs

Relay outputs
Analog outputs
Serial interfaces
Motor cable length

380 V to 480 V 3 AC 10%


7.5 kW to 90 kW (variable torque)
47 Hz to 63 Hz
0 Hz to 650 Hz
0.95
96 % to 97 %
Overload current 1.4 x rated output current (i.e. 140 % overload capability) for 3 s and
1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s
less than rated input current
linear V/f; quadratic V/f; multipoint characteristic (programmable V/f);
flux current control (FCC), energy saving mode
4 kHz (standard)
2 kHz to 16 kHz (in 2 kHz steps)
15, programmable
4, programmable
0.01 Hz digital
0.01 Hz serial
10 bit analog
6 fully programmable isolated digital inputs; switchable PNP/NPN
2 programmable analog inputs
0 V to 10 V, 0 mA to 20 mA and 10 V to +10 V (AIN1)
0 V to 10 V and 0 mA to 20 mA (AIN2)
both can be used as 7th/8th digital input
3, configurable, 30 V DC/5 A (resistive), 250 V AC/2 A (inductive)
2, programmable (0/4 mA to 20 mA)
RS-485, Option RS-232

without output choke max. 50 m (shielded)


max. 100 m (unshielded)
with output choke max. 200 m (shielded)
max. 300 m (unshielded)
Electromagnetic compatibility
Optional EMC filters to EN 55 011, Class B (for frame size C),
Inverter with internal filter Class A available
Braking
DC Braking, Compound Braking
Protection level
IP 20
Temperature range
10 C to +40 C
Storage temperature
40 C to +70 C
Relative humidity
95% (non-condensing)
Installation height
up to 1000 m above sea level without derating
Protection features for
under-voltage
over-voltage
overload
earth faults
short circuits
stall prevention
locked motor
motor over-temperature
inverter over-temperature
parameter PIN protection

Conformity with standards


u, cu, >, c-tick
> marking
Conformity with EC low voltage directive 73/23/EC
filtered versions also with electromagnetic compatibility directive 89/336/EC
Dimensions and weights
Frame size (FS)
H
x W x D, max. (mm)
(without options)
C
245 x 185 x 195
D
520 x 275 x 245
E
650 x 275 x 245
F without filter
850 x 350 x 320
F with filter
1150 x 350 x 320

3/6

Siemens DA 51.2 October 2002

Weight, approx. (kg)


5.7
17
22
56
75

MICROMASTER 430
Technical Data

Derating Data
Pulse frequency
Rated output
(for 400 V 3 AC)
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90

Rated output current in A


for a pulse frequency of
4 kHz
6 kHz
19.0
17.1
26.0
24.7
32.0
28.8
38.0
36.1
45.0
40.5
62.0
55.8
75.0
71.3
90.0
81.0
110.0
93.5
145.0
123.3
178.0
138.0

8 kHz
15.2
23.4
25.6
34.2
36.0
49.6
67.5
72.0
77.0
101.5
97.9

10 kHz
13.3
20.8
22.4
30.4
31.5
43.4
60.0
63.0
63.3
83.4
84.6

12 kHz
11.4
18.2
19.2
26.6
27.0
37.2
52.5
54.0
49.5
65.3
71.2

14 kHz
9.5
15.6
16.0
22.8
22.5
31.0
45.0
45.0
41.3
54.4
62.3

16 kHz
7.6
13.0
12.8
19.0
18.0
24.8
37.5
36.0
33.0
43.5
53.4

Operating temperature
A D A 5 1 -5 0 4 5 a

R a te d o u tp u t c u rre n t

1 0 0
%
8 0
6 0
5 0
4 0
2 0
0

-1 0
0

1 0

2 0
3 0
4 0 C 5 0
O p e r a tin g te m p e r a tu r e

Installation height above sea level


Permissible output current
in % of the rated output current
ADA51-5018c

Rated output current

100
%
80
60
40
20
0

1000

2000

3000 m 4000
Operational altitude

Permissible mains voltage


in % of the max. possible mains voltage
ADA51-5019b

Mains voltage

100
%
80
77
60
40
20
0

1000

2000

3000 m 4000

Operational altitude

Siemens DA 51.2 October 2002

3/7

MICROMASTER 430
Selection and Ordering Data

MICROMASTER 430 Inverter


Rated output

kW

hp

Rated input
current 1)

Rated output
current

Frame size

Ordering No.
MICROMASTER 430
without filter

MICROMASTER 430
with internal filter
Class A 2)

6SE6430-2UD27-5CA0
6SE6430-2UD31-1CA0
6SE6430-2UD31-5CA0
6SE6430-2UD31-8DA0
6SE6430-2UD32-2DA0
6SE6430-2UD33-0DA0
6SE6430-2UD33-7EA0
6SE6430-2UD34-5EA0
6SE6430-2UD35-5FA0
6SE6430-2UD37-5FA0
6SE6430-2UD38-8FA0

6SE6430-2AD27-5CA0
6SE6430-2AD31-1CA0
6SE6430-2AD31-5CA0
6SE6430-2AD31-8DA0
6SE6430-2AD32-2DA0
6SE6430-2AD33-0DA0
6SE6430-2AD33-7EA0
6SE6430-2AD34-5EA0
6SE6430-2AD35-5FA0
6SE6430-2AD37-5FA0
6SE6430-2AD38-8FA0

(FS)

Mains operating voltage 380 V to 480 V 3 AC


10
15
20
25
30
40
50
60
75
100
120

7.5
11.0
15.0
18.5
22
30
37
45
55
75
90

16.0
22.5
30.5
37.2
43.3
59.3
71.7
86.6
103.6
138.5
168.5

19
26
32
38
45
62
75
90
110
145
178

C
C
C
D
D
D
E
E
F
F
F

See Appendix for note on


ordering.
All MICROMASTER 430
inverters are supplied with a
Status Display Panel SDP. A
BOP-2 or other options have to
be ordered additionally
(see pages 3/11 to 3/13).

1) Additional conditions:
input current at nominal
working point, applies to shortcircuit voltage of mains supply
Vk 1 % referred to rated
inverter power and rated mains
voltage of 400 V.

3/8

2) Use of MICROMASTER inverters with internal filter is not


permissible on non-grounded
mains supplies.

Siemens DA 51.2 October 2002

Motors for

MICROMASTER 430
Catalog M 11 contains selection and ordering data for
motors which are particularly
suitable for operation with the
MICROMASTER 430 inverters
(see Appendix for overview).

MICROMASTER 430
Options

Variant Dependent Options


EMC filter, Class A

Leakage currents:

Line commutating choke

Output choke

All other inverters can be


supplied with an internal
filter Class A.

The leakage currents of the


inverters with/without filter
(internal/external) may
exceed 30 mA. Typical values
in practice are between 10 mA
and 50 mA. The exact values
depend on the design, environment and cable lengths.
Interference-free operation
with residual current operated
devices with a trigger value of
30 mA cannot be guaranteed.
However, operation with residual current operated devices
with a trigger value of 300 mA
is possible. Please refer to the
Instruction Manual for details.

Line commutating chokes are


used to smooth voltage peaks
or to bridge commutating
dips. In addition, line commutating chokes reduce the
effects of harmonics on the
inverter and the power supply.
If the line impedance is < 1%,
a line commutating choke
must be used in order to
reduce the current peaks.

Output chokes can be


supplied for reducing the
capacitive currents and dV/dt
in the case of motor cables
> 50 m (shielded) or
> 100 m (unshielded).

The requirements are fulfilled


using shielded cables with a
max. length of 25 m.
Additional EMC filter,
Class B
Obtainable for inverters with
an internal EMC filter Class A,
frame size C.
With this filter, the inverter
complies with the emission
standard EN 55 011, Class B.
The requirements are fulfilled
using shielded cables with a
max. length of 25 m.

No limits are currently defined


in the EN 61 000-3-2 standard
for professionally used
devices with a connected load
> 1 kW. This means that the
inverters with an output power
0.75 kW comply with the
EN 61 000-3-2 standard.

Gland plate
Gland plates are available for
inverters with frame size C. In
frame sizes D, E and F, the
gland plates are integrated.
The gland plate enables
shielded connection of the
power and control cables,
ensuring optimum EMC
performance. This action
ensures compliance with the
NEMA 1 directive.

Variant Independent Options


Basic Operator Panel 2
(BOP-2)
With the BOP-2, individual
parameter settings can be
made. Values and units are
shown on a 5-digit display.

PROFIBUS module
For a complete PROFIBUS
connection with up to
12 Mbaud. Remote control of
the inverter is possible with the
PROFIBUS module. Remote
control and operation at the
inverter can be combined
using an operator panel
plugged onto the PROFIBUS
module. The latter can be supplied by an external 24 V DC
power supply and is thus also
active when the inverter is disconnected from the mains.
Connection by means of a
9-pin SUB-D connector
(available as an accessory).

Basic Operator Panel (BOP-2)

A BOP-2 can be used for


several inverters. It can be
directly mounted on the
inverter or in a control-cabinet
door using a mounting kit.

DeviceNet module
For networking the inverters to
the DeviceNet fieldbus system
widely used on the American
market. A max. transmission
rate of 500 kbaud is possible.
Remote control of the module
is possible via the DeviceNet
module.

Remote control and operation


on the inverter can be combined using an operator panel
connected to the DeviceNet
module.
The connection to the
DeviceNet bus system is
made using a 5-pin connector
with terminal strip.
Connection set for
PC to inverter

Operator panel door


mounting kit for single
inverter
For mounting an operator
panel in a control cabinet
door. Degree of protection is
IP 56. Contains a cable
adapter board with screwless
terminals for use with the
users own cables.
Commissioning tools

For controlling an inverter


directly from a PC if the
appropriate software has
been installed (e.g. STARTER)
in the PC. Isolated RS-232
adapter board for reliable
point-to-point connection to a
PC. Includes a Sub-D connector and an RS-232 standard
cable (3 m).

STARTER
Starter is start-up software
for guided commissioning
for MICROMASTER
410/420/430/440 frequency
inverters under Windows
NT/2000. Parameter lists
can be read out, altered,
stored, entered and printed.
DriveMonitor
DriveMonitor is start-up
software for list-oriented
programming of frequency
inverters under Windows
95/98/NT/2000.
Both programs are included
on the Docu CD which is
provided with every inverter.

Siemens DA 51.2 October 2002

3/9

MICROMASTER 430
Options

Ordering Data for Variant Dependent Options


The options listed here
(filters, chokes, gland plates,
fuses and circuit breakers) are
inverter specific.
Mains operating
voltage

380 V to 480 V 3 AC

Mains operating
voltage

380 V to 480 V 3 AC

Rated
output

The inverter and the associated options have the same


voltage ratings.

Inverter
without filter

kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90

6SE6430-2UD27-5CA0
6SE6430-2UD31-1CA0
6SE6430-2UD31-5CA0
6SE6430-2UD31-8DA0
6SE6430-2UD32-2DA0
6SE6430-2UD33-0DA0
6SE6430-2UD33-7EA0
6SE6430-2UD34-5EA0
6SE6430-2UD35-5FA0
6SE6430-2UD37-5FA0
6SE6430-2UD38-8FA0

Rated
output

Inverter
without filter

kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90

6SE6430-2UD27-5CA0
6SE6430-2UD31-1CA0
6SE6430-2UD31-5CA0
6SE6430-2UD31-8DA0
6SE6430-2UD32-2DA0
6SE6430-2UD33-0DA0
6SE6430-2UD33-7EA0
6SE6430-2UD34-5EA0
6SE6430-2UD35-5FA0
6SE6430-2UD37-5FA0
6SE6430-2UD38-8FA0

All options are certified


to u, except fuses.
The fuses 3NE1 comply with
u (corresponds to U).

Order No. of the options


Line commutating
choke
6SE6400-3CC02-2CD0
6SE6400-3CC03-5CD0
6SE6400-3CC04-4DD0
6SE6400-3CC05-2DD0
6SE6400-3CC08-3ED0
6SE6400-3CC11-2FD0
6SE6400-3CC11-7FD0

Output choke

Gland plates

6SE6400-3TC03-2CD0

6SE6400-0GP00-0CA0

6SE6400-3TC05-4DD0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC08-0ED0
6SE6400-3TC07-5ED0
6SE6400-3TC14-5FD0
6SE6400-3TC15-4FD0
6SE6400-3TC14-5FD0

Integrated as standard

Order No. of the options


Fuse (see Catalog NS K)
3NA3
3NA3007
3NA3012
3NA3014
3NA3020
3NA3022
3NA3024
3NA3030
3NA3032
3NA3036
3NA3140

3NE1 (U)

3NE1817-0
3NE1818-0
3NE1820-0
3NE1021-0
3NE1022-0
3NE1224-0
3NE1225-0

l Use in America

requires u-listed fuses


such as e.g. the Class
NON range from
Bussmann.

3/10

Siemens DA 51.2 October 2002

Circuit breaker
(see Catalog NS K)
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .

MICROMASTER 430
Options

Ordering Data for Variant Dependent Options (continued)

Mains operating
voltage

380 V to 480 V 3 AC

Mains operating
voltage

380 V to 480 V 3 AC

Mains operating
voltage

380 V to 480 V 3 AC

Rated
output
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
Rated
output
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
Rated
output
kW
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90

Inverter
with internal filter
Class A
6SE6430-2AD27-5CA0
6SE6430-2AD31-1CA0
6SE6430-2AD31-5CA0
6SE6430-2AD31-8DA0
6SE6430-2AD32-2DA0
6SE6430-2AD33-0DA0
6SE6430-2AD33-7EA0
6SE6430-2AD34-5EA0
6SE6430-2AD35-5FA0
6SE6430-2AD37-5FA0
6SE6430-2AD38-8FA0

Order No. of the options


Line commutating
choke
6SE6400-3CC02-2CD0
6SE6400-3CC03-5CD0
6SE6400-3CC04-4DD0
6SE6400-3CC05-2DD0
6SE6400-3CC08-3ED0
6SE6400-3CC11-2FD0
6SE6400-3CC11-7FD0

Output choke
6SE6400-3TC03-2CD0

6SE6400-3TC05-4DD0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC08-0ED0
6SE6400-3TC07-5ED0
6SE6400-3TC14-5FD0
6SE6400-3TC15-4FD0
6SE6400-3TC14-5FD0

Inverter
with internal filter
Class A

Order No. of the options


Supplementary EMC
filter, Class B

Gland plate

6SE6430-2AD27-5CA0
6SE6430-2AD31-1CA0
6SE6430-2AD31-5CA0
6SE6430-2AD31-8DA0
6SE6430-2AD32-2DA0
6SE6430-2AD33-0DA0
6SE6430-2AD33-7EA0
6SE6430-2AD34-5EA0
6SE6430-2AD35-5FA0
6SE6430-2AD37-5FA0
6SE6430-2AD38-8FA0

6SE6400-2FS03-8CD0

6SE6400-0GP00-0CA0

Integrated as standard

Inverter
with internal filter
Class A
6SE6430-2AD27-5CA0
6SE6430-2AD31-1CA0
6SE6430-2AD31-5CA0
6SE6430-2AD31-8DA0
6SE6430-2AD32-2DA0
6SE6430-2AD33-0DA0
6SE6430-2AD33-7EA0
6SE6430-2AD34-5EA0
6SE6430-2AD35-5FA0
6SE6430-2AD37-5FA0
6SE6430-2AD38-8FA0

Order No. of the options


Fuse (see Catalog NS K)
3NA3
3NA3007
3NA3012
3NA3014
3NA3020
3NA3022
3NA3024
3NA3030
3NA3032
3NA3036
3NA3140

3NE1 (U)

3NE1817-0
3NE1818-0
3NE1820-0
3NE1021-0
3NE1022-0
3NE1224-0
3NE1225-0

l Use in America

Circuit breaker
(see Catalog NS K)
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .

requires u-listed
fuses such as e.g. the
Class NON range from
Bussmann.

