A2fm e
A2fm e
A2fm e
97
– Optimum efficiency
Hydraulic fluid
Mineral oil (no code)
HF-fluids sizes 10...200 (no code)
sizes 250...1000 (only in connection with drive shaft bearings "L") E-
Mode of operation
Motor (Plug-in motor A2FE see RE 91008) M
Size
Displacement Vg (cm3)
5 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Sizes 5...200: production plant Elchingen; Sizes 250...1000: production plant Horb
Series
6
Index
sizes 10...180 1
size 200 3
sizes 250...1000 0
Direction of rotation
viewed on shaft end alternating W
Shaft end 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Splined shaft — — — — — A
DIN 5480 — — — — — — — Z
Parallel shaft with — — — — — — B
key, DIN 6885 — — — — — — — P
= available
− = not available
= preferred program
(preferred types see page 22)
A2F M / 6 W -
Hydraulic fluid
Mode of operation
Size
Series
Index
Direction of rotation
Seals
Shaft end
Mounting flange
Service line connections 1 ) 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Ports A and B 01 0 — — — 010
SAE, at rear end 6 — — — — — — — — — — — — — 016
Ports A and B SAE 02 0 — — — — — — — — 020
at side, opposite side 6 — — — — — — — — — — — — — 026
7 — — — — — — — — — — — 027
Ports A and B 03 0 — — — — — — — — — — — — — — — 030
threads, at side, opposite side
6 — — — — — — — — — — — — — — — — — — 036
Ports A and B 04 0 — — — — — — — — — — — — 040
threads, at side and rear end 6 — — — — — — — — — — — — — — — 046
Ports A and B SAE 10 0 — — — — — — — — — — 100
at side, same side 6 — — — — — — — — — — — — — — 106
port plate with integrated 19 1 — — — — — — — — — — 191
pressure relief valves 2 — — — — — — — — — — 192
Valves
without valves (no code) 0
with pressure relief valves (without pressure sequence range) 1
with pressure relief valves (with pressure sequence range) 2
with integrated flushing valve 6
with built-on flushing and boost valve 7
Technical Data
Fluid Notes on the selection of the hydraulic fluid
We request that before starting a project detailed information about In order to select the correct fluid, it is necessary to know the
the choice of pressure fluids and application conditions are taken operating temperature in the loop (closed circuit) or the tank
from out catalogue sheets RE 90220 (mineral oil), RE 90221 temperature (open circuit) in relation to the ambient temperature.
(environmentally acceptable hydraulic fluids) and RE 90223 (fire The hydraulic fluid should be selected so that within the
resistance fluids, HF). operating temperature range, the operating viscosity lies within
When using HF- or environmentally acceptable hydraulic fluids the optimum range (ν opt) (see shaded section of the selection
possible limitations for the technical data have to be taken into diagram). We recommend that the highest possible viscosity
consideration. If necessary please consult our technical range should be chosen in each case.
department (please indicate type of the hydraulic fluid used for your Example: At an ambient temperature of X°C the operating
application on the order sheet). temperature (closed circuit: loop temperature; open circuit: tank
temperature) is 60°C. Within the operating viscosity range (ν opt;
Operating viscosity range shaded area), this corresponds to viscosity ranges VG 46 or VG
In order to optain optimum efficiency and service life, we 68. VG 68 should be selected.
recommend that the operating viscosity (at operating Important: The leakage oil (case drain oil) temperature is
temperature) be selected from within the range: influenced by pressure and motor speed and is always higher
νopt = operating viscosity 16...36 mm2/s than the circuit or tank temperature. However, at no point in the
circuit may the temperature exceed 115°C for sizes 5…200 or
referred to the loop temperature (closed circuit) or tank 90°C for sizes 250…1000.
temperature (open circuit). If it is not possible to comply with the above conditions because
of extreme operating parameters or high ambient temperatures
Viscosity limits please consult us.
The limiting values for viscosity are as follows:
sizes 5...200 Filtration
The finer the filtration the better the achieved purity grade of the
νmin = 5 mm2/s,
short term at a max. permissible temperature of tmax = 115°C pressure fluid and the longer the life of the axial piston unit.
