ATS (Automatic Trasfer Switch) : 2 Positions (A B)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

ATS (Automatic Trasfer Switch) : 2 Positions (AB)

- Suitable for small inductive load current.


- UL1008 Certificate
- Continuous energize type/Instantaneous energize type
- Quick transfer to dual direction

Type 61W 62W 64W


100 200 400
Rated Current (In) A
150 300 600
Rated voltage (Ue) V AC600 AC600 AC600, DC125
Poles P 3, 4 3, 4 2, 3, 4
Throw T One Throw One Throw Double Throw
Connection Front

Method Back - -

Short Circuit Withstand


With Circuit Limiting Fuses kA 200 200 200
With any Circuit Breaker kA 10 10 10
With Specific Circuit Breaker kA 22 22 42
Switch Capacity Class AC33B AC33B AC33B
Electrical Times 50,000 50,000 50,000
Operational Cycle
Mechanical Times 250,000 250,000 250,000
Transfer Sequence AB AB AB
opening msec 30 30 60
Operation Time closing msec 60 60 200
closing off sec - - -
Operating Voltage & Current 3P 4P 3P 4P 2P 3P 4P
DC110V A - - - - 7.5 7.5 11
AB
AC100/110V A - - - - 7.5 7.5 11
closing
AC200/220V A 10 10 10 10 3.8 3.8 5.5
External Size & Weight

H 171 171 171 171 254 254 254

Front Size(mm) W 219 219 219 219 248 299 350

D 110 110 110 110 119 119 119

H - - - - 208 208 208

Back Size(mm) W - - - - 236 287 338

D - - - - 163 163 163


Front kg 2.5 3 3.5 4 7.5 8 10.5
Weight
Back kg - - - - 6 8 10
Other Detailed Info
Circuit diagram A6-21 A6-21
Contact Time chart A6-18 A6-18
Drawing A6-31 A6-31
Precautions A6-16 A6-16
ATS (Automatic Trasfer Switch) : 3 Positions (ANB)

- Maximum breaking capacity (IEC60947-6)


- High transfer performance for inductive load current
- UL1008 Certificate

Type 61WN 62WN 64WN 66WN 68WN 610WN 612WN 616WN 620WN 625WN 630WN

AC33B 100 200 400 600 800 1000 1200 1600 2000 2500 3000
Rated Current (In) A
AC31B 150 300 600 800 1000 1200 1400 1800 2500 3000 3500
Rated voltage (Ue) V AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125
Poles P 2, 3, 4 2, 3, 4 2, 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4
Throw T Double Throw Double Throw Double Throw Double Throw Double Throw Double Throw Double Throw Double Throw Double Throw Double Throw Double Throw

Connection Front - - -

Method Back

Short Circuit Withstand


With Circuit Limiting Fuses kA 200 200 200 200 200 200 200 200 200 200 100
With any Circuit Breaker kA 10 10 35 35 50 50 50 85 85 100 250
With Specific Circuit Breaker kA 25 25 45 65 65 65 65 85 100 100 100
Switch Capacity Class AC33B AC33B AC33B AC33B AC33B AC33B AC33B AC33B AC33B AC33B AC33B
Electrical Times 50,000 50,000 50,000 50,000 10,000 10,000 10,000 10,000 5,000 5,000 5,000
Operational Cycle
Mechanical Times 250,000 250,000 250,000 250,000 50,000 50,000 50,000 50,000 10,000 10,000 10,000
Transfer Sequence AB, ANeutral(off)B AB, ANeutral(off)B
closing msec 55 55 55 60 100 100 115 115 140 180 180
A power
Operatio trip msec 20 20 20 20 30 30 30 30 35 35 35
n
Time closing msec 80 80 80 90 135 135 145 145 190 220 220
B power
trip msec 20 20 20 25 30 30 30 30 35 35 35
Operating Voltage & Current 2P 3P 4P 2P 3P 4P 2P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P
DC110V A 4 4 5 4 4 5 5 5 7.2 6.4 9 8 10 8 10 8 10 8 10 13 16 13 16 16 18
closing AC100/110V A 4 4 5 4 4 5 5 5 7.2 6.4 9 8 10 8 10 8 10 8 10 13 16 13 16 16 18
AC200/220V A 2 2 2.5 2 2 2.5 2.5 2.5 3.6 3.2 4.5 4 5 4 5 4 5 4 5 6.5 8 6.5 8 8 9
AC/DC110V A 1.4 1.4 1.4 3 3 4 4 4 4 4 4
Trip
AC220V A 0.7 0.7 0.7 1.5 1.5 2 2 2 2 2 2
External Size & Weight
H 192 192 192 192 192 192 254 254 254 278 278 298 298 298 298 535 535 535 535 - - - - - -
Front Size(mm) W 218 254 290 218 254 290 248 299 350 340 400 400 480 400 480 453 536 453 536 - - - - - -
D 118 118 118 118 118 118 119 119 119 143 143 143 143 143 143 228 228 228 228 - - - - - -
H 174 174 174 174 174 174 208 208 208 248 248 267 267 267 267 380 380 380 380 380 380 380 380 380 380
Back Size(mm) W 218 254 290 218 254 290 248 299 350 340 400 400 480 400 480 453 536 453 536 528 636 603 736 603 736
D 144 144 144 144 144 144 164 164 164 176 176 178 178 178 178 261 261 261 261 261 261 261 261 261 261
Front kg 4.5 6 8 4.5 6 8 7.5 9 10.5 15 18 20 24 21 25 52.5 63.5 58 69 - - - - - -
Weight
Back kg 4.5 6 8 4.5 6 8 6 8 10 14 17 19 23 20 24 50 60 55 65 65 85 92.5 119 92.5 119
Other Detailed Info
Circuit diagram A6-19 A6-19 A6-19 A6-19 A6-19 A6-19 A6-19 A6-19 A6-19 A6-19 A6-19
Contact Time chart A6-18 A6-18 A6-18 A6-18 A6-18 A6-18 A6-18 A6-18 A6-18 A6-18 A6-18
Drawing A6-24 A6-24 A6-25 A6-26 A6-26 A6-26 A6-27 A6-27 A6-27 A6-28 A6-28
Precautions A6-14 A6-14 A6-14 A6-14 A6-14 A6-14 A6-14 A6-14 A6-14 A6-14 A6-14
Miniature ATS(Automatic Transfer Switch) : 2 Position Type