Siemens DA 51.2 October 2002

3/11

MICROMASTER 430
Options

Ordering Data for Variant Independent Options


The options listed here are
suitable for all
MICROMASTER 430.
Option
Basic Operator Panel 2 (BOP-2)
PROFIBUS module
DeviceNet module
RS485/PROFIBUS bus connector
Connection set for PC to inverter
Operator panel door mounting kit for single inverter

Order No.
6SE6400-0BE00-0AA0
6SE6400-1PB00-0AA0
6SE6400-1DN00-0AA0
6GK1500-0FC00
6SE6400-1PC00-0AA0
6SE6400-0PM00-0AA0

Technical data of the communications modules


PROFIBUS module
6SE6400-1PB00-0AA0

DeviceNet module
6SE6400-1DN00-0AA0

3
Size (height x width x depth)
Degree of protection
Degree of pollution
Mechanical strength
Stationary
Transport

Deflection
Acceleration
Deflection
Acceleration

Climatic category (during operation)


Cooling method
Permissible ambient or cooling agent temperature
in operation
during storage and transport
Relative humidity (permissible humidity rating)
in operation
during storage and transport
Electromagnetic compatibility
Emission
Interference
radiation
Supply voltage

Output voltage

Data transmission rate

3/12

Siemens DA 51.2 October 2002

161 mm x 73 mm x 46 mm
IP 20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to DIN IEC 60 068-2-6 (if module installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to DIN IEC 60 721-3-3
Natural air cooling
10 C to +50 C (14 F to 122 F)
25 C to +70 C (13 F to 158 F)

85% (non-condensing)
95%
to EN 55 011 (1991) Class A
to IEC 60 801-3 and EN 61 000-4-3
6.5 V 5%, max. 300 mA,
internal from inverter or
24 V 10%, max. 350 mA, external
5 V 10%, max. 100 mA,
galvanically isolated supply
for terminating the serial interface bus or
for supplying the OLP (Optical Link Plug)
max. 12 Mbaud

6.5 V 5%, max. 300 mA


internal from inverter and
24 V, max. 60 mA from DeviceNet bus

125, 250 and 500 kbaud

MICROMASTER 430
Options

Documentation
Type of documentation
Docu-Pack,
supplied with each inverter,
containing CD-ROM 1) and
Getting Started Guide 2)
(paper version)
Operating instructions 2)
(paper version)

Parameter list 2)
(paper version)

Language
Multilanguage

Order No.
6SE6400-5AE00-1AP0

German
English
French
Italian
Spanish
German
English
French
Italian
Spanish

6SE6400-5AE00-0AP0
6SE6400-5AE00-0BP0
6SE6400-5AE00-0DP0
6SE6400-5AE00-0CP0
6SE6400-5AE00-0EP0
6SE6400-5AF00-0AP0
6SE6400-5AF00-0BP0
6SE6400-5AF00-0DP0
6SE6400-5AF00-0CP0
6SE6400-5AF00-0EP0

1) The CD-ROM contains operating instructions, parameter


list, commissioning tools
STARTER and DriveMonitor,
multilanguage.

2) Available on Internet at
http://www.siemens.com/
micromaster

Siemens DA 51.2 October 2002

3/13

MICROMASTER 430
Dimension Drawings

MICROMASTER 430 Inverter


Frame size
C
D
E
F

380 V to 480 V 3 AC
7.5 kW to 15 kW
18.5 kW to 30 kW
37 kW to 45 kW
55 kW to 90 kW

174 (6.85)

(7 195
.6
8)

Fixing with
4 bolts M5
4 nuts M5
4 washers M5
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance required
at top and bottom: 100 mm

185 (7.28)

Inverter frame size C

ADA51-5009b

309 (12.16)

ADA51-5002d

245 (9.65)

204 (8.03)

Drill pattern

Inverter frame size C


with gland plates

Drill pattern

Inverter frame size D

Fixing with
4 bolts M8
4 nuts M8
4 washers M8
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance
required at top and bottom:
300 mm

With the communications module the mounting depth increases


with frame size C by 23 mm (0.91 inches).

3/14

Siemens DA 51.2 October 2002

616.4 (24.27)

650 (25.59)
ADA51-5021b

235 (9.25)

275 (10.82)

(9 245
.6
5)

275 (10.82)

(9 245
.6
5)

ADA51-5020b

486 (19.13)

520 (20.47)

Drill pattern

Inverter frame size E

235 (9.25)

Fixing with
4 bolts M8
4 nuts M8
4 washers M8
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance
required at top and bottom:
300 mm

All dimensions are in mm (values in brackets are in inches)

MICROMASTER 430
Dimension Drawings

Drill pattern

1110 (43.70)

1150 (45.28)

810 (31.89)

850 (33.46)

Drill pattern

Inverter frame size F without filter

300 (11.81)

350 (13.78)

(1 320
2.
6)

350 (13.78)

(1 320
2.
6)

300 (11.81)

Fixing with
4 bolts M8
4 nuts M8
4 washers M8
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance
required at top and bottom:
350 mm

ADA51-5023b

ADA51-5022b

3
Inverter frame size F with filter

Fixing with
4 bolts M8
4 nuts M8
4 washers M8
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance
required at top and bottom:
350 mm

All dimensions are in mm (values in brackets are in inches)

Siemens DA 51.2 October 2002

3/15

MICROMASTER 430
Dimension Drawings

Filters and Chokes


185 (7.28)
156 (6.14)

38
(1.5)

ADA51-5012c

245 (9.65)
204 (8.03)

219 (8.62)
232 (9.13)

4 x M5

54 (2.13)

174
(6.85)

Filter for frame size C

DA51-5051

DA51-5014d

Line commutating
choke for

Dimensions
a
b
c
245
185
50
(9.65) (7.28) (1.97)

frame size C

Line commutating
choke for

Weight
(max.)
kg
2.3

frame size D
frame size E

Line commutating choke for frame size C

a
520
(20.47)
650
(25.59)

b
275
(10.83)
275
(10.83)

c
85
(3.35)
95
(3.74)

Weight
(max.)
kg
9.5
17.0

Line commutating choke for frame sizes D and E

DA51-5052

Line commutating
choke
Type 6SE64003CC11-....

n2

n1

Line commutating choke for inverter frame size F

3/16

Dimensions

Siemens DA 51.2 October 2002

for
inverter
frame size
F

Dimensions
a
b
c
n1
n2
210
240
141
109
190
(8.27) (9.45) (5.55) (4.29) (7.48)

Weight
(max.)
kg
25.0

All dimensions are in mm (values in brackets are in inches)

MICROMASTER 430
Dimension Drawings

Output chokes
b

Output choke
for

DA51-5050

Dimensions
a
b
c
245
185
80
(9.65) (7.28) (3.15)

frame size C

Weight
(max.)
kg
5.6

Output choke for frame size C

DA51-5052

n2

n1

Output choke
Type
6SE6400-

for
inverter
frame size
(FS)

Dimensions
a

3TC03-8DD0

3TC05-4DD0

3TC07-5ED0

3TC08-0ED0

3TC14-5FD0

3TC15-4FD0

210
(8.27)
210
(8.27)
248
(9.76)
210
(8.27)
321
(12.64)
210
(8.27)

225
(8.86)
225
(8.86)
270
(10.63)
225
(8.86)
350
(13.78)
225
(8.86)

179
(7.05)
150
(5.91)
209
(8.23)
150
(5.91)
288
(11.34)
150
(5.91)

n1
n2
(to DIN 41308)
76
176
(2.99)
(6.93)
76
176
(2.99)
(6.93)
88
200
(3.46)
(7.87)
76
176
(2.99)
(6.93)
120
264
(4.72)
(10.39)
76
176
(2.99)
(6.93)

Weight
(max.)
kg
16.1
10.7

24.9
10.4
51.5
11.2

Output choke
for inverter frame sizes D, E and F

All dimensions are in mm (values in brackets are in inches)

Siemens DA 51.2 October 2002

3/17

MICROMASTER 430
Dimension Drawings

DA51-5042a

Assembly of inverter and options

Example:
Assembly of inverter, choke
and filter
If additional accessories
are required, they must be
mounted at the side.

3/18

Siemens DA 51.2 October 2002

Inverter
MICROMASTER 440
4/2

Description

4/4

Circuit Diagrams

4/6

Technical Data

4/9

Selection and Ordering Data

4/12

Options

4/21

Dimension Drawings

Siemens DA 51.2 October 2002

4/1

MICROMASTER 440
Description

Applications

The MICROMASTER 440


inverter is suitable for a variety
of variable-speed drive applications. Its flexibility provides
for a wide spectrum of applications. These also include
cranes and hoisting gear,
high-bay warehouses, production machines for food,
beverages and tobacco,
packaging machines etc.; i.e.
applications which require the
frequency inverter to have a
higher functionality and
dynamic response than usual.
The inverter is especially
characterized by its customeroriented performance and
ease of use. Its large supplyvoltage range enables it to be
used all over the world.

Design
The MICROMASTER 440 has
a modular design. The operator panels and the modules
can be easily exchanged.

International Standards
The MICROMASTER 440

inverter complies with the


requirements of the EU lowvoltage guideline; filtered
versions also comply with
the EU EMC guideline
The MICROMASTER 440
inverter has the > marking
u and cu listed

c-tick
Note:
See Appendix for standards.

Main Characteristics

EMC filters Class A/B

Modular construction

Line commutating chokes

4/2

Siemens DA 51.2 October 2002

Options (Overview)

Simple commissioning

allows maximum configuration flexibility


Six programmable isolated
digital inputs
Two scalable analog inputs
(0 V to 10 V, 0 mA to 20 mA)
can also be used as a 7th/
8th digital input
Two programmable analog
outputs (0 mA to 20 mA)
Three fully programmable
relay outputs
(30 V DC/5 A, resistive
250 V AC/2 A, inductive)
Silent motor operation is
selectable when using high
switching frequencies
(observe derating if necessary)
Complete inverter and
motor protection.

Output chokes
Gland plates
BOP basic operator panel

for parameterizing an
inverter
AOP advanced operator
panel with plain-text and
multilingual display
Communications module
PROFIBUS
DeviceNet
Pulse encoder evaluation
module
PC connection kits
Assembly kits for mounting
the operator panels in the
control cabinet doors
PC commissioning tools,
running under Windows 95/
98 and NT/2000.

MICROMASTER 440
Description

Mechanical Features

Performance Features

Modular design

Latest IGBT technology

Operating temperature

Digital microprocessor

0.12 kW to 75 kW:
10 C to +50 C
90 kW to 200 kW:
0 C to +40 C
Compact housing as a
result of high power density
Easy cable connection,
mains and motor connections are separated for
optimum electromagnetic
compatibility
Detachable operator
panels
Screwless control terminals
on detachable I/O board.

control
High-quality Vector Control
system
Flux current control (FCC)
for improved dynamic
response and optimized
motor control
Linear V/f characteristic
Quadratic V/f characteristic
Multipoint characteristic
(programmable V/f characteristic)
Torque control
Flying restart
Slip compensation
Automatic restart facility
following power failure or
fault
User-definable function
blocks for logic and arithmetic operations
Kinetic buffering
Positioning deceleration
ramp
High-grade PID controller
(auto-tuning) for simple
process control
Programmable acceleration/deceleration,
0 s to 650 s
Ramp smoothing
Fast current limit (FCL) for
trip free operation
Fast, repeatable digital
input response time
Fine speed adjustment
using two high resolution
10-bit analog inputs
Compound braking for
rapid controlled braking
Integral brake chopper
(only for 0.12 kW to 75 kW
inverters)
Four skip frequencies
Removable Y capacitor
for use on IT mains supplies
(with non-grounded mains
supplies, the Y capacitor
must be removed, and an
output choke installed).

Protection Features
Overload capability

Overvoltage/undervoltage

CT mode
0.12 kW to 75 kW:
Overload current
1.5 x rated output current
(i.e. 150 % overload
capability) for 60 s,
cycle time 300 s,
and 2 x rated output current (i.e. 200 % overload
capability) for 3 s,
cycle time 300 s
90 kW to 200 kW:
Overload current
1.36 x rated output current (i.e. 136 % overload
capability) for 57 s,
cycle time 300 s,
and 1.6 x rated output
current (i.e. 160 % overload capability) for 3 s,
cycle time 300 s
VT mode
5.5 kW to 90 kW:
Overload current
1.4 x rated output current
(i.e. 140 % overload
capability) for 3 s,
and 1.1 x rated output
current (i.e. 110 % overload capability) for 60 s,
cycle time 300 s
110 kW to 250 kW:
Overload current
1.5 x rated output current
(i.e. 150 % overload
capability) for 1 s,
and 1.1 x rated output
current (i.e. 110 % overload capability) for 59 s,
cycle time 300 s

protection
Inverter overtemperature

protection
Special direct connection

for PTC or KTY to protect


the motor
Earth fault protection
Short circuit protection
I2t motor thermal protection
Locked motor protection
Stall prevention
Parameter interlock.

Siemens DA 51.2 October 2002

4/3

MICROMASTER 440
Circuit Diagrams

General Circuit Diagram


O p e r a to r p a n e l ( O p tio n )

I
O

F S 1
P E

B O P
S e r ia l
P ro to c o l

0 V
2

A IN 1 +

- > 4 ., 7 k 9

J o g

+ 1 0 V
1

2 0 0 to 2 4 0 V 1 /3 A C
3 8 0 to 4 8 0 V 3 A C
5 0 0 to 6 0 0 V 3 A C
P E

F n

A
3

F o r a d d itio n a l d ig ita l in p u ts
(D IN 7 , D IN 8 ) e x te rn a l
c o n n e c tio n s s h o u ld b e m a d e :

L , N
(L 1 , L 2 )
o r
L 1 , L 2 , L 3

1
2

2
3

1 0

A IN 1 4
A IN 2 +
A IN 2 -

1 0

D IN 7

1 1

N o te s :
W h e n
c o n fig
th e th
fo llo w
1 .7 5 V
3 .7 V

D IN 1
5

D IN 2

A C
7

D IN 4
8

D IN 5

1 7

P N P
o r
N P N
9
P T C A
M o to r
P T C /K T Y

P T C B

D C /R +

2 8

A
D

C P U

1 5
A O U T 1 +
0 - 2 0 m A ,
m a x . 5 0 0 9

A O U T 1 -

1 2

= o ff
o n
to
-1
to
0

1 0
0 V
1 0
m A

V , 0 m A to 2 0 m A
to + 1 0 V
V
to 2 0 m A

D C

9 0 k W t o 2 0 0 k W in v e r t e r s d o n 't
h a v e a n in te g r a te d b r a k in g c h o p p e r

A C
A C

A O U T 2 +
A O U T 2 -

n a lo g in p u t is
a s a d ig ita l in p u t
ld v a lu e s a r e a s

D C
D

1 3
0 - 2 0 m A ,
m a x . 5 0 0 9

D C
A

2 6

2 7

D /L -

R L 1
R L 1 - C
R L 1 - B
O u tp u t re
c o n ta c ts
2 5 0 V A C
( in d u c tiv e
3 0 V D C ,
( r e s is tiv e

R L 1 - A

la y
, m a x . 2 A
lo a d )
m a x . 5 A
lo a d )

R L 2 - C
R L 2 - B

R L 3 - C
R L 3 - A
W h e n
m o d u
th e s e
d o e s n

a c
le is
r ia l
't w

6 0 H z

N o t
u s e d

2 0
1 9

1 8

R L 2

o m m u n ic a tio n s
c o n n e c te d ,
in te r fa c e
o rk .

