Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SDS - Penguard - Comp. B - Marine - Protective - English (Uk) - United Kingdom - 612 - 01.11.2012

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Conforms to Regulation (EC) No.

1907/2006 (REACH), Annex II - United Kingdom (UK)

SAFETY DATA SHEET

Penguard - Comp. B
SECTION 1: Identification of the substance/mixture and of the
company/undertaking
1.1 Product identifier
Product name : Penguard - Comp. B
Product code : 612
Product description : Coatings: HardenerSolvent-borne.
Product type : Liquid.
Other means of : Not available.
identification

1.2 Relevant identified uses of the substance or mixture and uses advised against
Identified uses
Uses in Coatings - Industrial use
Uses in Coatings - Professional use
See Annex to the Safety data sheet for additional information in the Exposure Scenario(s).

1.3 Details of the supplier of the safety data sheet


Jotun Paints (Europe) Ltd.
Stather Road
Flixborough, Scunthorpe
North Lincolnshire
DN15 8RR
England

Tel: +44 17 24 40 00 00
Fax: +44 17 24 40 01 00
SDSJotun@jotun.com

1.4 Emergency telephone number


Contact National Poison Centre via Hospital or Registered Medical Practitioner

SECTION 2: Hazards identification


2.1 Classification of the substance or mixture
Product definition : Mixture
Classification according to Directive 1999/45/EC [DPD]
The product is classified as dangerous according to Directive 1999/45/EC and its amendments.
Classification : R10
Xn; R20/21
Xi; R41, R38
Physical/chemical hazards : Flammable.
Human health hazards : Harmful by inhalation and in contact with skin. Risk of serious damage to eyes.
Irritating to skin.
See Section 16 for the full text of the R phrases or H statements declared above.
See Section 11 for more detailed information on health effects and symptoms.

2.2 Label elements


Hazard symbol or symbols :

Indication of danger : Harmful

Date of issue : 01.11.2012. 1/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 2: Hazards identification


Risk phrases : R10- Flammable.
R20/21- Harmful by inhalation and in contact with skin.
R41- Risk of serious damage to eyes.
R38- Irritating to skin.
Safety phrases : S23- Do not breathe vapour / spray.
S26- In case of contact with eyes, rinse immediately with plenty of water and seek
medical advice.
S36/37/39- Wear suitable protective clothing, gloves and eye/face protection.
S51- Use only in well-ventilated areas.
Hazardous ingredients : xylene
Supplemental label : Contains 3,6-diazaoctanethylenediamin. May produce an allergic reaction.
elements

2.3 Other hazards


Other hazards which do not : Not available.
result in classification

SECTION 3: Composition/information on ingredients


Substance/mixture : Mixture
Classification
Product/ingredient Identifiers % 67/548/EEC Regulation (EC) No. Type Notes
name 1272/2008 [CLP]
Fatty acids, C18- CAS: 68410-23-1 50-75 Xi; R41 Eye Dam. 1, H318 [1] -
unsatd., dimers,
reaction products with
polyethylenepolyamines
xylene REACH #: 01- 20-25 R10 Flam. Liq. 3, H226 [1] [2] C
2119488216-32
EC: 215-535-7 Xn; R20/21 Acute Tox. 4, H312
CAS: 1330-20-7 Xi; R38 Acute Tox. 4, H332
Index: 601-022-00-9 Skin Irrit. 2, H315
ethylbenzene REACH #: 01- 3-7 F; R11 Flam. Liq. 2, H225 [1] [2] -
2119489370-35
EC: 202-849-4 Xn; R20 Acute Tox. 4, H332
CAS: 100-41-4
Index: 601-023-00-4
3,6- REACH #: 01- 0,25-1 Xn; R21/22 Acute Tox. 3, H311 [1] -
diazaoctanethylenediamin 2119487919-13
EC: 203-950-6 C; R34 Skin Corr. 1B, H314
CAS: 112-24-3 R43 Eye Dam. 1, H318
Index: 612-059-00-5 R52/53 Skin Sens. 1, H317
Aquatic Chronic 3,
H412
See Section 16 for See Section 16 for
the full text of the R- the full text of the H
phrases declared statements declared
above. above.

