Control Systems Notes DEE M2 June
Control Systems Notes DEE M2 June
Design: The process of conceiving or inventing the forms, parts, and details of system to
achieve a specified purpose.
Simulation: A model of a system that is used to investigate the behavior of a system by
utilizing actual input signals.
Optimization: The adjustment of the parameters to achieve the most favorable or
advantageous design.
Feedback Signal: A measure of the output of the system used for feedback to control the
system.
Negative feedback: The output signal is feedback so that it subtracts from the input signal.
Block diagrams: Unidirectional, operational blocks that represent the transfer functions of
the elements of the system.
Signal Flow Graph (SFG): A diagram that consists of nodes connected by several directed
branches and that is a graphical representation of a set of linear relations.
Specifications: Statements that explicitly state what the device or product is to be and to do.
It is also defined as a set of prescribed performance criteria.
Open-loop control system: A system that utilizes a device to control the process without
using feedback. Thus the output has no effect upon the signal to the process.
Closed-loop feedback control system: A system that uses a measurement of the output and
compares it with the desired output.
Regulator: The control system where the desired values of the controlled outputs are more or
less fixed and the main problem is to reject disturbance effects.
Servo system: The control system where the outputs are mechanical quantities like
acceleration, velocity or position.
Stability: It is a notion that describes whether the system will be able to follow the input
command. In a non-rigorous sense, a system is said to be unstable if its output is out of
control or increases without bound.
Multivariable Control System: A system with more than one input variable or more than
one output variable.
Trade-off: The result of making a judgment about how much compromise must be made
between conflicting criteria.
Classification of control system
➢ Natural control system, Man-made control system and hybrid control system:
Natural control system: It is a control system that is created by nature, i.e. solar
system, digestive system of any animal, etc.
Man-made control system: It is a control system that is created by humans, i.e.
automobile, power plants etc.
➢ Automatic control system and Combinational control system:
Automatic control system: It is a control system that is made by using basic theories
from mathematics and engineering. This system mainly has sensors, actuators and
responders.
Combinational control system: It is a control system that is a combination of natural
and man-made control systems, i.e. driving a car etc.
➢ Time-variant control system and Time-invariant control system:
Time-variant control system: It is a control system where any one or more
parameters of the control system vary with time i.e. driving a vehicle.
Time-invariant control system: It is a control system where none of its parameters
vary with time i.e. control system made up of inductors, capacitors and resistors only.
➢ Linear control system and Non-linear control system:
Linear control system: It is a control system that satisfies properties of homogeneity
and additive.
Non-linear control system: It is a control system that does not satisfy properties of
homogeneity and additive.
➢ Continuous-Time control system and Discrete-Time control system:
Continuous-Time control system: It is a control system where performances of all
of its parameters are function of time, i.e. armature type speed control of motor.
Discrete -Time control system: It is a control system where performances of all of
its parameters are function of discrete time i.e. microprocessor type speed control of
motor.
➢ Deterministic control system and Stochastic control system:
Deterministic control system: It is a control system where its output is predictable
or repetitive for certain input signal or disturbance signal.
Stochastic control system:It is a control system where its output is unpredictable or
non-repetitive for certain input signal or disturbance signal.
➢ Lumped-parameter control system and Distributed-parameter control system:
Lumped-parameter control system: It is a control system where its mathematical
model is represented by ordinary differential equations.
Distributed-parameter control system:It is a control system where its mathematical
model is represented by an electrical network that is a combination of resistors,
inductors and capacitors.
➢ Single-input-single-output (SISO) control system and Multi-input-multi-output
(MIMO) control system:
SISO control system: It is a control system that has only one input and one output.
MIMO control system:It is a control system that has only more than one input and
more than one output.
➢ Open-loop control system and Closed-loop control system:
Open-loop control system: It is a control system where its control action only
depends on input signal and does not depend on its output response.
Closed-loop control system:It is a control system where its control action depends
on both of its input signal and output response.
Open-loop control system and Closed-loop control system
(a) Open-loop control system:
It is a control system where its control action only depends on input signal and does
not depend on its output response as shown below;
Examples: automatic electric iron, missile launcher, speed control of DC motor, etc.
Advantages:
More accurate operation than that of open-loop control system
Can operate efficiently when input or system parameters are variable in
nature
Less nonlinearity effect of these systems on output response
High bandwidth of operation
There is facility of automation
Time to time recalibration of the parameters are not required
Dis-advantages:
Complex design and difficult to construct
Expensive than that of open-loop control system
Complicate for maintenance
Less stable operation than that of open-loop control system
1.4. Servomechanism
It is the feedback unit used in a control system. In this system, the control variable is
a mechanical signal such as position, velocity or acceleration. Here, the output signal
is directly fed to the comparator as the feedback signal, b(t) of the closed-loop control
system. This type of system is used where both the command and output signals are
mechanical in nature. A position control system as shown in Fig.1.3 is a simple
example of this type mechanism. The block diagram of the servomechanism of an
automatic steering system is shown in Fig.1.4
Missile launcher
Machine tool position control
Power steering for an automobile
Roll stabilization in ships, etc.
