General Notes: Fourth Floor Plan
General Notes: Fourth Floor Plan
General Notes: Fourth Floor Plan
55000
300 X 300mm
300 X 300mm
AUTOMATIC SHUTTER
AUTOMATIC SHUTTER 3800 1200 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 1825 3425 LOUVERS / VENT CAP
LOUVERS / VENT CAP
1575 3175
1550
C
STO. EF1
EF1 EF1 EF1
HE
3150
3150
CF CF CF CF CF CF CF CF CF CF
SHE
CLASS ROOM CLASS ROOM CLASS ROOM CLASS ROOM CLASS ROOM
7000
1000
1 2 3 4 5
9500
9500
BLACKBOARD BASE
BLACKBOARD BASE
BLACKBOARD BASE
BLACKBOARD BASE
BLACKBOARD BASE
3850
3850
CF CF CF CF CF CF CF CF CF CF
DN UP
B
DN DN
2500
2500
C O R R I D O R C O R R I D O R C O R R I D O R
200 X 200
FAN
100 VERIFY
3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BLADE
COORDINATE CLOSELY HIS WORK WITH THE OTHER TRADES
CONCERNED. DESIGNATION A B C D E F G H I J K L M
150
POWER
E
EF1 354 126 140 200 135 230 268 13 300 108 13 108 13 CORD
4. REFRIGERANT SUCTION LINES SHALL BE INSULATED WITH 25 mm THICK
PREMOULDED ELASTOMERIC RUBBER INSULATION AS MANUFACTURED 600
H
3mm THICK
BY "ARMAFLEX",AEROFLEX OR APPROVED EQUAL. STAINLESS STEEL
EXHAUST FAN (WALL MOUNTED) DETAIL
VERIFY
4
5. INDIVIDUAL WEATHER PROOF TYPE CIRCUIT BREAKER SHALL BE FRONT VIEW CORD OUTLET INSTALLATION
SCALE NTS
PROVIDED PROVIDED FOR ALL CONDENSING UNITS. EXHAUST K HOLE
KITCHEN
M-4
F sq. J GRILL CONNECTION TO
6. ALL EXPOSED DRAIN LINES TO THE CEILING SHALL BE PROVIDED WITH EXHAUST PIPE GROUND FLOOR LINE
INSULATION TYPICAL TO REFRIGERANT PIPING. (REFER TO PIPE
INSULATION DETAIL.) 3 EXHAUST HOOD DETAIL ENCLOSED CIRCUIT BREAKER
M
G sq.
L
D
7. ALL EXPOSED DRAIN LINES TO THE CEILING SHALL BE PROVIDED WITH EF-1 M-4 NOT TO SCALE (SIZE AS REQUIRED)
FAN CASING
E
300
H
ØD
2400
ØA
W
EXHAUST FANS A
250 TO 1100 800
PROVIDE VIBRATOR ISOLATOR
CONDUIT PIPE TO
0.30 M
AIR COOLED CONDENSING UNITS C ACCU PEDESTAL WITH CIRCUIT HOMERUN C
1500 TO 4000 50 x 50 x6mm ANGLE BAR (SIZE AS REQUIRED) DRAIN B E
L
HOLE
16mm Ø
CEILING FANS PLAN FINISHED FLOOR LINE
FLR. SLAB
EXPANSION BOLT
DESIGNED: SIGNED
REPUBLIC OF THE PHILIPPINES PROJECT AND LOCATION: SHEET CONTENTS: SUBMITTED: RECOMMENDING APPROVAL: APPROVED: CONCURRED: SET NO. SHEET NO.
BENJAMIN R. GALMAK
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS GENERAL NOTES
ENGINEER II
SEE COVER SHEET FOR SIGNATURE SEE COVER SHEET FOR SIGNATURE SEE COVER SHEET FOR SIGNATURE
MODIFIED STANDARD DPWH - DEPED LEGENDS
CADD: SIGNED SIGNED
BUREAU OF DESIGN FOURTH FLOOR VENTILATION AND CEILING FAN
EB FUMAR
ENGINEERING ASSISTANT
BR GALMAK
ENGINEER II
APPROVED WITH SIGNATURE BOD
M-4
BUILDINGS DIVISION FOUR (4) STOREY, TWENTY (20) LAYOUT JOSEPHINE P. ISTURIS LEA N. DELFINADO GILBERTO S. REYES LEONOR M. BRIONES
CLASSROOM SCHOOL BUILDING MISCELLANEOUS DETAILS
CHECKED: SIGNED B 8 90
CORNELIO T. EVANGELISTA JR.4 OIC, UNDERSECRETARY FOR
BONIFACIO DRIVE PORT AREA, MANILA CHIEF, BUILDINGS DIVISION OFFICER-IN-CHARGE SECRETARY, DEP ED
ENGINEER III TECHNICAL SERVICES, DPWH