Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

For More Information Please Call 1-800-Belden1: Description

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Detailed Specifications & Technical Data

ENGLISH MEASUREMENT VERSION

3112A Multi-Conductor - Thermocouple Extension Cable

For more Information


please call

1-800-Belden1

Description:
20 AWG pairs solid conductors, PVC insulation, overall Beldfoil® shield (100% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1 20 Solid Chromel & Alumel

Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PVC - Polyvinyl Chloride .016

Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100

Outer Shield Drain Wire AWG:


AWG Stranding Drain Wire Conductor Material
22 7x28 TC - Tinned Copper

Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride

Outer Jacket Ripcord: Yes

Overall Cabling
Overall Nominal Diameter: 0.206 in.

Pair
Pair Color Code Chart:
Number Color
1 Yellow & Red

Pair Lay Length & Direction:


Lay Length (in.) Twists/ft. (twist/ft)
2.000 6.000

Mechanical Characteristics (Overall)


Operating Temperature Range: -30°C To +105°C

Non-UL Temperature Rating: 105°C

Bulk Cable Weight: 26 lbs/1000 ft.

Max. Recommended Pulling Tension: 40 lbs.

Min. Bend Radius (Install)/Minor Axis: 2.100 in.

Page 1 of 3 08-06-2010
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION

3112A Multi-Conductor - Thermocouple Extension Cable

Applicable Specifications and Agency Compliance (Overall)


Applicable Standards & Environmental Programs
CEC/C(UL) Specification: CMG

CSA Specification: FT4

IEEE Specification: 1202

EU CE Mark: Yes

EU Directive 2000/53/EC (ELV): Yes

EU Directive 2002/95/EC (RoHS): Yes

EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005

EU Directive 2002/96/EC (WEEE): Yes

EU Directive 2003/11/EC (BFR): Yes

CA Prop 65 (CJ for Wire & Cable): Yes

MII Order #39 (China RoHS): Yes

ANSI Specification: MC 96.1-1982 Type KX

Flame Test
UL Flame Test: UL1685 FT4 Loading

Plenum/Non-Plenum
Plenum (Y/N): No

Surface Printing (Overall)


Electrical Characteristics (Overall)
Nom. Conductor DC Resistance:
Description DCR @ 20°C (Ohm/1000 ft)
CHROMEL 400.4
ALUMEL 161.1

Nominal Outer Shield DC Resistance:


DCR @ 20°C (Ohm/1000 ft)
10.6

Notes (Overall)
Notes: Chromel & Alumel = "Chromel and Alumel are Hoskins Manufacturing Company trademarks."

Put Ups and Colors:


Item # Putup Ship Weight Color Notes Item Desc
3112A 0041000 1,000 FT 26.000 LB YELLOW C 1 FS PR #20 PVC KX
3112A 0045000 5,000 FT 135.000 LB YELLOW CZ 1 FS PR #20 PVC KX

Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.

Revision Number: 2 Revision Date: 03-25-2010

© 2010 Belden, Inc


All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.

Page 2 of 3 08-06-2010
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION

3112A Multi-Conductor - Thermocouple Extension Cable

All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.

Page 3 of 3 08-06-2010