Instructions and Advices To Use The Electronic Controller Logik 8
Instructions and Advices To Use The Electronic Controller Logik 8
Instructions and Advices To Use The Electronic Controller Logik 8
CAUTIONS Page 3
MOUNTING Page 5
- Industrial control equipment for the operation and management of screw compressors only; don’t mount and use in
explosive room.
- In accordance to CE regulation:
Low tension: 2006/95/CE
Safety: EN 60730-1 (General regulations)
EMC 2004/108/CE
- In accordance to UL 508 (FILE #: E316817).
- Inputs and outputs via terminal-block board to wires (300V, 15A, 18-14AWG).
- Black-grey auto-extinguishing box in ABS:
a) according CE:
IP64 for the front panel and IP20 for the other parts;
b) according UL:
Type 1 and Type 12 for front panel mounting, installation in pollution degree 2 for the other parts.
- Tightening torque: 7 Nm.
- Working temperature: -25°C (-13°F) ÷ 50°C (122°F), 90% RH (non condensing).
- Storage temperature: -30°C (-22°F) ÷ 70°C (158°F).
- Power supply: 12 Vac ± 10% - 50÷60 Hz (power of transformer’s secondary: ~ 6 VA) from safety transformer.
- Max. current absorbed: ~ 220 mA.
- Visualization through:
nr. 3 green display with 7 segments.
nr. 3 green led.
- nr. 1 input for pressure transducer settable via software into input for electromechanical pressure switch.
- nr. 1 input for temperature probe to detect air end temperature.
- nr. 3 key buttons: Start – Stop – Function (visualization of temperature, working hours, maintenance timer and
reset).
- nr 3 opto isolated digital inputs for detection:
IN 1 = emergency stop button
IN 2 = OR alarm (thermal motor – thermal fan…….)
IN 3 = control phase relay or remote start/stop
- nr. 5 outputs via relay with contact 1.5A max. (general use):
RL1 = line contactor
RL2 = star contactor
RL3 = delta contactor
RL4 = load solenoid valve
RL5 = settable into alarm or fan contactor
MAX. RATED CURRENT WITH ALL RELAYS CLOSED: 4.5A
- Non volatile memory to store setting data, compressor status and working hours.
- The controller switches OFF due micro interruption of power longer than ~ 300 m.s..
Accessories:
- nr. 1 temperature probe KTY 13.5 with black cable TPE, length 2.5 m, working range –10°C÷130°C, resolution 1°C,
precision ± 1°C, to detect air end temperature.
- nr. 1 pressure transducer 4-20 mA for working pressure control: 2 wires, AISI 316L stainless steel membrane,
working range 0 ÷ 15 bar, resolution 0,1bar, precision ± 0,1bar.
166,2 mm
LOGIK 8
M1 M2 M3
1 2 3 4 5 6 1 2 3 4 1 2 3 4 5 6
- +
RL1
RL2
RL3
RL4
RL5
IN 1
IN 2
IN 3
COMMON
PRESSURE
12 VacTEMPERATURE
PROBE TRANSDUCER
N L L L
12-24 Vac L N
24-230 Vac
NOTES ON THE CONNECTIONS
Respect the working technical features and instructions on the electrical wiring; in special way both the
cables of the temperatures probes and pressure transducers must be isolated from the power cables and
proper RC filters must be placed on the contactors’ coils.
Besides pay attention low voltage and high voltage cables run on separate trunks.
- On the back side of the controller there must be enough space for wiring and connectors.
- The rear side of the controller must be protected against condensation, oil and dust.
- Don’t wash the front panel by water injection; clean the front panel with a soft cloth using soap water.
Terminal M1
Pole 1-2 = power supply 12 Vac ± 10% 50÷60 Hz
Poles 3-4 = temperature probe
Poles 5-6 = pressure transducer (pole 5 = – negative / pole 6 = + positive) or free contact of the electromechanical
pressure switch
Terminal M2
Pole 1 = neutral 0 Vac
Pole 2 = Input IN 1 – pulsante di emergenza (L)
Pole 3 = Input IN 2 – OR alarms: thermal motor, thermal fan, emergency stop button etc.. (L)
Pole 4 = Input IN 3 – control phase relay (L)
Terminal M3
Pole 1 = common relay 24-230 Vac
Pole 2 = output relay RL1 – line contactor
Pole 3 = output relay RL2 – star contactor
Pole 4 = output relay RL3 – delta contactor
Pole 5 = output relay RL4 – load solenoid valve
Pole 6 = output relay RL5 – alarm or fan contactor
Contactors 24 Vac
If the operation of the contactors and I°
soenoid valves come through 24 Vac, II°
the digital inputs have to be connected
to 24 Vac (see drawing on the right);
on this way when the pressure switch 12 – 0
opens due to high pressure, 24 Vac
lacks and deenergize all the contactors, Power supply to
solenoid valve and digital: the controller the controller
detects all the digital inputs opened and Security pressure
signal the alarm “AL9”. switch for high
pressure detection
I Start
F Stop
0
R
WORKING PRINCIPLE
1) Supplying power to the compressor, the display visualizes the message OFF.
2) In OFF status, the compressor starts by pushing the button I and the display visualizes the working pressure or
working temperature (according the setting of the parameter P01 = pressure control via pressure transducer or
electromechanical pressure switch)
3) The compressor stops by pushing the button 0 .