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations
applicable, are classified as hazardous to health or the environment, are PBTs or vPvBs or have been assigned a
workplace exposure limit and hence require reporting in this section.
Type
[1] Substance classified with a health or environmental hazard
[2] Substance with a workplace exposure limit
[3] Substance meets the criteria for PBT according to Regulation (EC) No. 1907/2006, Annex XIII
[4] Substance meets the criteria for vPvB according to Regulation (EC) No. 1907/2006, Annex XIII
Occupational exposure limits, if available, are listed in Section 8.

Date of issue : 01.11.2012. 2/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 4: First aid measures


4.1 Description of first aid measures
General : In all cases of doubt, or when symptoms persist, seek medical attention. Never give
anything by mouth to an unconscious person. If unconscious, place in recovery
position and seek medical advice.
Inhalation : Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is
irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by
trained personnel.
Skin contact : Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water
or use recognised skin cleanser. Do NOT use solvents or thinners.
Eye contact : Check for and remove any contact lenses. Immediately flush eyes with running water
for at least 15 minutes, keeping eyelids open. Seek immediate medical attention.
Ingestion : If swallowed, seek medical advice immediately and show the container or label. Keep
person warm and at rest. Do not induce vomiting.
Protection of first-aiders : No action shall be taken involving any personal risk or without suitable training. It may
be dangerous to the person providing aid to give mouth-to-mouth resuscitation.

4.2 Most important symptoms and effects, both acute and delayed
Potential acute health effects
Eye contact : Severely irritating to eyes. Risk of serious damage to eyes.
Inhalation : Harmful by inhalation.
Skin contact : Harmful in contact with skin. Irritating to skin.
Ingestion : Irritating to mouth, throat and stomach.
Over-exposure signs/symptoms
Eye contact : Adverse symptoms may include the following:
pain or irritation
watering
redness
Inhalation : No specific data.
Skin contact : Adverse symptoms may include the following:
irritation
redness
Ingestion : No specific data.

4.3 Indication of any immediate medical attention and special treatment needed
Notes to physician : Treat symptomatically. Contact poison treatment specialist immediately if large
quantities have been ingested or inhaled.
Specific treatments : No specific treatment.

SECTION 5: Firefighting measures


5.1 Extinguishing media
Suitable extinguishing : Recommended: alcohol-resistant foam, CO 2, powders, water spray.
media

Unsuitable extinguishing : Do not use water jet.


media

5.2 Special hazards arising from the substance or mixture


Hazards from the : Flammable liquid. In a fire or if heated, a pressure increase will occur and the
substance or mixture container may burst, with the risk of a subsequent explosion. Runoff to sewer may
create fire or explosion hazard.
Hazardous thermal : Decomposition products may include the following materials:
decomposition products carbon dioxide
carbon monoxide

5.3 Advice for firefighters

Date of issue : 01.11.2012. 3/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 5: Firefighting measures


Special protective actions : Promptly isolate the scene by removing all persons from the vicinity of the incident if
for fire-fighters there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.

Special protective : Fire-fighters should wear appropriate protective equipment and self-contained
equipment for fire-fighters breathing apparatus (SCBA) with a full face-piece operated in positive pressure
mode. Clothing for fire-fighters (including helmets, protective boots and gloves)
conforming to European standard EN 469 will provide a basic level of protection for
chemical incidents.

SECTION 6: Accidental release measures


6.1 Personal precautions, protective equipment and emergency procedures
For non-emergency : No action shall be taken involving any personal risk or without suitable training.
personnel Evacuate surrounding areas. Keep unnecessary and unprotected personnel from
entering. Do not touch or walk through spilt material. Shut off all ignition sources. No
flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide
adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put
on appropriate personal protective equipment.
For emergency responders : If specialised clothing is required to deal with the spillage, take note of any information
in Section 8 on suitable and unsuitable materials. See also Section 8 for additional
information on hygiene measures.

6.2 Environmental : Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains
precautions and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air).

6.3 Methods and materials for containment and cleaning up


Small spill : Stop leak if without risk. Move containers from spill area. Dilute with water and mop
up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry
material and place in an appropriate waste disposal container. Use spark-proof tools
and explosion-proof equipment. Dispose of via a licensed waste disposal contractor.
Large spill : Stop leak if without risk. Move containers from spill area. Approach the release from
upwind. Prevent entry into sewers, water courses, basements or confined areas.
Wash spillages into an effluent treatment plant or proceed as follows. Contain and
collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite
or diatomaceous earth and place in container for disposal according to local
regulations. Use spark-proof tools and explosion-proof equipment. Dispose of via a
licensed waste disposal contractor. Contaminated absorbent material may pose the
same hazard as the spilt product.

