For More Information Please Call 1-800-Belden1: 5341FE Multi-Conductor - Commercial Applications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Detailed Specifications & Technical Data

METRIC MEASUREMENT VERSION

5341FE Multi-Conductor - Commercial Applications

For more Information


please call

1-800-Belden1

General Description:
Security & Alarm Cable, Riser-CMR, 2-18 AWG stranded bare copper pairs with polyolefin insulation,
Beldfoil shield and PVC jacket with ripcord
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
2 18 7x26 BC - Bare Copper

Total Number of Conductors: 4

Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PP - Polypropylene 0.178

Outer Shield
Outer Shield Material:
Outer Shield Trade Name Outer Shield Material
Beldfoil Aluminum Foil-Polyester Tape

Outer Shield Drain Wire AWG:


AWG Stranding Drain Wire Conductor Material
24 Solid TC - Tinned Copper

Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.432

Overall Cable
Overall Nominal Diameter: 6.350 mm

Pair
Pair Color Code Chart:
Number Color
1 Black & Red
2 Black & White

Mechanical Characteristics (Overall)


Operating Temperature Range: -20C To +70C

Bulk Cable Weight: 49.111 Kg/Km

Max. Recommended Pulling Tension: 460.834 N

Min. Bend Radius/Minor Axis: 63.500 mm

Applicable Specifications and Agency Compliance (Overall)


Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMR

CEC/C(UL) Specification: CMG

EU Directive 2011/65/EU (ROHS II): Yes

EU CE Mark: Yes

EU Directive 2000/53/EC (ELV): Yes

EU Directive 2002/95/EC (RoHS): Yes

EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005

EU Directive 2002/96/EC (WEEE): Yes

Page 1 of 2 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION

5341FE Multi-Conductor - Commercial Applications

EU Directive 2003/11/EC (BFR): Yes

CA Prop 65 (CJ for Wire & Cable): Yes

MII Order #39 (China RoHS): Yes

Flame Test
UL Flame Test: UL1666 Vertical Shaft

CSA Flame Test: FT4

Plenum/Non-Plenum
Plenum (Y/N): No

Surface Printing (Overall)


Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
95.149

Nom. Capacitance Cond. to Other Conductor & Shield:


Capacitance (pF/m)
171.432

Nom. Conductor DC Resistance:


DCR @ 20C (Ohm/km)
21.4905

Nominal Outer Shield DC Resistance:


DCR @ 20C (Ohm/km)
42.981

Max. Operating Voltage - UL:


Voltage
300 V RMS

Max. Recommended Current:


Description Current
10C Temperature Rise 4 Amps per conductor @ 25C ambient

Put Ups and Colors:

Item # Putup Ship Weight Color Notes Item Desc


5341FE 008U1000 1,000 FT 35.000 LB GRAY 2 PR #18 PP FS FRPVC
5341FE 0081000 1,000 FT 36.000 LB GRAY C 2 PR #18 PP FS FRPVC
5341FE 008500 500 FT 21.000 LB GRAY C 2 PR #18 PP FS FRPVC

Notes:
C = CRATE REEL PUT-UP.

Revision Number: 3 Revision Date: 08-20-2013

2015 Belden, Inc


All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributors inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Beldens knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.

Page 2 of 2 01-09-2015