- Saving power :
It is in an instantaneous excitation mode with little operating current
(1.6A in case of AC 220V operation)
- Safe Design :
The breaking part is molded for a dust-proof so the operational cycle
of the contact part is semi-permanent.
- 2-Coil Mode :
It adopted a simple operation mode using 2 coils
- Miniature :
It can be built inside the portable generator or UPS
- Low Cost :
It is a miniature type and it is optimal for a single phase with less than 200A (non-inductive)
- Applied Standard :
IEC 60947-6-1 / UL1008

Type 21HS 22HS

Rated Current A 100 100


Rated Voltage V AC250

Poles P 2

Connection Method Front

Performance

Short Time Current (1sec) Ka 10

Short Circuit Peak Current kA 25

Switch Capacity Closing 10 Ie, Breaking 8 Ie, Cos = 0.35

Operational Electrical Times 50, 000


Cycle Mechanical Times 250, 000

Switch Frequency Times / hr 150 (No.4)

Transfer Sequence AB

Operating opening msec 30


Time closing msec 60
Operating Voltage & Current AC220V, 1.6A AC220V, 4.85A
External Size & Weight

H 165 176

W 127 151

D 100 121

Weight kg 1.1 2.2

1) Transfer time is operated at 0.3sec or less. Make


sure a full operation is possible with an operation
command of 0.5sec or more.

Precautions 2) When A-side and B-side operation command is


done simultaneously, it may lead to coil burning.

3) In case of an operation relay, select a sufficient


contact capacity that exceeds the operating current.
Uninterruptible ATS(Automatic Trasfer Switch) : 3 Position (ASynchronizingB)

- Maximum breaking capacity (IEC60947-6)


- Mutual interlocking (Utility and Gen set)
- Synchronous transfer performance

Type 61CT 62CT 64CT 66CT 610CT 616CT 620CT 630CT


Rated Current (In) A 100 200 400 600 800, 1000 1200, 1600 2000 3000
Rated voltage (Ue) V AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125 AC600, DC125
Poles P 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4
Throw T Double Throw Double Throw Double Throw Double Throw Double Throw Double Throw Double Throw
Connection Front - -

Method Back

Performance
Short Time Current(1sec) kA 5 10 12 15 22 25 35 50
Short Circuit Peak Current kA 12.5 25 30 37.5 50 55 60 80
Switch Capacity Class AC33B AC33B AC33B AC33B AC33B AC33B AC33B AC33B
Electrical Times 50,000 50,000 50,000 10,000 10,000 10,000 5,000 5,000
Operational Cycle
Mechanical Times 250,000 250,000 250,000 50,000 50,000 50,000 10,000 10,000
Transfer Sequence A B, A Neutral (off) B, A Overlapping (overlapping) B
Conditions of uninterruptible transfer Phase difference : Within electrical angle 10, Frequency difference : Within 0.2Hz , Voltage : Voltage difference with the commercial one is within 5% , Instantaneous Interconnection Time : Within 0.05 second
closing msec 55 55 60 100 115 115 180 140
Apower
Opera- trip msec 20 20 25 30 30 30 30 35
tion Time closing msec 80 80 90 135 145 150 220 190
Bpower
trip msec 20 20 25 30 30 30 30 35
Operating Voltage & Current 2P 3P 4P 2P 3P 4P 2P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P
DC110V A 4 4 5 5 5 7 6.4 6.4 9 7 8 8 10 10 13 13 16 16 18
Closing AC100/110V A 4 4 5 5 5 7 6.4 6.4 9 7 8 8 10 10 13 13 16 16 18
AC200/220V A 2 2 2.5 2.5 2.5 3.6 3.2 3.2 4.5 3.5 4 4 5 5 6.5 6.5 8 8 9
AC/DC110V A 1.4 1.4 2 2 2 2 4 4
Trip
AC220V A 0.7 0.7 1 1 1 1 2 2
External Size & Weight

H 268 268 268 283 283 283 307 307 307 545 545 609 609 645 645 - - - -

Front Size(mm) W 211 241 271 241 286 331 293 353 413 465 530 510 590 570 670 - - - -

D 112 112 112 112 112 132 132 132 220 220 220 220 220 220 - - - -

H - - - - - - - - - - - - - - - 600 600 600 600

Back Size(mm) W - - - - - - - - - - - - - - - 683 818 833 1018

D - - - - - - - - - - - - - - - 329 329 364 364

Front kg 6.5 8 10 8 10 12 14 17 21 53 61 66 76 72 84
Weight
Back kg 6.5 8 10 8 10 12 14 17 21 43 52 5043 61 57 69 130 150 165 205
Other Detailed Info
Circuit diagram A6-23 A6-23 A6-23 A6-23
Drawing A6-36 A6-36 A6-37 A6-37 A6-38
Precautions A6-20 A6-20 A6-20 A6-20