6.4 Reference to other : See Section 1 for emergency contact information.


sections See Section 8 for information on appropriate personal protective equipment.
See Section 13 for additional waste treatment information.

SECTION 7: Handling and storage


The information in this section contains generic advice and guidance. The list of Identified Uses in Section 1 should be
consulted for any available use-specific information provided in the Exposure Scenario(s).
7.1 Precautions for safe handling
Prevent the creation of flammable or explosive concentrations of vapours in air and avoid vapour concentrations higher
than the occupational exposure limits.
In addition, the product should only be used in areas from which all naked lights and other sources of ignition have been
excluded. Electrical equipment should be protected to the appropriate standard.
To dissipate static electricity during transfer, earth drum and connect to receiving container with bonding strap. Operators
should wear antistatic footwear and clothing and floors should be of the conducting type.
Keep away from heat, sparks and flame. No sparking tools should be used.
Avoid contact with skin and eyes. Avoid the inhalation of dust, particulates, spray or mist arising from the application of
this preparation. Avoid inhalation of dust from sanding.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed.

Date of issue : 01.11.2012. 4/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 7: Handling and storage


Put on appropriate personal protective equipment (see Section 8).
Never use pressure to empty. Container is not a pressure vessel.
Always keep in containers made from the same material as the original one.
Comply with the health and safety at work laws.
Information on fire and explosion protection
Vapours are heavier than air and may spread along floors. Vapours may form explosive mixtures with air.

When operators, whether spraying or not, have to work inside the spray booth, ventilation is unlikely to be sufficient to
control particulates and solvent vapour in all cases. In such circumstances they should wear a compressed air-fed
respirator during the spraying process and until such time as the particulates and solvent vapour concentration has fallen
below the exposure limits.
7.2 Conditions for safe storage, including any incompatibilities
Store in accordance with local regulations.
Notes on joint storage
Keep away from: oxidising agents, strong alkalis, strong acids.
Additional information on storage conditions
Observe label precautions. Store in a dry, cool and well-ventilated area. Keep away from heat and direct sunlight. Keep
away from sources of ignition. No smoking. Prevent unauthorised access. Containers that have been opened must be
carefully resealed and kept upright to prevent leakage.

7.3 Specific end use(s)


Recommendations : Not available.
Industrial sector specific : Not available.
solutions

SECTION 8: Exposure controls/personal protection


The information in this section contains generic advice and guidance. The list of Identified Uses in Section 1 should be
consulted for any available use-specific information provided in the Exposure Scenario(s).
8.1 Control parameters
Occupational exposure limits

Product/ingredient name Exposure limit values


xylene EH40/2005 WELs (United Kingdom (UK), 8/2007). Absorbed
through skin.
STEL: 441 mg/m 15 minute(s).
STEL: 100 ppm 15 minute(s).
TWA: 220 mg/m 8 hour(s).
TWA: 50 ppm 8 hour(s).
ethylbenzene EH40/2005 WELs (United Kingdom (UK), 8/2007). Absorbed
through skin.
STEL: 552 mg/m 15 minute(s).
STEL: 125 ppm 15 minute(s).
TWA: 100 ppm 8 hour(s).
TWA: 441 mg/m 8 hour(s).
Recommended monitoring : If this product contains ingredients with exposure limits, personal, workplace
procedures atmosphere or biological monitoring may be required to determine the effectiveness
of the ventilation or other control measures and/or the necessity to use respiratory
protective equipment. Reference should be made to European Standard EN 689 for
methods for the assessment of exposure by inhalation to chemical agents and
national guidance documents for methods for the determination of hazardous
substances.
Derived effect levels
No DELs available.

Predicted effect concentrations


No PECs available.

8.2 Exposure controls

Date of issue : 01.11.2012. 5/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 8: Exposure controls/personal protection


Appropriate engineering : Use only with adequate ventilation. Use process enclosures, local exhaust ventilation
controls or other engineering controls to keep worker exposure to airborne contaminants
below any recommended or statutory limits. The engineering controls also need to
keep gas, vapour or dust concentrations below any lower explosive limits. Use
explosion-proof ventilation equipment.
Individual protection measures
Hygiene measures : Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period.
Appropriate techniques should be used to remove potentially contaminated clothing.
Wash contaminated clothing before reusing. Ensure that eyewash stations and
safety showers are close to the workstation location.
Eye/face protection : Safety eyewear complying with an approved standard should be used when a risk
assessment indicates this is necessary to avoid exposure to liquid splashes, mists or
dusts.
Skin protection
Hand protection : For prolonged or repeated handling, use the following type of gloves: gloves:
polyvinyl alcohol or nitrile.

