Channel Thickness Calculation: 1 Design Data: CO2 Condenser / Liquefier Design Code of Construction
Channel Thickness Calculation: 1 Design Data: CO2 Condenser / Liquefier Design Code of Construction
Channel Thickness Calculation: 1 Design Data: CO2 Condenser / Liquefier Design Code of Construction
Bolt material
Bolt Diameter = M 27
Bolt root area = 459.00 mm2
No. of bolt (n) = 12
Bolt circle diameter (dt) = 370 mm
Diameter of bolt hole (dL) = 30 mm
Yeild strength(Operating) (Ky) = 655.00 MPa
Tensile Strength(operating) (Kt) = 791.00 Mpa
RATIO = 0.83 >0.8
Page 1 of 6
Design Dossier for Unitank-1728HL
Openings Details
CA1 = SQRT(A/(A-Aa))
A = 141862.54 mm2
CA1 = 1.000
Page 2 of 6
Design Dossier for Unitank-1728HL
SD = 1.2 B5 6.3.1
𝛿 = 1.535595432
C1 = 0.580893385
C1' = 0.580893385
Thickness of Channel 𝑠 =
𝑐_1^′∗𝑑_𝐷∗√((𝑝∗𝑆)/(10∗𝐾) )+ 𝐶_1+𝐶_2
The minimum required bolt load on flange in service condition : (B7, 7.1.2.1)
Page 3 of 6
Design Dossier for Unitank-1728HL
dte = dt(1-2/n^2)
= 364.8611111
FRMB = 0
The minimum required bolt load on flange in Test condition : (B7, 7.1.2.1)
Page 4 of 6
Design Dossier for Unitank-1728HL
dte = dt(1-2/n^2)
= 364.8611111
FRMB = 0
The minimum required bolt load for bolting up condition : (B7, 7.1.2.2)
FMR0 = 0
FDV = 329311.1667 N
FDv* = 273183.233 N
Page 5 of 6
Design Dossier for Unitank-1728HL
𝑍.√(𝐹_𝑠𝑏/
(𝐾.𝑛)) = 7.6916 < 20
c5 = 3.00 mm Clause 8 B7
𝑑_(𝑠 ) = 10.692 mm
𝑑_(𝑠 )= 8.34 mm
Z = 1.27 Table 3, B7
𝑑_(𝑠 )= 7.49 mm
ds = 10.69 mm
Page 6 of 6