P +
N -

5 0 H z

C /L +

D IP S w itc h e s
(o n C o n tro l B o a rd )

2 2
2 1
A IN 1 A IN 2

R L 3
R L 3 - B

0 - 2 0 m A

2 5

0 - 1 0 V

2 3
2 9

D C

1
2
D IP S w itc h e s
(o n I/O B o a rd )

2 4

A C

R S 4 8 5

3 0

P E

U , V , W

A D A 5 1 -5 0 2 4 f

M
3 ~

4/4

1 1

B r a k in g
r e s is to r

O u tp u t 0 V
( is o la te d )

1 4

D IN 8

F a c to ry
fitte d
lin k

B + /D C +

O u tp u t + 2 4 V
( is o la te d )

a n a
u re d
re s h o
s :
D C
D C =

A IN 1 : 0 V
a n d
A IN 2 : 0 V
a n d

D C

1 6

D IN 6

O p to is o la tio n

D IN 3

Siemens DA 51.2 October 2002

C o n n e c tio n
fo r
e x te rn a l
b r a k in g
u n it

MICROMASTER 440
Circuit Diagrams

Terminal Connection Diagram


Example frame size FX
Mains connections

View A

Motor connections

AIN1 AIN2
S1

RL1-A

RL1-B

RL1-C

RL2-B

RL2-C

RL3-A

RL3-B

RL3-C

18

19

20

21

22

23

24

25

PE
0V

P+

N-

28

29

30

S2

DIP Switches:
0 mA to 20 mA
or
0 V to 10 V

AOUT1+ AOUT1-

12

A DA51-5025

View A

Output relay contacts

PTC
A

PTC
B

DIN5

14

18
15

16

13

DIN6 AOUT2+ AOUT2-

17

26

27

NPN *)

Analog output 1

Digital inputs

(DIN7)

Analog output 2

RS-485
(USS-protocol)
(DIN8)

+10 V

0V

AIN1+

AIN1-

DIN1

DIN2

DIN3

DIN4

+24 V

AIN2+

AIN2-

18
4

10

11

PNP *)

Voltage
supply 10 V

Analog input 1

Digital inputs

Analog input 2

*) PNP or NPN possible

Siemens DA 51.2 October 2002

4/5

MICROMASTER 440
Technical Data

MICROMASTER 440 Inverter


Input voltage and
power ranges

200 V to 240 V 1 AC 10 %
200 V to 240 V 3 AC 10 %
380 V to 480 V 3 AC 10 %
500 V to 600 V 3 AC 10 %
47 Hz to 63 Hz
0 Hz to 650 Hz (in V/f mode)
0.95
96 % to 97 %

CT (constant torque)
0.12 kW to 3 kW
0.12 kW to 45 kW
0.37 kW to 200 kW
0.75 kW to 75 kW

VT (variable torque)

5.5 kW to 45 kW
7.5 kW to 250 kW
1.5 kW to 90 kW

Input frequency
Output frequency
Power factor
Inverter efficiency
Overload capability
CT operation
0.12 kW to 75 kW Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s,
and 2 x rated output current (i.e. 200 % overload capability) for 3 s, cycle time 300 s
90 kW to 200 kW Overload current 1.36 x rated output current (i.e. 136 % overload capability) for 57 s, cycle time 300 s,
and 1.6 x rated output current (i.e. 160 % overload capability) for 3 s, cycle time 300 s
VT operation
5.5 kW to 90 kW Overload current 1.4 x rated output current (i.e. 140 % overload capability) for 3 s and
1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s
110 kW to 250 kW Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 1 s and
1.1 x rated output current (i.e. 110 % overload capability) for 59 s, cycle time 300 s
Inrush current
less than rated input current
Control method
Vector control, torque control, linear V/f; quadratic V/f characteristic;
multipoint characteristic (programmable V/f characteristic); flux current control (FCC)
PWM frequency
0.12 kW to 75 kW 4 kHz (standard); 16 kHz (standard with 230 V inverters 0.12 kW to 5.5 kW)
2 kHz to 16 kHz (in 2 kHz steps)
90 kW to 200 kW 2 kHz (standard with VT mode); 4 kHz (standard with CT mode)
2 kHz to 8 kHz (in 2 kHz steps)
Fixed frequencies
15, programmable
Skip frequency bands
4, programmable
Setpoint resolution
0.01 Hz digital
0.01 Hz serial
10 bit analog
Digital inputs
6 fully programmable isolated digital inputs; switchable PNP/NPN
Analog inputs
2 programmable analog inputs
0 V to 10 V, 0 mA to 20 mA and 10 V to +10 V (AIN1)
0 V to 10 V and 0 mA to 20 mA (AIN2)
both can be used as 7th/8th digital input
Relay outputs
3, programmable, 30 V DC/5 A (resistive), 250 V AC/2 A (inductive)
Analog inputs
2, programmable (0/4 mA to 20 mA)
Serial interfaces
RS-485, optional RS-232
Motor cable length
0.12 75 kW
without output choke max. 50 m (shielded), max. 100 m (unshielded)
with output choke max. 200 m (shielded), max. 300 m (unshielded)
90 250 kW
without output choke max. 100 m (shielded), max. 150 m (unshielded)
with output choke in preparation
Electromagnetic
0.12 kW to 75 kW Optional EMC filters to EN 55 011, Class A or Class B (for frame sizes A, B, C),
compatibility
Inverter with internal filter Class A available (frame sizes A, B, C, D, E, F)
Braking
Resistance braking with DC braking, compound braking, integral brake chopper
(integral brake chopper only with 0.12 kW to 75 kW inverters)
Protection level
IP 20
Temperature
0.12 kW to 75 kW 10 C to +50 C (CT)
range
10 C to +40 C (VT)
(without derating) 90 kW to 200 kW
0 C to +40 C
Storage temperature
40 C to +70 C
Humidity
95% (non-condensing)
Operational
0.12 kW to 75 kW up to 1000 m above sea level without derating
altitudes
90 kW to 200 kW up to 2000 m above sea level without derating
Protection features for
under-voltage, over-voltage, overload, earth faults, short circuits, stall prevention, locked motor,
motor over-temperature, inverter over-temperature, parameter PIN protection

Conformity with standards


u, cu, >, c-tick
> marking
Conformity with EC low voltage directive 73/23/EC
filtered versions also with electromagnetic compatibility directive 89/336/EC
Dimensions and weights
Frame size (FS)
H
x W x D, max. (mm)
Weight, approx. (kg)
(without options)
A
173 x 73 x 149
1.3
B
202 x 149 x 172
3.4
C
245 x 185 x 195
5.7
D
520 x 275 x 245
17
E
650 x 275 x 245
22
F without filter
850 x 350 x 320
56
F with filter
1150 x 350 x 320
75
FX
1555 x 330 x 360
110
GX
1875 x 330 x 560
190

4/6

Siemens DA 51.2 October 2002

MICROMASTER 440
Technical Data

Derating Data
Pulse frequency
Rated output

Rated output current in A


for a pulse frequency of
kW
4 kHz
6 kHz
8 kHz
10 kHz
Mains operating voltage 200 V 1/3 AC
0.12 to 5.5
Values correspond to the 4-kHz standard values.
No derating, since 16 kHz standard.
7.5
28.0
26.6
25.2
22.4
11
42.0
37.8
33.6
29.4
15
54.0
48.6
43.2
37.8
18.5
68.0
64.6
61.2
54.4
22
80.0
72.0
64.0
56.0
30
104.0
91.0
78.0
70.2
37
130.0
113.8
97.5
87.8
45
154.0
134.8
115.5
104.0
Mains operating voltage 400 V 3 AC
0.37
1.3
1.3
1.3
1.3
0.55
1.7
1.7
1.7
1.6
0.75
2.2
2.2
2.2
2.0
1.1
3.1
2.9
2.8
2.5
1.5
4.1
3.7
3.3
2.9
2.2
5.9
5.6
5.3
4.7
3.0
7.7
6.9
6.2
5.4
4.0
10.2
9.2
8.2
7.1
5.5
13.2
11.9
10.6
9.2
7.5
19.0
18.1
17.1
15.2
11.0
26.0
23.4
20.8
18.2
15.0
32.0
30.4
28.8
25.6
18.5
38.0
34.2
30.4
26.6
22
45.0
40.5
36.0
31.5
30
62.0
58.9
55.8
49.6
37
75.0
67.5
60.0
52.5
45
90.0
76.5
63.0
51.8
55
110.0
93.5
77.0
63.3
75
145.0
112.4
79.8
68.9
90
178.0
131.5
101.1

110
205.0
151.4
116.5

132
250.0
184.7
142.1

160
302.0
223.1
171.6

200
370.0
273.3
210.2

Mains operating voltage 500 V 3 AC


0.75
1.4
1.2
1.0
0.8
1.5
2.7
2.2
1.6
1.4
2.2
3.9
2.9
2.0
1.6
4.0
6.1
4.6
3.1
2.4
5.5
9.0
6.8
4.5
3.6
7.5
11.0
8.8
6.6
5.5
11.0
17.0
12.8
8.5
6.8
15.0
22.0
17.6
13.2
11.0
18.5
27.0
20.3
13.5
10.8
22
32.0
24.0
16.0
12.8
30
41.0
32.8
24.6
20.5
37
52.0
39.0
26.0
20.8
45
62.0
52.7
43.4
40.3
55
77.0
67.4
57.8
52.0
75
99.0
84.2
69.3
64.4

12 kHz

14 kHz

16 kHz

19.6
25.2
32.4
47.6
48.0
62.4
78.0
92.4

16.8
21.0
27.0
40.8
40.0
57.2
71.5
84.7

14.0
16.8
21.6
34.0
32.0
52.0
65.0
77.0

1.3
1.5
1.8
2.2
2.5
4.1
4.6
6.1
7.9
13.3
15.6
22.4
22.8
27.0
43.4
45.0
40.5
49.5
58.0

1.2
1.4
1.5
1.9
2.1
3.5
3.9
5.1
6.6
11.4
13.0
19.2
19.0
22.5
37.2
37.5
33.8
41.3
50.8

1.0
1.2
1.3
1.6
1.6
3.0
3.1
4.1
5.3
9.5
10.4
16.0
15.2
18.0
31.0
30.0
27.0
33.0
43.5

0.7
1.1
1.2
1.8
2.7
4.4
5.1
8.8
8.1
9.6
16.4
15.6
37.2
46.2
59.4

0.6
0.9
1.0
1.5
2.3
3.9
4.3
7.7
6.8
8.0
14.4
13.0
32.6
42.4
52.0

0.6
0.8
0.8
1.2
1.8
3.3
3.4
6.6
5.4
6.4
12.3
10.4
27.9
38.5
44.6

Siemens DA 51.2 October 2002

4/7

MICROMASTER 440
Technical Data

Derating Data (continued)


Operating temperature
Inverter 0.12 kW to 0.75 kW

Inverter 90 kW to 200 kW

A D A 5 1 -5 0 2 6 b

R a te d o u tp u t c u rre n t

C T
V T

6 0
5 0
4 0

R a te d o u tp u t c u rre n t

A D A 5 1 -5 0 4 7 a

1 0 0
%
8 0

1 0 0
8 5
8 0
%
6 0
4 0
2 0

2 0
0

-1 0

1 0

2 0

3 0
4 0
5 0
6 0 C 7 0
O p e r a tin g te m p e r a tu r e

2 0

1 0

5 5
3 0
4 0 4 5 C
O p e r a tin g te m p e r a tu r e

Installation height above sea level


Permissible output current
in % of the rated output current
Inverter 0.12 kW to 75 kW

Inverter 90 kW to 200 kW

ADA51-5018c

ADA51-5046

100
85
80
%
60

Rated output current

Rated output current

100
%
80
60
40

20

20
0

1000

2000

3000 m 4000
Operational altitude

1000

2000

3000 m 4000
Operational altitude

Permissible mains voltage


in % of the max. possible mains voltage
Inverter 0.12 kW to 75 kW

Inverter 90 kW to 200 kW

ADA51-5019b

ADA51-5019b

100
%
80
77

Mains voltage

100
%
80
77

Mains voltage

40

60

60

40

40

20

20

1000

2000

3000 m 4000

Operational altitude

4/8

Siemens DA 51.2 October 2002

1000

2000

3000 m 4000

Operational altitude

MICROMASTER 440
Selection and Ordering Data

MICROMASTER 440 Inverter without filter


CT (constant torque)
Rated output
Rated input
current 1)
kW
hp
A

Rated output
current
A

VT (variable torque)
Rated output
Rated input
current 1)
kW
hp
A

Rated output
current
A

MICROMASTER 440 without filter


Frame
weight
Order No.
size
approx.
(FS)
kg

Mains operating voltage 200 V to 240 V 1 AC


0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0

0.16
0.33
0.50
0.75
1.0
1.5
2
3
4

1.4
2.7
3.7
5.0
6.6
9.6
13.0
17.6
23.7

0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6

A
A
A
A
A
B
B
B
C

1.3
1.3
1.3
1.3
1.3
3.3
3.3
3.3
5.5

6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1

7.5
10
15
20
25
30
40
50
60

17.6
26.5
38.4
50.3
61.5
70.8
96.2
114.1
134.9

22
28
42
54
68
80
104
130
154

A
A
A
A
A
B
B
B
C
C
C
D
D
D
E
E
F
F
F

1.3
1.3
1.3
1.3
1.3
3.3
3.3
3.3
5.5
5.5
5.5
17
16
16
20
20
55
55
55

6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC24-0CA1
6SE6440-2UC25-5CA1
6SE6440-2UC27-5DA1
6SE6440-2UC31-1DA1
6SE6440-2UC31-5DA1
6SE6440-2UC31-8EA1
6SE6440-2UC32-2EA1
6SE6440-2UC33-0FA1
6SE6440-2UC33-7FA1
6SE6440-2UC34-5FA1

7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
250

10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350

16.0
22.5
30.5
37.2
43.3
59.3
71.7
86.6
103.6
138.5
168.5
204.5
244.5
296.4
354.0
442.0

19
26
32
38
45
62
75
90
110
145
178
205
250
302
370
477

1.3
1.3
1.3
1.3
1.3
3.3
3.3
3.3
5.5
5.5
5.5
16
16
16
20
20
56
56
56
110
110
190
190
190

6SE6440-2UD13-7AA1
6SE6440-2UD15-5AA1
6SE6440-2UD17-5AA1
6SE6440-2UD21-1AA1
6SE6440-2UD21-5AA1
6SE6440-2UD22-2BA1
6SE6440-2UD23-0BA1
6SE6440-2UD24-0BA1
6SE6440-2UD25-5CA1
6SE6440-2UD27-5CA1
6SE6440-2UD31-1CA1
6SE6440-2UD31-5DA1
6SE6440-2UD31-8DA1
6SE6440-2UD32-2DA1
6SE6440-2UD33-0EA1
6SE6440-2UD33-7EA1
6SE6440-2UD34-5FA1
6SE6440-2UD35-5FA1
6SE6440-2UD37-5FA1
6SE6440-2UD38-8FA0
6SE6440-2UD41-1FA0
6SE6440-2UD41-3GA0
6SE6440-2UD41-6GA0
6SE6440-2UD42-0GA0

Mains operating voltage 200 V to 240 V 3 AC


0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45

0.16
0.6
0.33
1.1
0.50
1.6
0.75
2.1
1.0
2.9
1.5
4.1
2.0
5.6
3.0
7.6
4.0
10.5
5.0
13.1
7.5
17.5
10
25.3
15
37.0
20
48.8
25
61.0
30
69.4
40
94.1
50
110.6
60
134.9

0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6
17.5
22
28
42
54
68
80
104
130
154

5.5
7.5
11.0
15.0
18.5
22
30
37
45

Mains operating voltage 380 V to 480 V 3 AC


0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200

0.50
0.75
1.0
1.5
2.0
3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300

1.1
1.4
1.9
2.8
3.9
5.0
6.7
8.5
11.6
15.4
22.5
30.0
36.6
43.1
58.7
71.2
85.6
103.6
138.5
168.5
204.0
244.5
296.4
354.0

1) Additional conditions:
input current at nominal working point, applies to short-

1.3
1.7
2.2
3.1
4.1
5.9
7.7
10.2
13.2
19
26
32
38
45
62
75
90
110
145
178
205
250
302
370

circuit voltage of mains supply


Vk 1 % referred to rated
inverter power and rated mains

A
A
A
A
A
B
B
B
C
C
C
D
D
D
E
E
F
F
F
FX
FX
GX
GX
GX

voltage of 240 V or 400 V or


500 V.

Siemens DA 51.2 October 2002

4/9

MICROMASTER 440
Selection and Ordering Data

MICROMASTER 440 Inverter without filter (continued)


CT (constant torque)
Rated output
kW

hp

Rated input
current 1)
A

VT (variable torque)
Rated output
current
A

Rated output
kW

MICROMASTER 440 without filter


Rated output
current
A

Frame
size
(FS)

weight
approx.
kg

Order No.

hp

Rated input
current 1)
A

2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
120

3.2
4.4
6.9
9.4
12.6
18.1
24.9
29.8
35.1
47.5
57.9
69.4
83.6
113.4
137.6

2.7
3.9
6.1
9
11
17
22
27
32
41
52
62
77
99
125

C
C
C
C
C
C
C
D
D
D
E
E
F
F
F

5.5
5.5
5.5
5.5
5.5
5.5
5.5
16
16
16
20
20
56
56
56

6SE6440-2UE17-5CA1
6SE6440-2UE21-5CA1
6SE6440-2UE22-2CA1
6SE6440-2UE24-0CA1
6SE6440-2UE25-5CA1
6SE6440-2UE27-5CA1
6SE6440-2UE31-1CA1
6SE6440-2UE31-5DA1
6SE6440-2UE31-8DA1
6SE6440-2UE32-2DA1
6SE6440-2UE33-0EA1
6SE6440-2UE33-7EA1
6SE6440-2UE34-5FA1
6SE6440-2UE35-5FA1
6SE6440-2UE37-5FA1

Mains operating voltage 500 V to 600 V 3 AC


0.75
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75

1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100

2.0
3.2
4.4
6.9
9.4
12.3
18.1
24.2
29.5
34.7
47.2
57.3
69.0
82.9
113.4

1.4
2.7
3.9
6.1
9
11
17
22
27
32
41
52
62
77
99

1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90

See Appendix for note on


ordering.
All MICROMASTER 440
inverters are supplied with
a Status Display Panel SDP.
A Basic Operator Panel BOP,
Advanced Operator Panel
AOP or other options have to
be ordered additionally (see
pages 4/14 to 4/20).

1) Additional conditions:
input current at nominal working point, applies to short-circuit voltage of mains supply Vk
1 % referred to rated inverter
power and rated mains voltage
of 240 V or 400 V or 500 V.

4/10

Siemens DA 51.2 October 2002

Motors for

MICROMASTER 440
Catalog M 11 contains selection and ordering data for
motors which are particularly
suitable for operation with the
MICROMASTER 440 inverters
(see Appendix for overview).

