LAMPIRAN B

PERHITUNGAN

Run I, Bukaan Panas (Tube) = 30, Bukaan Dingin (Shell) = 90


1. Suhu 47 C
T1 = 42,7 C = 108.86 F
T2 = 41.2C = 106.16F
t1 = 29,7 C = 85.46F
t2 = 30,6 C = 87.08F
a. W Pada aliran panas
= 7,1L/menit = 40,890 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,45 Btu/lb F
Q = W.Cp(T1 T2)
40,890 = W 0,45 (108,86 106,16)
40,890 = 1.215W
W = 33,65 lb/hr

W Pada aliran dingin


= 4,309 L/menit = 24,81 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,45 Btu/lb F
Q = W.Cp(t2 t1)
24,81 = W 0,45 (87,08 85,46)
24,81 = 0,729W
W = 34,05 lb/hr

b. LMTD
(T1 - t2 )- (T2 - t1 )
LMTD = (T -t )
ln 1 2
(T2 - t1 )
(108,86- 87,08)- (106,16 - 85.46)
= (108,86- 87,08)
ln(106,16
- 85.46)

1,08 1,08
= 21,78 = 0,05 = 21,6
ln
20,7

(T1 - T2 ) (108,86 106,16 ) 2,7


c. R= = = = 1,6
(t2 -t1 ) (87,08 - 85.46) 1,6

(t2 - t1 ) (87,08 - 85.46) 2,7


d. S= (T1 -t1 )
= (108,86 85.46 ) = 23,4 = 0,12

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa :
Ft = 0,97
t=LMTD (Ft)= 21,6(0,97)= 20,952

f. Ta dan ta
108,86 + 106,16
Ta = = 107,51
2
85,46+87,08
ta = = 86,27
2

Temperatur rata Ta dan ta adalah Ta = 107,51 dan ta = 86,287

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft

Flow Area
D2 3,14 (0,042 ft)2
As = = = 0,0014 ft2
4 4

Mass Velocity
W
= 24035,71 lb
33,65
Gt= As = 0,0014 hr. ft2

Velocity Through Tube


Gt
V = 3600
24035,71
= 3600 62,5

= 0,11 fps

Pada Ta = 107,51F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 107,51F
diperoleh
diperoleh = 0,65 centipoises
= 0,65 2,42
= 1,573 lb ft hr

Gt
Ret=D ( )

Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 107,51F


diperoleh = 0,65 lb ft hr

= 0,65 2,42
= 1,573 lb ft hr
De Gs 0,042 24035,71
Ret= = = 641,77
1,573

L 8,66
= = 206,19
D 0,042

Dari Fig. 24 Kern, halaman 834 pada lampiran grafik diperoleh :


jH = 2,5
Pada Ta = 107,51F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel 4 Kern halaman
800 diperoleh:
C = 0,44 Btu/lbF
K = 0,3685 Btu/hr (ft)2(F/ft)
1 1
(c . )3 [(0,44)(1,573)]3 0,884
= = = 2.39
k 0,3685 0,3685
1
K (C )3
hi=JH (D) [ ] t
K

0,3685
=2,5 ( 0,042 ) [2,39] (1)

= 52,42

Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:


hi = 52,42 1,03
=53,99
0,041
hio = 53,99 = 52,70
0,042

Clean overall coefficient UC :


52,70 6,33
UC = + = = 5,65 Btu/(hr)(ft2)(F)
52,70 + 6,33

Design overall coefficient UD :

40,890
= = = 1410 Btu/(hr)(ft2)(F)
. 0,0014 ft2 (20,952)

Dirt factor Rd :
5,65 1410
Rd = = 5,65 = -0,176
1410

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
Flow Area
D2 3,14 (0,53)2
As= = = 0,22 ft2
4 4
Mass Velocity
W
= 154,77 lb
34,05
Gs= As = 0,22 hr ft2

Pada ta = 86,27
Dari lampiran grafik Fig. 14 Kern halaman 823 pada ta 86,27F diperoleh
= 0,86 centipoise
= 0,86 2,42
= 2,081 lb ft hr

De Gs 0,53 154,77
Res= = = 39,42
2,081

Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :


jH = 3,5

Pada ta = 86,27F
Dari lampiran grafik Fig. 3 Kern halaman 805 dan Tabel 4 Kern halaman
800 diperoleh:
C = 0,43 Btu/lbF
K = 0,3685 Btu/hr (ft)2(F/ft)
1 1
(c . )3 [(0,43)(2,081 )]3
= = 2,6
k 0,3685

1
K (C )3
ho=JH (D) [ ] s
K

1
ho K (C. )3 0,3685
=JH (D) [ ] = 3,5 ( ) [2,6 ]= 6,33
s K 0,53

Corrected coefficient:
ho
ho = s = 6,33 1 = 6,33 Btu/(hr)(ft2)(F)

Clean overall coefficient UC :


52,70 6,33
UC = + = 52,70 = 5,65 Btu/(hr)(ft2)(F)
5 + 6,33

Design overall coefficient UD :

40,896
= = = 8,873 Btu/(hr)(ft2)(F)
. 0,22 ft2 (20,952)
Dirt factor Rd :
4,01 8,873
Rd = = 4,01 = -0,137
8,873

