7.flash Distiler

This document provides design specifications for two flash distillers (FD-01 and FD-02) used to separate formic acid from liquid mixtures. FD-01 has a capacity of 59,800.8582 kg/hr, operates at 243.27°C and 6.6 atm, and has dimensions of 1.06m diameter, 2.46m height, and 0.00644m wall thickness. FD-02 has a capacity of 55,498.2837 kg/hr, operates at 230.2060°C and 6.6 atm, and has dimensions of 1.7874m diameter, 2.69m height, and 0.0104m wall thickness. Both units are designed with

Uploaded by

Na-na Oktavia
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views

7.flash Distiler

This document provides design specifications for two flash distillers (FD-01 and FD-02) used to separate formic acid from liquid mixtures. FD-01 has a capacity of 59,800.8582 kg/hr, operates at 243.27°C and 6.6 atm, and has dimensions of 1.06m diameter, 2.46m height, and 0.00644m wall thickness. FD-02 has a capacity of 55,498.2837 kg/hr, operates at 230.2060°C and 6.6 atm, and has dimensions of 1.7874m diameter, 2.69m height, and 0.0104m wall thickness. Both units are designed with

Uploaded by

Na-na Oktavia
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 35

347

Flash Disttiler (FD - 01)


Fungsi

: Untuk memisahkan asam formiat yang terkandung dalam


larutan campuran

Type

: Silinder Vertikal dengan alas dan tutup elipsoidal

Gambar

:
Out top
In

Out bottom

Data :
Tekanan, P

= 6,6 atm

Temperatur, T

= 243,27oC

Laju alir Uap, Qv

= 11466,6214 kg/jam

Laju alir liquid

, Ql

Densitas likuid

= 4015,9000 kg/m3

Densitas Uap

= 3,9609 kg/m3

= 48334,2368 kg/jam

a. Vapor velocity ,Uv :


Uv = 0,07 ((L-v)/2.16)1/2
= 0,07 ((4015,9000-3,9609)/2,16)1/2
= 0,9050 m/det
b. Vapor Volumetrik, Qv :
Qv = Laju alir uap/v
= 11466,6214/(3,9609 x 3600)
= 0,8041 m3/det

348

c. Vessel Area, A :
A = Qv/Uv
= (0,8041m3/det) / (0,9050 m/det)
= 0,8885 m2
d. Diameter Vessel , D:
D = (4A/)1/2

= [(4 x 0,8885 m2)/3,14]1/2


= 1,0639 m

e. Liquid volumetrik flow rate, q :


q

= Laju alir liq/L


= 11466,6214 / (4015,900 x 3600)
= 0,003343 m3/det

f. Volume untuk 300 second Hold Up :


V = q x 300 second
= 0,003343 m3/det x 300 det
= 1,0029 m3
g. Volume elipsoidal head (Ve)
Ve = ( x D^3)/24
= (3,14 x 1.06393)/24
= 0,16 m3
h. Ketinggian liquid, L :
L = V/A = 1,0029 m3/ 0,8885 m2
= 1,1288 m
Tinggi Head (ellipsoidal) = He

= D = 0,27 m

i. Tinggi Vessel, H:
H = D + L + He= (1,0639 + 1,1288 + 0,27) m

349

= 2,46 m
j. Tebal dinding , t :

P x r
Cc
S.Ej
0,6
P
t =

(Peters, Tabel 4, Hal.537, Edisi 4)

Dimana :
P = 6,6 atm
r = Jari-jari vessel

= 0.5319 m

S = Working stress allowable

= 932,2297 atm

Ej = Welding Join Efisiensi

= 0,85

Cc = Tebal korosi yang diizinkan = 0,003175 m

(Perrys hand book)

Maka :
t

6,6 atm x 0,5319m


(932,2297 x 0,85) ( 0,6 x 6,6 atm)

0,0074 m

0,74 cm

OD

0,003175 m

= D + 2t
= 1,0639 m + (2 x 0,0074 )
= 1,0787 m

k. Perhitungan Desain koil


Fluida Panas

Fluida Dingin

Perhitungan:
1.

Beban Panas FD-01

: Steam
W

= 1.277,0829 kg/jam = 2.815,4826 lb/jam

T1

= 300.0000oC

= 572 oF

T2

= 300.0000oC

= 572 oF

: Aliran 14
W

= 59.800,8582 kg/jam = 131.838,1680 lb/jam

t1

= 250 oC

= 482 oF

t2

= 243,27oC

= 469 oF

350

Q = 769.723,4446 kJ/jam = 729.567,7422 Btu/jam

2.