1.5. Regulators
It is also a feedback unit used in a control system like servomechanism. But, the
output is kept constant at its desired value. The schematic diagram of a regulating
system is shown in Fig.1.5. Its corresponding simplified block diagram model is
shown in Fig.1.6.
Temperature regulator
Speed governor
Frequency regulators, etc.
Transfer Function
1. Definition: It is the ratio of Laplace transform of output signal to Laplace transform of input
signal assuming all the initial conditions to be zero, i.e.
Let, there is a given system with input r(t) and output c(t) as shown in Fig.3.1 (a), then its
Laplace domain is shown in Fig.3.1 (b). Here, input and output are R(s) and C(s) respectively.
G(s) is the transfer function of the system. It can be mathematically represented as follows.
General Form of Transfer Function
3.3. Properties of Transfer function:
Zero initial condition
It is same as Laplace transform of its impulse response
𝑑
Replacing ‘s’ by in the transfer function, the differential equation can be obtained
𝑑𝑡
Poles and zeros can be obtained from the transfer function
Stability can be known
Can be applicable to linear system only
3.4. Advantages of Transfer function:
It is a mathematical model and gain of the system
𝑑
Replacing ‘s’ by 𝑑𝑡 in the transfer function, the differential equation can be obtained
Poles and zeros can be obtained from the transfer function
Stability can be known
Impulse response can be found
3.5. Disadvantages of Transfer function:
Applicable only to linear system
Not applicable if initial condition cannot be neglected
It gives no information about the actual structure of a physical system
Summing point: It is the component of a block diagram model at which two or more signals
can be added or subtracted. In Fig.15, inputs R(s) and B(s) have been given to a summing
point and its output signal is E(s). Here,
Take-off point: It is the component of a block diagram model at which a signal can be taken
directly and supplied to one or more points as shown in Fig.5.2.
Forward path: It is the direction of signal flow from input towards output.
Feedback path: It is the direction of signal flow from output towards input.
Example: Eq (5.3), (5.4) and (5.5) are combiningly results in the following block diagram
Model
Signal Flow Graphs (SFGs)
It is a pictorial representation of a system that graphically displays the signal transmission in
it.
Basic Definitions in SFGs:
Input or source node: It is a node that has only outgoing branches i.e. node ‘r’ in Fig.6.1.
Output or sink node: It is a node that has only incoming branches i.e. node ‘c’ in Fig.6.1.
Chain node: It is a node that has both incoming and outgoing branches i.e. nodes ‘x1’,
‘x2’,‘x3’,‘x4’,‘x5’and ‘x6’ in Fig.6.1.
Gain or transmittance: It is the relationship between variables denoted by two nodes or
value of a branch. In Fig.6.1, transmittances are ‘t1’, ‘t2’,‘t3’,‘t4’,‘t5’and ‘t6’.
Forward path: It is a path from input node to output node without repeating any of the nodes
in between them. In Fig.6.1, there are two forward paths, i.e. path-1:‘r-x1-x2-x3-x4-x5-x6-c’
and
path-2:‘r-x1-x3-x4-x5-x6-c’.
Feedback path: It is a path from output node or a node near output node to a node near input
node without repeating any of the nodes in between them (Fig.6.1).
Loop: It is a closed path that starts from one node and reaches the same node after trading
through other nodes. In Fig.6.1, there are four loops, i.e. loop-1:‘x2-x3-x4-x1’, loop-2:‘x5-
x6-x5’, loop-3:‘x1-x2-x3-x4-x5-x6-x1’ and loop-4:‘x1-x3-x4-x5-x6-x1’.
Self Loop: It is a loop that starts from one node and reaches the same node without trading
through other nodes i.e. loop in node ‘x4’ with transmittance ‘t55’ in Fig.6.1.
Path gain: It is the product of gains or transmittances of all branches of a forward path. In
Fig.6.1, the path gains are P1 = t1t2t3t4t5 (for path-1) and P2 = t9t3t4t5 (for path-2).
Loop gain: It is the product of gains or transmittances of all branches of a loop In Fig.6.1,
there are four loops, i.e. L1 = -t2t3t6, L2 = -t5t7, L3 = -t1t2t3t4t5t8, and L4 = -t9t3t4t5t8.