MICROMASTER 440
Selection and Ordering Data

MICROMASTER 440 Inverter with internal filter Class A


CT (constant torque)
Rated output
kW

hp

Rated input
current 1)
A

VT (variable torque)
Rated output
current
A

hp

Rated input
current 1)
A

Rated output
current
A

MICROMASTER 440
with internal filter Class A 2)
Frame
weight
Order No.
size
approx.
(FS)
kg

A
A
A
A
A
B
B
B
C

1.3
1.3
1.3
1.3
1.3
3.4
3.4
3.4
5.7

6SE6440-2AB11-2AA1
6SE6440-2AB12-5AA1
6SE6440-2AB13-7AA1
6SE6440-2AB15-5AA1
6SE6440-2AB17-5AA1
6SE6440-2AB21-1BA1
6SE6440-2AB21-5BA1
6SE6440-2AB22-2BA1
6SE6440-2AB23-0CA1

C
C
C

5.7
5.7
5.7

6SE6440-2AC23-0CA1
6SE6440-2AC24-0CA1
6SE6440-2AC25-5CA1

B
B
B
C
C
C
D
D
D
E
E
F
F
F

3.4
3.4
3.4
5.7
5.7
5.7
17
17
17
22
22
75
75
75

6SE6440-2AD22-2BA1
6SE6440-2AD23-0BA1
6SE6440-2AD24-0BA1
6SE6440-2AD25-5CA1
6SE6440-2AD27-5CA1
6SE6440-2AD31-1CA1
6SE6440-2AD31-5DA1
6SE6440-2AD31-8DA1
6SE6440-2AD32-2DA1
6SE6440-2AD33-0EA1
6SE6440-2AD33-7EA1
6SE6440-2AD34-5FA1
6SE6440-2AD35-5FA1
6SE6440-2AD37-5FA1

Rated output
kW

Mains operating voltage 200 V to 240 V 1 AC


0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0

0.16
0.33
0.50
0.75
1.0
1.5
2
3
4

1.4
2.7
3.7
5.0
6.6
9.6
13.0
17.6
23.7

0.9
1.7
2.3
3.0
3.9
5.5
7.4
10.4
13.6

Mains operating voltage 200 V to 240 V 3 AC


4.0
5.0
7.5

3.0
4.0
5.5

10.5
13.1
17.5

13.6
17.5
22.0

5.0
7.5
10.0

4.0
5.5
7.5

13.1
17.6
26.5

17.5
22
28

Mains operating voltage 380 V to 480 V 3 AC


3.0
4.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100

2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75

5.0
6.7
8.5
11.6
15.4
22.5
30.0
36.6
43.1
58.7
71.2
85.6
103.6
138.5

5.9
7.7
10.2
13.2
18.4
26
32
38
45
62
75
90
110
145

7.5
11.0
15.0
18.5
22
30
37
45
55
75
90

10
15
20
25
30
40
50
60
75
100
125

16.0
22.5
30.5
37.2
43.3
59.3
71.7
86.6
103.6
138.5
168.5

19
26
32
38
45
62
75
90
110
145
178

See Appendix for note on


ordering.
All MICROMASTER 440
inverters are supplied with
a Status Display Panel SDP.
A Basic Operator Panel BOP,
Advanced Operator Panel
AOP or other options have to
be ordered additionally (see
pages 4/14 to 4/20).

1) Additional conditions:
input current at nominal working point, applies to shortcircuit voltage of mains supply
Vk 1 % referred to rated
inverter power and rated mains
voltage of 240 V or 400 V.

Motors for

MICROMASTER 440
Catalog M 11 contains selection and ordering data for
motors which are particularly
suitable for operation with the
MICROMASTER 440 inverters
(see Appendix for overview).

2) Use of MICROMASTER inverters with internal filter is not


permissible on non-grounded
mains supplies.

Siemens DA 51.2 October 2002

4/11

MICROMASTER 440
Options

Variant Dependent Options


EMC filter, Class A
Filter for inverters without an
internal filter, for
200 V to 240 V 3 AC,
frame sizes A and B
380 V to 480 V 3 AC,
frame size A.

EMC filter for 200 V to 240 V


1 AC inverters, frame sizes A
and B, without an internal EMC
filter Class A.

All other inverters can be


supplied with an internal
filter Class A.

With this filter, the inverter


complies with the emission
standard EN 55 011, Class B.
Leakage currents are reduced
to < 3.5 mA.

The requirements are fulfilled


using shielded cables with a
max. length of 25 m.

The requirements are fulfilled


using shielded cables with a
max. length of 5 m.

EMC filter, Class B


Filter for inverters without an
internal filter, for
200 V to 240 V 3 AC,
frame sizes A and B
380 V to 480 V 3 AC,
frame size A.
With this filter, the inverter
complies with the emission
standard EN 55 011, Class B.
The requirements are fulfilled
using shielded cables with a
max. length of 25 m.
Additional EMC filter,
Class B

Class B filter with


low leakage currents

Leakage currents:
The leakage currents of the
inverters with/without filter
(internal/external) may
exceed 30 mA. Typical values
in practice are between 10 mA
and 50 mA. The exact values
depend on the design, environment and cable lengths.
Interference-free operation
with residual current operated
devices with a trigger value of
30 mA cannot be guaranteed.
However, operation with residual current operated devices
with a trigger value of 300 mA
is possible. Please refer to the
Instruction Manual for details.

Obtainable for inverters with


an internal EMC filter Class A,
frame sizes A, B, C.
With this filter, the inverter
complies with the emission
standard EN 55 011, Class B.
The requirements are fulfilled
using shielded cables with a
max. length of 25 m.

4/12

Siemens DA 51.2 October 2002

Line commutating choke

Output choke

Line commutating chokes are


used to smooth voltage peaks
or to bridge commutating
dips. In addition, line commutating chokes reduce the
effects of harmonics on the
inverter and the power supply.
If the line impedance is < 1 %,
a line commutating choke
must be used in order to
reduce the current peaks.

Output chokes can be


supplied for reducing the
capacitive currents and dV/dt
in the case of motor cables
> 50 m (shielded) or
> 100 m (unshielded).

In line with the EN 61 000-3-2


regulations Limits for harmonic currents with device
input current 16 A per
phase, there are special
aspects for drives with 250 W
to 550 W and 230-V singlephase supplies which can be
used in non-industrial applications (1st environment).

For devices with 250 W and


370 W it is necessary either to
fit the recommended input
chokes or to apply to the
power utility company for
authorization to connect the
devices to the public power
supply.
No limits are currently defined
in the EN 61 000-3-2 standard
for professionally used
devices with a connected load
> 1 kW. This means that the
inverters with an output power
0.75 kW comply with the
EN 61 000-3-2 standard.

Gland plate
Gland plates are available for
inverters with frame sizes A, B
and C. In frame sizes D and
above, the gland plates are
integrated.
The gland plate enables
shielded connection of the
power and control cables,
ensuring optimum EMC
performance. This action
ensures compliance with the
NEMA 1 directive.

MICROMASTER 440
Options

Variant Independent Options


Basic Operator Panel (BOP)
With the BOP, individual
parameter settings can be
made. Values and units are
shown on a 5-digit display.

multiple inverter control, the


AOP permits bus communication with up to 30 inverters at a
transmission rate of 38 kbaud
(RS485, USS).
For servicing purposes, the
AOP furthermore supports the
download & upread of complete parameter sets.
PROFIBUS module

Basic Operator Panel (BOP)

A BOP can be used for several


inverters. It can be directly
mounted on the inverter or in a
control-cabinet door using a
mounting kit.
Advanced Operator Panel
(AOP)
The AOP enables
MICROMASTER 440 parameter sets to be easily read and
modified. In contrast to the
BOP, the value and meaning
of the parameters can be
directly displayed in several
languages by fast scrolling of
the address.

For a complete PROFIBUS


connection with up to
12 Mbaud. Remote control of
the inverter is possible with the
PROFIBUS module. Remote
control and operation at the
inverter can be combined
using an operator panel
plugged onto the PROFIBUS
module. The latter can be supplied by an external 24 V DC
power supply and is thus also
active when the inverter is disconnected from the mains.
Connection by means of a
9-pin Sub-D connector
(available as an accessory).
DeviceNet module
For networking the inverters to
the DeviceNet fieldbus system
widely used on the American
market. A max. transmission
rate of 500 kbaud is possible.
Remote control of the module
is possible via the DeviceNet
module. Remote control and
operation on the inverter can
be combined using an operator panel connected to the
DeviceNet module.
The connection to the
DeviceNet bus system is
made using a 5-pin connector
with terminal strip.

Pulse encoder evaluation


module

Operator panel door mounting kit for single inverter

The pulse encoder evaluation


module permits direct connection of the most widely
encountered digital pulse
encoders to the inverter.

For mounting an operator


panel in a control cabinet
door. Degree of protection is
IP 56. Contains a cable
adapter board with screwless
terminals for use with the
users own cables.

They offer the following functions:


Zero speed at full load
torque
Extremely accurate speed
control
Increased dynamic
response of speed and
torque control.
This module can be used with
HTL and TTL pulse encoders
(High-voltage Transistor
Logic, 24 V and Transistortransistor Logic, 5 V).
Connection set for
PC to inverter

AOP door mounting kit for


multiple inverter (USS)
For mounting an AOP in a
control cabinet door. Degree
of protection IP 56. The AOP
can communicate with several
inverters by means of the
RS-485 USS protocol. The
4-pin connecting cable from
the AOP to the RS-485 terminals of the inverter and to the
24 V user terminal strip is not
included.
Commissioning tools

For controlling an inverter


directly from a PC if the appropriate software has been
installed (e.g. STARTER) in the
PC. Isolated RS-232 adapter
board for reliable point-topoint connection to a PC.
Includes a Sub-D connector
and an RS-232 standard cable
(3 m).
Connection set for
PC to AOP
For connecting a PC to an
AOP. Offline programming of
inverters and archiving of
parameter sets possible.
Includes a desktop attachment kit for an AOP, an RS-232
standard cable (3 m) with
Sub-D connectors and a
universal power supply unit.

STARTER
Starter is graphic start-up
software for guided commissioning for MICROMASTER
410/420/430/440 frequency
inverters under Windows
NT/2000. Parameter lists
can be read out, altered,
stored, entered and printed.
DriveMonitor
DriveMonitor is start-up
software for list-oriented
programming of frequency
inverters under Windows
95/98/NT/2000.
Both programs are included
on the Docu CD which is
provided with every inverter.

Advanced Operator Panel (AOP)

The AOP is directly plugged


into the inverter, or communicates with the latter via a door
mounting kit. Together with the
AOP door mounting kit for

Siemens DA 51.2 October 2002

4/13

MICROMASTER 440
Options

Ordering Data for Variant Dependent Options


The options listed here
(filters, chokes, brake resistors, gland plates, fuses and
circuit breakers) are inverter
specific.
Mains
operating
voltage
200 V to
240 V 1 AC

200 V to
240 V 3 AC

380 V to
480 V 3 AC

500 V to
600 V 3 AC

4/14

Rated
output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
0.75
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75

The inverter and the associated options have the same


voltage ratings.

Inverter
without filter
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC24-0CA1
6SE6440-2UC25-5CA1
6SE6440-2UC27-5DA1
6SE6440-2UC31-1DA1
6SE6440-2UC31-5DA1
6SE6440-2UC31-8EA1
6SE6440-2UC32-2EA1
6SE6440-2UC33-0FA1
6SE6440-2UC33-7FA1
6SE6440-2UC34-5FA1
6SE6440-2UD13-7AA1
6SE6440-2UD15-5AA1
6SE6440-2UD17-5AA1
6SE6440-2UD21-1AA1
6SE6440-2UD21-5AA1
6SE6440-2UD22-2BA1
6SE6440-2UD23-0BA1
6SE6440-2UD24-0BA1
6SE6440-2UD25-5CA1
6SE6440-2UD27-5CA1
6SE6440-2UD31-1CA1
6SE6440-2UD31-5DA1
6SE6440-2UD31-8DA1
6SE6440-2UD32-2DA1
6SE6440-2UD33-0EA1
6SE6440-2UD33-7EA1
6SE6440-2UD34-5FA1
6SE6440-2UD35-5FA1
6SE6440-2UD37-5FA1
6SE6440-2UD38-8FA0
6SE6440-2UD41-1FA0
6SE6440-2UD41-3GA0
6SE6440-2UD41-6GA0
6SE6440-2UD42-0GA0
6SE6440-2UE17-5CA1
6SE6440-2UE21-5CA1
6SE6440-2UE22-2CA1
6SE6440-2UE24-0CA1
6SE6440-2UE25-5CA1
6SE6440-2UE27-5CA1
6SE6440-2UE31-1CA1
6SE6440-2UE31-5DA1
6SE6440-2UE31-8DA1
6SE6440-2UE32-2DA1
6SE6440-2UE33-0EA1
6SE6440-2UE33-7EA1
6SE6440-2UE34-5FA1
6SE6440-2UE35-5FA1
6SE6440-2UE37-5FA1

Siemens DA 51.2 October 2002

All options are certified


to u, except fuses.
The fuses 3NE1 comply with
u (corresponds to U).

Order No. of the options


EMC filter
Class A

6SE6400-2FA00-6AD0

EMC filter
Class B

6SE6400-2FB00-6AD0

6SE6400-2FA01-4BC0

6SE6400-2FB01-4BC0

6SE6400-2FA00-6AD0

6SE6400-2FB00-6AD0

6SL3000-0BE32-5AA0
6SL3000-0BE34-4AA0

6SL3000-0BE36-0AA0

Filter Class B with


low leakage
6SE6400-2FL01-0AB0

6SE6400-2FL02-6BB0

MICROMASTER 440
Options

Ordering Data for Variant Dependent Options (continued)

Mains
operating
voltage
200 V to
240 V 1 AC

200 V to
240 V 3 AC

380 V to
480 V 3 AC

500 V to
600 V 3 AC

Rated
output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
0.75
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75

Inverter
without filter
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC24-0CA1
6SE6440-2UC25-5CA1
6SE6440-2UC27-5DA1
6SE6440-2UC31-1DA1
6SE6440-2UC31-5DA1
6SE6440-2UC31-8EA1
6SE6440-2UC32-2EA1
6SE6440-2UC33-0FA1
6SE6440-2UC33-7FA1
6SE6440-2UC34-5FA1
6SE6440-2UD13-7AA1
6SE6440-2UD15-5AA1
6SE6440-2UD17-5AA1
6SE6440-2UD21-1AA1
6SE6440-2UD21-5AA1
6SE6440-2UD22-2BA1
6SE6440-2UD23-0BA1
6SE6440-2UD24-0BA1
6SE6440-2UD25-5CA1
6SE6440-2UD27-5CA1
6SE6440-2UD31-1CA1
6SE6440-2UD31-5DA1
6SE6440-2UD31-8DA1
6SE6440-2UD32-2DA1
6SE6440-2UD33-0EA1
6SE6440-2UD33-7EA1
6SE6440-2UD34-5FA1
6SE6440-2UD35-5FA1
6SE6440-2UD37-5FA1
6SE6440-2UD38-8FA0
6SE6440-2UD41-1FA0
6SE6440-2UD41-3GA0
6SE6440-2UD41-6GA0
6SE6440-2UD42-0GA0
6SE6440-2UE17-5CA1
6SE6440-2UE21-5CA1
6SE6440-2UE22-2CA1
6SE6440-2UE24-0CA1
6SE6440-2UE25-5CA1
6SE6440-2UE27-5CA1
6SE6440-2UE31-1CA1
6SE6440-2UE31-5DA1
6SE6440-2UE31-8DA1
6SE6440-2UE32-2DA1
6SE6440-2UE33-0EA1
6SE6440-2UE33-7EA1
6SE6440-2UE34-5FA1
6SE6440-2UE35-5FA1
6SE6440-2UE37-5FA1

Order No. of the options


Line commutating
choke
6SE6400-3CC00-4AB0

Output choke

Brake resistor

6SE6400-3TC00-4AD1

6SE6400-4BC05-0AA0

6SE6400-3CC02-6BB0

6SE6400-3TC01-0BD0

6SE6400-4BC11-2BA0

6SE6400-3CC03-5CB0
6SE6400-3CC00-3AC0

6SE6400-3TC03-2CD0
6SE6400-3TC00-4AD1

6SE6400-4BC12-5CA0
6SE6400-4BC05-0AA0

6SE6400-3CC00-8BC0
6SE6400-3CC01-4BD0

6SE6400-3TC01-0BD0

6SE6400-4BC11-2BA0

6SE6400-3CC01-7CC0
6SE6400-3CC03-5CD0

6SE6400-3TC03-2CD0

6SE6400-4BC12-5CA0
6SE6400-4BC13-0CA0

6SE6400-3CC05-2DD0

6SE6400-3TC02-8DC0
6SE6400-3TC05-4DD0

6SE6400-4BC18-0DA0

6SE6400-3CC08-8EC0

6SE6400-3TC08-0ED0

6SE6400-4BC21-2EA0

6SE6400-3CC11-7FD0

6SE6400-3TC15-4FD0

6SE6400-4BC22-5FA0

6SE6400-3CC00-2AD0

6SE6400-4BD11-0AA0

6SE6400-3CC00-4AD0

6SE6400-3TC01-0BD0
(not suitable for footprint
mounting)

6SE6400-3CC00-6AD0
6SE6400-3CC01-0BD0

6SE6400-3TC01-0BD0

6SE6400-4BD12-0BA0

6SE6400-3CC01-4BD0
6SE6400-3CC02-2CD0

6SE6400-3TC03-2CD0

6SE6400-4BD16-5CA0

6SE6400-3TC05-4DD0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC08-0ED0
6SE6400-3TC07-5ED0
6SE6400-3TC14-5FD0
6SE6400-3TC15-4FD0
6SE6400-3TC14-5FD0
in preparation

6SE6400-4BD21-2DA0

6SE6400-3CC01-0AB0

6SE6400-3CC00-5AC0

6SE6400-3CC03-5CD0
6SE6400-3CC04-4DD0
6SE6400-3CC05-2DD0
6SE6400-3CC08-3ED0
6SE6400-3CC11-2FD0
6SE6400-3CC11-7FD0
6SL3000-0CE32-3AA0
6SL3000-0CE32-8AA0
6SL3000-0CE33-3AA0
6SL3000-0CE35-1AA0

6SE6400-3CC04-4DD0
6SE6400-3CC08-3ED0
6SE6400-3CC11-2FD0

On request

6SE6400-4BD22-2EA0
6SE6400-4BD24-0FA0

6SE6400-4BE14-5CA0

6SE6400-4BE16-5CA0
6SE6400-3TC02-2DE0
6SE6400-3TC02-7DE0
6SE6400-3TC03-2DE0
6SE6400-3TC05-2EE0

6SE6400-4BE21-3DA0

6SE6400-3TC06-2FE0
6SE6400-3TC08-8FE0

6SE6400-4BE24-2FA0

6SE6400-4BE21-8EA0

Siemens DA 51.2 October 2002

4/15

MICROMASTER 440
Options

Ordering Data for Variant Dependent Options (continued)


l Use in America

requires u-listed
fuses such as e.g.
the Class NON range
from Bussmann.