LMTD
Fluida Panas
(oF)
572
Suhu tinggi
572
Suhu rendah
0
Selisih
t 2 t1
LMTD = ln (t 2 / t1 ) = 95.9253oF
t = 94.9660 oF
3. Tc = T avg
= 572 oF
tc = t avg

Fluida Dingin
(oF)
469,9
482

Selisih
102,1
90
12,11

= 475,95oF

Asumsi UD = 250 Btu/hr.ft2.oF


250-500 (Tabel 8. Kern)
729567.7422
A = 250 94.9660 = 30,4223 ft2

Karena A< 200 ft2, maka dipilih HE jenis Double Pipe Heat Exchanger.
Desain Koil Pemanas
1. Rasiopanjang coil terhadap diameter tangki, LC/ Dt = 0,65
2. Rasio diameter coil terhadap diameter tangki, DC/Dt = 0,70
3. Rasiotinggi coil daridasartangkiterhadap diameter tangki, HC/Dt = 0,15
4. Rasio diameter tube coil terhadap diameter pengaduk, Dct/Di = 0,088
5. Rasiojarakantara coil terhadap diameter tube coil, Sc/Dct = 2,00
1. Panjang coil

= 0,692 m

2. Diameter Coil = 0,745 m


3. Tinggi Coil

= 0,160 m

4. D Tube Coil

= 0,019 m

5. Jarak Coil

= 0,038 m

351

Data Pipa
IPS (in)
SN
OD (in)
ID (in)
a (ft2/ft)

Inner Pipe
22,000
20,000
22,000
21,35
5,747

a. Flow Area, ap
D = 21,350 in
ap

= 4 D2

= 1,7792 ft

= 4 (1,7792)2 = 2,4849 ft2

b. Kecepatan Massa, Gp

2815,4826
Gp = w/ap = 2,4849
= 1.133,0522 lb/hr ft2
c. Reynold number, Re
Pada Tavg = 572 oF

= 0,0490 lb/ft.hr

Rep

= D.Gp/
= 41136,39

d. JH = 130

(Fig. 24, Kern)

Pada tavg = 572 oF


e. k = 0,0237 Btu/hr.ft2(oF/ft)
cp = 0,4790 Btu/lb.oF

= 0,9968

352

f. hi

k
= JH De

0,14

= 1,7262 Btu/hr.ft2.oF
g. Koreksi hi pada permukaan OD
hio = hi x ID/OD
= 1,6752 Btu/hr.ft2.oF
h. Clean Overall Coefficient, UC
hioxho
UC = hio ho = 1,4165 Btu/hr.ft2.oF

i. Design Overall Coefficient, UD


1
1

Rd
UD UC

(Pers. 6.10)

Rd ditentukan 0,002 untuk masa service 1 tahun


1
1

0,002
U D 1,4165

UD = 1,4125 Btu/hr.ft2.oF

j.

Q
U D . t Required Length
A=

= 45016,397 ft2

Dari tabel 11 Kern, untuk 22-in IPS standard pipe, external surface/foot
length = 5,7470 ft
Luas permukaan antar 1 putaran, jika diameter helix (Dh) adalah 3 ft
Ap = 54,13674 ft2
Jumlah putaran yang dibutuhkan

45016,397
= 54,13674 = 831,5313

Panjang koil yang dibutuhkan

= 7833,0255 ft

353

Nama Alat

IDENTIFIKASI
Flash Disttiler

Kode Alat

FD 01

Jumlah

1 buah

Fungsi

Menguapkan sebagian umpan dari produk

Tipe
Kapasitas
Temperatur
Tekanan
ID

bottom KOD-01
DATA DESIGN
Silinder vertikal dengan tutup elipsoidal
59,8008 m3
243,27 C
6,6 atm
1,06 m

OD
Tinggi
Tebal
Bahan Konstruksi
Selesai fd 1

1,07 m
2,4586 m
0,00644 m
Carbon Steel

Flash Disttiler (FD - 02)


Fungsi

: Menguapkan sebagian likuid yang merupakan produk bottom


KD-01

354

Type

: Silinder Vertikal dengan alas dan tutup elipsoidal

Gambar

:
Out top
In

Out bottom

Data :
Tekanan, P

= 6,6 atm

Temperatur, T

= 230,2060oC

Laju alir Uap, Qv

= 12.500,0023 kg/jam

Laju alir liquid

, Ql

Densitas likuid

= 4.015,9 kg/m3

Densitas Uap

= 1,8351 kg/m3

= 55.498,2837 kg/jam

a. Vapor velocity ,Uv :


Uv = 0,07 x 0,15 ((L-v)/2.16)1/2
= 0,07 ((4.015,9 -1,8351)/2.16)1/2
= 0,7544 m/det
b. Vapor Volumetrik, Qv :
Qv = Laju alir uap/v
= 12.500,0023 / (1,8351 x 3600)
= 1,8921 m3/det
c. Vessel Area, A :
A = Qv/Uv
= (1,8921 m3/det) / (0,7544 m/det)

