Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

BELDEN 4C Shielded 5202FE

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Detailed Specifications & Technical Data

METRIC MEASUREMENT VERSION

5202FE Multi-Conductor - Commercial Applications

For more Information


please call

1-800-Belden1

General Description:
Security & Alarm Cable, Riser-CMR, 4-16 AWG stranded bare copper conductors with polyolefin
insulation, Beldfoil® shield and PVC jacket
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
4 16 19x29 BC - Bare Copper

Total Number of Conductors: 4

Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PP - Polypropylene 0.203

Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100

Outer Shield Drain Wire AWG:


AWG Stranding Drain Wire Conductor Material
24 (7x32) TC - Tinned Copper

Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.432

Outer Jacket Ripcord: Yes

Overall Cable
Overall Cabling Lay Length & Direction:
Length (mm) Direction Twists (twist/m)
76.200 Left Hand 13.124

Overall Cabling Color Code Chart:


Color
Black
Red
White
Green

Overall Nominal Diameter: 5.436 mm

Mechanical Characteristics (Overall)


Operating Temperature Range: -20°C To +75°C

UL Temperature Rating: 75°C

Bulk Cable Weight: 65.481 Kg/Km

Max. Recommended Pulling Tension: 650.772 N

Page 1 of 3 11-08-2019
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION

5202FE Multi-Conductor - Commercial Applications

Max. Recommended Pulling Tension: 650.772 N

Min. Bend Radius/Minor Axis: 53.975 mm

Applicable Specifications and Agency Compliance (Overall)


Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMR

NEC Articles: 800

CEC/C(UL) Specification: CMG

EU Directive 2011/65/EU (ROHS II): Yes

EU CE Mark: Yes

EU Directive 2000/53/EC (ELV): Yes

EU Directive 2002/95/EC (RoHS): Yes

EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005

EU Directive 2002/96/EC (WEEE): Yes

EU Directive 2003/11/EC (BFR): Yes

CA Prop 65 (CJ for Wire & Cable): Yes

MII Order #39 (China RoHS): Yes

Flame Test
UL Flame Test: UL1666 Vertical Shaft

CSA Flame Test: FT4

Suitability
Suitability - Indoor: Yes

Plenum/Non-Plenum
Plenum (Y/N): No

Plenum Number: 6202FE

Surface Printing (Overall)


Surface Printing: NEW GENERATION(R) BY BELDEN 5202FE CMR 75C 4C16 SHIELDED (UL)
E108998 OR C(UL) CMG----FT4 (2 FT., 7 DIGIT SEQUENTIAL) FEET

Electrical Characteristics (Overall)


Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
100.071

Nom. Capacitance Cond. to Other Conductor & Shield:


Capacitance (pF/m)
180.455

Nom. Conductor DC Resistance:


DCR @ 20°C (Ohm/km)
13.124

Nominal Outer Shield DC Resistance:


DCR @ 20°C (Ohm/km)
47.246

Max. Operating Voltage - UL:


Voltage
300 V RMS

Max. Recommended Current:


Description Current
10C Temperature Rise 5 Amps per conductor @ 25°C ambient

Page 2 of 3 11-08-2019
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION

5202FE Multi-Conductor - Commercial Applications

Put Ups and Colors:


Item # Putup Ship Weight Color Notes Item Desc
5202FE 008Z1000 1,000 FT 48.000 LB GRAY 4 #16 PP FS FRPVC
5202FE 0081000 1,000 FT 46.000 LB GRAY C 4 #16 PP FS FRPVC
5202FE 008500 500 FT 23.500 LB GRAY 4 #16 PP FS FRPVC

Notes:
C = CRATE REEL PUT-UP.

Revision Number: 3 Revision Date: 01-20-2015

© 2019 Belden, Inc


All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.

All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).

Page 3 of 3 11-08-2019

You might also like