Only change the blod writen parametres according to your travel curves. Others are
only for specific lift application default values.
L2-01=1 ; Sense power loses. But start again when line power is okey.
L3-04=0 ; Brake resistance is connected.
L5-01=3 ; Try 3 times to restart after fault before locking system.
L6-01=4 ; High torque sense enabled.
L6-02=%180 ; High torque detection level.
L6-03=2 ; High torque detection time.
D1-01=0
D1-02=0
D1-03=7 ; Slow speed V0 (Hz)
D1-04=15 ; Inspection speed V1 (Hz)
D1-05=50 ; Hıgh speed V2 (Hz)
D1-06=0
D1-07=25 ; Short travel speed Vs (Hz)
D1-08=0
D1-09=0
In vvvf systems for travel comfort, the acceleration of car is not too much. So
in some cases especially short travel distance lift may starts to decelerate before
reaching the full speed. In this condition lift may travel a long with a small speed
(V0). By setting minimum acceleration time; lift don’t stops to accelerate neither a
slow speed signal comes from control panel in this time. So it’s possible to travel short
distance with an optimum speed without an extra middle speed signalization from
control card. Adjust this parameter in the shortest way step by step. To big values may
cause a faulty long forced travels.