GMK 5220 Manual
GMK 5220 Manual
GMK 5220 Manual
!
?
****
For the normal emergency mode to work the following conditions must be met:
• Locking status signals for the boom section and cylinder must be valid
• Telescope cylinder solenoids must be without error
• At least one too low/too high proximity switch must be active & without errors on
other telescope cylinder proximity switches
• ECOS or EKS5 length measurement must be functional
Caution! should normal emergency mode not function it will be necessary to use
extended emergency mode. When using extended emergency mode extreme caution
should be used to verify the section/cylinder locking status and cylinder position.
Failure to observe the caution can lead to damage to the telescope system!
1. You must have a valid Dongle with installed Peak driver connected to the laptop.
7450
3. Press F5 on the ECOS in-cab display, while in the telescope window then press C,
two code numbers will be displayed e.g. 3585 0001
F1 F5
F2 F6
?
F3 F7
ECOS +00002 mm
F4
EKS5 +00000 mm
EKS4
F8
3585
? 0001
263s
?
! 360s
0000 0000 0000 0000 !
A ?
F9 F10 F11 F12 F13 F14
B P1 ESC
C Enter
4. Enter keycode 3585 in code field on laptop and press calculate. The calculated
number e.g. 23 must then be entered on the ECOS display by turning THE
POTENTIOMETER (P1) to match exactly and then press enter. The icon will then
change to tools to indicate access.
Note:
NOTE:
Ensure that the % / intermediate positions of telescope sections viewed in the
ECOS screen matches the exact configuration of the boom.
4. Press Enter and look for a cursor to appear in the section box. Press
buttons ABAC to accept the configuration.
?
!
****
5. Verify that the red ? has disappeared from the white tele box. The telescope
status has been successfully reset.
Should the red ? remain and the EKS 5 boom length display flashes you must re-
check and re-enter the boom configuration status.