Mains
operating
voltage
200 V to
240 V 1 AC

200 V to
240 V 3 AC

380 V to
480 V 3 AC

500 V to
600 V 3 AC

4/16

Rated
output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75
90
110
132
160
200
0.75
1.5
2.2
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75

Inverter
without filter

Order No. of the options


Gland plate

6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC11-2AA1
6SE6440-2UC12-5AA1
6SE6440-2UC13-7AA1
6SE6440-2UC15-5AA1
6SE6440-2UC17-5AA1
6SE6440-2UC21-1BA1
6SE6440-2UC21-5BA1
6SE6440-2UC22-2BA1
6SE6440-2UC23-0CA1
6SE6440-2UC24-0CA1
6SE6440-2UC25-5CA1
6SE6440-2UC27-5DA1
6SE6440-2UC31-1DA1
6SE6440-2UC31-5DA1
6SE6440-2UC31-8EA1
6SE6440-2UC32-2EA1
6SE6440-2UC33-0FA1
6SE6440-2UC33-7FA1
6SE6440-2UC34-5FA1
6SE6440-2UD13-7AA1
6SE6440-2UD15-5AA1
6SE6440-2UD17-5AA1
6SE6440-2UD21-1AA1
6SE6440-2UD21-5AA1
6SE6440-2UD22-2BA1
6SE6440-2UD23-0BA1
6SE6440-2UD24-0BA1
6SE6440-2UD25-5CA1
6SE6440-2UD27-5CA1
6SE6440-2UD31-1CA1
6SE6440-2UD31-5DA1
6SE6440-2UD31-8DA1
6SE6440-2UD32-2DA1
6SE6440-2UD33-0EA1
6SE6440-2UD33-7EA1
6SE6440-2UD34-5FA1
6SE6440-2UD35-5FA1
6SE6440-2UD37-5FA1
6SE6440-2UD38-8FA0
6SE6440-2UD41-1FA0
6SE6440-2UD41-3GA0
6SE6440-2UD41-6GA0
6SE6440-2UD42-0GA0
6SE6440-2UE17-5CA1
6SE6440-2UE21-5CA1
6SE6440-2UE22-2CA1
6SE6440-2UE24-0CA1
6SE6440-2UE25-5CA1
6SE6440-2UE27-5CA1
6SE6440-2UE31-1CA1
6SE6440-2UE31-5DA1
6SE6440-2UE31-8DA1
6SE6440-2UE32-2DA1
6SE6440-2UE33-0EA1
6SE6440-2UE33-7EA1
6SE6440-2UE34-5FA1
6SE6440-2UE35-5FA1
6SE6440-2UE37-5FA1

6SE6400-0GP00-0AA0

Siemens DA 51.2 October 2002

Fuse (see Catalog NS K)


3NA3
3NE1 (U)
l
3NA3803
3NA3805

6SE6400-0GP00-0BA0

3NA3807

6SE6400-0GP00-0CA0
6SE6400-0GP00-0AA0

3NA3810
3NA3812
3NA3803

3NA3805
6SE6400-0GP00-0BA0

3NA3807
3NA3810

6SE6400-0GP00-0CA0
Integrated as standard

3NA3812
3NA3814
3NA3820
3NA3824
3NA3830

3NE1817-0
3NE1820-0

3NA3836
3NA3140

3NE1021-0
3NE1022-0
3NE1224-0
3NE1225-0

6SE6400-0GP00-0AA0

3NA3003

6SE6400-0GP00-0BA0

3NA3005
3NA3007

6SE6400-0GP00-0CA0
Integrated as standard

6SE6400-0GP00-0CA0

Integrated as standard

3NA3012
3NA3014
3NA3020
3NA3022
3NA3024
3NA3030
3NA3032
3NA3036
3NA3140

3NA3803-6

3NE1817-0
3NE1818-0
3NE1820-0
3NE1021-0
3NE1022-0
3NE1224-0
3NE1225-0
3NE1227-0
3NE1230-0
3NE1332-0
3NE1333-0
3NE1435-0

3NA3805-6
3NA3810-6
3NA3812-6
3NA3814-6
3NA3820-6
3NA3822-6
3NA3824-6

3NE1803-0
3NE1817-0
3NE1818-0
3NE1820-0

3NA3132-6

3NE1022-0

3NA3136-6

3NE1224-0

Circuit-breakers
(see Catalog NS K)
3RV1021-1DA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1021-1BA10
3RV1021-1DA10
3RV1021-1FA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4CA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4JA10
3RV1042-4LA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
3RV1021-1CA10
3RV1021-1DA10
3RV1021-1FA10
3RV1021-1GA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .
On request

3RV1021-1DA10
3RV1021-1GA10
3RV1021-1JA10
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4DA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4JA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .

MICROMASTER 440
Options

Ordering Data for Variant Dependent Options (continued)

Mains
operating
voltage
200 V to
240 V 1 AC

200 V to
240 V 3 AC
380 V to
480 V 3 AC

Mains
operating
voltage
200 V to
240 V 1 AC

200 V to
240 V 3 AC
380 V to
480 V 3 AC

Rated
output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75

Inverter
with internal filter
Class A
6SE6440-2AB11-2AA1
6SE6440-2AB12-5AA1
6SE6440-2AB13-7AA1
6SE6440-2AB15-5AA1
6SE6440-2AB17-5AA1
6SE6440-2AB21-1BA1
6SE6440-2AB21-5BA1
6SE6440-2AB22-2BA1
6SE6440-2AB23-0CA1
6SE6440-2AC23-0CA1
6SE6440-2AC24-0CA1
6SE6440-2AC25-5CA1
6SE6440-2AD22-2BA1
6SE6440-2AD23-0BA1
6SE6440-2AD24-0BA1
6SE6440-2AD25-5CA1
6SE6440-2AD27-5CA1
6SE6440-2AD31-1CA1
6SE6440-2AD31-5DA1
6SE6440-2AD31-8DA1
6SE6440-2AD32-2DA1
6SE6440-2AD33-0EA1
6SE6440-2AD33-7EA1
6SE6440-2AD34-5FA1
6SE6440-2AD35-5FA1
6SE6440-2AD37-5FA1

Rated
output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75

Inverter
with internal filter
Class A
6SE6440-2AB11-2AA1
6SE6440-2AB12-5AA1
6SE6440-2AB13-7AA1
6SE6440-2AB15-5AA1
6SE6440-2AB17-5AA1
6SE6440-2AB21-1BA1
6SE6440-2AB21-5BA1
6SE6440-2AB22-2BA1
6SE6440-2AB23-0CA1
6SE6440-2AC23-0CA1
6SE6440-2AC24-0CA1
6SE6440-2AC25-5CA1
6SE6440-2AD22-2BA1
6SE6440-2AD23-0BA1
6SE6440-2AD24-0BA1
6SE6440-2AD25-5CA1
6SE6440-2AD27-5CA1
6SE6440-2AD31-1CA1
6SE6440-2AD31-5DA1
6SE6440-2AD31-8DA1
6SE6440-2AD32-2DA1
6SE6440-2AD33-0EA1
6SE6440-2AD33-7EA1
6SE6440-2AD34-5FA1
6SE6440-2AD35-5FA1
6SE6440-2AD37-5FA1

Order No. of the options


Supplementary EMC filter
Class B
6SE6400-2FS01-0AB0

Line commutating
choke
6SE6400-3CC00-4AB0

Output choke
6SE6400-3TC00-4AD1

6SE6400-3CC01-0AB0

6SE6400-2FS02-6BB0

6SE6400-3CC02-6BB0

6SE6400-3TC01-0BD0

6SE6400-2FS03-5CB0
6SE6400-2FS03-8CD0

6SE6400-3CC03-5CB0
6SE6400-3CC01-7CC0
6SE6400-3CC03-5CD0

6SE6400-3TC03-2CD0
6SE6400-3TC03-2CD0

6SE6400-2FS01-6BD0

6SE6400-3CC01-0BD0

6SE6400-3TC01-0BD0

6SE6400-2FS03-8CD0

6SE6400-3CC01-4BD0
6SE6400-3CC02-2CD0

6SE6400-3TC03-2CD0

6SE6400-3CC03-5CD0
6SE6400-3CC04-4DD0
6SE6400-3CC05-2DD0
6SE6400-3CC08-3ED0
6SE6400-3CC11-2FD0
6SE6400-3CC11-7FD0

Order No. of the options


Brake resistor

Gland plate

6SE6400-4BC05-0AA0

6SE6400-0GP00-0AA0

6SE6400-4BC11-2BA0

6SE6400-0GP00-0BA0

6SE6400-4BC12-5CA0
6SE6400-4BC12-5CA0
6SE6400-4BC13-0CA0

6SE6400-0GP00-0CA0
6SE6400-0GP00-0CA0

6SE6400-4BD12-0BA0

6SE6400-0GP00-0BA0

6SE6400-4BD16-5CA0

6SE6400-0GP00-0CA0

6SE6400-4BD21-2DA0

Integrated as standard

6SE6400-3TC05-4DD0
6SE6400-3TC03-8DD0
6SE6400-3TC05-4DD0
6SE6400-3TC08-0ED0
6SE6400-3TC07-5ED0
6SE6400-3TC14-5FD0
6SE6400-3TC15-4FD0
6SE6400-3TC14-5FD0

6SE6400-4BD22-2EA0
6SE6400-4BD24-0FA0

Siemens DA 51.2 October 2002

4/17

MICROMASTER 440
Options

Ordering Data for Variant Dependent Options (continued)

Mains
operating
voltage
200 V to
240 V 1 AC

200 V to
240 V 3 AC
380 V to
480 V 3 AC

Rated
output
kW
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
3.0
4.0
5.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22
30
37
45
55
75

Inverter
with internal filter
Class A
6SE6440-2AB11-2AA1
6SE6440-2AB12-5AA1
6SE6440-2AB13-7AA1
6SE6440-2AB15-5AA1
6SE6440-2AB17-5AA1
6SE6440-2AB21-1BA1
6SE6440-2AB21-5BA1
6SE6440-2AB22-2BA1
6SE6440-2AB23-0CA1
6SE6440-2AC23-0CA1
6SE6440-2AC24-0CA1
6SE6440-2AC25-5CA1
6SE6440-2AD22-2BA1
6SE6440-2AD23-0BA1
6SE6440-2AD24-0BA1
6SE6440-2AD25-5CA1
6SE6440-2AD27-5CA1
6SE6440-2AD31-1CA1
6SE6440-2AD31-5DA1
6SE6440-2AD31-8DA1
6SE6440-2AD32-2DA1
6SE6440-2AD33-0EA1
6SE6440-2AD33-7EA1
6SE6440-2AD34-5FA1
6SE6440-2AD35-5FA1
6SE6440-2AD37-5FA1

Order No. of the options


Fuse (see Catalog NS K)
3NA3
3NE1 (U)
l
3NA3803

3NA3805
3NA3807
3NA3810
3NA3812
3NA3810
3NA3812
3NA3814
3NA3005

l
l

3NA3007
3NA3012
3NA3014
3NA3020
3NA3022
3NA3024
3NA3030
3NA3032
3NA3036
3NA3140

3NE1817-0
3NE1818-0
3NE1820-0
3NE1021-0
3NE1022-0
3NE1224-0
3NE1225-0

l Use in America

requires u-listed
fuses such as e.g.
the Class NON range
from Bussmann.

4/18

Siemens DA 51.2 October 2002

Circuit breaker
(see Catalog NS K)
3RV1021-1DA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1031-4EA10
3RV1031-4FA10
3RV1031-4HA10
3RV1042-4KA10
3RV1042-4MA10
3VL1712- . DD33- . . . .
3VL1716- . DD33- . . . .
3VL3720- . DC36- . . . .
3VL3725- . DC36- . . . .
3VL4731- . DC36- . . . .

MICROMASTER 440
Options

Ordering Data for Variant Independent Options


The options listed here are suitable
for all MICROMASTER 440 Inverters.
Options
Basic Operator Panel (BOP)
Advanced Operator Panel (AOP)
PROFIBUS module
DeviceNet module
Pulse encoder evaluation module
RS485/PROFIBUS bus connector
Connection set for PC to inverter
Connection set for PC to AOP
Operator panel door mounting kit for single inverter
AOP-door mounting kit for multiple inverter (USS)

Order No.
6SE6400-0BP00-0AA0
6SE6400-0AP00-0AA1
6SE6400-1PB00-0AA0
6SE6400-1DN00-0AA0
6SE6400-0EN00-0AA0
6GK1500-0FC00
6SE6400-1PC00-0AA0
6SE6400-0PA00-0AA0
6SE6400-0PM00-0AA0
6SE6400-0MD00-0AA0

Technical data of the communications modules


PROFIBUS module
6SE6400-1PB00-0AA0

Size (height x width x depth)


Degree of protection
Degree of pollution
Mechanical strength
Stationary
Transport

Deflection
Acceleration
Deflection
Acceleration

Climatic category (during operation)


Cooling method
Permissible ambient or cooling agent temperature
in operation
during storage and transport
Relative humidity (permissible humidity rating)
in operation
during storage and transport
Electromagnetic compatibility
Emission
Interference
radiation
Supply voltage

Output voltage

Data transmission rate

DeviceNet module
6SE6400-1DN00-0AA0

161 mm x 73 mm x 46 mm
IP 20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to DIN IEC 60 068-2-6 (if module installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to DIN IEC 60 721-3-3
Natural air cooling
10 C to +50 C (14 F to 122 F)
25 C to +70 C (13 F to 158 F)

85 % (non-condensing)
95 %
to EN 55 011 (1991) Class A
to IEC 60 801-3 and EN 61 000-4-3
6.5 V 5 %, max. 300 mA,
internal from inverter or
24 V 10 %, max. 350 mA, external
5 V 10 %, max. 100 mA,
galvanically isolated supply
for terminating the serial interface bus or
for supplying the OLP (Optical Link Plug)
max. 12 Mbaud

6.5 V 5 %, max. 300 mA


internal from inverter or
24 V, max. 60 mA from DeviceNet bus

125, 250 and 500 kbaud

Siemens DA 51.2 October 2002

4/19

MICROMASTER 440
Options

Variant Independent Options


Technical data of the pulse encoder evaluation module
Pulse encoder evaluation module
6SE6400-0EN00-0AA0

Size (height x width x depth)


Degree of protection
Degree of pollution
Mechanical strength
Stationary
Transport

Deflection
Acceleration
Deflection
Acceleration

Climatic category (during operation)


Cooling method
Permissible ambient or cooling agent temperature
in operation
during storage and transport
Electromagnetic compatibility
Emission
Interference
radiation
Relative humidity (permissible humidity rating)
in operation
during storage and transport
Supply voltage
Pulse frequency

161 mm x 73 mm x 42 mm
IP 20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
to DIN IEC 60 068-2-6 (if module installed correctly)
0.15 mm in the frequency range of 10 Hz to 58 Hz
19.6 m/s2 in the frequency range of >58 Hz to 500 Hz
3.5 mm in the frequency range of 5 Hz to 9 Hz
9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
3K3 to DIN IEC 60 721-3-3
Natural air cooling
10 C to +50 C (14 F to 122 F)
20 C to +70 C (14 F to 158 F)
to EN 55 011 (1991) Class A
to IEC 60 801-3 and EN 61 000-4-3

85 % (non-condensing)
95 %
5 V 5 %, 330 mA or 18 V non-regulated, 140 mA, short-circuit-proof
max. 300 kHz

Documentation
Type of documentation
Docu-Pack,
supplied with each inverter,
containing CD-ROM 1) and
Getting Started Guide 2)
(paper version)
Operating instruction2)
(paper version)

Parameter list 2)
(paper version)

1) The CD-ROM contains operating instructions, parameter


list, commissioning tools
STARTER and DriveMonitor,
multilanguage.