To ensure the functioning of the axial piston unit a minimum
νmax = 1600 mm2/s, short term on cold start (tmin = -40°C)
purity grade of:
sizes 250…1000 9 to NAS 1638
νmin = 10 mm2/s 6 to SAE
short term at a max. permissible leakage oil temp. of tmax = 90°C 18/15 to ISO/DIS 4406 is necessary.
νmax = 1000 mm2/s,
At very high temperatures of the hydraulic fluid (90°C to max.
short term on cold start (tmin = -25°C)
115°C, not permissible for sizes 250…1000!) at least cleanless class
Please note that the max. fluid temperature is also not exceeded in 8 to NAS 1638
certain areas (for instance bearing area). 5 to SAE
17/14 to ISO/DIS 4406 is necessary.
At temperatures of -25°C up to -40°C special measures may be
required for certain installation positions. Please contact us for If above mentioned grades cannot be maintained please
further information. consult supplier.
V 32
V 46
V
G
G
G
10
22
Technical Data
Case drain pressure Flushing valve
The lower the speed and the case drain pressure the higher the In order to prevent excessive heat build-up in closed circuit
life expectation of the shaft seal ring. operation, it is possible to fit a flushing valve (built into the port
plate). Two such valves are available:
Shaft seal ring FPM (fluor-caoutchouc) - an Integrated flushing valve (built into the port plate) (sizes 23...90)
The values shown in the diagram are permissible loads of the - a built-on flushing and boost pressure relief valve (sizes 45...180, 250)
seal ring and shall not be exceeded.
Integrated flushing valve (6)
At stationary pressure loads in the range of the max. admissible
leakage pressure a reduction of the life experience of the seal - switching pressure ∆p ≥ 8 bar (this value is lower than the starting
pressure of an unloaded motor). T2 A (B)
ring will result.
For a short period (t < 5 min.) are for the sizes 10…200 pressure - closed in centre position (∆p < 8 bar).
loads up to 5 bar independent from rotational speeds are Sizes 23-32 45-63 80-90
permissible.
Flushing-
2,5 3,1 4,1
Sizes 10...200 volume L/min
10 (values given for low pressure
∆p = 25 bar) T1 B (A)
9
sizes 10,12,16 Built-on flushing and boost pressure relief valve (7)
8
perm. pressure pabs. max. (bar)
Technical Data
Working pressure range Speed sensor (D) (sizes 23...180)
Maximum pressure at port A or B Version A2FM…D ("suitable for fitting speed sensor") includes
(Pressure data to DIN 24312) gearing on the rotary group and in addition the port M in which
a speed sensor is screwed in.
Size 5 Shaft end B Shaft end C
A speed-proportional signal is produced by means of the
Nominal pressure pN 210 bar 315 bar rotating, splined rotary group which can be picked up by a
Peak pressure pmax 250 bar 350 bar suitable sensor and fed back for evaluation.
The speed sensor can be screwed into port M (thread M18x1,5).
Sizes 10...200 Shaft end A Shaft end Z, B, P
Sizes 23...32 45 56...63 80...90 107...125 160...180
Nominal pressure pN 400 bar 350 bar *) No. of teath 38 45 47 53 59 67
Peak pressure pmax 450 bar 400 bar
length of
*) Attention: shaft end Z and P with drives of radial force loads at 12,7 11,2 14,7 14,7 14,7 14,7
thread (mm)
the drive shaft (pinion V-belt drives) necessitate reduction of the The speed sensor is not included in standard supply.
nominal pressure to pN = 315 bar (please contact us).
