PRODUCT INFORMATION

NSGAFÖU 1.8/3 kV

Flexible single-conductor rubber cable with 1.8/3 kV nominal voltage

NSGAFÖU 1.8/3 kV AC, VDE-certified, power cable, single core rubber cable with outer coating, class 5, oil-resistant

Info
Public transport
Control cabinet internal wiring

Oil-resistant

Benefits
Arrangements made of single core cables NSGAFÖU in accordance with VDE 0250 part 602 with nominal voltage of at least
U0/U: 1.8/3 kV can be used for short circuit-proof and short-to-ground-proof installation up to 1000 V in accordance with VDE
0100 part 520 and VDE 0298 part 3

Application range
Wiring machines, devices, and control cabinets
Railway vehicles, buses;
short-circuit-proof up to 1000 V in switching stations and distributors
No direct burial, except through fire separations such as sand cups
In ducts and closed installation channels
Bundled or for connection of movable parts

Product features
The outer diameters stated in the article table are maximum values
Flame-retardant according to IEC 60332-1-2
Oil-resistant according to EN 60811-404
Normative nominal voltage classes U0/U 0.6/1 kVac and 3.6/6 kVac available on request

Last Update (04.03.2017)


©2017 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
PRODUCT INFORMATION

NSGAFÖU 1.8/3 kV

Norm references / approvals


<VDE> NSGAFÖU 1.8/3 kV design certification according to VDE 0250-602

Design
Fine-wire strand made of tin-plated copper wires
Core insulation: Rubber compound, type 3GI3
Outer coating: Rubber compound, type 5GM3
No outer sheath

Technical Data
Classification: ETIM 5.0 Class-ID: EC000993
ETIM 5.0 Class-Description: Single-core cable
Conductor design: Fine wire according to VDE 0295 class 5 / IEC 60228 class 5
Minimum bending radius: Flexible use: 10 x outer diameter
Fixed installation: 6 x outer diameter
Nominal voltage: U0/U: 1.8/3 kV
Test voltage: 6000 V
Current load capacity: According to VDE 0298 part 4, table 15
Temperature range: Flexible use: -25°C to +90°C
Fixed installation: -40°C to +90°C

Note
Unless otherwise specified, the product values shown are nominal values. You can receive further values, such as tolerances,
upon request if they available and have been released for publication.
Copper price basis: EUR 150/100 kg; see catalogue appendix T17 for the application and definition of "Metal price basis" and
"Metal index"
Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
Packaging: Ring ≤ 30 kg or ≤ 250 m, otherwise drum
Please specify the preferred packaging (e.g. 1 x 500 m drum or 5 x 100 m rings)
Photographs are not to scale and do not represent detailed images of the respective products.
* Prices are net prices without VAT and surcharges. Sale to business customers only.

Last Update (04.03.2017)


©2017 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
Powered by TCPDF (www.tcpdf.org)

NSGAFÖU 1.8/3 kV
Article number Conductor cross-section (mm²) Outer diameter (mm) Copper index (kg/km) Weight (kg/km)
PN 0456 / 02_03.16
You can find the current technical data in the corresponding data sheet.
Product Management www.lappkabel.de
©2017 Lapp Group - Technical changes reserved
Last Update (04.03.2017)

1600300 1.5 7 14.4 60


1600301 2.5 7.5 24 70
1600302 4 9 38.4 90
1600303 6 9.5 57.6 120
1600304 10 11 96 180
1600305 16 13 153.6 250
1600306 25 15 240 390
1600307 35 16.5 336 470
1600308 50 18 480 625
1600309 70 20.5 672 880
1600310 95 24 912 1190
1600311 120 26 1152 1430
1600312 150 28 1440 1750
1600313 185 31 1776 2160
1600314 240 34.5 2304 2640
3026826 300 38 2880 3545