4/20

Language
Multilanguage

Order No.
6SE6400-5AD00-1AP0

German
English
French
Italian
Spanish
German
English
French
Italian
Spanish

6SE6400-5AW00-0AP0
6SE6400-5AW00-0BP0
6SE6400-5AW00-0DP0
6SE6400-5AW00-0CP0
6SE6400-5AW00-0EP0
6SE6400-5BB00-0AP0
6SE6400-5BB00-0BP0
6SE6400-5BB00-0DP0
6SE6400-5BB00-0CP0
6SE6400-5BB00-0EP0

2) Available on Internet at
http://www.siemens.com/
micromaster

Siemens DA 51.2 October 2002

MICROMASTER 440
Dimension Drawings

MICROMASTER 440 Inverter


Frame size

200 V to 240 V 1/3 AC

380 V to 480 V 3 AC

500 V to 600 V 3 AC

0.12 kW to 0.75 kW

0.37 kW to 1.5 kW

1.1 kW to 2.2 kW

2.2 kW to 4 kW

3 kW to 5.5 kW

5.5 kW to 11 kW

0.75 kW to 11 kW

The quoted outputs are


valid for CT operation.

73
(2.87)

Inverter frame size A

195 (7.68)

Fixing with
2 bolts M4, 2 nuts M4,
2 washers M4
or snap on to the DIN rail
Tightening torque with
washers fitted: 2.5 Nm
Ventilation clearance required
at top and bottom: 100 mm

ADA51-5007c

58
(2.28)
160 (6.29)

ADA51-5000e

DIN Rail

(5 149
.8
7)

147 (5.79)

173 (6.81)

Drill and fixing pattern

Inverter frame size A


with gland plate

ADA51-5008b

258 (10.16)

ADA51-5001d

202 (7,95)

174 (6.85)

Drill pattern

149 (5.87)

(6 172
.7
7)

138 (5.43)

Fixing with
4 bolts M4, 4 nuts M4,
4 washers M4
Tightening torque with
washers fitted: 2.5 Nm
Ventilation clearance required
at top and bottom: 100 mm

Inverter frame size B

Inverter frame size B


with gland plate

ADA51-5009b

309 (12.16)

ADA51-5002d

245 (9.65)

204 (8.03)

Drill pattern

(7 195
.6
8)

174 (6.85)

185 (7.28)

Inverter frame size C

Fixing with
4 bolts M5, 4 nuts M5,
4 washers M5
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance required
at top and bottom: 100 mm

Inverter frame size C


with gland plate

With a communications module, the mounting depth increases by 23 mm (0.91 Inches).


If a pulse encoder evaluation module is additionally inserted, the mounting depth is
All dimensions are in mm (values in brackets are in inches)
increased by a further 23 mm (0.91 Inches).

Siemens DA 51.2 October 2002

4/21

MICROMASTER 440
Dimension Drawings

MICROMASTER 440 Inverter (continued)


Frame size

380 V to 480 V 3 AC

500 V to 600 V 3 AC

200 V to 240 V 3 AC
7.5 kW to 15 kW

15 kW to 22 kW

15 kW to 22 kW

18.5 kW to 22 kW

30 kW to 37 kW

30 kW to 37 kW

30 kW to 45 kW

45 kW to 75 kW

45 kW to 75 kW

The quoted
outputs are valid
for CT operation.
Drill pattern

Inverter frame size D

616.4 (24.27)

650 (25.59)

Fixing with
4 bolts M8, 4 nuts M8,
4 washers M8
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance required
at top and bottom: 300 mm

275 (10.82)

235 (9.25)

(9 245
.6
5)

235 (9.25)

(9 245
.6
5)

275 (10.82)

ADA51-5021b

ADA51-5020b

486 (19.13)

520 (20.47)

Drill pattern

Fixing with
4 bolts M8, 4 nuts M8,
4 washers M8
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance required
at top and bottom: 300 mm

Inverter frame size E

Drill pattern

4/22

Siemens DA 51.2 October 2002

1110 (43.70)

1150 (45.28)

810 (31.89)

Fixing with
4 bolts M8, 4 nuts M8,
4 washers M8
Tightening torque with
washers fitted: 3.0 Nm
Ventilation clearance required
at top and bottom: 350 mm

300 (11.81)

Fixing with
4 bolts M8, 4 nuts M8,
350 (13.78)
4 washers M8
Tightening torque with
Inverter frame size F
with filter
washers fitted: 3.0 Nm
Ventilation clearance required
at top and bottom: 350 mm
All dimensions are in mm (values in brackets are in inches)
(1 320
2.
6)

350 (13.78)

Inverter frame size F


without filter

(1 320
2.
6)

300 (11.81)

ADA51-5023b

ADA51-5022b

850 (33.46)

Drill pattern

MICROMASTER 440
Dimension Drawings

Frame size

380 V to 480 V 3 AC

FX

90 kW to 110 kW

GX

132 kW to 200 kW

The quoted
outputs are valid
for CT operation.

Drill pattern

330 (13)

1 x 185 or 2 x 120
1 x 350 or 2 x 4/0
10 mm

225
(8.86)

(1 360
4.
2)

ADA51-5044a

1555 (61.22)

1475 (58.07)

275
(10.83)

Fixing with
4 bolts M8
4 nuts M8
4 washers M8
for connection to DIN rail
Tightening torque with
washers fitted: 13 Nm + 30 %
Ventilation clearance required
top:
250 mm
bottom:150 mm
front: 100 mm
Power connection
Max. cable cross-section mm2
AWG
Barrel lug to DIN 46 235

Inverter frame size FX


Drill pattern

ADA51-5043a

1875 (73.82)

1800 (70.87)

275
(10.83)

Fixing with
4 bolts M8
4 nuts M8
4 washers M8
for connection to DIN rail
Tightening torque with
washers fitted: 13 Nm + 30 %
Ventilation clearance required
top:
250 mm
bottom:150 mm
front: 100 mm
Power connection
Max. cable cross-section mm2
AWG
Barrel lug to DIN 46 235

4
2 x 240
2 x 400
10 mm

(2 560
2.
5)

225
(8.86)

330 (13)

Inverter frame size GX

All dimensions are in mm (values in brackets are in inches)

Siemens DA 51.2 October 2002

4/23

MICROMASTER 440
Dimension Drawings

Filters

23.5
(0.93)

73
56

(2.87)
(2.2)

24
(0.94)

185 (7.28)
156 (6.14)

38
(1.5)

149 (5.87)
120 (4.72)

4 x M5

42.5 (1.67)

Filter for frame size A

138
(5.43)

for frame size B

49.5 (1.95)

219 (8.62)
232 (9.13)
ADA51-5012c

245 (9.65)
204 (8.03)

ADA51-5011c

213 (8.39)
174 (6.85)

174 (6.85)
187 (7.36)

ADA51-5010e

200 (7.87)
160 (6.3)

187 (7.36)
200 (7.87)

4 x M4
2 x M4

174
(6.85)

54 (2.13)

for frame size C

All dimensions are in mm (values in brackets are in inches)

4/24

Siemens DA 51.2 October 2002

MICROMASTER 440
Dimension Drawings

Line commutating chokes


c

Line commutating
choke for

Dimensions
a
200
(7.87)
213
(8.39)
245
(9.65)

DA51-5014d

DA51-5013e

frame size A

Line commutating choke for frame size A

frame size B
frame size C

b
75.5
(2.97)
150
(5.91)
185
(7.28)

Weight
(max.)
kg
0.8

c
50
(1.97)
50
1.3
(1.97)
50
2.3
(1.97)

for frame sizes B and C

Line commutating
choke for

a
520
(20.47)
650
(25.59)

DA51-5051

Dimensions

frame size D
frame size E

b
275
(10.83)
275
(10.83)

c
85
(3.35)
95
(3.74)

Weight
(max.)
kg
9.5
17.0

Line commutating choke for frame sizes D and E


b

DA51-5052

Line commutating choke


Type
6SE6400-

for
inverter
frame size
(FS)

3CC11-....

Line commutating choke


Type
6SL3000-

for
inverter
frame size
(FS)

0CE32-....

FX

0CE33-....

GX

0CE35-....

GX

n1

n2

Dimensions

a
210
(8.27)

Weight
(max.)

b
240
(9.45)

c
141
(5.55)

n1
109
(4.29)

n2
190
(7.48)

kg
25.0

Line commutating choke for inverter frame size F


b

DA51-5053

n1

Dimensions

a
248
(9.76)
248
(9.76)
269
(10.59)

Weight
(max.)

b
255
(10.04)
255
(10.04)
275
(10.83)

c
203
(7.99)
203
(7.99)
210
(8.27)

n1
101
(3.98)
101
(3.98)
118
(4.65)

n2
200
(7.87)
200
(7.87)
224
(8.82)

kg
24.0
25.0
35.0

n2

Line commutating choke for inverter frame sizes FX and GX

All dimensions are in mm (values in brackets are in inches)

Siemens DA 51.2 October 2002

4/25

MICROMASTER 440
Dimension Drawings

Output chokes
b

Output choke
Type 6SE6400-

Dimensions
a
200
(7.87)
213
(8.39)
245
(9.65)

DA51-5050

DA51-5049

3TC00-4AD1

Output choke
6SE6400-3TC00-4AD1

3TC03-2DC0

c
50
(1.97)
70
3.4
(2.76)
80
5.6
(3.15)

6SE6400-3TC01-0BD0
6SE6400-3TC03-1CD0

Figure 1

Figure 2

Output choke
Type 6SE6400-

DA51-5054

n2 /n4

DA51-5052

3TCD1-0BD0

b
75.5
(2.97)
150
(5.91)
185
(7.28)

Weight
(max.)
kg
0.8

n1 /n3

for inverter

n1

n2

Figure
No.

frame size
(FS)
3TC02-2DE0

3TC02-7DE0

3TC02-8DC0

3TC03-2DE0

3TC03-8DD0

3TC05-2EE0

3TC05-4DD0

3TC06-2FE0

3TC07-5ED0

3TC08-0ED0

3TC08-8FE0

3TC14-5FD0

3TC15-4FD0

Dim.

a
122
(4.80)
139
(5.47)
122
(4.80)
210
(8.27)
210
(8.27)
159
(6.26)
210
(8.27)
269
(10.59)
248
(9.76)
210
(8.27)
321
(12.64)
321
(12.64)
210
(8.27)

Weight
(max.)
b
124
(4.88)
148
(5.83)
124
(4.88)
225
(8.86)
225
(8.86)
178
(7.01)
225
(8.86)
300
(11.81)
270
(10.63)
225
(8.86)
350
(13.78)
350
(13.78)
225
(8.86)

c
73
(2.87)
78
(3.07)
73
(2.87)
179
(7.05)
179
(7.05)
73
(2.87)
150
(5.91)
220
(8.66)
209
(8.23)
150
(5.91)
288
(11.34)
288
(11.34)
150
(5.91)

to DIN 41 308
n1
n2
1
42
)
(1.65)
49
90
(1.93)
(3.54)
1
42
)
(1.65)
76
176
(2.99)
(6.93)
76
176
(2.99)
(6.93)
49
113
(1.93)
(4.45)
76
176
(2.99)
(6.93)
100
224
(3.94)
(8.82)
88
200
(3.46)
(7.87)
76
176
(2.99)
(6.93)
120
264
(4.72)
(10.39)
120
264
(4.72)
(10.39)
76
176
(2.99)
(6.93)

to DIN EN 60 852-4
n3
n4
53
112
(2.09)
(4.41)
58
136
(2.28)
(5.35)
53
112
(2.09)
(4.41)

kg
1.2
2.5
1.3
16.0

16.1

53
(2.09)

166
(6.54)

10.7

33.9

24.9

10.4

51.5

51.5

11.2

3.3

1) Mounting slot in center of foot.


Output choke for inverter frame sizes D, E and F

4/26

Siemens DA 51.2 October 2002

All dimensions are in mm (values in brackets are in inches)

MICROMASTER 440
Dimension Drawings

Brake resistors
Figure 1

Figure 2

n4
b

Figure 3

b
n4

b
n4

DA51-5069

DA51-5055a

n3
a

n3
a

DA51-5056

n3

c1

n1

c0

n2

Brake resistor
Type 6SE6400-

for inverter
frame size
(FS)

Fig.
No.

4BC05-0AA0

4BC11-2BA0

4BC12-5CA0

4BC13-0CA0

4BC18-0DA0

4BC21-2EA0

4BC22-5FA0

4BD11-0AA0

4BD12-0BA0

4BD16-5CA0

4BD21-2DA0

4BD22-2EA0

4BD24-0FA0

4BE14-5CA0

4BE16-5CA0

4BE21-3DA0

4BE21-8EA0

4BE24-2FA0

Dim.
a
230
(9.06)
239
(9.41)
285
(11.22)
285
(11.22)
515
(20.28)
645
(25.39)
650
(25.59)
230
(9.06)
239
(9.41)
285
(11.22)
515
(20.28)
645
(25.39)
650
(25.59)
285
(11.22)
285
(11.22)
515
(20.28)
645
(25.39)
650
(25.59)

Brake resistors for inverter frame sizes A to F

b
72
(2.83)
149
(5.87)
185
(7.28)
185
(7.28)
270
(10.63)
270
(10.63)
400
(15.75)
72
(2.83)
149
(5.87)
185
(7.28)
270
(10.63)
270
(10.63)
400
(15.75)
185
(7.28)
185
(7.28)
270
(10.63)
270
(10.63)
400
(15.75)

for console mounting for wall mounting


c
c0
c1
n1
n2
n3
n4
43.5

217
56
(1.71)
(8.54)
(2.20)
43.5

226
138
(1.71)
(8.90)
(5.43)
150
185
217
170
145
200
230
(5.91)
(7.28)
(8.54)
(6.69)
(5.71)
(7.87)
(9.06)
150
185
217
170
145
200
230
(5.91)
(7.28)
(8.54)
(6.69)
(5.71)
(7.87)
(9.06)
175
210
242
195
205
350
315
(6.89)
(8.27)
(9.53)
(7.68)
(8.07)
(13.78) (12.40)
175
210
242
195
205
480
315
(6.89)
(8.27)
(9.53)
(7.68)
(8.07)
(18.90) (12.40)
315
382
382
335
270
510
435
(12.40) (15.04) (15.04) (13.19) (10.63)
(20.08) (17.13)
43.5

217
56
(1.71)
(8.54)
(2.20)
43.5

226
138
(1.71)
(8.90)
(5.43)
150
185
217
170
145
200
230
(5.91)
(7.28)
(8.54)
(6.69)
(5.71)
(7.87)
(9.06)
175
210
242
195
205
350
315
(6.89)
(8.27)
(9.53)
(7.68)
(8.07)
(13.78) (12.40)
175
210
242
195
205
480
315
(6.89)
(8.27)
(9.53)
(7.68)
(8.07)
(18.90) (12.40)
315
382
382
335
270
510
435
(12.40) (15.04) (15.04) (13.19) (10.63)
(20.08) (17.13)
150
185
217
170
145
200
230
(5.91)
(7.28)
(8.54)
(6.69)
(5.71)
(7.87)
(9.06)
150
185
217
170
145
200
230
(5.91)
(7.28)
(8.54)
(6.69)
(5.71)
(7.87)
(9.06)
175
210
242
195
205
350
315
(6.89)
(8.27)
(9.53)
(7.68)
(8.07)
(13.78) (12.40)
175
210
242
195
205
480
315
(6.89)
(8.27)
(9.53)
(7.68)
(8.07)
(18.90) (12.40)
315
382
382
335
270
510
435
(12.40) (15.04) (15.04) (13.19) (10.63)
(20.08) (17.13)

Weight
(max.)
kg
1.0
1.6
3.8
3.8

7.4
10.6
16.7
1.0
1.6
3.8
7.4
10.6
16.7
3.8
3.8
7.4
10.6
16.7

All dimensions are in mm (values in brackets are in inches)

Siemens DA 51.2 October 2002

4/27

MICROMASTER 440
Dimension Drawings

DA51-5016b

Assembly of inverter and options

Example:
Assembly of inverter, choke
and filter
If additional accessories
are required, they must be
mounted at the side.