Suitable sensors (order seperately):
- Induktive impulse detector ID (see RE 95038)
Sizes 250...1000 - Hall effect speed sensor HD (see RE 95042)
Nominal pressure pN 350 bar
Peak pressure pmax 400 bar
Table of values (theoretical values, without considering ηmh and ηv; values rounded)
Size 5 10 12 16 23 28 32 45 56 63 80
3
Displacement Vg cm 4,93 10,3 12 16 22,9 28,1 32 45,6 56,1 63 80,4
Max. speed nmax rpm 10 000 8000 8000 8000 6300 6300 6300 5600 5000 5000 4500
1
nmax intermittent ) rpm 11 000 8800 8800 8800 6900 6900 6900 6200 5500 5500 5000
Max. flow qV max L/min 49 82 96 128 144 176 201 255 280 315 360
Torque constants TK Nm/bar 0,076 0,164 0,19 0,25 0,36 0,445 0,509 0,725 0,89 1,0 1,27
Torque at ∆p = 350 bar T Nm 24,7 2) 57 67 88 126 156 178 254 312 350 445
∆p = 400 bar T Nm – 65 76 100 144 178 204 290 356 400 508
Case volume L 0,17 0,17 0,17 0,20 0,20 0,20 0,33 0,45 0,45 0,55
Moment of inertia
J kgm2 0,00008 0,0004 0,0004 0,0004 0,0012 0,0012 0,0012 0,0024 0,0042 0,0042 0,0072
about drive axis
Weight (approx) m kg 2,5 5,4 5,4 5,4 9,5 9,5 9,5 13,5 18 18 23
Size 90 107 125 160 180 200 250 355 500 710 1000
Displacement Vg cm3 90 106,7 125 160,4 180 200 250 355 500 710 1000
Max. speed nmax rpm 4500 4000 4000 3600 3600 2750 2500 2240 2000 1600 1600
1
nmax intermittent ) rpm 5000 4400 4400 4000 4000 3000 – – – – –
Max. flow qV max L/min 405 427 500 577 648 550 625 795 1000 1136 1600
Torque constants TK Nm/bar 1,43 1,70 1,99 2,54 2,86 3,18 3,98 5,64 7,95 11,3 15,9
Torque at ∆p = 350 bar T Nm 501 595 697 889 1001 1114 1391 1979 2785 3955 5570
∆p = 400 bar T Nm 572 680 796 1016 1144 1272 – – – – –
Case volume L 0,55 0,8 0,8 1,1 1,1 2,5 3,5 7,8
Moment of inertia
J kgm2 0,0072 0,0116 0,0116 0,0220 0,0220 0,0378 0,061 0,102 0,178 0,55 0,55
about drive axis
Weight (approx.) m kg 23 32 32 45 45 66 73 110 155 322 336
1
) Intermittent max. speed: overspeed at discharge and overtaking travel operations, t < 5 sec. and ∆p < 150 bar
2
) ∆p = 350 bar
Technical Data
Output drive
Permissible axial and radial loads on drive shaft
The values given are maximum values and do not apply to continuous operation
Size 5 10 12 16 23 28 32 45 56 63 80
a mm 12 16 16 16 16 16 16 18 18 18 20
Fq max N 710 2350 2750 3700 4300 5400 6100 8150 9200 10300 11500
±Fax max N 180 320 320 320 500 500 500 630 800 800 1000
±Fax perm. /bar N/bar 1,5 3,0 3,0 3,0 5,2 5,2 5,2 7,0 8,7 8,7 10,6
Size 90 107 125 160 180 200 250 355 500 710 1000
a mm 20 20 20 25 25 25 41 52,5 52,5 67,5 67,5
Fq max N 12900 13600 15900 18400 20600 22900 12001) 15001) 19001) 30001) 26001)
±Fax max N +Fax max 1000 1250 1250 1600 1600 1600 4000 5000 6250 10000 10000
- Fax max 1000 1250 1250 1600 1600 1600 1200 1500 1900 3000 2600
±Fax perm. /bar N/bar 10,6 12,9 12,9 16,7 16,7 16,7 2
) 2
) 2
) 2
) 2
)
1
) Axial piston unit in stationary or in bypass operation, please contact us when appearing higher forces!
2
) Please contact us!
