Flyer RCS 9698G H Gateway
Flyer RCS 9698G H Gateway
Flyer RCS 9698G H Gateway
RCS-9698G/H
Gateway
The RCS-9698G/H gateway is used to establish a binary signals, transformer tap position, pulse counting
communication links between a substation and the Load of electricity quantity, communicationstates and so on. In
Dispatching Centers, or Grid Control Centers, in order to addition, all the collected information can be sent to the
achieve data exchange. It is capable of communicating with dispatching center.
several dispatching centers simultaneously via different
telecommunication channels according to the applied Small-capacity memory storage
protocol. Industrial hardware with embedded components is With the incorporation of small-capacity industrial-grade
adopted instead of PC technology with weak rotary machinery NANDFLASH memory (128MBytes for single machine or
(Hard disk, Cooling Fan, etc.). RCS-9698G/H supports both 256MBytes for a dual machine system), a user can improve
conventional communication channels and modern powerful the collection of event information, such as: protection relays
Ethernet, and is fully complient with the IEC-61850 international selfchecking information, trip event records, fault information,
standard communication protocol. RCS-9698G can be used settings modification records and so on. This techonology
independently, while RCS-9698H adopts duplicated scheme also improves remote command from dispatching center,
with two RCS-9698G units to realize HOT-STANDBY or Dual- including selecting and executing of the binary outputs and
HOT running mode. setting modifications, remote regulation of transformer tap
position, remote signaling reset events and so on. These
Basic Communication Protocol events are stored, then automatically collected from various
Upward communications: IEC 60870-5-101, IEC 60870- BCUs, protection relays and some other auxiliary IEDs.
5-104, MODBUS, CDT, DNP3.0, SCI1801, RP570 and
further protocols upon request Settings management
RCS-9698G/H can upload/download and modify settings
Downward communications:IEC 60870-5-103 or IEC61850
of various protection relays and auxiliary IEDs. Setting
It can cooperate with RCS-9794A/B to realize various management can be done by the Debugging Tool or
protocols. accomplished by the dispatching center up.
Automation System
of events the operator should set the time periodically or it
should be synchronized by a master clock. The equipment
LCD display with 25 LED indicators and dedicated keypad
can be configured to synchronize itselfwith the IEDs clock.
Data marshalling and distribution
Diagnostic
The equipment can continuously self-supervise on its Continuous self-monitoring
firmware. Once a hardware/software fault happens; its
Continuous supervision on connected device
watchdog will make the CPU card restart.
Powerful and friendly configuration tool and debugging tool