Wwwwwwwwwwwwww
Run I, Bukaan Panas (Tube) = 30, Bukaan Dingin (Shell) = 90
2. Suhu 53C
T1 = 48,2C = 118,76 F
T2 = 45,8 C = 114,44 F
t1 = 31 C = 87,8 F
t2 = 32 C = 89,6 F
Diketahui:
a. W pada aliran panas dengan suhu 111,74 F
= 17,5 L/menit = 100,86 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,43 Btu/lb F
Q = W.Cp (T1 - T2 )
100,86 = W 0,43 (111,74 - 108,86)
100,86 = 1,2384 W
W = 81,444 lb/hr

W pada aliran dingin dengan suhu 89,78 F


= 6,8 L/menit = 39,19 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,43 Btu/lb F
Q = W.Cp (t2 - t1 )
39,19 = W 0,43 (93,38 - 89,78)
39,19 = 1,548 W
W = 25,317 lb/hr

t2 - t1 6,48
b. LMTD = = = 18,57
2,3 log t2 / t1 2,3 log 21,96/15,48
(T1 - T2 ) (111,74 108,86) 2,88
c. R = = (93,38 - 89,78)
= = 0,8
(t 2 - t 1 ) 3,6
(t2 - t1 ) (93,38 - 89,78) 3,6
d. S = (T1 - t1 )
= (111,74 - 89,78)
= = 0,164
21,96

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa:
Ft = 0,99
t = LMTD (Ft) = 18,57 (0,99) = 18,384
f. Ta dan ta:
111,74 + 108,86
Ta = = 110,3,65
2
93,38 + 89,78
ta = = 91,58
2

Temperatur rata-rata Ta dan ta adalah Ta = 110,3 dan ta = 91,58

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang tube (L) = 264 cm = 8,66 ft
Flow Area
D2 3,14 (0,042)2
a't = = = 0,00138 ft2
4 4

Mass Velocity
W 81,444 lb/hr
Gt = = = 59.017,391 lb(hr) 2
At 0,00138 2
Velocity through tube:
Gt
V =
3600
59.017,391
=
3600 62,5

= 0,262 fps
Pada Ta = 110,3
Dari lampiran grafik Fig. 14 Kern, halaman, 823 pada Ta = 110,3 F
diperoleh
= 0,65 centipoises
= 0,65 2,42 = 1,573 lb/(ft)(hr)
DGt 0,042 59.017,391
Ret = = = 1.576
1,573

L 8,66
= 0,042 = 206,19
D
Dari Fig. 24 Kern halaman 834 pada lampiran grafik diperoleh :
JH = 3,5
Ta = 110,3 F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel. 4 Kern, halaman
800 diperoleh:
c = 0,43 Btu/(lb)(F)
k = 0,3685 Btu/(hr)(ft2)(F/ft)
Maka:
c. 1 0 ,43 1,573 1
( )3 = ( )3 = 1,222
0,3685

c. 1
hi = JH () ( )3 t
0,3685
= 3,5 1,222 = 37,526
t 0,042

Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:


hi = 37,526 1,04
=39,027
0,041
hio = 39,027 = 38,098
0,042

Clean overall coefficient UC :


hioho 38,098 2,90
Uc = hio+ho = = 2,695 Btu/(hr)(ft2)(oF)
38,098+2,90

Design overall coefficient UD :


100,86
= = = 3.919 Btu/(hr)(ft2)(F)
. 0,0014 ft2 (18,384)

Dirt factor Rd :
2,695 3919
= = = -0,116
2,695 3919

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
Flow Area
D2 3,14 (0,53)2
As = = = 0,221 ft2
4 4

Mass Velocity
W 25,317 lb/hr
Gs = = = 114,557 lb(hr) 2
As 0,221 2
Pada ta= 91,58

Res =

Dari lampiran grafik Fig. 14 Kern, halaman 823 pada ta = 91,58 F


diperoleh,
= 0,79 centipoises
= 0,79 2,42 = 1,9118 lb/(ft) (hr)
0,53 114,557
Res = = 31,758
1,9118

Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :


JH = 3,2
Pada tc = 91,58 F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Table. 4 Kern, halaman
800 diperoleh:
c = 0,43 Btu/(lb)(F)
k = 0,3685 Btu/(hr)(ft2)(F/ft)
Maka:
c. 1 0 ,43 1,9118 1
( )3 = ( )3 = 1,303
0,3685

c. 1
ho = JH () ( )3 s
0,3685
= 3,2 1,303
s 0,53

= 2,90
Corrected coefficient,
ho
ho = s s = 2,90 1 = 2,90 Btu/(hr)(ft2)( oF)

Clean overall coefficient UC :


hioho 38,098 2,90
Uc = hio+ho = 38,098+2,90
= 2,695 Btu/(hr)(ft2)(oF)
Design overall coefficient UD :
39,19
= = = 9,646 Btu/(hr)(ft2)(F)
. 0,221 ft2 (18,384)

Dirt factor Rd :
2,695 9,646
= = = -0,27
2,695 9,646