Code explanation
a = distance of Fq from shaft shoulder The direction of the max. perm. axial force must be noted by
Fq max = max. perm. radial force at distance a sizes 5…200
(at intermittent operation) − Fax = increases bearing life
±Fax max = max. perm. axial force when stationary + Fax = reduces bearing life
or when axial piston unit is running at zero pressure (avoid if possible)
±F ax perm./bar = perm. axial force/bar operating pressure
qV • 1000 • ηv
Output speed n = in rpm
Vg ° ϕop
alternating = 45 t =4
5°
rotation ϕ opt
Vg • ∆p • ηmh
Output torque T =
20 • π 0° ϕo
=7 pt =7
1,59 • Vg • ∆p • ηmh ϕo
pt
0°
= in Nm
100
T = TK • ∆p • ηmh in Nm
2π•T•n T•n
Output power P = =
60 000 9549 A B A B
qV • ∆p
= • ηt in kW
600 anti-clockwise rotation clockwise rotation anti-clockwise rotation
pressure at port B pressure at port A pressure at port B
3
Vg = geometric displacement per rev. in cm
T = torque in Nm
∆p = pressure differential in bar
n = speed in rpm
TK = torque constants in Nm/bar
ηv = volumetric efficiency
ηmh = mech.-hyd. efficiency
ηt = overall efficiency
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
8
Y
70 Detail Y
74 R6
17, 58, ,5 T
5 5
A
ø60 h8
70
25° 0,1
±
6,4
75
ø48,5
62
4
T T
51 80
Connections B
A, B Service line ports M 18x1,5
T Drain port M 10x1, both sides
Shaft ends
33
24 22
ø12,8
M10x1
ø12k6
13,5
M4
10 ,4
R0
taper 1:10
Nominal pressure Nominal pressure
pN = 210 bar pN = 315 bar
Series
6.0
Shaft end
Parallel shaft with key DIN 6885 B
Tapered shaft with spigot and spring washer DIN 6888 C
= preferred program
Service line connections (preferred types see page 22)
Threads at side, metric 3
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
pla
,5
40
te
95
41
s
0
10
53,5
9
18,2
T2 5 A B
ø8
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 12x1,5
Shaft ends
Sizes 10, 12, 16 Sizes 10, 12 Sizes 10, 12, 16 Sizes 10, 12
A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 25x1,25x30x18x9g W 20x1,25x30x14x9g key AS 8x7x32 key AS 6x6x32
DIN 5480 DIN 5480 DIN 6885 DIN 6885
22
E1x0,2 E1x0,2
R1
16 DIN 509
R
DIN 509
,6
1,
2
ø25 k6
M 10
ø20 k6
M 10
ø24,6
ø21,6
ø19,6
ø16,6
22,5
M6
28
M6
6 12 22 2,5 16 2,5
28 34 40 40
Port plates
03 04
10
8 10
8 B1 A1
55,5
55,5
69,5
91
B A B A
91
130,5
130,5 85 147 36
166 166 85
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
45°
60,7 45 °
25 18
8
T1 118
se R 12
19 e
po
rt
pl
at
es
h6
40 °
118
,5
ø100
48
5
12
55,5
19
11
23,2
A B
06
T2
ø1
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 16x1,5
Shaft ends
Sizes 23, 28, 32 Sizes 23, 28 Sizes 23, 28, 32 Sizes 23, 28
A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 30x2x30x14x9g W 25x1,25x30x18x9g key AS 8x7x40 key AS 8x7x40
DIN 5480 DIN 5480 DIN 6885 DIN 6885
22
E1x0,2 E1x0,2
R1
19 DIN 509
R
DIN 509
,6
1,
6
ø30 k6
M 10
ø25 k6
M 10
ø24,6
ø24,6
ø29,6
ø21,6
M8
33
M8
28
8 15 22 19
35 43 50 50
60,7
2 M M 18 x 1,5
53
50
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
12 115 13
1 40,5 40,5 7
B A 18
,2
18,2
13 ,5
40
70
78
106
B A
117
M8; 15 deep M8; 15 deep
153 13
173 59 144
190 120
A, B Service line ports SAE 1/2" A, B Service line ports SAE 1/2"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series
03 04
13 13
7 7
B1 A1
88
70
70
117
B A B A
117
144 144
190 120 166 58
190 120
14 Detail Y
9
40
13
40,5
106
B
91
115
59
40,5
158
A
178 M8; 15 deep
18,2
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
32 20
T1 150
12
se R 16
18 e
po
rt
pla
te
ø125 h6
40 °
150
52
13,5
16
63
18
30
18
A B
ø1
T2
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 18x1,5
Shaft ends
28 28 E1x0,2
DIN 509
R1
R1
,6
,6
M 12
M 12
ø30 k6
ø29,6
ø26,6
ø24,6
M 12
33
8 8
28
35 35
60
prepared for speed sensing control (D), with port M with built-on flushing and boost valve (7)
(inductive impulse detector ID see RE 95038
hall effect speed sensor HD see RE 95042, 223
to be ordered separately!)