4) In case of alarm detected, the display visualizes the pertinent alarm code.
When the compressor is OFF by pushing at the same time F and 0 for 3 seconds enter into the setting of the
parameters and the display visualizes the code of the parameter; pushing the button F the display visualizes the
set value and by I and/or 0 change the value; pushing F again, visualize the code of the parameter and by the
buttons I and/or 0 flow up/down the codes of the next parameters; to enable the setting of the parameters,
always push the button F as explained above.
Quit the setting by pushing the button F for 3 seconds e comes back to OFF.
During the setting, if the value to set is equal to the higher or lower value of the settable range, the value visualized
starts blinking on the display.
ANTIPANIC FUNCTION
For safety reasons, during the setting if no one button is pushed for 60 seconds from the last pushing of any button,
the controller quit the setting automatically saving the values changed.
1) In case of setting parameter P01 = 1, the parameters P02 ÷ P06 will not be visualized.
2) Selecting the parameter P24= 0, if the power supply to the controller goes down 9.0 Vac, the controller
switches off and restart automatically (with a delay time set on parameter P17) when the power overcomes 10.5
Vac: the display doesn’t visualize any alarm for low voltage.
Selecting the parameter P24 = 1, if the power supply to the controller goes down 9.0 Vac, the controller
switches off; when the power overcomes 10.5 Vac, the controller visualizes the alarm code AL7 standing in OFF
status.
3) P25 = 0 input IN3 enabled as control phase relay and joined to related alarms wrong/missing phase.
P25 = 1 input IN3 enabled as remote start/stop (control phase relay disabled).
4) Selecting the parameter P28 = 0, RL5 operates as alarm relay and the parameters P29 and P30 are not visualized.
Selecting the parameter P28 = 1, RL5 operates the fan contactor and the parameters P29 and P30 are visualized.
5) The counting of the parameters P18 ÷ P22 is pertinent to ON time of RL1 and comes to backwards: when the
counting reaches 0, goes on as negative counting.
The storage of the hours comes every 15 minutes; if power lacks during this time, the split of 15 minutes time is
missed.
6) If the parameter P22 is set 9.900 will not generate the pertinent alarm
7) The parameter P23 is the max. starts per hour allowed to the motor (see alarm code AL8). If you set it “0” the
starts/hour control is not operated.
8) The parameter P26 allows to detect and visualize the pressure in two different scales:
0 = bar – 1 = PSI.
9) The parameter P27 allows to detect and visualize the temperature in two different scales:
0 = °C (Celsius) – °F (Fahrenheit)
*P31 = Security is related to the timer CAF (change air filter): once CAF timer is over, the compressor shut-off and the
display visualizes the alarm code A13.
ALARM CODES
MAINTENANCE MESSAGES
It’s possible to reset the shut off alarms by pushing the button F only when the compressor is OFF.
It’s possible to reset the warnings (visual alarms) and maintenance messages by pushing the button F even if the
compressor is in operation.
NOTES:
1) The shut off alarms have priority on the warnings (visual alarms) while the warnings have priority on the
maintenance messages.
2) If a maintenance message is visualized and then reset by the button F but the pertinent timer is not reset, the
next power on this maintenance message will be visualized on the display again.
3) The alarm codes and maintenance codes are visualized in every compressor status.
In case of parameter P01 = 1 (electromechanical pressure switch) the temperature is visualized on the display
directly, during the operation.
In case of parameter P01 = 0 (pressure transducer), when the compressor is ON, to visualize the temperature, push
easily the button F ; after 5 seconds the temperature is visualized, the display shifts back to visualize the working
pressure again.
NOTE:
1) if within 60 seconds the button F is not pushed, the controllers shifts back to the main visualization.
2) if the timer is negative, the first digit on the display visualizes the symbol “–“ while the other digits the hours;
in case of hours more than 99 the pertinent led of multiplicative factors is lighted
NOTE:
if within 60 seconds the button F is not pushed, the controller shifts back to the main visualization.
1) Power on:
a) the display visualizes the message OFF;
b) all the relays are OFF (de-energized).
2) Compressor ON by pushing I : the display visualizes the temperature and led indicates the status of RL4
(load solenoid valve).
24 (twenty-four) months from the production date printed on the label of the serial number.
Both working and technical features of the controller must be fully respected: the warranty declines if the
controller has been tampered or repaired by unauthorized personnel.
Operation or modification different from the original, wrong electrical wiring or bad assembling can be
cause of failures or malfunctioning of the controller; in these cases both warranty and own technical
features of the controller declines.
Technical features, drawings and any other document in this manual are property of Logika Control that
forbid any reproduction, even partial, of text and illustrations.
On its unquestionable judgement, Logika Control reserves the authority to modify the product to improve
operation and performance, besides to the right to withdraw the product from the production, in any time
and without notice.
REVISION INDEX
Revision 0 = Issue
Revision 0.1 = Issue for UL certification
Revision 0.2 = Modification on parameter P25: IN3 configuration as control phase relay or remote start/stop resulting
in slippage of the following codes; upgrade of software release in menu “Working hours” and top range starts/hour
from 20 to 60.
Revision 0.3 = Addition parameters: P26 and P27 respectively as selection pressure bar/PSI and temperature scale
°C (Celsius)/°F (Fahrenheit) – firmware release 0.16
Revision 0.4 = Addition parameter P31 Security – release firmware 0.19
Revision 0.5 = Revision edit of parameters