355

= 2.5081 m2
d. Diameter Vessel , D:
D = (4A/)1/2

= [(4 x 2.5081 m2)/3,14]1/2


= 1,7874 m

e. Liquid volumetrik flow rate, q :


q

= Laju alir liq/L


= 55.498,2837 / (4.015,9 x 3600)
= 0,003838 m3/det

f. Volume untuk 300 second Hold Up :


V = q x 300 second
= 0,003838 m3/det x 300 det
= 1,1516 m3
g. Volume elipsoidal head (Ve)
Ve = ( x D^3)/24
= (3,14 x 1,78743)/24
= 0,75 m3
h. Ketinggian liquid, L :
L = V/A = 1,1516 / 2.5081 m2
= 0,4591 m
Tinggi Head (ellipsoidal) = He

= D = 0,45 m

i. Tinggi Vessel, H:
H = D + L + He= (1,7874 + 0,4591 + 0,45) m
= 2,69 m
j. Tebal dinding , t :

356

P x r
Cc
t = S.Ej - 0,6 P

(Peters, Tabel 4, Hal.537, Edisi 4)

Dimana :
P = 6,6 atm
r

= Jari-jari vessel

= 0,8937 m

S = Working stress allowable

= 932,2297 atm

Ej = Welding Join Efisiensi

= 0,85

Cc = Tebal korosi yang diizinkan = 0,003175 m

(Perrys hand book)

Maka :
t

1 atm x 0,8937 m
(932,2297 x 0,85) ( 0,6 x 6,6 atm)

0,0104 m

1,04 cm

OD

0,003175 m

= D + 2t
= 1,7874 m + (2 x 0,0104 )
= 1,8084 m

k. Perhitungan Desain koil


Fluida Panas

Fluida Dingin

: Steam
W

= 1.292,8631 kg/jam = 3333,3666 lb/jam

T1

= 300.0000oC

= 572 oF

T2

= 300.0000oC

= 572 oF

: Aliran 20
W

= 67.998,2860 kg/jam

= 100623,8211 lb/jam

t1

= 228,41 oC

= 443,14 oF

t2

= 230,20 oC

= 446,37 oF

Perhitungan:
4.

Beban Panas FD-02


Q = 715.884,1805 kJ/jam = 678.537,2187Btu/jam

5.

LMTD

357

Fluida Panas
(oF)
572
572
0

Fluida Dingin
(oF)
446,4
443,1

Suhu tinggi
Suhu rendah
Selisih
t 2 t1
LMTD = ln ( t 2 / t1 ) = 127,2371oF

Selisih
125,6
128,86
-3,23

t = 125,9647 oF

6. Tc = T avg
tc = t avg

= 572 oF
= 444,76 oF

Asumsi UD = 250 Btu/hr.ft2.oF


250-500 (Tabel 8. Kern)
678.537,2187
A = 250 127,2371 = 21,3314 ft2

Karena A< 200 ft2, maka dipilih HE jenis Double Pipe Heat Exchanger.
Desain Koil Pemanas
1. Rasiopanjang coil terhadap diameter tangki, LC/ Dt = 0,65
2. Rasio diameter coil terhadap diameter tangki, DC/Dt = 0,70
3. Rasiotinggi coil daridasartangkiterhadap diameter tangki, HC/Dt = 0,15
4. Rasio diameter tube coil terhadap diameter pengaduk, Dct/Di = 0,088
5. Rasiojarakantara coil terhadap diameter tube coil, Sc/Dct = 2,00
1. Panjang coil

= 0,692 m

2. Diameter Coil = 0,745 m


3. Tinggi Coil

= 0,160 m

4. D Tube Coil

= 0,019 m

5. Jarak Coil

= 0,038 m
Data Pipa
IPS (in)
SN
OD (in)
ID (in)
a (ft2/ft)

Inner Pipe
22,000
20,000
22,000
21,35
5,747

358

k. Flow Area, ap
D = 21,350 in
ap

= 4 D2

= 1,7792 ft

= 4 (1,7792)2 = 2,4849 ft2

l. Kecepatan Massa, Gp

2850,2719
Gp = w/ap = 2,4849
= 1.147,0527 lb/hr ft2
m. Reynold number, Re
Pada Tavg = 572 oF

= 0,0203 lb/ft.hr

Rep

= D.Gp/
= 41644,69

n. JH

= 60

(Fig. 24, Kern)

Pada tavg = 572 oF


o. k = 0,0237 Btu/hr.ft2(oF/ft)
cp = 0,4790 Btu/lb.oF

p. hi

= 0,9968
k c

= JH De k

0,14

= 0,7967 Btu/hr.ft2.oF
q. Koreksi hi pada permukaan OD
hio = hi x ID/OD
= 0,7732 Btu/hr.ft2.oF
r. Clean Overall Coefficient, UC
hioxho
UC = hio ho = 0,7131 Btu/hr.ft2.oF

359

s. Design Overall Coefficient, UD


1
1

Rd
UD UC

(Pers. 6.10)

Rd ditentukan 0,002 untuk masa service 1 tahun


1
1

0,002
U D 0,6244

UD = 0,7120 Btu/hr.ft2.oF
Q
U D . t Required Length

t.