60,3
5,5 M M 18 x 1,5 Y
54,5
151
Detail Y A
B
98
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
147 15
13 5
8 50,8 50,8
B A 23
,8
19 8
,
50
80
23,8
89
B A
122
133
M 10; 17 deep M 10; 17 deep
166 19 155 128
194 75 207
A, B Service line ports SAE 3/4" A, B Service line ports SAE 3/4"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series
04 10
15 16 Detail Y
5 7 49
B1 A1
50,8
B
19
100
119
80
B A
102
133
147
75
50,8
A
155 58 169
179 128 193 23,8
207 M 10; 17 deep
Y
A, B, A1, B1 Service line ports M 33x2 A, B Service line ports SAE 3/4"
420 bar (6000 psi) high pressure series
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
40 °
150
56
13,5
16
70
18
30
A B
28
ø1
T2
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 18x1,5
Shaft ends
28 28 E1x0,2 E1x0,2
R1 DIN 509
,6 DIN 509
R1
,6
M 12
M 12
ø30 k6
ø34,6
ø35 k6
ø24,6
ø29,6
M 12
ø29,6
M 12
38
33
8 8
28 2,5 28 2,5
40 35
60 60
prepared for speed sensing control (D), with port M with built-on flushing and boost valve (7)
(inductive impulse detector ID see RE 95038
239
hall effect speed sensor HD see RE 95042,
to be ordered separately!)
Y
67,5
6 M M 18 x 1,5
159
60
Detail Y
A
98
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
14 147 16
9, 6,
5 50,8 50,8 5
B A 23
,8
19 ,8
50
96
87
23,8
130
B A
142
M 10; 17 deep M 10; 17 deep
182 19 171
206 75 225 136
A, B Service line ports SAE 3/4" A, B Service line ports SAE 3/4"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series
04 10
17 Detail Y
16 6
6, 49
5
B1 A1
50,8
B
19
107
87
107
147
142
75
B A
130
50,8
A
171 182
195 58 206 23,8
M 10; 17 deep
225 136
A, B, A1, B1 Service line ports M 33x2 A, B Service line ports SAE 3/4"
420 bar (6000 psi) high pressure series
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
165
61
13,5
18
83
15
29
38
T2 A B
ø1
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 18x1,5
Shaft ends
36 28 E1x0,2
R
E1x0,2
1, DIN 509 DIN 509
R2
6
,5
ø40 k6
M 16
M 12
ø35 k6
M 12
M 16
ø34,6
ø39,6
ø34,6
ø29,6
43
38
8 8 28 2,5
40 36 2,5
45 70
70
prepared for speed sensing control (D), with port M with built-on flushing and boost valve (7)
(inductive impulse detector ID see RE 95038
hall effect speed sensor HD see RE 95042, 268
to be ordered separately!)