Barrier creams may help to protect the exposed areas of the skin but should not be
applied once exposure has occurred.
For prolonged or repeated handling, use the following type of gloves:

Recommended, gloves(breakthrough time) > 8 hours: nitrile rubber, 4H, Teflon


Not recommended, gloves(breakthrough time) < 1 hour: neoprene, butyl rubber,
PVC
For right choice of glove materials, with focus on chemical resistance and time of
penetration, seek advice by the supplier of chemical resistant gloves.
The user must check that the final choice of type of glove selected for handling this
product is the most appropriate and takes into account the particular conditions of
use, as included in the user's risk assessment.
Body protection : Personal protective equipment for the body should be selected based on the task
being performed and the risks involved and should be approved by a specialist
before handling this product.
Other skin protection : Appropriate footwear and any additional skin protection measures should be selected
based on the task being performed and the risks involved and should be approved by
a specialist before handling this product.
Respiratory protection : If workers are exposed to concentrations above the exposure limit, they must use
appropriate, certified respirators. Use respiratory mask with charcoal and dust filter
when spraying this product.(as filter combination A2-P2). In confined spaces, use
compressed-air or fresh-air respiratory equipment. When use of roller or brush,
consider use of charcoalfilter.
Also use filter K by spraying.
Environmental exposure : Emissions from ventilation or work process equipment should be checked to ensure
controls they comply with the requirements of environmental protection legislation. In some
cases, fume scrubbers, filters or engineering modifications to the process equipment
will be necessary to reduce emissions to acceptable levels.

SECTION 9: Physical and chemical properties


9.1 Information on basic physical and chemical properties
Appearance
Physical state : Liquid.
Colour : Various colours.
Odour : Characteristic.
Odour threshold : Not available.
pH : Not available.
Melting point/freezing point : Not available.
Initial boiling point and boiling : Not available.
range

Date of issue : 01.11.2012. 6/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 9: Physical and chemical properties


Flash point : Closed cup: 25C
Evaporation rate : Not available.
Flammability (solid, gas) : Not available.
Burning time : Not applicable.
Burning rate : Not applicable.
Upper/lower flammability or : 1.1 - 7%
explosive limits
Vapour pressure : Not available.
Vapour density : Not available.
Relative density : 0.95 g/cm 3
Solubility(ies) : Insoluble in the following materials: cold water and hot water.
Partition coefficient: n- : Not available.
octanol/water
Auto-ignition temperature : Not available.
Decomposition temperature : Not available.
Viscosity : Not available.
Explosive properties : Not available.
Oxidising properties : Not available.

9.2 Other information


No additional information.

SECTION 10: Stability and reactivity


10.1 Reactivity : No specific test data related to reactivity available for this product or its ingredients.
10.2 Chemical stability : The product is stable.
10.3 Possibility of hazardous : Under normal conditions of storage and use, hazardous reactions will not occur.
reactions
10.4 Conditions to avoid : Avoid all possible sources of ignition (spark or flame). Do not pressurise, cut, weld,
braze, solder, drill, grind or expose containers to heat or sources of ignition.
10.5 Incompatible materials : Reactive or incompatible with the following materials:
oxidizing materials
10.6 Hazardous : Under normal conditions of storage and use, hazardous decomposition products
decomposition products should not be produced.

SECTION 11: Toxicological information


11.1 Information on toxicological effects
There are no data available on the preparation itself. The preparation has been assessed following the conventional
method of the Dangerous Preparations Directive 1999/45/EC and classified for toxicological hazards accordingly. See
sections 2 and 15 for details.