A=

= 311.297,4420 ft2

Dari tabel 11 Kern, untuk 22-in IPS standard pipe, external surface/foot
length = 5,7470 ft
Luas permukaan antar 1 putaran, jika diameter helix (Dh) adalah 3 ft
Ap = 54,13674 ft2
Jumlah putaran yang dibutuhkan

8456,020
= 54,13674 = 156,1974

Panjang koil yang dibutuhkan

= 54166,9466 ft

Nama Alat

IDENTIFIKASI
Flash Disttiler

Kode Alat

FD 02

Jumlah

1 buah

Fungsi

Menguapkan sebagian umpan dari produk

Tipe
Kapasitas
Temperatur
Tekanan
ID

bottom KD-01
DATA DESIGN
Silinder vertikal dengan tutup elipsoidal
45642,25 m3
206 C
6,6 atm
1,7874 m

OD
Tinggi

1,8084 m
2,6935 m

360

Tebal
Bahan Konstruksi
Selesai fd 2

0,0104 m
Carbon Steel

Flash Disttiler (FD - 03)


Fungsi

: Menguapkan sebagian likuid yang merupakan produk bottom


EV-03

361

Type

: Silinder Vertikal dengan alas dan tutup elipsoidal

Gambar

:
Out top
In

Out bottom

Data :
Tekanan, P

= 0,48 atm

Temperatur, T

= 114,1367 oC

Laju alir Uap, Qv

= 3985,5429 kg/jam

Laju alir liquid

, Ql

Densitas liquid

= 4015,9000 kg/m3

Densitas Uap

= 1,4633 kg/m3

= 6297,3622 kg/jam

a. Vapor velocity ,Uv :


Uv = 0,07 x 0,15 ((L-v)/2.16)1/2
= 0,07 ((4015,9000-1,4633)/2.16)1/2
= 0,4526 m/det
b. Vapor Volumetrik, Qv :
Qv = Laju alir uap/v
= 3985,5429/(1,4633 x 3600)
= 0,7565 m3/det
c. Vessel Area, A :
A = Qv/Uv
= (0,7565 m3/det) / (0,4526 m/det)

362

= 1,6713 m2
d. Diameter Vessel , D:
D = (4A/)1/2

= [(4 x 1,6713 m2)/3,14]1/2


= 1,4591 m

e. Liquid volumetrik flow rate, q :


q

= Laju alir liq/L


= 6.297,3622 / (4.015,90 x 3600)
= 0,0043 m3/det

f. Volume untuk 300 second Hold Up :


V = q x 300 second
= 0,0043 m3/det x 300 det
= 1,3068 m3
g. Volume elipsoidal head (Ve)
Ve = ( x D^3)/24
= (3,14 x 1,45913)/24
= 0,41 m3
h. Ketinggian liquid, L :
L = V/A = 1,3068 m3/ 1,6713 m2
= 0,7819 m
Tinggi Head (ellipsoidal) = He

= D = 0,36 m

i. Tinggi Vessel, H:
H = D + L + He= (1,4591 + 0,7819 + 0,36) m
= 2,61 m

j. Tebal dinding , t :

P x r
Cc
S.Ej
0,6
P
t =

(Peters, Tabel 4, Hal.537, Edisi 4)

363

Dimana :
P = 0,48 atm
r

= Jari-jari vessel

= 0,7295 m

S = Working stress allowable

= 932,2297 atm

Ej = Welding Join Efisiensi

= 0,85

Cc = Tebal korosi yang diizinkan = 0,003175 m

(Perrys hand book)

Maka :
t

0,48 atm x 0,7295 m


(932,2297 x 0,85) ( 0,6 x 0,48 atm)

0,0034 m

0,3443 cm

OD

0,003175 m

= D + 2t
= 1,4591 m + (2 x 0,0034 )
= 1,4660 m

k. Perhitungan Desain koil


Fluida Panas

Fluida Dingin

: Steam
W

= 1320,6385 kg/jam

= 2911,5062 lb/jam

T1

= 300.0000oC

= 572 oF

T2

= 300.0000oC

= 572 oF

: Aliran 25
W

= 66.964,9050kg/jam = 147.632,1691 lb/jam

t1

= 90 oC

= 194 oF

t2

= 144,13oC

= 237,45 oF

Perhitungan:
7.