78,5
M M 18 x 1,5
6 Y
65,8
173,5
Detail Y A
98
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
16 18
2, 166 9,
5 5
57,2 57,2
B A 27
,8
,2
104,5
57
99
25
27,8
145
B A
162
M 12; 17 deep
203 M 12; 17 deep
25 160
233 196
84
257
A, B Service line ports SAE 1" A, B Service line ports SAE 1"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series
10
19
8 Detail Y
60
57,2
B
25
145
166
84
121
57,2
A
206
27,8
236 M 12; 17 deep
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
Unit Dimensions, Sizes 107, 125 Dimensions brackets for size 107
45 °
45 °
82,8
40 23 190
T1
10
R 20
se
18 e
po
rt
pl
at
ø160 h6
40 °
es
190
67
17,5
20
85
18
36,5
A B
5 0
T2
ø1
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 18x1,5
Shaft ends
Sizes 107, 125 Size 107 Sizes 107, 125 Size 107
A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 45x2x30x21x9g W 40x2x30x18x9g key AS 14x9x63 key AS 12x8x63
DIN 5480 DIN 5480 DIN 6885 DIN 6885
36 28 E1x0,2 E1x0,2
R2 DIN 509
,5 DIN 509
R2
,5
ø40 k6
ø45 k6
M 16
ø44,6
ø34,6
M 12
ø39,6
M 12
ø39,6
M 16
48,5
43
8 8
36 2,5 28 2,5
50 45
80 80
prepared for speed sensing control (D), with port M with built-on flushing and boost valve (7)
(inductive impulse detector ID see RE 95038
hall effect speed sensor HD see RE 95042, 294
to be ordered separately!)
82,8 M M 18 x 1,5
8 Y
75
192
Detail Y A
98
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
Sizes 107, 125 Port plates Dimensions brackets for size 107
01 02
18 194
6,
5 66,7 66,7 22
2
B A 31
,8
(2
(2 ,2)
7,
120
32 (57
8)
31,8
5)
,7
159
66
110
B A
M 14; 19 deep
181
225,5 32
252 99 M14; 19 deep
(M12; 17 deep) 178
213
285
A, B Service line ports SAE 11/4" A, B Service line ports SAE 11/4"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series (SAE 1")
10
22 Detail Y
4
70
66,7
B
32
136
157
194
99
66.7
A
226
261
M 14; 19 deep
31,8
Y
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
40°
210
es
,5
77
17,5
22
95,5
19,5
37,2
A B
80
T2
ø1
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 22x1,5
Shaft ends
Sizes 160, 180 Size 160 Sizes 160, 180 Size 160
A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 50x2x30x24x9g W 45x2x30x21x9g key AS 14x9x70 key AS 14x9x70
DIN 5480 DIN 5480 DIN 6885 DIN 6885
36 36
R2
R2
R4
,5
R2
,5
,5
ø50 k6
M 16
ø45 k6
M 16
ø39,6
ø44,6
48,5
M 16
M 16
53,5
11 8 36
36
55 50
90 90
93 M M 18 x 1,5 Y
2
83
201
Detail Y A
98
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
20 194 23
8 3
66,7 66,7
B A 31
,8
,7
66
121
32
134
31,8
B A
188
188
M 14; 19 deep M 14; 19 deep
252 32 237 202
294 99
294
A, B Service line ports SAE 11/4" A, B Service line ports SAE 11/4"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series
10
24 Detail Y
4
70
66,7
32
B
185
194
99
149
66,7
A
252
290 M 14; 19 deep 31,8
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
22
W 50x2x30x24x9g R4
DIN 5480
ø200 -0,029
25°
M 16
92
ø44,6
236
0
25
102,5
84
15
211
165
55
32 T A B
284 B Parallel shaft with
309 204 key AS 14x9x70
66,7 66,7
R2
DIN 6885
B A
,5
ø50 k6
M 16
53,5
Connections
31,8
A, B Service line ports SAE 11/4"
36 11
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 22x1,5 90
32 M 14;
99 deep
19 tief
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
124
31,8
105
22
ø224 h8
210
246
0´ 0
105
28
26°3
93
M14; 19 deep
25 172 32 32
T X 50 50
82
314
B A
210
0´
105
26°3
82
172
32
7
66,
T
X
323 344
Connections
A, B Service line ports SAE 11/4"