Exposure to component solvent vapour concentrations in excess of the stated occupational exposure limit may result in
adverse health effects such as mucous membrane and respiratory system irritation and adverse effects on the kidneys,
liver and central nervous system. Solvents may cause some of the above effects by absorption through the skin.
Symptoms and signs include headache, dizziness, fatigue, muscular weakness, drowsiness and, in extreme cases, loss
of consciousness. Repeated or prolonged contact with the preparation may cause removal of natural fat from the skin,
resulting in non-allergic contact dermatitis and absorption through the skin. If splashed in the eyes, the liquid may cause
irritation and reversible damage. Swallowing may cause nausea, diarrhoea, vomiting, gastro-intestinal irritation and
chemical pneumonia.

Contains 3,6-diazaoctanethylenediamin. May produce an allergic reaction.


Risk of serious damage to eyes.
Product/ingredient name Result Species Dose Exposure

Date of issue : 01.11.2012. 7/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 11: Toxicological information


xylene LC50 Inhalation Gas. Rat 5000 ppm 4 hours
ethylbenzene LD50 Oral Rat 3500 mg/kg -
3,6- LD50 Dermal Rabbit 805 mg/kg -
diazaoctanethylenediamin
LD50 Dermal Rabbit 805 mg/kg -
LD50 Oral Mouse 1600 mg/kg -
LD50 Oral Rat 2500 mg/kg -

SECTION 12: Ecological information


12.1 Toxicity
Product/ingredient name Result Species Exposure
ethylbenzene Acute EC50 7,2 mg/L Algae 48 hours
Acute EC50 2,93 mg/L Daphnia 48 hours
Acute LC50 4,2 mg/L Fish 96 hours
3,6- Acute LC50 33900 ug/L Fresh water Daphnia - Daphnia magna 48 hours
diazaoctanethylenediamin
Conclusion/Summary : No known significant effects or critical hazards.

12.2 Persistence and degradability


Conclusion/Summary : Not available.
Product/ingredient name Aquatic half-life Photolysis Biodegradability
xylene - - Readily
ethylbenzene - - Readily
3,6- - - Not readily
diazaoctanethylenediamin

12.3 Bioaccumulative potential


Product/ingredient name LogPow BCF Potential
xylene 3,12 - high
3,6- -1.66 to -1.4 - low
diazaoctanethylenediamin

12.4 Mobility in soil


Soil/water partition : Not available.
coefficient (K OC)
Mobility : Not available.

12.5 Results of PBT and vPvB assessment


PBT : Not applicable.
vPvB : Not applicable.

12.6 Other adverse effects : No known significant effects or critical hazards.

SECTION 13: Disposal considerations


The information in this section contains generic advice and guidance. The list of Identified Uses in Section 1 should be
consulted for any available use-specific information provided in the Exposure Scenario(s).
13.1 Waste treatment methods
Do not allow to enter drains or watercourses. Material and/or container must be disposed of as hazardous waste.
European waste catalogue : 08 01 11* Waste paint and varnish containing organic solvents or other dangerous
(EWC) substances. If this product is mixed with other wastes, this code may no longer apply. If
mixed with other wastes, the appropriate code should be assigned. For further
information, contact your local waste authority.

Date of issue : 01.11.2012. 8/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 13: Disposal considerations

SECTION 14: Transport information


Transport within users premises: always transport in closed containers that are upright and secure. Ensure that
persons transporting the product know what to do in the event of an accident or spillage.
Transport in accordance with ADR/RID, IMDG/IMO and ICAO/IATA and national regulation.
International transport regulations
14.1 UN number : 1263
14.2 UN proper shipping : Paint.
name
14.3 Transport hazard : 3
class(es)

14.4 Packing group : III


14.5 Environmental hazards : No.
14.6 Special precautions : Not available.
for user
Additional information
ADR / RID : Tunnel restriction code: (D/E)
Hazard identification number: 30
Special provisions: 640E
ADR/RID: Viscous substance. Not restricted, ref. chapter 2.2.3.1.5 (applicable to
receptacles < 450 litre capacity).
IMDG : Emergency schedules (EmS)
F-E, S-E
14.7 Transport in bulk : Not available.
according to Annex II of
MARPOL 73/78 and the IBC
Code

SECTION 15: Regulatory information


15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
EU Regulation (EC) No. 1907/2006 (REACH)
Annex XIV - List of substances subject to authorisation
Substances of very high concern
None of the components are listed.
Annex XVII - Restrictions : Not applicable.
on the manufacture,
placing on the market and
use of certain dangerous
substances, mixtures and
articles
Other EU regulations
Europe inventory : Not determined.
Black List Chemicals : Not listed
Priority List Chemicals : Listed
Integrated pollution : Not listed
prevention and control list
(IPPC) - Air
Integrated pollution : Not listed
prevention and control list
(IPPC) - Water
International regulations
Date of issue : 01.11.2012. 9/13
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 15: Regulatory information


Chemical Weapons : Not listed
Convention List Schedule I
Chemicals

Chemical Weapons : Not listed


Convention List Schedule II
Chemicals
Chemical Weapons : Not listed
Convention List Schedule III
Chemicals

15.2 Chemical Safety : This product contains substances for which Chemical Safety Assessments are still
Assessment required.