Beban Panas FD-03


Q = 795.975,2662 kJ/jam = 754.450,0326 Btu/jam

8.

LMTD
Fluida Panas
(oF)

Fluida Dingin
(oF)

Selisih

364

572
572
0

Suhu tinggi
Suhu rendah
Selisih
t 2 t1
LMTD = ln ( t 2 / t1 ) = 355,8349oF

237,4
194,0

334,6
378,0
-43,45

t = 352,2766 oF

9. Tc = T avg
tc = t avg

= 572 oF
= 419,00 oF

Asumsi UD = 250 Btu/hr.ft2.oF


250-500 (Tabel 8. Kern)
754.450,0326
A = 250 355,8349 = 8,4809 ft2

Karena A< 200 ft2, maka dipilih HE jenis Double Pipe Heat Exchanger.
Desain Koil Pemanas
1. Rasiopanjang coil terhadap diameter tangki, LC/ Dt = 0,65
2. Rasio diameter coil terhadap diameter tangki, DC/Dt = 0,70
3. Rasiotinggi coil daridasartangkiterhadap diameter tangki, HC/Dt = 0,15
4. Rasio diameter tube coil terhadap diameter pengaduk, Dct/Di = 0,088
5. Rasiojarakantara coil terhadap diameter tube coil, Sc/Dct = 2,00
1. Panjang coil

= 0,692 m

2. Diameter Coil = 0,745 m


3. Tinggi Coil

= 0,160 m

4. D Tube Coil

= 0,019 m

5. Jarak Coil

= 0,038 m

Data Pipa
IPS (in)
SN

Inner Pipe
22,000
20,000

365

OD (in)
ID (in)
a (ft2/ft)

22,000
21,35
5,747

a. Flow Area, ap
D = 21,350 in
ap

= 4 D2

= 1,7792 ft

= 4 (1,7792)2 = 2,4849 ft2

b. Kecepatan Massa, Gp

2911,5062
Gp = w/ap = 2,4849
= 1.171,6956 lb/hr ft2
c. Reynold number, Re
Pada Tavg = 572 oF

= 0,0203 lb/ft.hr

Rep

= D.Gp/
= 42539,37

d. JH

= 20

(Fig. 24, Kern)

Pada tavg = 572 oF


e. k = 0,0237 Btu/hr.ft2(oF/ft)
cp = 0,4790 Btu/lb.oF

f. hi

= 0,9968
k c

= JH De k

0,14

= 0,2656 Btu/hr.ft2.oF
g. Koreksi hi pada permukaan OD
hio = hi x ID/OD
= 0,2577 Btu/hr.ft2.oF

366

h. Clean Overall Coefficient, UC


hioxho
UC = hio ho = 0,2507 Btu/hr.ft2.oF

i. Design Overall Coefficient, UD


1
1

Rd
UD UC

(Pers. 6.10)

Rd ditentukan 0,002 untuk masa service 1 tahun


1
1

0,002
U D 0,0257

UD = 0,2506 Btu/hr.ft2.oF

j.

Q
U D . t Required Length
A=

= 73.122,24 ft2

Dari tabel 11 Kern, untuk 22-in IPS standard pipe, external surface/foot
length = 5,7470 ft
Luas permukaan antar 1 putaran, jika diameter helix (Dh) adalah 3 ft
Ap = 54,13674 ft2
Jumlah putaran yang dibutuhkan

73.122,24
= 54,13674 = 1350,6953

Panjang koil yang dibutuhkan

= 12.723,5506 ft

Nama Alat

IDENTIFIKASI
Flash Disttiler

367

Kode Alat

EV 04

Jumlah

1 buah

Fungsi

Menguapkan sebagian umpan dari produk

Tipe
Kapasitas
Temperatur
Tekanan
ID

bottom EV-03
DATA DESIGN
Silinder vertikal dengan tutup elipsoidal
66.964,9051 m3
114,13 C
0,48 atm
1,4591 m

OD
Tinggi
Tebal
Bahan Konstruksi

1,4660 m
2,60 m
0,0034 m
Carbon Steel

Selesai fd 3

Flash Disttiler (FD - 04)


Fungsi

: Menguapkan sebagian likuid yang merupakan produk bottom


EV-03

Type
Gambar

: Silinder Vertikal dengan alas dan tutup elipsoidal


:

368

Out top
In

Out bottom

Data :
Tekanan, P

= 2 atm

Temperatur, T

= 180,87 oC

Laju alir Uap, Qv

= 11.958,2135 kg/jam

Laju alir liquid

, Ql

Densitas liquid

= 4015,9000 kg/m3

Densitas Uap

= 1,7839 kg/m3

= 51.021,1487 kg/jam

a. Vapor velocity ,Uv :