4/28

Siemens DA 51.2 October 2002

MICROMASTER
410/420/430/440
Appendix
A/2

Environment, Resources and Recycling

A/3

Certificates ISO 9001

A/4

Conformity with Standards

A/6

Demonstration Case

A/7

Training Center
Training Courses

A/8

Overview of Motors

A/10

Siemens European Companies and


Representatives

A/11

Siemens Companies and


Representatives Worldwide

A/13

Online Services

A/14

Service and Support

A/15

Subject Index

A/16

Order No. Index


Note for ordering

A/17

Conditions of Sale and Delivery


Export Regulations

Siemens DA 51.2 October 2002

A/1

MICROMASTER 410/420/430/440
Appendix

Environment, Resources and Recycling


Siemens AG feels a responsibility to play a role in protecting our environment and
saving our valuable natural
resources. This is true for both
our production and our products.
Even during development, we
consider any possible environment impact of future products/systems. Our aim is to
prevent harmful environment
effects, or at least to reduce
them to an absolute minimum
beyond present regulations
and legislation.

The most important activities


for protecting our environment
are as follows:
We are constantly endeavoring to reduce the environmental impact of our
products, as well as their
consumption of energy and
resources, over and above
the statutory environmental
protection regulations.
We take every possible
step to prevent damage to
the environment.
Environmental impact is
assessed and considered
at the earliest possible
stage of product and process planning.

A/2

Siemens DA 51.2 October 2002

Our optimized environmen-

We urge our business

tal management strategy


ensures that our environment policy is put into
practice effectively. The
necessary technical and
organizational procedures
are reviewed at regular
intervals and continuously
updated.
An awareness for environmental problems is expected of all our employees.
Establishing and furthering
a sense of responsibility for
the environment on all levels represents a permanent
challenge for the corporate
management.

partners to act according


to the same environmental
principles as ourselves. We
cooperate with the responsible public authorities.
We inform interested members of the public about
the consequences of our
corporate policies for the
environment as well as our
achievements to the benefit
of the environment.
Our complete documentation is printed on chlorinefree bleached paper.

MICROMASTER 410/420/430/440
Appendix

Certificates ISO 9001

! " # $ % & % ! ' $ "


!"#$%&'(
!"#"$%&'"#()*)"+&(!,(&(!"&'-./,0%

#)*&*+,$ -%
-./0&1/)0+$1+2$!3)4*,
#/1+2132$!3)4*,
1#,2"0,2#,'!"#&3(#,4"&56
789:6;<&=#>,0?"0
@)(!&(!"&>-',()-0+&,+&>)+("A&)0&(!"&,00"B
*-#&(!"&+'-/"
7"+)?0&C&A"D">-/."0(E&/#-A2'()-0E&+,>"+&C&.,#F"()0?&,0A&+"#D)'"&-*
+(,0A,#A&A#)D"+&,0A&'2+(-."#8+/"')*)'&A"+)?0

!,+&)./>"."0("A&,0A&.,)0(,)0+&,

".15)/6$ 71+18*&*+/$ #6,/*&9


G0&,2A)(E&A-'2."0("A&)0&,&#"/-#(E&!,+&D"#)*)"A&(!,(&(!)+
H2,>)(%&.,0,?"."0(&+%+(".&*2>*)>>+&(!"&#"H2)#"."0(+
-*&(!"&*->>-@)0?&+(,0A,#AI

!:;$<;$:#=$>??@$A$B???
7"'".$"#&J666&"A)()-0

K!)+&'"#()*)',("&)+&D,>)A&20()>

J66;8658:J

L"#()*)',("&M"?)+(#,()-0&N-OI

666P;Q&RS

1#,0F*2#(&,.&S,)0E&T"#>)0

J66J8658:P

7#O8U0?O&VO&W"(#)'F

7)/>O8U0?O&3O&X")0>-(!
SGNGYUNY& 7UM=LKZM3

!"#$%&'($!*./,CD*$%*,*55,CD1E/$F.3$G*3/)E)F)*3.+8$40+$71+18*&*+/,6,/*&*+
78<6[PP& 1#,0F*2#(& ,.& S,)0E& G2?2+(83'!,0\83(#,4"& J:
78:6Q5Q& T"#>)0E& T2#??#,*"0+(#,4"& <
!"#$%&'"(
)**("+,$,"(#-.%
/0$
!"#$%&$'($)'$''
!"#$%&$'($)'$*'

Siemens DA 51.2 October 2002

A/3

MICROMASTER 410/420/430/440
Appendix

Conformity with Standards


CE Marking

The MICROMASTER inverters


comply with the requirements
of the low-voltage directive,
73/23/EEC and with correct
installation and selection
with the requirements of the
EMC directive 89/336/EEC. A
certificate can be provided on
request.
The inverters comply with the
following standards listed in
the EU gazette:
Low-voltage Directive
EN 60 204
Safety of machinery, electrical
equipment of machines
EN 50 178
Electronic equipment in electrical power installations.
Machine Directive
The inverters are suitable for
installation in machines.
Compliance with the machine
directive 89/392/EEC requires
a separate certificate of conformity. This must be furnished
by the plant constructor or the
installer of the machine.
EMC Directive
EN 61 800-3

Variable-speed electric drives


Part 3: EMC product standard
including special test procedure.

A/4

The modified EMC product


standard EN 61 800-3/A11 for
electrical drive systems is
valid since 01.01.2002. The
following comments apply to
the series 6SE6 frequency
inverters from Siemens:
The EMC product standard
EN 61 800-3/A11 does not
apply directly to a frequency
inverter but to a PDS (Power
Drive System) which comprises the complete circuitry, motor and cables in
addition to the inverter.
A frequency inverter must
therefore only be considered as a component which,
on its own, is not subject to
the EMC product standard
EN 61 800-3/A11. However,
the inverters Instruction
Manual specifies the conditions on how the product
standard can be complied
with if the frequency inverter
is completed into a PDS. The
EMC directive in the EU is
complied with for a PDS by
observance of the product
standard EN 61 800-3/A11
for PDS. The frequency
inverters on their own do not
generally require identification according to the EMC
directive.
The frequency inverters as
components on their own
are only classified as
Limited availability for
persons and users with the
necessary EMC knowledge.
They are not envisaged for
unlimited sale or as General
availability for users.
At this point it is necessary
to exactly differentiate
between the frequency
inverter and the PDS. A PDS
can certainly be envisaged
by the vendor for general
availability, and the standard must be applied
accordingly. On the other
hand, the components used
in the PDS may possibly not
be for General availability.

Siemens DA 51.2 October 2002

Since 01.01.2002, the


EMC product standard
EN 61 800-3/A11 also
defines, for the first time,
limits for conducted interference and radiated interference for the so-called
Second environment
(= industrial power supply
systems which do not supply households). Although
these limits lie below those
of filter Class A according to
EN 55 011, a PDS with an
unfiltered frequency inverter
of series 6SE6 nevertheless
does not comply with these
values, and therefore does
not meet the standard
EN 61 800-3/A11.
Using internal or external
filters and the installation
instructions included in the
documentation, the PDS
designed using the frequency inverters complies
with the product standard
EN 61 800-3/A11:
Unlimited sale with filters
of Class B to EN 55 011
in the first environment
(living accommodation
and industrial areas)
Limited sale and installation by EMC experts
with filters of Class A to
EN 55 011 in the first
environment plus warning
information,
With filters of Class A to
EN 55 011 in the second
environment (industrial
areas), where these filters
even significantly exceed
the requirements of
EN 61 800-3/A11.

A differentiation must be
made between the product
standards for electrical drive
systems (PDS) of the range
of standards EN 61 800-3/
A11 (of which Part 3/A11
covers EMC topics) and the
product standards for the
devices/systems/machines
etc. No changes will probably result in the practical use
of frequency inverters. Since
frequency inverters are
always part of a PDS, and
these are part of a machine,
the machine vendor must
observe various standards
depending on the type and
environment, e.g.
EN 61 000-3-2 for power
supply harmonics and
EN 55 011 for radio interferences. The product standard for PDS on its own is
therefore either insufficient
there or irrelevant.
With respect to the compliance of limits for power supply
harmonics, the EMC product
standard EN 61 800-3/A11 for
PDS refers to compliance with
the EN 61 000-3-2 and
EN 61 000-3-12 standards.

MICROMASTER 410/420/430/440
Appendix

Electromagnetic
Compatibility
No impermissible electromagnetic irradiation occurs if the
installation guidelines specific
to the product are correctly
observed.
EMC phenomenon
Standard/test
Emitted interference
EN 61 800-3
(1st environment 1))

The table below lists the measured results for emissions of


and immunity to interference
for MICROMASTER.

The inverters were installed


according to the guidelines
with shielded motor cables
and shielded control cables.

Relevant criteria

Limit value

Conducted via mains cable

150 kHz to 30 MHz

Emitted by the drive

30 MHz to 1 GHz

Unfiltered not tested


Internal/external filter:
General availability 2) (category C1):
limit complies with EN 55 011 Class B
(only applies to MICROMASTER 410)
Limited availability 3) (category C2):
limit complies with EN 55 011, Class A, Group 1
All devices:
Limited availability 3): limit complies with
EN 55 011 Group 1, Class A

ESD immunity
EN 61 000-4-2
ESD through air discharge
ESD through contact discharge
Electrical fields immunity
EN 61 000-4-3
Electrical field applied to unit
Burst interference immunity
EN 61 000-4-4
Applied to all cable terminations
Surge immunity
EN 61 000-4-5
Applied to mains cables
Immunity to RFI emissions, conducted
EN 61 000-4-6
Applied to mains, motor and control cables

Test level 3
Test level 3
Test level 3
26 MHz to 1 GHz

8 kV
6 kV
10 V/m

Test level 4

4 kV

Test level 3

2 kV

Test level 4
0.15 MHz to 80 MHz
80 % AM (1 kHz)

10 V

UL Listing
u and cu- listed power conversion
equipment type 5B33 in accordance with UL508C.
For use in pollution degree 2 environment.

A
1) 1st environment
(living accommodation,
business and industrial areas):
environment which includes
living accommodation and also
equipment which is directly
connected to a low-voltage
power supply system without
intermediate transformers,
where this system also supplies living accommodation.

2) General availability
Sales channel where installation is independent of the
customers or users EMC
knowledge.
Category C1:
Power Drive System (PDS) with
rated voltage < 1000 V.
For use in 1st environment.

3) Limited availability:
Sales channel where installation
is limited to dealers, customers
or users who either individually or together have technical
EMC knowledge.
Category C2:
Power Drive System (PDS) with
rated voltage < 1000 V.
When used in 1st environment,
installation and start-up only by
EMC experts.
Siemens DA 51.2 October 2002

A/5

MICROMASTER 410/420/430/440
Appendix

Demonstration Case
With the MICROMASTER 420
and 440 demonstration case,
one of these inverters can be
selected using a switch.
The inverters are equipped
with status display panels
(SDP). A BOP, AOP or other
options must be ordered
separately.
The demonstration case has
the following features:

2 inverters
(MICROMASTER 420 and
MICROMASTER 440)
Asynchronous motor 1LA7
from Siemens
Precise, mechanical brake
for demonstration of torque
control
Double voltage range (90 V
to 130 V and 190 V to 265 V)
Extremely rugged metal
case, particularly suitable
for traveling.

Demonstration case

Order No.

Weight, approx.
kg

MICROMASTER 420 and 440

6SE6400-0DC40-0AA0

15

Order No.

Weight, approx.

SIDEMO Demonstration Case System


The SIDEMO range of modular
demonstration case systems
also includes cases for the
MICROMASTER inverters.

The demonstration systems


are fitted in dark blue transport
cases (400 x 300 x 210 mm)
which can be stacked.

The MICROMASTER demonstration cases can be operated on their own or together


with other demonstration
systems such as e.g. LOGO!,
SIMATIC S7-200, SITOP DCUPS.

When expanding the


MICROMASTER 420/440
demonstration case by a
PROFIBUS module (not
included in delivery of case),
it is also possible to demonstrate the incorporation into
TIA when using the SIMATIC
S7-300 Compact and Touch
Panel TP170B demonstration
systems.

A
SIDEMO demonstration case

kg
MICROMASTER 410
including OP operator panel

6AG1062-1AA08-0AA0

10

MICROMASTER 420
including BOP operator panel

6AG1062-1AA02-0AA0

10

MICROMASTER 440
including BOP operator panel

6AG1062-1AA02-1AA1

10

MICROMASTER 440
including BOP operator panel
the motor is equipped with a load unit

6AG1062-1AA06-0AA0

10

MICROMASTER 440
including BOP operator panel and pulse encoder evaluation module
the motor is equipped with an encoder and a load unit

6AG1062-1AA07-0AA0

10

Further information available on the Internet at: http://www.siemens.com/sidemo

A/6

Siemens DA 51.2 October 2002

MICROMASTER 410/420/430/440
Appendix

Training Center
Siemens A&D Training Centers are located worldwide,
and offer the courses listed
below for MICROMASTER.
Individual course contents, or
training on site at customers,
can also be carried out.
Contact partner:
Every A&D Information and
Training Center in the regions
and the regional companies
in Germany:
Tel.: +49 (0) 911-895 32 02

Headquarters:
Siemens AG
Automation and Drives
Training Center
P.O. Box 48 48
D-90327 Nuremberg
Germany
E-mail:
A&D.Kursbuero@nbgm.
siemens.de
Phone:
+49 (0) 9 11-8 95-32 00
Fax:
+49 (0) 9 11-8 95-32 75

Training Courses
MICROMASTER 4
servicing, commissioning
SD-MM4 (2 days)
This course is aimed at
commissioning and servicing
engineers for the
MICROMASTER 4 drives. It
covers proper utilization of the
MICROMASTER 440 inverter
functionality, as well as that of
the MICROMASTER 420
inverter. This course is also
suitable for beginners, since it
can be adapted to provide
more in-depth knowledge if
required.
Course targets/contents:
Fundamentals of asynchronous motors
Fundamentals of inverters
Programming using BOP,
AOP
PC programs:
DriveMonitor/STARTER
Commissioning using V/f
characteristic and vector
control
Optional programming of
input and output terminals

Use of special functions


such as flying restart, DC
brakes

Commissioning of the
MICROMASTER inverter on
the PROFIBUS-DP

Computer based Training


(CBT) and Web based
Training (WBT)

Warnings and fault signals

Transmission of process
data and parameter values
(protocol, PNO profile)

Commissioning is carried out


in interactive mode using the
MICROMASTER 420 frequency inverter. In particular,
handling of the parameter keyboard is practically identical to
the original. The training time
is 3 to 4 hours depending on
the level of knowledge.

Practical exercises using


the field-proven demonstration cases.
MICROMASTER 4
communication
SD-MM4-COM (2 days)
This course is aimed at
commissioning and servicing
engineers working with the
MICROMASTER 4 on the
PROFIBUS-DP. Knowledge of
MICROMASTER and SIMATIC
S7 are prerequisites.
It imparts knowledge on the
concept of Totally Integrated
Automation (TIA).
Course targets/contents:
Fundamentals of PROFIBUS-DP with emphasis on
drive technology
Design of the PROFIBUS-DP
bus system
Configuration of a
PROFIBUS-DP network in
Step 7

PROFIBUS-DP with Motion


Control expansion (lateral
communication, equidistance, clock synchronization)
Block library

Contents:

Drive ES SIMATIC
Fault diagnostics of the drive
via the bus system
Practical exercises on the
MICROMASTER 440
demonstration cases and the
SIMATIC S7 demonstration
cases with CPU 315-2 DP.
Tip:
The course sometimes
directly follows the SD-MM4
course. Participants need
then only travel once.
Note:
This course handles the
DriveES SIMATIC block
library. The SD-MD-COM
course provides comprehensive information on alternatives such as loading/transfer
commands, system functions,
DVA-S7 blocks.

Asynchronous motors connected to power supply and


inverter
Overview of
MICROMASTER inverter
Electrical installation
Parameter input, structure of
parameter set
Rating plate of motor
Simple commissioning
Assignment of different
functions to the terminals.

You can find further information in the Catalog ITC or at


http://www.sitrain.com.

Siemens DA 51.2 October 2002

A/7

MICROMASTER 410/420/430/440
Appendix

Overview of Motors
Siemens motors are an ideal
supplement to the
MICROMASTER inverters.

The table provides an overview of the most common


types of motors from Siemens.

In addition to the motors listed


in the table, explosion-proof
motors, marine motors and
combustion gas motors are
also available.

Catalogs M 11 and M 15
contain the complete range of
products with ordering data,
technical details and explanations.