SECTION 16: Other information


Indicates information that has changed from previously issued version.
Abbreviations and acronyms : ATE = Acute Toxicity Estimate
CLP = Classification, Labelling and Packaging Regulation [Regulation (EC) No.
1272/2008]
DNEL = Derived No Effect Level
EUH statement = CLP-specific Hazard statement
PNEC = Predicted No Effect Concentration
RRN = REACH Registration Number
Classification according to Regulation (EC) No. 1272/2008 [CLP/GHS]
Flam. Liq. 3, H226
Skin Irrit. 2, H315
Eye Dam. 1, H318
Procedure used to derive the classification according to Regulation (EC) No. 1272/2008 [CLP/GHS]
Classification Justification
Flam. Liq. 3, H226 On basis of test data
Skin Irrit. 2, H315 Calculation method
Eye Dam. 1, H318 Calculation method
Full text of abbreviated H : H225 Highly flammable liquid and vapour.
statements H226 Flammable liquid and vapour.
H311 Toxic in contact with skin.
H312 Harmful in contact with skin.
H314 Causes severe skin burns and eye damage.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H318 Causes serious eye damage.
H332 Harmful if inhaled.
H412 Harmful to aquatic life with long lasting effects.
Full text of classifications : Acute Tox. 3, H311 ACUTE TOXICITY: SKIN - Category 3
[CLP/GHS] Acute Tox. 4, H312 ACUTE TOXICITY: SKIN - Category 4
Acute Tox. 4, H332 ACUTE TOXICITY: INHALATION - Category 4
Aquatic Chronic 3, H412 AQUATIC TOXICITY (CHRONIC) - Category 3
Eye Dam. 1, H318 SERIOUS EYE DAMAGE/ EYE IRRITATION - Category 1
Flam. Liq. 2, H225 FLAMMABLE LIQUIDS - Category 2
Flam. Liq. 3, H226 FLAMMABLE LIQUIDS - Category 3
Skin Corr. 1B, H314 SKIN CORROSION/IRRITATION - Category 1B
Skin Irrit. 2, H315 SKIN CORROSION/IRRITATION - Category 2
Skin Sens. 1, H317 SKIN SENSITIZATION - Category 1
Full text of abbreviated R : R11- Highly flammable.
phrases R10- Flammable.
R20- Harmful by inhalation.
R20/21- Harmful by inhalation and in contact with skin.
R21/22- Harmful in contact with skin and if swallowed.
R34- Causes burns.
R41- Risk of serious damage to eyes.
R38- Irritating to skin.
R43- May cause sensitisation by skin contact.

Date of issue : 01.11.2012. 10/13


Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
Penguard - Comp. B

SECTION 16: Other information


R52/53- Harmful to aquatic organisms, may cause long-term adverse effects in the
aquatic environment.
Full text of classifications : F - Highly flammable
[DSD/DPD] C - Corrosive
Xn - Harmful
Xi - Irritant
Date of printing : 01.11.2012.
Date of issue/ Date of : 01.11.2012.
revision
Date of previous issue : No previous validation.
Version : 1
Notice to reader
To the best of our knowledge, the information contained herein is accurate. However, neither the above-named
supplier, nor any of its subsidiaries, assumes any liability whatsoever for the accuracy or completeness of the
information contained herein.
Final determination of suitability of any material is the sole responsibility of the user. All materials may present
unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot
guarantee that these are the only hazards that exist.

Date of issue : 01.11.2012. 11/13


Annex

Penguard - Comp. B
Exposure Scenario: Uses in Coatings - Industrial use
Sector of Use : Industrial use
Process Category : PROC05 PROC07 PROC08a PROC10
Environmental Release Categories : ERC4

Covers the use in coatings (paints, inks, adhesives, etc) including exposures during use (including product transfer and preparation, application by brush,
spray by hand or similar methods) and equipment cleaning.