Uv = 0,07 x 0,15 ((L-v)/2.16)1/2
= 0,07 ((4015,9000-1,7839)/2.16)1/2
= 0,4526 m/det
b. Vapor Volumetrik, Qv :
Qv = Laju alir uap/v
= 11.958,2135/(1,7839 x 3600)
= 1,8620 m3/det
c. Vessel Area, A :
A = Qv/Uv
= (1,8620 m3/det) / (0,4526 m/det)
= 4,1138 m2

369

d. Diameter Vessel , D:
D = (4A/)1/2

= [(4 x 4,1138 m2)/3,14]1/2


= 2,2892 m

e. Liquid volumetrik flow rate, q :


q

= Laju alir liq/L


= 51.021,1487 / (4.015,90 x 3600)
= 0,0035 m3/det

f. Volume untuk 300 second Hold Up :


V = q x 300 second
= 0,0043 m3/det x 300 det
= 1,3068 m3
g. Volume elipsoidal head (Ve)
Ve = ( x D^3)/24
= (3,14 x 2,28923)/24
= 1,57 m3
h. Ketinggian liquid, L :
L = V/A = 1,3068 m3/ 4,1138 m2
= 0,2573 m
Tinggi Head (ellipsoidal) = He

= D = 0,57 m

i. Tinggi Vessel, H:
H = D + L + He= (2,2892 + 0,2573 + 0,57) m
= 3,12 m

j. Tebal dinding , t :

P x r
Cc
t = S.Ej - 0,6 P
Dimana :
P = 2 atm

(Peters, Tabel 4, Hal.537, Edisi 4)

370

= Jari-jari vessel

= 1,144 m

S = Working stress allowable

= 932,2297 atm

Ej = Welding Join Efisiensi

= 0,85

Cc = Tebal korosi yang diizinkan = 0,003175 m

(Perrys hand book)

Maka :
t

2 atm x 1,144 m
(932,2297 x 0,85) ( 0,6 x 2 atm)

0,0058 m

0,5893 cm

OD

0,003175 m

= D + 2t
= 2,2892 m + (2 x 0,0058 )
= 2,30 m

k. Perhitungan Desain koil


Fluida Panas

Fluida Dingin

: Steam
W

= 772,1019 kg/jam

= 1.702,1913 lb/jam

T1

= 300.0000oC

= 572 oF

T2

= 300.0000oC

= 572 oF

: Aliran 31
W

= 46.5361,27 kg/jam = 1.025.944,7696 lb/jam

t1

= 170 oC

= 338,00 oF

t2

= 180,87oC

= 357,57 oF

Perhitungan:
10.

Beban Panas FD-04


Q = 465.361,273 kJ/jam = 441.083,8407 Btu/jam

11.

LMTD
Fluida Panas
(oF)
572
572
0

Suhu tinggi
Suhu rendah
Selisih

Fluida Dingin
(oF)
357,6
338,0

Selisih
214,4
234,0
-19,57

371

t 2 t1
LMTD = ln ( t 2 / t1 ) = 224,0742oF
t = 221,8335 oF

12. Tc = T avg
tc = t avg

= 572 oF
= 347,78 oF

Asumsi UD = 250 Btu/hr.ft2.oF


250-500 (Tabel 8. Kern)
441.083,8407
A = 250 224,0742 = 7,8739 ft2

Karena A< 200 ft2, maka dipilih HE jenis Double Pipe Heat Exchanger.
Desain Koil Pemanas
1. Rasiopanjang coil terhadap diameter tangki, LC/ Dt = 0,65
2. Rasio diameter coil terhadap diameter tangki, DC/Dt = 0,70
3. Rasiotinggi coil daridasartangkiterhadap diameter tangki, HC/Dt = 0,15
4. Rasio diameter tube coil terhadap diameter pengaduk, Dct/Di = 0,088
5. Rasiojarakantara coil terhadap diameter tube coil, Sc/Dct = 2,00
1. Panjang coil

= 0,692 m

2. Diameter Coil = 0,745 m


3. Tinggi Coil

= 0,160 m

4. D Tube Coil

= 0,019 m

5. Jarak Coil

= 0,038 m

Data Pipa
IPS (in)
SN
OD (in)
ID (in)
a (ft2/ft)

Inner Pipe
22,000
20,000
22,000
21,35
5,747

372

k. Flow Area, ap
D = 21,350 in
ap

= 4 D2

= 1,7792 ft

= 4 (1,7792)2 = 2,4849 ft2

l. Kecepatan Massa, Gp

1702,1913
Gp = w/ap = 2,4849
= 685,0235 lb/hr ft2
m. Reynold number, Re
Pada Tavg = 572 oF