Motors with gray cast iron casing


Efficiency class

Motor type
Rating (4-pole)
Speed/torque

Voltage (at 50 Hz if not specified otherwise)


Size
Design

Casing
Degree of protection

*)

EPACT

1LG6
18.5-200 kW
Speed
rpm

1LA6**)
50-200 hp
Speed
rpm

3000
3600
1500
1800
1000
1200
750
60 Hz 460 V d
230/400 V d/*
400/690 V d/*
180-315
225-315
IM B3
IM B5
IM V1
IM B14 (sizes 100 to 160)
IM B35
Gray cast iron
IP 55 (IP 65, IP 56)

Example of 1LA6 motor


*) 1.1 kW to 90 kW, 2-pole and 4-pole
**) Successor type 1LG6

A/8

Siemens DA 51.2 October 2002

*)

1LA6
2.2-15 kW
Speed
rpm
3000
1500
1000
750
230/400 V d/*
400/690 V d/*
100-160

1LG4
18.5-200 kW

1LA8
250-1000 kW

400/690 V d/*
180-315

315-450
IM B3
IM V1
IM B35

IP 55 (IP 56)

MICROMASTER 410/420/430/440
Appendix

Motors with aluminium casing


*)

EPACT

*)

1LA9
0.06-30 kW
Speed
rpm

1LA9
0.08-40 hp
Speed
rpm

1LA7
0.06-15 kW
Speed
rpm

3000
1500
1000

3600
1800
1200

3000
1500
1000
750
230/400 V d/*
400/690 V d/*
56-160

230/400 V d/* 60 Hz 460 V d


400/690 V d/*
56-200
IM B3
IM B5
IM V1
IM B14 (sizes 56 to 160)
IM B35
Aluminium
IP 55 (IP 65, IP 56)

Example of motor 1LA7

1LA5
18.5-45 kW

180-225

Gear motors
Spur gear

Flat gear

Bevel gear

Spur worm gear

2KG11
0.09-7.5 kW
Torque
Nm

2KG12

2KG13

Torque
Nm

Torque
Nm

2KG14
0.12-7.5 kW
Torque
Nm

80-550

130-660

120-800

70-1400

230/400 V d/*; 500 V *


400/690 V d/*
63-132
Foot-mounting type
Flange-mounting type
Universal mounting type

Chilled casting
Aluminium
IP 55 (IP 65, IP 56)

Aluminium or gray cast iron

Example of spur gear motor 2KG11

*) 1.1 kW to 90 kW, 2-pole and 4-pole

Siemens DA 51.2 October 2002

A/9

MICROMASTER 410/420/430/440
Appendix

Siemens European Companies and Representatives

A/10

Siemens DA 51.2 October 2002

MICROMASTER 410/420/430/440
Appendix

Siemens Companies and Representatives Worldwide

Siemens DA 51.2 October 2002

A/11

MICROMASTER 410/420/430/440
Appendix

Siemens Companies and Representatives Worldwide

A/12

Siemens DA 51.2 October 2002

MICROMASTER 410/420/430/440
Appendix

A&D in the WWW


A detailed knowledge of the
range of products and services available is essential
when planning and configuring automation systems. It
goes without saying that this
information must always be
fully up-to-date.

Under the address


http://www.siemens.com/
automation
you will find everything you
need to know about products,
systems and services.

The Siemens Automation and


Drives Group (A&D) has therefore built up a comprehensive
range of information in the
World Wide Web, which offers
quick and easy access to all
data required.

Product Selection Using the Interactive Catalogs


Detailed information together
with convenient interactive
functions:
The interactive catalogs CA 01
and ET 01 cover more than
80,000 products and thus
provide a full summary of the
Siemens Automation and
Drives product base.
Here you will find everything
that you need to solve tasks in
the fields of automation,
switchgear, installation and
drives.
All information is linked into a
user interface which is easy to
work with and intuitive.

After selecting the product of


your choice you can order at
the press of a button, by fax or
by online link.
Information on the interactive
catalogs can be found in the
Internet under
http://www.siemens.com/
automation/ca01
or on CD-ROM.
Automation and Drives, CA 01
Order No.:
E86060-D4001-A110-B7-7600
Electrical installation
technology, ET 01
Order No.:
E86060-D8200-A107-A3-7600

Easy Shopping with the A&D Mall


The A&D Mall is the virtual
department store of Siemens
AG in the Internet. Here you
have access to a huge range
of products presented in
electronic catalogs in an
informative and attractive way.
Data transfer via EDIFACT
allows the whole procedure
from selection through ordering to tracking of the order to
be carried out online via the
Internet.

Numerous functions are available to support you.


For example, powerful search
functions make it easy to find
the required products, which
can be immediately checked
for availability. Customerspecific discounts and preparation of quotes can be carried
out online as well as order
tracking and tracing.
Please visit the A&D Mall
on the Internet under:
http://www.siemens.com/
automation/mall

Siemens DA 51.2 October 2002

A/13

MICROMASTER 410/420/430/440
Appendix

Customer Support Automation and Drives

Whether you need a service


expert or a spare part, a
product specialist for advice,
or if you just have a query, then
the Customer Support is the
address for you the team that
meets all your needs!

Helpline for Service and Support

Online Support

You need help but do not


know who to address. We take
care that help is on the way
quickly.

The helplines ensure that the


right specialist in your vicinity
will be of skilled assistance to
you. The Helpline e. g. for
Germany helps in German
and English 24 hours/day,
365 days/year.

Tel.: 0180 50 50 111

Our Online Support guarantees quick and efficient assistance around the clock,
worldwide and in five
languages.

FAQs, tips & tricks, downloads and news

http://www.siemens.com/
automation/service&support

The Online Support offers all


technical information:

Field Service

Spare Parts and Repairs

A
Technical Support

A/14

Useful programs and software

Your system is installed and


now you need quick on-site
help. We have the specialists
with the know-how you
require, worldwide and at
hand.

Thanks to our comprehensive


service network, we are able
to realize short response times
with competence, reliability,
and speed.

Our worldwide network of


local spare parts stocks and
repair centers react with
speed and reliable logistics.

For requests about repairs or


spare parts please call the
following telephone number
(in Germany):

Tel.: 0180 50 50 446

Competent, qualified and


experienced specialists
offer teleservice and video
conferencing for specific
problems.

in the United States

FreeContact the way to the


free Technical Support.

in Asia

Our network of dependencies


in Germany, the U.S. and
Singapore offers support
around the clock according to
the follow the sun principle
via FastContact the fast way
to the Technical Support:

in Europe (headquarter)
Technical advice for implementation of products, systems and solutions in automation and drive technology is
provided in German and
English.

Free manuals

Tel.: +49 (0)180 50 50 222


Fax: +49 (0)180 50 50 223
E-mail:
techsupport@ad.siemens.de

Siemens DA 51.2 October 2002

You can request an expert in


Germany 24 hours/day and
365 days/year.

Tel.: +1 423 461-2522


Fax: +1 423 461 2231
E-mail: simatic.hotline@
sea.siemens.com
Tel.: +65 740-7000
Fax: +65 740 7001
E-mail:
simatic@singnet.com.sg

Tel.: 0180 50 50 444


Of course we offer also
service contracts customized
to your requirements. Your
Siemens Office is always at
your disposal.

Outside the office hours and


on weekends, dial this number
for our spare parts stand-by
service.

Return call within two hours


guaranteed
around the clock
payment with SIMATIC card
Tel.: +49 (0)911 895 7777
Fax: +49 (0)911 895 7001

MICROMASTER 410/420/430/440
Appendix

Subject Index
MICROMASTER

MICROMASTER
410

420

430

440

Page

Page

Page

Page

A
AOP (advanced operator panel)
Applications
Assignment table for options

1/2
0/4

2/14
2/2
0/4

3/2
0/4

4/19
4/2
0/4

B
BOP (basic operator panel)
BOP-2 (basic operator panel)
Brake resistor (option)

2/14
-

3/12
-

4/19
4/15

C
CE marking
Chokes (option)
Circuit breaker (option)
Circuit diagrams
Communications modules
Conditions of sale and delivery
Conformity with standards

A/4
1/9
1/9
1/4
A/17
A/4

A/4
2/12
2/13
2/4
2/14
A/17
A/4

A/4
3/10
3/10
3/4
3/12
A/17
A/4

A/4
4/15
4/16
4/4
4/19
A/17
A/4

D
Demonstration case
Derating data
Description (inverter)
Description (options)
Design
DeviceNet module (option)
Dimension drawings
Documentation
Docu-Pack
DriveMonitor

A/6
1/6
1/2
1/8
1/2
1/10
1/9
1/9

A/6
2/7
2/2
2/9
2/2
2/14
2/16
2/15
2/15
2/10

A/6
3/7
3/2
3/9
3/2
3/12
3/14
3/13
3/13
3/9

A/6
4/7
4/2
4/12
4/2
4/19
4/21
4/20
4/20
4/13

E
Electromagnetic compatibility
EMC filter (option)
Environment, resources and recycling
Export regulations

A/4
1/9
A/2
A/17

A/4
2/11
A/2
A/17

A/4
3/11
A/2
A/17

A/4
4/14
A/2
A/17

F
Features
Filter (option)
Fuses (option)

1/3
1/9
1/9

2/3
2/11
2/13

3/3
3/11
3/10

4/3
4/14
4/16

G
General circuit diagram
Getting Started Guide
Gland plates (option)

1/4
1/9
-

2/4
2/15
2/13

3/4
3/13
3/10

4/4
4/20
4/16

I
Installation height (derating)
International standards
Internet (online services)
ISO 9001 certificate

1/7
1/2
A/13
A/3

2/7
2/2
A/13
A/3

3/7
3/2
A/13
A/3

4/8
4/2
A/13
A/3

L
Line commutating chokes (option)

1/9

2/12

3/10

4/15

410

420

430

440

Page

Page

Page

Page

M
Main characteristics
Mechanical features

1/2
1/3

2/2
2/3

3/2
3/3

4/2
4/3

N
Note for ordering

A/16

A/16

A/16

A/16

O
OP (operator panel)
Operating instructions
Operating temperature (derating)
Operator panels
Options
Ordering data (inverter)
Ordering data (options)
Output chokes (option)
Overview
Overview of motors

1/9
1/9
1/9
1/8
1/7
1/9
0/2
A/8

2/15
2/7
2/14
2/9
2/8
2/11
2/12
0/2
A/8

3/13
3/7
3/12
3/9
3/8
3/10
3/10
0/3
A/8

4/20
4/8
4/19
4/12
4/9
4/14
4/15
0/3
A/8

1/9
1/3
1/3
-

2/15
2/3
2/14
2/3
-

3/13
3/3
3/12
3/3
-

4/20
4/3
4/19
4/3
4/19

1/6

2/7

3/7

4/7

A/10
0/2

A/10
0/2

A/10
0/3

A/10
0/3

1/7

2/8

3/8

4/9

1/9
A/14
A/6
1/9
1/9
A/14

2/11
A/14
A/6
2/10
2/10
A/14

3/10
A/14
A/6
3/9
3/9
A/14

4/14
A/14
A/6
4/13
4/13
A/14

T
Technical data (inverter)
Technical data (options)
Terminal connection diagram
Training center
Training courses

1/6
1/5
A/7
A/7

2/6
2/14
2/5
A/7
A/7

3/6
3/12
3/5
A/7
A/7

4/6
4/19
4/5
A/7
A/7

U
UL certification

A/5

A/5

A/5

A/5

V
Variant dependent options
Variant independent options

1/9
1/9

2/11
2/14

3/10
3/12

4/14
4/19

P
Parameter list
Performance features
PROFIBUS module (option)
Protection features
Pulse encoder evaluation module
(option)
Pulse frequency (derating)
S
Sales regions
Selection aid
Selection and ordering data
(inverter)
Selection and ordering data
(options)
Service and support
SIDEMO (demonstration case system)
STARTER
Start-up software
Support

Siemens DA 51.2 October 2002

A/15

MICROMASTER 410/420/430/440
Appendix

Order No. Index

Note for ordering


Release versions/designs

MICROMASTER
410

420

430

440

Page

Page

Page

Page

1/9

2/13

3/10, 3/11

4/16, 4/18

3/10, 3/11

4/16, 4/18

1/9

2/13

3/10, 3/11

4/16, 4/18

3/10, 3/11

4/16, 4/18

6GK1500-0FC00

2/14

3/12

4/19

6SE6400-0AP00-0AA1
6SE6400-0BE00-0AA0
6SE6400-0BP00-0AA0

2/14
2/14

3/12
-

4/19
4/19

6SE6400-0DN00-0AA0
6SE6400-0DR00-0AA0
6SE6400-0EN00-0AA0

1/9
-

2/14
-

3/12
-

4/19
4/19

6SE6400-0GP00-0.A0
6SE6400-0MD00-0AA0

2/13
2/14

3/10
-

4/16, 4/17
4/19

6SE6400-0P.00-0AA0
6SE6400-0SP00-0AA0

1/9
1/9

2/14
-

3/12
-

4/19
-

6SE6400-1P.00-0AA0

2/14

3/12

4/19

6SE6400-2FA0.
6SE6400-2FB0.
6SE6400-2FL0.
6SE6400-2FS0.

1/9
-

2/11
2/11
2/12
2/11

3/11

4/14
4/14
4/14
4/17

6SE6400-3CC..
6SE6400-3TC..

1/9
-

2/12
2/12

3/10, 3/11
3/10, 3/11

4/15, 4/17
4/15, 4/17

6SE6400-4B...

4/15, 4/17

6SE6400-5....

1/9

2/15

3/13

4/20

6SE6410-2BB..
6SE6410-2UA..
6SE6410-2UB..

1/7
1/7
1/7

6SE6420-2AB..
6SE6420-2AC..
6SE6420-2AD..
6SE6420-2UC..
6SE6420-2UD..

2/8
2/8
2/8
2/8
2/8

6SE6430-2AD..
6SE6430-2UD..

3/8
3/8

6SE6440-2AB..
6SE6440-2AC..
6SE6440-2AD..
6SE6440-2UC..
6SE6440-2UD..
6SE6440-2UE..

4/11
4/11
4/11
4/9
4/9
4/10

6SL3000-0BE3.
6SL3000-0CE3.

4/14
4/15

3NA3...
3NE1...
3RV10..
3VL....

A/16

Siemens DA 51.2 October 2002

The last digit of the complete


Order No. for the inverters
represents the release version.
When ordering, a digit from
that specified may be present
as a result of further technical
development.

MICROMASTER 410/420/430/440
Appendix

Conditions of Sale and Delivery


In Germany
Subject to the General Conditions of Sale as well as the
General Conditions of Supply
and Delivery for Products and
Services of the Electrical and
Electronics Industry.
For Export
Subject to the General Conditions of Supply and Delivery
for Products and Services of
the Electrical and Electronics
Industry and to any other conditions agreed upon with the
recipients of catalogs/price
lists.

Export regulations

Software products are subject


to the General Licence Conditions for Software Products
for Automation and Drives.
Prices are listed in (Euro)
ex delivery point, excluding
packaging.
Turnover tax (VAT) is not
included in the prices. It will be
added according to legal
provisions at the applicable
rate.
We reserve the right to adjust
prices and shall charge the
prices applying on the date of
delivery.
All dimensions in this catalog/
price list are in mm. The
illustrations are for reference
only.
We reserve the right to make
changes, in particular to the
specified values, dimensions
and weights, unless specified
otherwise on the individual
pages of this catalog/price list.

The products listed in this catalog/price list may be subject


to European/German and/or
US export provisions.
Any export requiring approval
is therefore subject to authorization by the relevant authorities.
AL

For the products listed in this


catalog/price list, the following
export regulations must be
adhered to in accordance with
currently valid regulations.

Number of the German export list


Products with a code other than N must be approved
for export.
The export codes of the respective data medium must
also be adhered to for software products.
Goods labeled with AL not equal to N are subject to
European or German export authorization when being
exported out of the EU.

ECCN Number of US export list


(Export Control Classification Number)
Products with a code other than N require approval for
re-export to certain countries.
The export codes of the respective data medium must
also be adhered to for software products.
Goods labeled with ECCN not equal to N are subject to
US reexport authorization.
Even without a label, or with
label AL: N or ECCN: N,
authorization may be required
due to the final whereabouts
and purpose for which the
goods are to be used.

The AL and ECCN export


codes specified in our confirmations, delivery notes and
invoices apply.
Subject to change without
prior notice.

Siemens DA 51.2 October 2002

A/17

MICROMASTER 410/420/430/440
Appendix

A
Responsible for
Technical contents:
Siemens AG, A&D SD SM, Erlangen
General editing:
Siemens AG, A&D PT 5, Erlangen

Siemens AG
Automation & Drives
Standard Drives
Postfach 32 69
D-91050 Erlangen
Germany
A/18

Siemens DA 51.2 October 2002

Siemens Aktiengesellschaft
Automation and Drives
Standard Drives
Postfach 32 69, D-91050 Erlangen

www.siemens.com/micromaster

You might also like