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 22x1,5
U Port for bearing flushing (plugged) M14x1,5
Shaft ends
Z Splined shaft P Parallel shaft with
W 50x2x30x24x9g key AS 14x9x80
DIN 5480 DIN 6885
36
R1
R2
,5
,6
ø50 k6
M 16
M 16
53,5
ø45
9 36
58
82
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
320 22°30´
50 83
14 23,5 ° 335
45
U T
170
36
128
0
ø280 h8
18
0´
26°3
102
0
32
335
128
198
28 T X
83
350 Detail X
36,6 36,6
B A
245
79,4
Connections
A, B Service line ports SAE 11/2"
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 33x2
U Port for bearing flushing (plugged) M 14x1,5 M16; 21 deep
40 40
60 60
Shaft ends
Z Splined shaft P Parallel shaft with
W 60x2x30x28x9g key AS 18x11x100
DIN 5480 DIN 6885
42
R1
R4
,6
ø60 m6
M 20
M 20
64,4
ø55
11 42
82
105
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
361,5 22°30´
50 98
°
14 27,5 45 375
U T
192
142 40
0
22
ø315 h8
375
0´
112,5
26°3
0
36
142
220 X
30 T
111
396 Detail X 36,6 36,6
B A
270
79,4
Connections
A, B Service line ports SAE 11/2"
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 33x2
U Port for bearing flushing (plugged) M 18x1,5 M16; 21 deep
40 40
65 65
Shaft ends
Z Splined shaft P Parallel shaft with
W 70x3x30x22x9g key AS 20x12x100
DIN 5480 DIN 6885
42
R1
R4
6,
ø70 m6
ø62,7
M 20
M 20
74,5
74,4
13 42
80
105
Nominal pressure Nominal pressure
pN = 350 bar pN = 350 bar
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
486 22°30´
50 131
14 41,5 465
°
45
U T
236
50
183
465
22
ø400 h8
´
18°30
102
0
45
183
252 X
35 T
156
507 Detail X 44,5 44,5
B A
340
96,8
Connections
A, B Service line ports SAE 2"
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 42x2
U Port for bearing flushing (plugged) M18x1,5 M20; 30 deep
50 50
85 85
Shaft ends
Z Splined shaft P Parallel shaft with
W 90x3x30x28x9g key AS 25x14x125
DIN 5480 DIN 6885
50
R1
R4
,6
ø90 m6
M 24
ø82,6
M 24
95
14 50
105
130
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
22°30´
468
50 131
° 465
14 41,5 45
U T
236
50
183
0
22
ø400 h8
465
0´
143
26°3
0
45
183
279 X
35 156 T
512
Detail X
44,5 44,5
Connections
340
96,8
A, B Service line ports SAE 2" B A
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 42x2
U Port for bearing flushing (plugged) M18x1,5
M20; 30 deep
50 50
85 85
Shaft ends
Z Splined shaft P Parallel shaft with
W 90x3x30x28x9g key AS 25x14x125
DIN 5480 DIN 6885
50
R1
R4
6,
ø90 m6
M 24
ø82,6
M 24
95
14 50
105
130
Nominal pressure Nominal pressure
pN = 350 bar pN = 350 bar
Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.
D3
T1
D4
MA MA MB
MB
pSt pSt
D7
Z
D6
T2
A S1 B A S1 B
Detail Y MB S1 MB S1
D10
Y Y
D12
B Detail Z
Pressure relief
Pressure relief valves
D8 valves - without pressure sequence range (1) - with pressure sequence range (2)
MHDBN16 (Sizes 28...45) MHDBB16 (Sizes 28...45)
D11
S1 Connections
A, B Service line ports SAE, 420 bar
A MB MA
(6000 psi high pressure series)
D13
S1 Boosting
pSt Pilot pressure port G 1/4
MA, MB Test ports (plugged)
Brueninghaus Hydromatik GmbH, Plant Elchingen, Glockeraustraße 2, D–89275 Elchingen, Tel. (07308) 820, Telefax (07308) 7274
Plant Horb, An den Kelterwiesen 14, D–72160 Horb, Tel. (07451) 920, Telefax (07451) 8221
28/28 Brueninghaus Hydromatik The specified data is for product description purposes only and may not be deemed to be
guaranteed unless expressly confirmed in the contract. All rights reserved – Subject to revision