Operational conditions and risk management measures


Control of worker exposure
Frequency and duration of use : Covers daily exposures up to 8 hours (unless stated differently).
General - Operational conditions : Assumes use at not more than 20C above ambient temperature (unless stated differently). Assumes a
good basic standard of occupational hygiene is implemented.
General - Risk Management Measures : Wear chemical-resistant gloves (tested to EN374) in combination with 'basic' employee training. Wear
suitable coveralls to prevent exposure to the skin. Use suitable eye protection. See Section 8 for
information on appropriate personal protective equipment.

Type of activity or process Risk Management Measures


Preparation of material for application : Provide a good standard of controlled ventilation (10 to 15 air changes per hour).
Roller, spreader, flow application : Provide extract ventilation to points where emissions occur.
Spraying - Manual : Provide a good standard of controlled ventilation (10 to 15 air changes per hour). Wear a respirator
conforming to EN140 with Type A/P2 filter or better.

Control of environmental exposure


Organisational measures to prevent/limit : Prevent environmental discharge consistent with regulatory requirements.
release from site
Conditions and measures related to external : External treatment and disposal of waste should comply with applicable local and/or national regulations.
treatment of waste for disposal See Section 13 for additional waste treatment information.
Conditions and measures related to external : External recovery and recycling of waste should comply with applicable local and/or national regulations.
recovery of waste

Additional information
The exposure scenario for the mixture is based on the following substances:
REACH #: 01-2119488216-32

Page: 12/13
Annex

Penguard - Comp. B
Exposure Scenario: Uses in Coatings - Professional use
Sector of Use : Professional use
Process Category : PROC05 PROC08a PROC10 PROC11
Environmental Release Categories : ERC8a ERC8d

Covers the use in coatings (paints, inks, adhesives, etc) including exposures during use (including product transfer and preparation, application by brush,
spray by hand or similar methods) and equipment cleaning.

Operational conditions and risk management measures


Control of worker exposure
Frequency and duration of use : Covers daily exposures up to 8 hours (unless stated differently).
General - Operational conditions : Assumes use at not more than 20C above ambient temperature (unless stated differently). Assumes a
good basic standard of occupational hygiene is implemented.
General - Risk Management Measures : Wear chemical-resistant gloves (tested to EN374) in combination with 'basic' employee training. Wear
suitable coveralls to prevent exposure to the skin. Use suitable eye protection. See Section 8 for
information on appropriate personal protective equipment.

Type of activity or process Risk Management Measures


Preparation of material for application - : Provide a good standard of controlled ventilation (10 to 15 air changes per hour). Avoid carrying out
Indoor. activities involving exposure for more than 1 hour.
or
Provide a good standard of controlled ventilation (10 to 15 air changes per hour). Wear a respirator
conforming to EN140 with Type A/P2 filter or better.
Preparation of material for application - : Ensure operation is undertaken outdoors. Avoid carrying out activities involving exposure for more than
Outdoor. 1 hour
or
Ensure operation is undertaken outdoors. Wear a respirator conforming to EN140 with Type A/P2 filter
or better.
Roller, spreader, flow application - Indoor. : Provide a good standard of controlled ventilation (10 to 15 air changes per hour). Wear a respirator
conforming to EN140 with Type A/P2 filter or better.
Roller, spreader, flow application - Outdoor. : Ensure operation is undertaken outdoors. Wear a respirator conforming to EN140 with Type A/P2 filter
or better.
Spraying - Manual - Indoor. : Minimise exposure by partial enclosure of the operation or equipment and provide extract ventilation at
openings. Wear a respirator conforming to EN140 with Type A/P2 filter or better.
Spraying - Manual - Outdoor. : Ensure operation is undertaken outdoors. Wear a full-face respirator conforming to EN136 with Type
A/P2 filter or better.

Control of environmental exposure


Organisational measures to prevent/limit : Prevent environmental discharge consistent with regulatory requirements.
release from site
Conditions and measures related to external : External treatment and disposal of waste should comply with applicable local and/or national regulations.
treatment of waste for disposal See Section 13 for additional waste treatment information.
Conditions and measures related to external : External recovery and recycling of waste should comply with applicable local and/or national regulations.
recovery of waste

Additional information
The exposure scenario for the mixture is based on the following substances:
REACH #: 01-2119488216-32

Page: 13/13