Dummy node: If the first node is not an input node and/or the last node is not an output node
than a node is connected before the existing first node and a node is connected after the
existing last node with unity transmittances. These nodes are called dummy nodes. In Fig.6.1,
‘r’ and ‘c’ are the dummy nodes.
Non-touching Loops: Two or more loops are non-touching loops if they don’t have any
common nodes between them. In Fig.6.1, L1 and L2 are non-touching loops
Example:
Properties SFGs:
Applied to linear system
Arrow indicates signal flow
Nodes represent variables, summing points and take-off points
Algebraic sum of all incoming signals and outgoing nodes is zero
SFG of a system is not unique
Overall gain of an SFG can be determined by using Mason’s gain formula
Let’s find the SFG of following block diagram model shown in Fig.6.2.
Solution
System modelling
System modelling is the process of developing abstract models of a system, with each model
presenting a different view or perspective of that system. It is about representing a system using
some kind of graphical notation, which is now almost always based on notations in the Unified
Modeling Language (UML). Models help the analyst to understand the functionality of the system.
1. Mechanical systems
2. Electrical systems
3. Electronic systems
4. Thermal systems
5. Hydraulic systems
6. Chemical systems
Mathematical modeling of a control system is the process of drawing the block diagrams
for these types of systems in order to determine their performance and transfer functions.
Mechanical systems
Components of a mechanical system: Mechanical systems are of two types, i.e.
i. Translational mechanical system
ii. Rotational mechanical system.
Solution
2. Rotational mechanical system
There are three basic elements in a Rotational mechanical system, i.e.
(a) Inertia
(b) Spring
(c) Damper.
Inertia:
If a torqueT is applied on a body with inertia J and it displaces distance Ө1 in the direction of T and
distance Ө2 in the opposite direction,
(b) Spring:
A spring is denoted by K. If a torqueT is applied on it and it displays distance Ө, then T = K . If a torque
T is applied on a body with inertia J and it displays distance Ө1 in the direction of T and distance Ө2 in the
opposite direction, then T = K( 1 -2 ).
(c)Damper:
A damper is denoted by D. If a torque T is applied on it and it displays distance Ө, then
𝑑
T= D d
𝑑𝑡
If a torque T is applied on a body with inertia J and it displays distance Ө1 in the direction of T and
distance Ө2 in the opposite direction, then,
Electrical systems
Mathematical Modelling of Electrical System
And also we have three parameters which are active and passive components:
Same amount of current flows across the three parameters,therefore voltage across each is ;
The above equation can be re-written inform of charge (q) ,Therefore total voltage can also
be written as below;
𝑑𝑖 1
𝑒(𝑡) = iR + L + ∫ 𝑖𝑑𝑡 …………………..(i)
𝑑𝑡 𝑐
𝑑𝑞
But i=
𝑑𝑡
q=∫ 𝑖𝑑𝑡
𝑑𝑖 𝒅𝟐 𝒒
= 𝟐
𝑑𝑡 𝒅𝒕
Substituting the above values in eqn (i) above you get;
𝑑𝑞 𝒅𝟐 𝒒 1
𝑒(𝑡) = 𝑅 +𝑙 + 𝑞 ……………………(ii)
𝑑𝑡 𝒅𝒕𝟐 𝑐
1
𝐸(𝑠) = 𝑄(𝑆) (𝑅𝑆 + 𝐿𝑆 2 + )
𝐶
Obtaining the transfer function ;
𝑄(𝑆) 1
T.F = = 1
𝐸(𝑠) 𝑅𝑆+𝐿𝑆 2 +𝐶
Parallel electrical network
From the network above,the voltage across each component is same .Therefore current across
each component is given by;
If iL is the current through an inductor and v is the voltage developed in it, then
1
iL= 𝐿 ∫ 𝑣𝑑𝑡
Current across a capacitor
If ic is the current through a capacitor and v is the voltage developed in it, then
𝑑𝑣
ic = c
𝑑𝑡
it = iR + iL + iC
substituting for iR , iL , iC respectively you get
it = 𝑅
𝑉
+
1
𝐿
𝑑𝑣
∫ 𝑣𝑑𝑡 + c 𝑑𝑡 ……………………….(i)
𝑑𝑣 𝑑2
= …………………..(iii)
𝑑𝑡 𝑑𝑡 2
𝑆(𝑠) (𝑠)
𝐼(𝑆) = + + 𝐶𝑆 2 (𝑆)
𝑅 𝐿
Fig.4.12. (a) a voltage-source electrical system,(b) a translational mechanical system and (c) a rotational control
System
The solutions for all the above three equations are same. Therefore, the above shown three figures are
analogous to each other. There are two important types of analogous systems, i.e. force-voltage (f-v)
analogy and force-current analogy.
Force – voltage analogy can be drawn as follows.