= 0,0203 lb/ft.hr

Rep

= D.Gp/
= 24.870,34

n. JH

= 100

(Fig. 24, Kern)

Pada tavg = 572 oF


o. k = 0,0237 Btu/hr.ft2(oF/ft)
cp = 0,4790 Btu/lb.oF

p. hi

= 0,9968
k c

= JH De k

0,14

= 1,3278 Btu/hr.ft2.oF
q. Koreksi hi pada permukaan OD
hio = hi x ID/OD
= 1,2886 Btu/hr.ft2.oF
r. Clean Overall Coefficient, UC
hioxho
UC = hio ho = 1,1299 Btu/hr.ft2.oF

373

s. Design Overall Coefficient, UD


1
1

Rd
UD UC

(Pers. 6.10)

Rd ditentukan 0,002 untuk masa service 1 tahun


1
1

0,002
U D 1,1299

UD = 1,1273 Btu/hr.ft2.oF

t.

Q
U D . t Required Length
A=

= 21.096,659 ft2

Dari tabel 11 Kern, untuk 22-in IPS standard pipe, external surface/foot
length = 5,7470 ft
Luas permukaan antar 1 putaran, jika diameter helix (Dh) adalah 3 ft
Ap = 54,13674 ft2
Jumlah putaran yang dibutuhkan

21.096,659
= 54,13674 = 389,6920

Panjang koil yang dibutuhkan

= 3670,8994 ft

Nama Alat

IDENTIFIKASI
Flash Disttiler

Kode Alat

FD 04

Jumlah

1 buah

Fungsi

Menguapkan sebagian umpan dari produk

374

Tipe
Kapasitas
Temperatur
Tekanan
ID

bottom EV-03
DATA DESIGN
Silinder vertikal dengan tutup elipsoidal
465.361,2729 m3
180,87 C
0,48 atm
2,2892 m

OD
Tinggi
Tebal
Bahan Konstruksi

2,3010 m
3,11 m
0,0058 m
Carbon Steel

Selesai fd 4

Flash Disttiler (FD - 05)


Fungsi

: Menguapkan sebagian likuid yang merupakan produk bottom


EV-03

Type
Gambar

: Silinder Vertikal dengan alas dan tutup elipsoidal


:

375

Out top
In

Out bottom

Data :
Tekanan, P

= 2,1 atm

Temperatur, T

= 187,36 oC

Laju alir Uap, Qv

= 11715,0523 kg/jam

Laju alir liquid

, Ql

Densitas liquid

= 4015,9000 kg/m3

Densitas Uap

= 1,8657 kg/m3

= 47595,7300 kg/jam

a. Vapor velocity ,Uv :


Uv = 0,07 x 0,15 ((L-v)/2.16)1/2
= 0,07 ((4015,9000 -1,8657)/2.16)1/2
= 0,4526 m/det
b. Vapor Volumetrik, Qv :
Qv = Laju alir uap/v
= 47595,7300 /(1,8657 x 3600)
= 1,7442 m3/det
c. Vessel Area, A :
A = Qv/Uv
= (1,7442 m3/det) / (0,4526 m/det)
= 3,8534 m2

376

d. Diameter Vessel , D:
D = (4A/)1/2

= [(4 x 3,8534 m2)/3,14]1/2


= 2,2155 m

e. Liquid volumetrik flow rate, q :


q

= Laju alir liq/L


= 47595,7300 / (4015,9000 x 3600)
= 0,0035 m3/det

f. Volume untuk 300 second Hold Up :


V = q x 300 second
= 0,0035 m3/det x 300 det
= 0,9876 m3
g. Volume elipsoidal head (Ve)
Ve = ( x D^3)/24
= (3,14 x 2,28923)/24
= 1,57 m3
h. Ketinggian liquid, L :
L = V/A = 0,9876 m3/ 3,8534 m2
= 1,42 m
Tinggi Head (ellipsoidal) = He

= D = 0,57 m

i. Tinggi Vessel, H:
H = D + L + He= (2,2155 + 1,42 + 0,55) m
= 3,03 m

j. Tebal dinding , t :

P x r
Cc
t = S.Ej - 0,6 P

(Peters, Tabel 4, Hal.537, Edisi 4)

Dimana :
P = 2,1 atm
r

= Jari-jari vessel

= 1,1077 m

377

S = Working stress allowable

= 932,2297 atm

Ej = Welding Join Efisiensi

= 0,85

Cc = Tebal korosi yang diizinkan = 0,003175 m

(Perrys hand book)

Maka :
t

2,1 atm x 1,1077 m


(932,2297 x 0,85) ( 0,6 x 2,1 atm)

0,0060 m

0,6047 cm

OD

0,003175 m

= D + 2t
= 2,2892 m + (2 x 0,0058 )
= 2,2276 m

k. Perhitungan Desain koil


Fluida Panas

Fluida Dingin

: Steam
W

= 5427,5148 kg/jam

= 11965,6073 lb/jam

T1

= 300.0000oC

= 572 oF

T2

= 300.0000oC

= 572 oF

: Aliran 36
W

= 59310,7822 kg/jam = 130757,7368 lb/jam

t1

= 97,0241 oC

= 206,64 oF

t2

= 187,3684 oC

= 369,26 oF

Perhitungan:
13.

Beban Panas FD-04


Q = 3271271,616 kJ/jam = 3100612,6474 Btu/jam

14.

LMTD
Fluida Panas
(oF)
572
572
0

Suhu tinggi
Suhu rendah
Selisih

Fluida Dingin
(oF)
369,3
206,6

Selisih
202,7
365,36
-162,62

378

t 2 t1
LMTD = ln ( t 2 / t1 ) = 224,0742oF
t = 273,3499 oF

15. Tc = T avg
tc = t avg

= 572 oF
= 287,95 oF

Asumsi UD = 250 Btu/hr.ft2.oF


250-500 (Tabel 8. Kern)
3100612,6474
A = 250 273,3499 = 44,9184 ft2

Karena A< 200 ft2, maka dipilih HE jenis Double Pipe Heat Exchanger.
Desain Koil Pemanas
1. Rasiopanjang coil terhadap diameter tangki, LC/ Dt = 0,65
2. Rasio diameter coil terhadap diameter tangki, DC/Dt = 0,70
3. Rasiotinggi coil daridasartangkiterhadap diameter tangki, HC/Dt = 0,15
4. Rasio diameter tube coil terhadap diameter pengaduk, Dct/Di = 0,088
5. Rasiojarakantara coil terhadap diameter tube coil, Sc/Dct = 2,00
1. Panjang coil

= 0,692 m

2. Diameter Coil = 0,745 m


3. Tinggi Coil

= 0,160 m

4. D Tube Coil

= 0,019 m

5. Jarak Coil

= 0,038 m

Data Pipa
IPS (in)
SN
OD (in)
ID (in)
a (ft2/ft)

Inner Pipe
22,000
20,000
22,000
21,35
5,747

379

l. Flow Area, ap
D = 21,350 in
ap

= 4 D2

= 1,7792 ft

= 4 ( 1,7792)2 = 2,4849 ft2

m. Kecepatan Massa, Gp

11965,6073
2,4849
Gp = w/ap =
= 4.815,3939 lb/hr ft2
n. Reynold number, Re
Pada Tavg = 572 oF

= 0,0203 lb/ft.hr

Rep

= D.Gp/
= 174826,82

o. JH

= 25

(Fig. 24, Kern)

Pada tavg = 572 oF


p. k = 0,0237 Btu/hr.ft2(oF/ft)
cp = 0,4790 Btu/lb.oF

q. hi

= 0,9968
k c

= JH De k

0,14

= 0,3320 Btu/hr.ft2.oF
r. Koreksi hi pada permukaan OD
hio = hi x ID/OD
= 0,3221Btu/hr.ft2.oF
s. Clean Overall Coefficient, UC
hioxho
UC = hio ho = 0,3112 Btu/hr.ft2.oF

380

t. Design Overall Coefficient, UD


1
1

Rd
UD UC

(Pers. 6.10)

Rd ditentukan 0,002 untuk masa service 1 tahun


1
1

0,002
U D 1,1299

UD = 0,3110 Btu/hr.ft2.oF
Q
u. U D . t Required Length
A=

= 64676,202 ft2

Dari tabel 11 Kern, untuk 22-in IPS standard pipe, external surface/foot
length = 5,7470 ft
Luas permukaan antar 1 putaran, jika diameter helix (Dh) adalah 3 ft
Ap = 54,13674 ft2
Jumlah putaran yang dibutuhkan

64676,202
= 54,13674 = 1194,6822

Panjang koil yang dibutuhkan

= 11253,9067 ft

Nama Alat

IDENTIFIKASI
Flash Disttiler

Kode Alat

FD 05

Jumlah

1 buah

Fungsi

Menguapkan sebagian umpan dari produk

381

Tipe
Kapasitas
Temperatur
Tekanan
ID

bottom EV-03
DATA DESIGN
Silinder vertikal dengan tutup elipsoidal
59310,782 m3
187,36 C
2,1 atm
2,2892 m

OD
Tinggi
Tebal
Bahan Konstruksi

2,3010 m
3,02 m
0,0060 m
Carbon Steel